Refine
Document Type
- Article (15) (remove)
Language
- English (15) (remove)
Has Fulltext
- yes (15)
Is part of the Bibliography
- no (15)
Institute
- Physik (15)
The neutron sensitivity of the C6D6 detector setup used at n_TOF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a natC sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured natC yield has been discovered, which prevents the use of natC data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron background for two different samples are demonstrating the important role of accurate simulations of the neutron background in capture cross-section measurements.
The neutron capture cross section of 58Ni was measured at the neutron time of flight facility n_TOF at CERN, from 27 meV to 400 keV neutron energy. Special care has been taken to identify all the possible sources of background, with the so-called neutron background obtained for the first time using high-precision GEANT4 simulations. The energy range up to 122 keV was treated as the resolved resonance region, where 51 resonances were identified and analyzed by a multilevel R-matrix code SAMMY. Above 122 keV the code SESH was used in analyzing the unresolved resonance region of the capture yield. Maxwellian averaged cross sections were calculated in the temperature range of kT = 5 – 100 keV, and their astrophysical implications were investigated.
The accuracy on neutron capture cross section of fissile isotopes must be improved for the design of future nuclear systems such as Gen-IV reactors and Accelerator Driven Systems. The High Priority Request List of the Nuclear Energy Agency, which lists the most important nuclear data requirements, includes also the neutron capture cross sections of fissile isotopes such as 233,235U and 239,241Pu. A specific experimental setup has been used at the CERN n_TOF facility for the measurement of the neutron capture cross section of 235U by a set of micromegas fission detectors placed inside a segmented BaF2 Total Absorption Calorimeter.
Neutron total cross sections are an important source of experimental data in the evaluation of neutron-induced cross sections. The sum of all neutron-induced reaction cross sections can be determined with a precision of a few per cent in a relative measurement. The neutron spectrum of the photoneutron source nELBE extends in the fast region from about 100 keV to 10 MeV and has favourable conditions for transmission measurements due to the low instantaneous flux of neutrons and low gamma-flash background. Several materials of interest (in part included in the CIELO evaluation or on the HPRL of OECD/NEA) have been investigated: 197Au [1, 2], natFe [2], natW [2], 238U, natPt, 4He, natO, natNe, natXe. For gaseous targets high pressure gas cells with flat end-caps have been built that hold up to 200 bar pressure. The experimental setup will be presented including results from several transmission experiments and the data analysis leading to the total cross sections will be discussed.
We measured the neutron capture cross sections of 69Ga and 71Ga for a quasi-stellar spectrum at kBT = 25 keV and a spectrum with a peak energy at 90 keV by the activation technique at the Joint Research Centre (JRC) in Geel, Belgium. Protons were provided by an electrostatic Van de Graaff accelerator to produce neutrons via the reaction 7Li(p,n). The produced activity was measured via the γ emission of the product nuclei by high-purity germanium detectors. We present preliminary results.