Refine
Document Type
- Article (3)
Language
- English (3)
Has Fulltext
- yes (3)
Is part of the Bibliography
- no (3)
Keywords
- atrial fibrillation (2)
- catheter ablation (2)
- Atrial fibrillation (1)
- Catheter ablation (1)
- Cryoballoon (1)
- Follow-up (1)
- Radiofrequency (1)
- Rehospitalization (1)
- cryoballoon (1)
- health economics (1)
- pulmonary vein isolation (1)
- radiofrequency (1)
Institute
- Medizin (3)
Aims: The primary safety and efficacy endpoints of the randomized FIRE AND ICE trial have recently demonstrated non-inferiority of cryoballoon vs. radiofrequency current (RFC) catheter ablation in patients with drug-refractory symptomatic paroxysmal atrial fibrillation (AF). The aim of the current study was to assess outcome parameters that are important for the daily clinical management of patients using key secondary analyses. Specifically, reinterventions, rehospitalizations, and quality-of-life were examined in this randomized trial of cryoballoon vs. RFC catheter ablation.
Methods and results: Patients (374 subjects in the cryoballoon group and 376 subjects in the RFC group) were evaluated in the modified intention-to-treat cohort. After the index ablation, log-rank testing over 1000 days of follow-up demonstrated that there were statistically significant differences in favour of cryoballoon ablation with respect to repeat ablations (11.8% cryoballoon vs. 17.6% RFC; P = 0.03), direct-current cardioversions (3.2% cryoballoon vs. 6.4% RFC; P = 0.04), all-cause rehospitalizations (32.6% cryoballoon vs. 41.5% RFC; P = 0.01), and cardiovascular rehospitalizations (23.8% cryoballoon vs. 35.9% RFC; P < 0.01). There were no statistical differences between groups in the quality-of-life surveys (both mental and physical) as measured by the Short Form-12 health survey and the EuroQol five-dimension questionnaire. There was an improvement in both mental and physical quality-of-life in all patients that began at 6 months after the index ablation and was maintained throughout the 30 months of follow-up.
Conclusion: Patients treated with cryoballoon as opposed to RFC ablation had significantly fewer repeat ablations, direct-current cardioversions, all-cause rehospitalizations, and cardiovascular rehospitalizations during follow-up. Both patient groups improved in quality-of-life scores after AF ablation.
Clinical trial registration: ClinicalTrials.gov identifier: NCT01490814.
Background: This study sought to assess payer costs following cryoballoon or radiofrequency current (RFC) catheter ablation of paroxysmal atrial fibrillation in the randomized FIRE AND ICE trial.
Methods and Results: A trial period analysis of healthcare costs evaluated the impact of ablation modality (cryoballoon versus RFC) on differences in resource use and associated payer costs. Analyses were based on repeat interventions, rehospitalizations, and cardioversions during the trial, with unit costs based on 3 national healthcare systems (Germany [€], the United Kingdom [£], and the United States [Embedded Image]). Total payer costs were calculated by applying standard unit costs to hospital stays, using International Classification of Diseases, 10th Revision diagnoses and procedure codes that were mapped to country‐specific diagnosis‐related groups. Patients (N=750) randomized 1:1 to cryoballoon (n=374) or RFC (n=376) ablation were followed for a mean of 1.5 years. Resource use was lower in the cryoballoon than the RFC group (205 hospitalizations and/or interventions in 122 patients versus 268 events in 154 patients). The cost differences per patient in mean total payer costs during follow‐up were €640, £364, and Embedded Image925 in favor of cryoballoon ablation (P=0.012, 0.013, and 0.016, respectively). This resulted in trial period total cost savings of €245 000, £140 000, and Embedded Image355 000.
Conclusions: When compared with RFC ablation, cryoballoon ablation was associated with a reduction in resource use and payer costs. In all 3 national healthcare systems analyzed, this reduction resulted in substantial trial period cost savings, primarily attributable to fewer repeat ablations and a reduction in cardiovascular rehospitalizations with cryoballoon ablation.
Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Identifier: NCT01490814.
The FIRE AND ICE Trial (ClinicalTrials.gov, identifier NCT01490814) was initiated in 2012 as a multicenter, randomized, head‐to‐head comparison of radiofrequency current (RFC) and cryoballoon catheter ablation for the treatment of patients with drug‐refractory symptomatic paroxysmal atrial fibrillation (AF). Six years on, it remains the largest, randomized comparison of safety and efficacy between 2 catheter ablation modalities used in the treatment of patients with AF. This landmark trial not only established noninferiority between cryoballoon and RFC ablation for pulmonary vein isolation (PVI) with regard to the study's efficacy and safety primary end points,1 but also, it evaluated secondary end points that were critical for a representative study interpretation. ...