Refine
Year of publication
Language
- English (266)
Has Fulltext
- yes (266)
Is part of the Bibliography
- no (266)
Keywords
- BESIII (14)
- Branching fraction (9)
- e +-e − Experiments (9)
- Hadronic decays (5)
- Particle and Resonance Production (5)
- Branching fractions (4)
- Lepton colliders (4)
- Quarkonium (4)
- Charm Physics (3)
- Charmed mesons (3)
Institute
Observation of ηc(2S) → 3(π⁺π⁻) and measurements of χcJ → 3(π⁺π⁻) in ψ(3686) radiative transitions
(2022)
The hadronic decay 𝜂𝑐(2𝑆)→3(𝜋+𝜋−) is observed with a statistical significance of 9.3 standard deviations using (448.1±2.9)×106 𝜓(3686) events collected by the BESIII detector at the BEPCII collider. The measured mass and width of 𝜂𝑐(2𝑆) are (3643.4±2.3 (stat)±4.4 (syst)) MeV/𝑐2 and (19.8±3.9 (stat)±3.1 (syst)) MeV, respectively, which are consistent with the world average values within two standard deviations. The product branching fraction ℬ[𝜓(3686)→𝛾𝜂𝑐(2𝑆)]×ℬ[𝜂𝑐(2𝑆)→3(𝜋+𝜋−)] is measured to be (9.2±1.0 (stat)±1.2 (syst))×10−6. Using ℬ[𝜓(3686)→𝛾𝜂𝑐(2𝑆)]=(7.0+3.4−2.5)×10−4, we obtain ℬ[𝜂𝑐(2𝑆)→3(𝜋+𝜋−)]=(1.31±0.15 (stat)±0.17 (syst) (+0.64−0.47) (extr))×10−2, where the third uncertainty is from ℬ[𝜓(3686)→𝛾𝜂𝑐(2𝑆)]. We also measure the 𝜒𝑐𝐽→3(𝜋+𝜋−) (𝐽=0, 1, 2) decays via 𝜓′→𝛾𝜒𝑐𝐽 transitions. The branching fractions are ℬ[𝜒𝑐0→3(𝜋+𝜋−)]=(2.080±0.006 (stat)±0.068 (syst))×10−2, ℬ[𝜒𝑐1→3(𝜋+𝜋−)]=(1.092±0.004 (stat)±0.035 (syst))×10−2, and ℬ[𝜒𝑐2→3(𝜋+𝜋−)]=(1.565±0.005 (stat)±0.048 (syst))×10−2.
Observation of ηc(2S) → 3(π⁺π⁻) and measurements of χcJ → 3(π⁺π⁻) in ψ(3686) radiative transitions
(2022)
The hadronic decay ηc(2S)→3(π+π−) is observed with a statistical significance of 9.3 standard deviations using (448.1±2.9)×106 ψ(3686) events collected by the BESIII detector at the BEPCII collider. The measured mass and width of ηc(2S) are (3643.4±2.3(stat.)±4.4(syst.)) MeV/c2 and (19.8±3.9(stat.)±3.1(syst.)) MeV, respectively, which are consistent with the world average values within two standard deviations. The product branching fraction B[ψ(3686) → γηc(2S)]×B[ηc(2S)→3(π+π−)] is measured to be (9.2±1.0(stat.)±0.9(syst.))×10−6. Using B[ψ(3686)→γηc(2S)]=(7.0+3.4−2.5)×10−4, we obtain B[ηc(2S)→3(π+π−)]=(1.31±0.15(stat.)±0.13(syst.)(+0.64−0.47)(extr))×10−2, where the third uncertainty is from B[ψ(3686)→γηc(2S)]. We also measure the χcJ→3(π+π−) (J=0,1,2) decays via ψ(3686)→γχcJ transitions. The branching fractions are B[χc0→3(π+π−)]=(2.080±0.006(stat.)±0.068(syst.))×10−2, B[χc1→3(π+π−)]=(1.092±0.004(stat.)±0.035(syst.))×10−2, and B[χc2→3(π+π−)]=(1.565±0.005(stat.)±0.048(syst.))×10−2.
Observation of ηc(2S) → 3(π⁺π⁻) and measurements of χcJ → 3(π⁺π⁻) in ψ(3686) radiative transitions
(2022)
The hadronic decay ηc(2S)→3(π+π−) is observed with a statistical significance of 9.3 standard deviations using (448.1±2.9)×106 ψ(3686) events collected by the BESIII detector at the BEPCII collider. The measured mass and width of ηc(2S) are (3643.4±2.3(stat.)±4.4(syst.)) MeV/c2 and (19.8±3.9(stat.)±3.1(syst.)) MeV, respectively, which are consistent with the world average values within two standard deviations. The product branching fraction B[ψ(3686)→γηc(2S)]×B[ηc(2S)→3(π+π−)] is measured to be (9.2±1.0(stat.)±0.9(syst.))×10−6. Using B[ψ(3686)→γηc(2S)]=(7.0+3.4−2.5)×10−4, we obtain B[ηc(2S)→3(π+π−)]=(1.31±0.15(stat.)±0.13(syst.)(+0.64−0.47)(extr))×10−2, where the third uncertainty is from B[ψ(3686)→γηc(2S)]. We also measure the χcJ→3(π+π−) (J=0,1,2) decays via ψ(3686)→γχcJ transitions. The branching fractions are B[χc0→3(π+π−)]=(2.080±0.006(stat.)±0.068(syst.))×10−2, B[χc1→3(π+π−)]=(1.092±0.004(stat.)±0.035(syst.))×10−2, and B[χc2→3(π+π−)]=(1.565±0.005(stat.)±0.048(syst.))×10−2.
We report a measurement of the cross section for the process e+e−→π+π−J/ψ around the X(3872) mass in search for the direct formation of e+e−→X(3872) through the two-photon fusion process. No enhancement of the cross section is observed at the X(3872) peak and an upper limit on the product of electronic width and branching fraction of X(3872)→π+π−J/ψ is determined to be Γee×B(X(3872)→π+π−J/ψ)<7.5×10−3eV at 90% confidence level under an assumption of total width of 1.19±0.21 MeV. This is an improvement of a factor of about 17 compared to the previous limit. Furthermore, using the latest result of B(X(3872)→π+π−J/ψ), an upper limit on the electronic width Γee of X(3872) is obtained to be <0.32eV at the 90% confidence level.
A measurement of the 𝐶𝑃-even fraction of the decay 𝐷0→𝜋+𝜋−𝜋+𝜋− is performed with a quantum-correlated 𝜓(3770)→𝐷¯𝐷 data sample collected by the BESIII experiment, corresponding to an integrated luminosity of 2.93 fb−1. Using a combination of 𝐶𝑃 eigenstates, 𝐷→𝜋+𝜋−𝜋0 and 𝐷→𝐾0𝑆,𝐿𝜋+𝜋− as tagging modes, the 𝐶𝑃-even fraction is measured to be 𝐹4𝜋+=0.735±0.015±0.005, where the first uncertainty is statistical and the second is systematic. This is the most precise determination of this quantity to date. It provides valuable model-independent input for the measurement of the angle 𝛾 of the Cabibbo-Kobayashi-Maskawa matrix with 𝐵±→𝐷𝐾± decays, and for time-dependent studies of 𝐶𝑃 violation and mixing in the 𝐷0−¯𝐷0 system.
A measurement of the CP-even fraction of the decay D0→π+π−π+π− is performed with a quantum-correlated ψ(3770)→DD¯ data sample collected by the BESIII experiment, corresponding to an integrated luminosity of 2.93 fb−1. Using a combination of CP eigenstates, D→π+π−π0 and D→K0S,Lπ+π− as tagging modes, the CP-even fraction is measured to be F4π+=0.735±0.015±0.005, where the first uncertainty is statistical and the second is systematic. This is the most precise determination of this quantity to date. It provides valuable model-independent input for the measurement of the CKM angle γ with B±→DK± decays, and for time-dependent studies of CP violation and mixing in the D0-D¯0 system.
The Born cross sections of the e+e− → D*+D*− and e+e− → D*+D− processes are measured using e+e− collision data collected with the BESIII experiment at center-of-mass energies from 4.085 to 4.600 GeV, corresponding to an integrated luminosity of 15.7 fb−1. The results are consistent with and more precise than the previous measurements by the Belle, Babar and CLEO collaborations. The measurements are essential for understanding the nature of vector charmonium and charmonium-like states.
We report the first measurements of the absolute branching fractions of D0 → K0 Lϕ, D0 → K0Lη, D0 → K0Lω, and D0 → K0Lη0, by analyzing 2.93 fb−1 of eþe− collision data taken at a center-of-mass energy of 3.773 GeV with the BESIII detector. Taking the world averages of the branching fractions of D0 → K0Sϕ, D0 → K0Sη, D0 → K0Sω, and D0 → K0Sη0, the K0S − K0L asymmetries RðD0; XÞ in these decay modes are obtained. The CP asymmetries in these decays are also determined. No significant CP violation is observed
Observation of resonance structures in e⁺e⁻ → π⁺π⁻ψ₂(3823) and mass measurement of ψ₂(3823)
(2022)
Using a data sample corresponding to an integrated luminosity of 11.3 fb−1 collected at center-of-mass energies from 4.23 to 4.70 GeV with the BESIII detector, we measure the product of the 𝑒+𝑒−→𝜋+𝜋−𝜓2(3823) cross section and the branching fraction ℬ[𝜓2(3823)→𝛾𝜒𝑐1]. For the first time, resonance structure is observed in the cross section line shape of 𝑒+𝑒−→𝜋+𝜋−𝜓2(3823) with significances exceeding 5𝜎. A fit to data with two coherent Breit-Wigner resonances modeling the √𝑠-dependent cross section yields 𝑀(𝑅1)=4406.9±17.2±4.5 MeV/𝑐2, Γ(𝑅1)=128.1±37.2±2.3 MeV, and 𝑀(𝑅2)=4647.9±8.6±0.8 MeV/𝑐2, Γ(𝑅2)=33.1±18.6±4.1 MeV. Though weakly disfavored by the data, a single resonance with 𝑀(𝑅)=4417.5±26.2±3.5 MeV/𝑐2, Γ(𝑅)=245±48±13 MeV is also possible to interpret data. This observation deepens our understanding of the nature of the vector charmoniumlike states. The mass of the 𝜓2(3823) state is measured as (3823.12±0.43±0.13) MeV/𝑐2, which is the most precise measurement to date.
The integrated luminosities of data samples collected in the BESIII experiment in 2016–2017 at center-of-mass energies between 4.19 and 4.28 GeV are measured with a precision better than 1% by analyzing large-angle Bhabha scattering events. The integrated luminosities of old datasets collected in 2010–2014 are updated by considering corrections related to detector performance, offsetting the effect of newly discovered readout errors in the electromagnetic calorimeter, which can haphazardly occur.