Refine
Year of publication
Document Type
- Article (446)
- Preprint (293)
- Part of Periodical (7)
- Doctoral Thesis (4)
- Conference Proceeding (3)
- Working Paper (3)
- Part of a Book (1)
- Master's Thesis (1)
Has Fulltext
- yes (758)
Is part of the Bibliography
- no (758)
Keywords
- BESIII (19)
- e +-e − Experiments (16)
- taxonomy (15)
- Branching fraction (12)
- Particle and Resonance Production (8)
- Fulgoroidea (7)
- Quarkonium (7)
- Charm Physics (6)
- Spectroscopy (6)
- morphology (6)
Institute
- Physik (527)
- Frankfurt Institute for Advanced Studies (FIAS) (142)
- Medizin (42)
- Informatik (31)
- Geowissenschaften (10)
- Biowissenschaften (7)
- ELEMENTS (7)
- Biochemie, Chemie und Pharmazie (5)
- Biochemie und Chemie (4)
- Institut für Ökologie, Evolution und Diversität (4)
Background. Intervertebral disc degeneration (IDD) at the cervicothoracic junction of spine is clinically relevant, however, little attention had been paid. T2 mapping and magnetic transfer ratio (MTR) are useful magnetic resonance imaging (MRI) techniques to quantitatively evaluate IDD, revealing the biochemical changes within the intervertebral disc. To compare T2 mapping with MTR imaging regarding their accuracy to quantitatively diagnose intervertebral disc degeneration at the cervicothoracic junction, influences of anatomical level, gender, age, and Pfrrmann grade of T2 relaxation time values and MTR values were evaluated.
Methods. Sixty-seven patients with neck and upper back pain were included and examined with both T2 mapping andMTR imaging. Te Pfrrmann grade, T2 relaxation time values, and MTR value of each disc between C7 and T3 were measured. Diferences were investigated among diferent segmental levels, genders, age ranges, and Pfrrmann grades. Te diagnostic accuracy of both MRI techniques was compared using the receiver operating characteristic (ROC) curves.
Results. No signifcant diference was detected comparing T2 relaxation time values or MTR values among diferent anatomical levels, genders, and segmental levels. And we generally found that T2 relaxation time values decreased, while MTR value increased with increasing age. Importantly, we demonstrated the signifcant correlation between either T2 relaxation time values or MTR value and Pfrrmann grade.
Conclusion. We proved the better accuracy of T2 mapping over MTR imaging to quantitatively evaluate the intervertebral disc degeneration of the cervicothoracic junction.
The present corrigendum corrects errors that occurred in: Zheng Y., Hu H., Chen D., Chen J., Zhang H. & Rasnitsyn A.P. 2021. New fossil records of Xyelidae (Hymenoptera) from the Middle Jurassic of Inner Mongolia, China. European Journal of Taxonomy 733: 146–159. https://doi.org/10.5852/ejt.2021.733.1229
This study aimed to appraise two quantitative magnetic resonance imaging techniques, T2* imaging and diffusion-weighted imaging (DWI), for the diagnosis of the intervertebral disc degeneration of the cervico-thoracic junction. Influence of specific factors and diagnostic accuracy of both techniques were particularly explored. Sixty-one volunteers with neck and upper back pain were recruited and evaluated with both T2* imaging and DWI. The Pfirrmann grade, T2* relaxation time and apparent diffusion coefficient (ADC) value of each disc between C7 and T3 were recorded. Stratified analyses were performed for different anatomic levels, genders, age ranges and Pfirrmann grades. The diagnostic accuracy of both techniques was investigated using the receiver operating characteristic (ROC) curves. No statistically significant difference of either T2* relaxation time or ADC value was detected between males and females. Both parameters decreased with the increasing age and Pfirrmann grade. The ROC curves showed the higher sensitivity and specificity for T2* imaging than DWI to quantitatively identify the disc degeneration. Particularly, T2* imaging allowed for a quantitative distinguishing the normal, mild and moderate disc degeneration from the severe degeneration, which was unable to accomplish with DWI. In conclusion, we demonstrated that T2* imaging possess a better accuracy than DWI to quantitatively diagnose the intervertebral disc degeneration at the cervico-thoracic junction.
Dihadron angular correlations in d + Au collisions at √sNN = 200 GeV are reported as a function of the measured zero-degree calorimeter neutral energy and the forward charged hadron multiplicity in the Au-beam direction. A finite correlated yield is observed at large relative pseudorapidity (η) on the near side (i.e. relative azimuth φ ∼ 0). This correlated yield as a function of η appears to scale with the dominant, primarily jet-related, away-side (φ ∼ π) yield. The Fourier coefficients of the φ correlation, Vn = (cosnφ), have a strong η dependence. In addition, it is found that V1 is approximately inversely proportional to the mid-rapidity event multiplicity, while V2 is independent of it with similar magnitude in the forward (d-going) and backward (Au-going) directions.
The results from the STAR Collaboration on directed flow (v1), elliptic flow (v2), and the fourth harmonic (v4) in the anisotropic azimuthal distribution of particles from Au+Au collisions at sqrt[sNN]=200GeV are summarized and compared with results from other experiments and theoretical models. Results for identified particles are presented and fit with a blast-wave model. Different anisotropic flow analysis methods are compared and nonflow effects are extracted from the data. For v2, scaling with the number of constituent quarks and parton coalescence are discussed. For v4, scaling with v22 and quark coalescence are discussed.
We present a systematic analysis of two-pion interferometry in Au+Au collisions at sqrt[sNN]=200GeV using the STAR detector at Relativistic Heavy Ion Collider. We extract the Hanbury-Brown and Twiss radii and study their multiplicity, transverse momentum, and azimuthal angle dependence. The Gaussianness of the correlation function is studied. Estimates of the geometrical and dynamical structure of the freeze-out source are extracted by fits with blast-wave parametrizations. The expansion of the source and its relation with the initial energy density distribution is studied.
Non-standard errors
(2021)
In statistics, samples are drawn from a population in a data-generating process (DGP). Standard errors measure the uncertainty in sample estimates of population parameters. In science, evidence is generated to test hypotheses in an evidence-generating process (EGP). We claim that EGP variation across researchers adds uncertainty: non-standard errors. To study them, we let 164 teams test six hypotheses on the same sample. We find that non-standard errors are sizeable, on par with standard errors. Their size (i) co-varies only weakly with team merits, reproducibility, or peer rating, (ii) declines significantly after peer-feedback, and (iii) is underestimated by participants.
Quark interactions with topological gluon configurations can induce chirality imbalance and local parity violation in quantum chromodynamics. This can lead to electric charge separation along the strong magnetic field in relativistic heavy-ion collisions – the chiral magnetic effect (CME). We report measurements by the STAR collaboration of a CME-sensitive observable in p + Au and d + Au collisions at 200 GeV, where the CME is not expected, using charge-dependent pair correlations relative to a third particle. We observe strong charge-dependent correlations similar to those measured in heavy-ion collisions. This bears important implications for the interpretation of the heavy-ion data.
Thought to be monotypic for decades, the only species in the goosefish genus Lophiomus Gill, Lm. setigerus (Vahl), shows a wide range of morphological variation and is distributed widely in the Indo-West Pacific (IWP). In this study, datasets for two mitochondrial and two nuclear genes sequences obtained from samples of Lophiomus collected in different localities across the IWP were constructed and analyzed to explore the phylogeny and species diversity within the genus. Our integrated approach with multiline evidence unveiled an unanticipated richness of at least six delimited species of Lophiomus. Herein, based on materials already available from museums and new specimens obtained primarily through the Tropical Deep-Sea Benthos program surveying IWP benthic fauna, we formally describe three new species: Lm. immaculioralis sp. nov., Lm. nigriventris sp. nov., and Lm. carusoi sp. nov. Also, we resurrect Lm. laticeps stat. rev. from synonyms of Lm. setigerus. These species can be diagnosed by genetics, body coloration, patterns on the floor of the mouth, peritoneum pigmentation, morphometric measurements, and meristic counts of cranial spines, dorsal-fin spines, and pectoral-fin and pelvic-fin rays from each other and from Lm. setigerus. The species Lm. setigerus, as well as the genus Lophiomus, are re-described accordingly based on the new results. Amended identification keys to the four extant lophiid genera and to species of Lophiomus are also provided.