Refine
Document Type
- Article (7)
- Preprint (2)
- Doctoral Thesis (1)
Language
- English (10)
Has Fulltext
- yes (10)
Is part of the Bibliography
- no (10)
Keywords
- Computed tomography (3)
- Bone density (1)
- Bone diseases (1)
- CAC-DRS Score (1)
- Collagen Maps (1)
- Computed Tomography (1)
- Coronary Heart Disease (1)
- Coronary Plaque Burden (1)
- DECT (1)
- Diagnostic accuracy (1)
- Endovascular aortic repair (1)
- Gastrointestinal (1)
- Lumbar Disk Degeneration (1)
- Medical Physics: Diagnostic (1)
- Osteoporosis (1)
- Post-processing (1)
- Pseudarthrosis (1)
- SARS-CoV-2 Pneumonia (1)
- Spine (1)
- Thoracic aortic aneurysm (1)
- Workstation comparison (1)
- X-ray computed tomography (1)
- angiography (1)
- biopsy (1)
- ethiodized oil (1)
- in vivo dosimetry (1)
- liver (1)
- radiation dosage (1)
- radiation dosimetry (1)
- radiation protection (1)
This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95–23.01) to 2.36 μSv (IQR, 0.52–12.66) (−36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 μSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 μSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (−30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.
Tidal deformability of fermion-boson stars: neutron stars admixed with ultralight dark matter
(2023)
In this work we investigate the tidal deformability of a neutron star admixed with dark matter, modeled as a massive, self-interacting, complex scalar field. We derive the equations to compute the tidal deformability of the full Einstein-Hilbert-Klein-Gordon system self-consistently, and probe the influence of the scalar field mass and self-interaction strength on the total mass and tidal properties of the combined system. We find that dark matter core-like configurations lead to more compact objects with smaller tidal deformability, and dark matter cloud-like configurations lead to larger tidal deformability. Electromagnetic observations of certain cloud-like configurations would appear to violate the Buchdahl limit. The self-interaction strength is found to have a significant effect on both mass and tidal deformability. We discuss observational constraints and the connection to anomalous detections. We also investigate how this model compares to those with an effective bosonic equation of state and find the interaction strength where they converge sufficiently.
Objectives: To assess the impact of noise-optimised virtual monoenergetic imaging (VMI+) on image quality and diagnostic evaluation in abdominal dual-energy CT scans with impaired portal-venous contrast.
Methods: We screened 11,746 patients who underwent portal-venous abdominal dual-energy CT for cancer staging between 08/2014 and 11/2019 and identified those with poor portal-venous contrast.
Standard linearly-blended image series and VMI+ image series at 40, 50, and 60 keV were reconstructed. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of abdominal organs and vascular structures were calculated. Image noise, image contrast and overall image quality were rated by three radiologists using 5-point Likert scale.
Results: 452 of 11,746 (4%) exams were poorly opacified. We excluded 190 cases due to incomplete datasets or multiple exams of the same patient with a final study group of 262. Highest CNR values in all abdominal organs (liver, 6.4 ± 3.0; kidney, 17.4 ± 7.5; spleen, 8.0 ± 3.5) and vascular structures (aorta, 16.0 ± 7.3; intrahepatic vein, 11.3 ± 4.7; portal vein, 15.5 ± 6.7) were measured at 40 keV VMI+ with significantly superior values compared to all other series. In subjective analysis, highest image contrast was seen at 40 keV VMI+ (4.8 ± 0.4), whereas overall image quality peaked at 50 keV VMI+ (4.2 ± 0.5) with significantly superior results compared to all other series (p < 0.001).
Conclusions: Image reconstruction using VMI+ algorithm at 50 keV significantly improves image contrast and image quality of originally poorly opacified abdominal CT scans and reduces the number of non-diagnostic scans.
Advances in knowledge: We validated the impact of VMI+ reconstructions in poorly attenuated DECT studies of the abdomen in a big data cohort.
Rationale and Objectives: Lumbar disk degeneration is a common condition contributing significantly to back pain. The objective of the study was to evaluate the potential of dual-energy CT (DECT)-derived collagen maps for the assessment of lumbar disk degeneration.
Patients and Methods: We conducted a retrospective analysis of 127 patients who underwent dual-source DECT and MRI of the lumbar spine between 07/2019 and 10/2022. The level of lumbar disk degeneration was categorized by three radiologists as follows: no/mild (Pfirrmann 1&2), moderate (Pfirrmann 3&4), and severe (Pfirrmann 5). Recall (sensitivity) and accuracy of DECT collagen maps were calculated. Intraclass correlation coefficient (ICC) was used to evaluate inter-reader reliability. Subjective evaluations were performed using 5-point Likert scales for diagnostic confidence and image quality.
Results: We evaluated a total of 762 intervertebral disks from 127 patients (median age, 69.7 (range, 23.0–93.7), female, 56). MRI identified 230 non/mildly degenerated disks (30.2%), 484 moderately degenerated disks (63.5%), and 48 severely degenerated disks (6.3%). DECT collagen maps yielded an overall accuracy of 85.5% (1955/2286). Recall (sensitivity) was 79.3% (547/690) for the detection of no/mild lumbar disk degeneration, 88.7% (1288/1452) for the detection of moderate disk degeneration, and 83.3% (120/144) for the detection of severe disk degeneration (ICC = 0.9). Subjective evaluations of DECT collagen maps showed high diagnostic confidence (median 4) and good image quality (median 4).
Conclusion: The use of DECT collagen maps to distinguish different stages of lumbar disk degeneration may have clinical significance in the early diagnosis of disk-related pathologies in patients with contraindications for MRI or in cases of unavailability of MRI.
Rationale and Objectives: Bone non-union is a serious complication of distal radius fractures (DRF) that can result in functional limitations and persistent pain. However, no accepted method has been established to identify patients at risk of developing bone non-union yet. This study aimed to compare various CT-derived metrics for bone mineral density (BMD) assessment to identify predictive values for the development of bone non-union.
Materials and Methods: CT images of 192 patients with DRFs who underwent unenhanced dual-energy CT (DECT) of the distal radius between 03/2016 and 12/2020 were retrospectively identified. Available follow-up imaging and medical health records were evaluated to determine the occurrence of bone non-union. DECT-based BMD, trabecular Hounsfield unit (HU), cortical HU and cortical thickness ratio were measured in normalized non-fractured segments of the distal radius.
Results: Patients who developed bone non-union were significantly older (median age 72 years vs. 54 years) and had a significantly lower DECT-based BMD (median 68.1 mg/cm3 vs. 94.6 mg/cm3, p < 0.001). Other metrics (cortical thickness ratio, cortical HU, trabecular HU) showed no significant differences. ROC and PR curve analyses confirmed the highest diagnostic accuracy for DECT-based BMD with an area under the curve (AUC) of 0.83 for the ROC curve and an AUC of 0.46 for the PR curve. In logistic regression models, DECT-based BMD was the sole metric significantly associated with bone non-union.
Conclusion: DECT-derived metrics can accurately predict bone non-union in patients who sustained DRF. The diagnostic performance of DECT-based BMD is superior to that of HU-based metrics and cortical thickness ratio.
Highlights
• Assessment of coronary artery plaque burden according to the CAC-DRS Score correlated well with pulmonary involvement of SARS-CoV-2 pneumonia (min. r=0.81, 95% CI 0.76 to 0.86).
• Visual and quantitative CAC-DRS Score of coronary artery plaque burden provided independent prognostic information on all-cause mortality in patients with SARS-CoV-2 pneumonia (p=0.0016 and p<0.0001, respectively).
• Incorporating CAC-DRS Score and pulmonary involvement into clinical decision making revealed great potential to discriminate patients with fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89 to 0.97) and the need for intensive care treatment (AUC 0.801, 95% CI 0.77 to 0.83).
Purpose: To assess and correlate pulmonary involvement and outcome of SARS-CoV-2 pneumonia with the degree of coronary plaque burden based on the CAC-DRS classification (Coronary Artery Calcium Data and Reporting System).
Methods: This retrospective study included 142 patients with confirmed SARS-CoV-2 pneumonia (58 ± 16 years; 57 women) who underwent non-contrast CT between January 2020 and August 2021 and were followed up for 129 ± 72 days. One experienced blinded radiologist analyzed CT series for the presence and extent of calcified plaque burden according to the visual and quantitative HU-based CAC-DRS Score. Pulmonary involvement was automatically evaluated with a dedicated software prototype by another two experienced radiologists and expressed as Opacity Score.
Results: CAC-DRS Scores derived from visual and quantitative image evaluation correlated well with the Opacity Score (r=0.81, 95% CI 0.76-0.86, and r=0.83, 95% CI 0.77-0.89, respectively; p<0.0001) with higher correlation in severe than in mild stage SARS-CoV-2 pneumonia (p<0.0001). Combined, CAC-DRS and Opacity Scores revealed great potential to discriminate fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89-0.97), and the need for intensive care treatment (AUC 0.801, 95% CI 0.77-0.83). Visual and quantitative CAC-DRS Scores provided independent prognostic information on all-cause mortality (p=0.0016 and p<0.0001, respectively), both in univariate and multivariate analysis.
Conclusions: Coronary plaque burden is strongly correlated to pulmonary involvement, adverse outcome, and death due to respiratory failure in patients with SARS-CoV-2 pneumonia, offering great potential to identify individuals at high risk.
Purpose: To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography scans (CTA) or a specifically designed phantom model.
Methods: This retrospective study included 23 patients with confirmed TAA on routinely performed CTAs. In addition to phantom tube diameters, one experienced blinded radiologist evaluated the dimensions of TAAs on three different workstations in two separate rounds. Precision was assessed by calculating measurement errors. In addition, correlation analysis was performed using Pearson correlation.
Results: Measurements acquired at the Siemens workstation deviated by 3.54% (range, 2.78–4.03%; p = 0.14) from the true size, those at General Electric by 4.05% (range, 1.46–7.09%; p < 0.0001), and at TeraRecon by 4.86% (range, 3.22–6.45%; p < 0.0001). Accordingly, Siemens provided the most precise workstation at simultaneously most fluctuating values (scattering of 4.46%). TeraRecon had the smallest fluctuation (scattering of 2.83%), but the largest deviation from the true size of the phantom. The workstation from General Electric showed a scattering of 2.94%. The highest overall correlation between the 1st and 2nd rounds was observed with measurements from Siemens (r = 0.898), followed by TeraRecon (r = 0.799), and General Electric (r = 0.703). Repetition of measurements reduced processing times by 40% when using General Electric, by 20% with Siemens, and by 18% with TeraRecon.
Conclusions: In conclusion, all three workstations facilitated precise assessment of dimensions in the majority of cases at simultaneously high reproducibility, ensuring accurate pre-interventional planning of thoracic endovascular aortic repair.
Tidal deformability of fermion-boson stars: neutron stars admixed with ultralight dark matter
(2023)
In this work we investigate the tidal deformability of a neutron star admixed with dark matter, modeled as a massive, self-interacting, complex scalar field. We derive the equations to compute the tidal deformability of the full Einstein-Hilbert-Klein-Gordon system self-consistently, and probe the influence of the scalar field mass and self-interaction strength on the total mass and tidal properties of the combined system. We find that dark matter core-like configurations lead to more compact objects with smaller tidal deformability, and dark matter cloud-like configurations lead to larger tidal deformability. Electromagnetic observations of certain cloud-like configurations would appear to violate the Buchdahl limit. The self-interaction strength is found to have a significant effect on both mass and tidal deformability. We discuss observational constraints and the connection to anomalous detections. We also investigate how this model compares to those with an effective bosonic equation of state and find the interaction strength where they converge sufficiently.
Neutron stars are unique laboratories for the investigation of the high density properties of bulk matter. In this work, the astrophysical constraints for a phase transition from hadronic matter to deconfined quark matter are examined thoroughly. A scheme for relating known astrophysical observables such as mass, radius and tidal deformability to the parameter space of such a transition is devised and applied to the set of data currently available.
In order to span a wide parameter space, a highly parameterizable relativistic mean field equation in compliance with chiral effective field theory results is used, where the stiffness of the equation of state can be varied via the effective mass at saturation density. The phase transitions are modelled using a Maxwell construction and assumed to be of first order, with a constant speed of sound quark matter model. The resulting equations of state are analyzed and divided into four categories, which can be used to constrain the parameter space that allows phase transition. It is highlighted, that a subset of this parameter space would even be detectable without the need of higher precision measurements. A phase transition at high densities is shown to be particularly promising in this regard. Finally, the groundwork is laid to apply the equation of state used in this work for supernova or merger simulations, by extending it to non-zero temperatures.
Background: While computed tomography (CT)-guided liver biopsies are commonly performed using unenhanced images, contrast-enhanced images are beneficial for challenging puncture pathways and lesion locations. This study aimed to evaluate the accuracy of CT-guided biopsies for intrahepatic lesions using unenhanced, intravenous (IV)-enhanced, or intra-arterial Lipiodol-marked CT for lesion marking.
Patients and methods: Six-hundred-seven patients (men: 358 [59.0%], mean age 61 years; SD ±12.04) with suspect hepatic lesions and CT-guided liver biopsies were retrospectively evaluated. Successful biopsies were histopathological findings other than typical liver tissue or non-specific findings. Data was ascertained regarding the use of contrast medium for the biopsy-planning CT, unenhanced (group 1) vs. Lipiodol (group 2) vs. IV contrast (group 3). Technical success and influencing factors were insulated. Complications were noted. The results were analyzed using the Wilcoxon-Man-Whitney t-test, Chi-square test, and Spearman-Rho.
Results: Overall lesion hitting rate was 73.1%, with significantly better rates using Lipiodol-marked lesions (79.3%) compared to group 1 (73.8%) and group 3 (65.2%) (p = 0.037). Smaller lesions (<20 mm diameter) benefited significantly from Lipiodol-marking with 71.2% successful biopsy rate compared to group 1 (65.5%) and group 3 (47.7%) (p = 0.021). Liver cirrhosis (p = 0.94) and entity of parenchymal lesions (p = 0.78) had no impact on the hitting rate between the groups. No major complications occurred during the interventions.
Conclusions: Pre-biopsy Lipiodol marking of suspect hepatic lesions significantly increases the lesion-hitting rate and is especially beneficial for biopsy of smaller targets below 20 mm diameter. Further, Lipiodol marking is superior to IV contrast for non-visible lesions in unenhanced CT. Target lesion entity has no impact on the hitting rate.