Refine
Language
- English (13)
Has Fulltext
- yes (13)
Is part of the Bibliography
- no (13)
Keywords
- Experimental nuclear physics (2)
- Experimental particle physics (2)
- ADAMTS-13 (1)
- Anemia (1)
- Aortic valve (1)
- Aortic valve replacement (1)
- Bleeding (1)
- Blood loss (1)
- Blood transfusion (1)
- Difficult Airway Management (1)
Institute
- Medizin (7)
- Physik (6)
- Frankfurt Institute for Advanced Studies (FIAS) (5)
- Informatik (2)
- Informatik und Mathematik (2)
We present the first measurement of event-by-event fluctuations in the kaon sector in Pb – Pb collisions at √sNN = 2.76 TeV with the ALICE detector at the LHC. The robust fluctuation correlator νdyn is used to evaluate the magnitude of fluctuations of the relative yields of neutral and charged kaons, as well as the relative yields of charged kaons, as a function of collision centrality and selected kinematic ranges. While the correlator νdyn[K+,K−] exhibits a scaling approximately in inverse proportion of the charged particle multiplicity, νdyn[K0 S ,K±] features a significant deviation from such scaling. Within uncertainties, the value of νdyn[K0 S ,K±] is independent of the selected transverse momentum interval, while it exhibits a pseudorapidity dependence. The results are compared with HIJING, AMPT and EPOS–LHC predictions, and are further discussed in the context of the possible production of disoriented chiral condensates in central Pb – Pb collisions.
In particle collider experiments, elementary particle interactions with large momentum transfer produce quarks and gluons (known as partons) whose evolution is governed by the strong force, as described by the theory of quantum chromodynamics (QCD)1. These partons subsequently emit further partons in a process that can be described as a parton shower2, which culminates in the formation of detectable hadrons. Studying the pattern of the parton shower is one of the key experimental tools for testing QCD. This pattern is expected to depend on the mass of the initiating parton, through a phenomenon known as the dead-cone effect, which predicts a suppression of the gluon spectrum emitted by a heavy quark of mass mQ and energy E, within a cone of angular size mQ/E around the emitter3. Previously, a direct observation of the dead-cone effect in QCD had not been possible, owing to the challenge of reconstructing the cascading quarks and gluons from the experimentally accessible hadrons. We report the direct observation of the QCD dead cone by using new iterative declustering techniques4,5 to reconstruct the parton shower of charm quarks. This result confirms a fundamental feature of QCD. Furthermore, the measurement of a dead-cone angle constitutes a direct experimental observation of the non-zero mass of the charm quark, which is a fundamental constant in the standard model of particle physics.
Measurements of event-by-event fluctuations of charged-particle multiplicities in Pb–Pb collisions at sNN−−−√ = 2.76 TeV using the ALICE detector at the CERN Large Hadron Collider (LHC) are presented in the pseudorapidity range |η|<0.8 and transverse momentum 0.2<pT<2.0 GeV/c. The amplitude of the fluctuations is expressed in terms of the variance normalized by the mean of the multiplicity distribution. The η and pT dependences of the fluctuations and their evolution with respect to collision centrality are investigated. The multiplicity fluctuations tend to decrease from peripheral to central collisions. The results are compared to those obtained from HIJING and AMPT Monte Carlo event generators as well as to experimental data at lower collision energies. Additionally, the measured multiplicity fluctuations are discussed in the context of the isothermal compressibility of the high-density strongly-interacting system formed in central Pb–Pb collisions.
In our Galaxy, light antinuclei composed of antiprotons and antineutrons can be produced through high-energy cosmic-ray collisions with the interstellar medium or could also originate from the annihilation of dark-matter particles that have not yet been discovered. On Earth, the only way to produce and study antinuclei with high precision is to create them at high-energy particle accelerators. Although the properties of elementary antiparticles have been studied in detail, the knowledge of the interaction of light antinuclei with matter is limited. We determine the disappearance probability of 3He¯¯¯¯¯¯ when it encounters matter particles and annihilates or disintegrates within the ALICE detector at the Large Hadron Collider. We extract the inelastic interaction cross section, which is then used as input to calculations of the transparency of our Galaxy to the propagation of 3He¯¯¯¯¯¯ stemming from dark-matter annihilation and cosmic-ray interactions within the interstellar medium. For a specific dark-matter profile, we estimate a transparency of about 50%, whereas it varies with increasing 3He¯¯¯¯¯¯ momentum from 25% to 90% for cosmic-ray sources. The results indicate that 3He¯¯¯¯¯¯ nuclei can travel long distances in the Galaxy, and can be used to study cosmic-ray interactions and dark-matter annihilation.
Antimatter particles such as positrons and antiprotons abound in the cosmos. Much less common are light antinuclei, composed of antiprotons and antineutrons, which can be produced in our galaxy via high-energy cosmic-ray collisions with the interstellar medium or could also originate from the annihilation of the still undiscovered dark-matter particles. On Earth, the only way to produce and study antinuclei with high precision is to create them at high-energy particle accelerators like the Large Hadron Collider (LHC). Though the properties of elementary antiparticles have been studied in detail, knowledge of the interaction of light antinuclei with matter is rather limited. This work focuses on the determination of the disappearance probability of \ahe\ when it encounters matter particles and annihilates or disintegrates. The material of the ALICE detector at the LHC serves as a target to extract the inelastic cross section for \ahe\ in the momentum range of 1.17≤p<10 GeV/c. This inelastic cross section is measured for the first time and is used as an essential input to calculations of the transparency of our galaxy to the propagation of 3He¯¯¯¯¯¯ stemming from dark-matter decays and cosmic-ray interactions within the interstellar medium. A transparency of about 50% is estimated using the GALPROP program for a specific dark-matter profile and a standard set of propagation parameters. For cosmic-ray sources, the obtained transparency with the same propagation scheme varies with increasing 3He¯¯¯¯¯¯ momentum from 25% to 90%. The absolute uncertainties associated to the 3He¯¯¯¯¯¯ inelastic cross section measurements are of the order of 10%−15%. The reported results indicate that 3He¯¯¯¯¯¯ nuclei can travel long distances in the galaxy, and can be used to study cosmic-ray interactions and dark-matter decays.
Background. Tracheal intubation still represents the "gold standard" in securing the airway of unconscious patients in the prehospital setting. Especially in cases of restricted access to the patient, video laryngoscopy became more and more relevant.
Objectives. The aim of the study was to evaluate the performance and intubation success of four different video laryngoscopes, one optical laryngoscope, and a Macintosh blade while intubating from two different positions in a mannequin trial with difficult access to the patient.
Methods. A mannequin with a cervical collar was placed on the driver’s seat. Intubation was performed with six different laryngoscopes either through the driver’s window or from the backseat. Success, C/L score, time to best view (TTBV), time to intubation (TTI), and number of attempts were measured. All participants were asked to rate their favored device.
Results. Forty-two physicians participated. 100% of all intubations performed from the backseat were successful. Intubation success through the driver’s window was less successful. Only with the Airtraq® optical laryngoscope, 100% success was achieved. Best visualization (window C/L 2a; backseat C/L 2a) and shortest TTBV (window 4.7 s; backseat 4.1 s) were obtained when using the D-Blade video laryngoscope, but this was not associated with a higher success through the driver’s window. Fastest TTI was achieved through the window (14.2 s) when using the C-MAC video laryngoscope and from the backseat (7.3 s) when using a Macintosh blade.
Conclusions. Video laryngoscopy revealed better results in visualization but was not associated with a higher success. Success depended on the approach and familiarity with the device. We believe that video laryngoscopy is suitable for securing airways in trapped accident victims. The decision for an optimal device is complicated and should be based upon experience and regular training with the device.
OBJECTIVE: The role of supraglottic airway devices in emergency airway management is highlighted in international airway management guidelines. We evaluated the application of the new generation laryngeal tube suction (LTS-II/LTS-D) in the management of in-hospital unexpected difficult airway and cardiopulmonary resuscitation.
METHODS: During a seven-year period, patients treated with a laryngeal tube who received routine anesthesia and had an unexpected difficult airway (Cormack Lehane Grade 3-4), who underwent cardiopulmonary resuscitation, or who underwent cardiopulmonary resuscitation outside the operating room and had a difficult airway were evaluated. Successful placement of the LTS II/LTS-D, sufficient ventilation, time to placement, number of placement attempts, stomach content, peripheral oxygen saturation/end-tidal carbon dioxide development (SpO2/etCO2) over 5 minutes, subjective overall assessment and complications were recorded.
RESULTS: In total, 106 adult patients were treated using an LTS-II/LTS-D. The main indication for placement was a difficult airway (75%, n=80), followed by cardiopulmonary resuscitation (25%, n=26) or an overlap between both (18%, n=19). In 94% of patients (n=100), users placed the laryngeal tube during the first attempt. In 93% of patients (n=98), the tube was placed within 30 seconds. A significant increase in SpO2 from 97% (0-100) to 99% (5-100) was observed in the whole population and in cardiopulmonary resuscitation patients. The average initial etCO2 of 39.5 mmHg (0-100 mmHg) decreased significantly to an average of 38.4 mmHg (10-62 mmHg) after 5 minutes. A comparison of cardiopulmonary resuscitation patients with non-cardiopulmonary resuscitation patients regarding gastric contents showed no significant difference.
CONCLUSIONS: LTS-D/LTS-II use for in-hospital unexpected difficult airway management provides a secure method for primary airway management until other options such as video laryngoscopy or fiber optic intubation become available.
Background: Acute bleeding requires fast and targeted therapy. Therefore, knowledge of the patient's potential to form a clot is crucial. Point-of-care testing (POCT) provides fast and reliable information on coagulation. Structural circumstances, such as person-bound sample transport, can prolong the reporting of the results. The aim of the present study was to investigate the diagnostic quality and accuracy between POCT INR diagnostics and standard laboratory analysis (SLA) as well as the time advantage between a pneumatic tube and a personal-based transport system. Methods: Two groups of haemorrhagic patients (EG: emergency department; OG: delivery room; each n = 12) were examined in the context of bleeding emergencies using POCT and SLA. Samples were transported via a pneumatic tube system or by a personal transport service. Results: INR results between POCT and SLA showed a high and significant correlation (EG: p < 0.001; OG: p < 0.001). POCT results were reported significantly more quickly (EG: 1.1 vs. 39.6 min; OG: 2.0 vs. 75.0 min; p < 0.001) and required less time for analysis (EG: 0.3 vs. 24.0 min; OG: 0.5 vs. 45.0 min; p < 0.001) compared to SLA. The time for transportation with the pneumatic tube was significantly shorter (8.0 vs. 18.5 min; p < 0.001) than with the personal-based transport system. Conclusion: The results of the present study suggest that POCT may be a suitable method for the emergency diagnosis and may be used as prognostic diagnostic elements in haemotherapy algorithms to initiate targeted haemotherapy at an early point in time.
Postoperative thrombotic thrombocytopenic purpura (TTP) shows clinical presentation similar to classical TTP, whereas exact pathophysiological contexts remain unexplained. In this study, we investigated intraoperative and postoperative changes in ADAMTS-13 (a disintegrin and metalloprotease with thrombospondin type 1 motifs, member 13), von Willebrand factor (VWF), large VWF multimers, and interleukin-6 (IL-6) in vascular surgery patients. The objective was to compare the impact of endovascular, peripheral, and aortic surgery on target parameters which are supposed to play a role in surgery-associated TTP. A total of 93 vascular surgery patients were included and divided into 4 groups according to the specific type of intervention they underwent. Blood samples were taken preoperatively, intraoperatively, and postoperatively on days 2 and 4. The ADAMTS-13 activity decreased significantly in 3 of the 4 groups during surgery (from median 81% to 49%, P < .001, in the group undergoing aortoiliacal interventions), whereas the percentage of large VWF multimers increased in all groups of patients. von Willebrand factor antigen increased significantly in all groups on postoperative day 2 and IL-6 increased significantly in the intraoperative and early postoperative period. There was no significant correlation between the intraoperative decrease in ADAMTS-13 and the increase in VWF or IL-6. No patient in this study showed clinical picture of TTP; the precise cause and clinical significance of moderately reduced ADAMTS-13 activity in the perioperative setting have not yet been definitely determined.
More than 30% of the world's population are anemic with serious economic consequences including reduced work capacity and other obstacles to national welfare and development. Red blood cell transfusion is the mainstay to correct anemia, but it is also 1 of the top 5 overused procedures. Patient blood management (PBM) is a proactive, patient-centered, and multidisciplinary approach to manage anemia, optimize hemostasis, minimize iatrogenic blood loss, and harness tolerance to anemia. Although the World Health Organization has endorsed PBM in 2010, many hospitals still seek guidance with the implementation of PBM in clinical routine. Given the use of proven change management principles, we propose simple, cost-effective measures enabling any hospital to reduce both anemia and red blood cell transfusions in surgical and medical patients. This article provides comprehensive bundles of PBM components encompassing 107 different PBM measures, divided into 6 bundle blocks acting as a working template to develop institutions' individual PBM practices for hospitals beginning a program or trying to improve an already existing program. A stepwise selection of the most feasible measures will facilitate the implementation of PBM. In this manner, PBM represents a new quality and safety standard.
Background: Conditions during blood product storage and transportation should maintain quality. The aim of this in vitro study was to investigate the effect of interruption of agitation, temporary cooling (TC), and pneumatic tube system transportation (PTST) on the aggregation ability (AA) and mitochondrial function (MF) of platelet concentrates (PC).
Study Design and Methods: A PC was divided equally into four subunits and then allocated to four test groups. The control group (I) was stored as recommended (continuous agitation, 22 ± 2°C) for 4 days. The test groups were stored without agitation (II), stored as recommended, albeit 4°C for 60 minutes on day (d)2 (III) and PTST (IV). Aggregometry was measured using Multiplate (RocheAG; ADPtest, ASPItest, TRAPtest, COLtest) and MF using Oxygraph‐2k (Oroboros Instruments). The basal and maximum mitochondrial respiratory rate (MMRR) were determined. AA and MF were measured daily in I and II and AA in III and IV on d2 after TC/PTST. Statistical analysis was performed using tests for matched observations.
Results: Eleven PCs were used. TRAP‐6 induced AA was significantly lower in II when compared to I on d4 (P = 0.015*). In III the ASPItest was significantly lower (P = 0.032*). IV showed no significant differences. The basal and MMRR were significantly reduced over 4 days in I and II (for both rates in both groups: P = <0.0001*). No significant differences occurred on d4 (P = 0.495).
Conclusion: Our results indicate that ex vivo AA and MF of PCs are unaffected, even in no‐ideal storage and transport circumstances with respect to agitation, temperature, and force.
Background: The aim of this study was to compare outcome of patients with previous cardiac surgery undergoing transapical aortic valve implantation (Redo-TAVI) to those undergoing classic aortic valve replacement (Redo-AVR) by using propensity analysis.
Methods: From January 2005 through May 2012, 52 high-risk patients underwent Redo-TAVI using a pericardial xenograft fixed within a stainless steel, balloon-expandable stent (Edwards SAPIEN™). During the same period of time 167 patients underwent classic Redo-AVR. Logistic regression analysis was used to identify covariates among 11 baseline patient variables including the type of initial surgery. Using the significant regression coefficients, each patient’s propensity score was calculated, allowing selectively matched subgroups of 40 patients each. Initial surgery included coronary artery bypass grafting in 30 patients, aortic valve replacement in 7 patients and mitral valve reconstruction in 3 patients in each group. Follow-up was 4 ± 2 years and was 100% complete.
Results: Postoperative chest tube drainage (163 ± 214 vs. 562 ± 332 ml/24 h, p = 0.02) and incidence of early permanent neurologic deficit (0 vs. 13%, p = 0.04) was lower in patients with Redo-TAVI and there was a trend towards improved 30-day survival (p = 0.06). Also we detected a decreased ventilation time (p = 0.04) and lower transfusion rate of allogenic blood products (p ≤ 0.05) in the Redo-TAVI group. At late follow up differences regarding incidence of major adverse events, including death and permanent neurologic deficits (25% vs. 43%, p = 0.01) statistically supported early postoperative findings.
Conclusion: The encouraging results regarding early and long-term outcomes following TAVI in patients with previous cardiac surgery show, that this evolving approach may be particularly beneficial in this patient cohort.