Refine
Year of publication
Document Type
- Preprint (692)
- Article (508)
- Conference Proceeding (3)
- Working Paper (1)
Has Fulltext
- yes (1204)
Is part of the Bibliography
- no (1204)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron Scattering (11)
- Hadron-Hadron scattering (experiments) (11)
- LHC (9)
- Heavy-ion collision (6)
- HIV (5)
- ALICE experiment (4)
- Collective Flow (4)
- Jets (4)
- Quark-Gluon Plasma (4)
Institute
- Physik (1092)
- Frankfurt Institute for Advanced Studies (FIAS) (961)
- Informatik (924)
- Medizin (72)
- Geowissenschaften (12)
- Biochemie und Chemie (7)
- Biowissenschaften (5)
- Institut für Ökologie, Evolution und Diversität (4)
- ELEMENTS (3)
- Informatik und Mathematik (3)
The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.
This paper reports on Monte Carlo simulation results for future measurements of the moduli of time-like proton electromagnetic form factors, |GE | and |GM|, using the ¯pp → μ+μ− reaction at PANDA (FAIR). The electromagnetic form factors are fundamental quantities parameterizing the electric and magnetic structure of hadrons. This work estimates the statistical and total accuracy with which the form factors can be measured at PANDA, using an analysis of simulated data within the PandaRoot software framework. The most crucial background channel is ¯pp → π+π−,due to the very similar behavior of muons and pions in the detector. The suppression factors are evaluated for this and all other relevant background channels at different values of antiproton beam momentum. The signal/background separation is based on a multivariate analysis, using the Boosted Decision Trees method. An expected background subtraction is included in this study, based on realistic angular distribuations of the background contribution. Systematic uncertainties are considered and the relative total uncertainties of the form factor measurements are presented.
Background: Accurate assessment of hepatic fibrosis in patients with chronic HBeAg-negative Hepatitis B is of crucial importance not only to predict the long-term clinical course, but also to evaluate antiviral therapy indication. The aim of this study was to prospectively assess the utility of point shear wave elastography (pSWE) for longitudinal non-invasive fibrosis assessment in a large cohort of untreated patients with chronic HBeAg-negative hepatitis B virus (HBV) infection.
Methods: 407 consecutive patients with HBeAg-negative HBV infection who underwent pSWE, transient elastography (TE) as well as laboratory fibrosis markers, including fibrosis index based on four factors (FIB-4), aspartate to platelet ratio index (APRI) and FibroTest, on the same day were prospectively followed up for six years. Patients were classified into one of the three groups: inactive carriers (IC; HBV-DNA <2000 IU/mL and ALT <40 U/L); grey zone group 1 (GZ-1; HBV DNA <2000 IU/mL and ALT >40 U/L); grey zone group 2 (GZ-2; HBV-DNA >2000 IU/mL and ALT <40 U/L).
Results: pSWE results were significantly correlated with TE (r = 0.29, p < 0.001) and APRI (r = 0.17; p = 0.005). Median pSWE values did not differ between IC, GZ-1 and GZ-2 patients (p = 0.82, p = 0.17, p = 0.34). During six years of follow-up, median pSWE and TE values did not differ significantly over time (TE: p = 0.27; pSWE: p = 0.05).
Conclusion: Our data indicate that pSWE could be useful for non-invasive fibrosis assessment and follow-up in patients with HBeAg-negative chronic HBV infection.
Radiographic and safety details of vertebral body stenting : results from a multicenter chart review
(2013)
Background: Up to one third of BKP treated cases shows no appreciable height restoration due to loss of both restored height and kyphotic realignment after balloon deflation. This shortcoming has called for an improved method that maintains the height and realignment reached by the fully inflated balloon until stabilization of the vertebral body by PMMA-based cementation. Restoration of the physiological vertebral body height for pain relief and for preventing further fractures of adjacent and distant vertebral bodies must be the main aim for such a method. A new vertebral body stenting system (VBS) stabilizes the vertebral body after balloon deflation until cementation. The radiographic and safety results of the first 100 cases where VBS was applied are presented.
Methods: During the planning phase of an ongoing international multicenter RCT, radiographic, procedural and followup details were retrospectively transcribed from charts and xrays for developing and testing the case report forms. Radiographs were centrally assessed at the institution of the first/senior author.
Results: 100 patients (62 with osteoporosis) with a total of 103 fractured vertebral bodies were treated with the VBS system. 49 were females with a mean age of 73.2 years; males were 66.7 years old. The mean preoperative anterior-middle-posterior heights were 20.3-17.6-28.0 mm, respectively. The mean local kyphotic angle was 13.1°. The mean preoperative Beck Index (anterior edge height/posterior edge height) was 0.73, the mean alternative Beck Index (middle height/posterior edge height) was 0.63. The mean postoperative heights were restored to 24.5-24.6-30.4 mm, respectively. The mean local kyphotic angle was reduced to 8.9°. The mean postoperative Beck Index was 0.81, the mean alternative one was 0.82. The overall extrusion rate was 29.1%, the symptomatic one was 1%. In the osteoporosis subgroup there were 23.8% extrusions. Within the three months followup interval there were 9% of adjacent and 4% of remote new fractures, all in the osteoporotic group.
Conclusions: VBS showed its strengths especially in realignment of crush and biconcave fractures. Given that fracture mobility is present, the realignment potential is sound and increases with the severity of preoperative vertebral body deformation.