Background: Anemia is the most important complication during major surgery and transfusion of red blood cells is the mainstay to compensate for life threating blood loss. Therefore, accurate measurement of hemoglobin (Hb) concentration should be provided in real-time. Blood Gas Analysis (BGA) provides rapid point-of-care assessment using smaller sampling tubes compared to central laboratory (CL) services. Objective: This study aimed to investigate the accuracy of BGA hemoglobin testing as compared to CL services. Methods: Data of the ongoing LIBERAL-Trial (Liberal transfusion strategy to prevent mortality and anemia-associated ischemic events in elderly non-cardiac surgical patients, LIBERAL) was used to assess the bias for Hb level measured by BGA devices (ABL800 Flex analyzer®, GEM series® and RapidPoint 500®) and CL as the reference method. For that, we analyzed pairs of Hb level measured by CL and BGA within two hours. Furthermore, the impact of various confounding factors including age, gender, BMI, smoker status, transfusion of RBC, intraoperative hemodilution, and co-medication was elucidated. In order to ensure adequate statistical analysis, only data of participating centers providing more than 200 Hb pairs were used. Results: In total, three centers including 963 patients with 1,814 pairs of Hb measurements were analyzed. Mean bias was comparable between ABL800 Flex analyzer® and GEM series®: - 0.38 ± 0.15 g/dl whereas RapidPoint 500® showed a smaller bias (-0.09 g/dl) but greater median absolute deviation (± 0.45 g/dl). In order to avoid interference with different standard deviations caused by the different analytic devices, we focused on two centers using the same BGA technique (309 patients and 1,570 Hb pairs). A Bland-Altman analysis and LOWESS curve showed that bias decreased with smaller Hb values in absolute numbers but increased relatively. The smoker status showed the greatest reduction in bias (0.1 g/dl, p<0.001) whereas BMI (0.07 g/dl, p = 0.0178), RBC transfusion (0.06 g/dl, p<0.001), statins (0.04 g/dl, p<0.05) and beta blocker (0.03 g/dl, p = 0.02) showed a slight effect on bias. Intraoperative substitution of volume and other co-medications did not influence the bias significantly. Conclusion: Many interventions like substitution of fluids, coagulating factors or RBC units rely on the accuracy of laboratory measurement devices. Although BGA Hb testing showed a consistently stable difference to CL, our data confirm that BGA devices are associated with different bias. Therefore, we suggest that hospitals assess their individual bias before implementing BGA as valid and stable supplement to CL. However, based on the finding that bias decreased with smaller Hb values, which in turn are used for transfusion decision, we expect no unnecessary or delayed RBC transfusion, and no major impact on the LIBERAL trial performance.
A list of authors and their affiliations appears at the end of the paper New-particle formation is a major contributor to urban smog, but how it occurs in cities is often puzzling. If the growth rates of urban particles are similar to those found in cleaner environments (1–10 nanometres per hour), then existing understanding suggests that new urban particles should be rapidly scavenged by the high concentration of pre-existing particles. Here we show, through experiments performed under atmospheric conditions in the CLOUD chamber at CERN, that below about +5 degrees Celsius, nitric acid and ammonia vapours can condense onto freshly nucleated particles as small as a few nanometres in diameter. Moreover, when it is cold enough (below −15 degrees Celsius), nitric acid and ammonia can nucleate directly through an acid–base stabilization mechanism to form ammonium nitrate particles. Given that these vapours are often one thousand times more abundant than sulfuric acid, the resulting particle growth rates can be extremely high, reaching well above 100 nanometres per hour. However, these high growth rates require the gas-particle ammonium nitrate system to be out of equilibrium in order to sustain gas-phase supersaturations. In view of the strong temperature dependence that we measure for the gas-phase supersaturations, we expect such transient conditions to occur in inhomogeneous urban settings, especially in wintertime, driven by vertical mixing and by strong local sources such as traffic. Even though rapid growth from nitric acid and ammonia condensation may last for only a few minutes, it is nonetheless fast enough to shepherd freshly nucleated particles through the smallest size range where they are most vulnerable to scavenging loss, thus greatly increasing their survival probability. We also expect nitric acid and ammonia nucleation and rapid growth to be important in the relatively clean and cold upper free troposphere, where ammonia can be convected from the continental boundary layer and nitric acid is abundant from electrical storms.
Contribution of sulfuric acid and oxidized organic compounds to particle formation and growth
(2012)
Lack of knowledge about the mechanisms underlying new particle formation and their subsequent growth is one of the main causes for the large uncertainty in estimating the radiative forcing of atmospheric aerosols in global models. We performed chamber experiments designed to study the contributions of sulfuric acid and organic vapors to formation and to the early growth of nucleated particles, respectively. Distinct experiments in the presence of two different organic precursors (1,3,5-trimethylbenzene and α-pinene) showed the ability of these compounds to reproduce the formation rates observed in the low troposphere. These results were obtained measuring the sulfuric acid concentrations with two Chemical Ionization Mass Spectrometers confirming the results of a previous study which modeled the sulfuric acid concentrations in presence of 1,3,5-trimethylbenzene.
New analysis methods were applied to the data collected with a Condensation Particle Counter battery and a Scanning Mobility Particle Sizer, allowing the assessment of the size resolved growth rates of freshly nucleated particles. The effect of organic vapors on particle growth was investigated by means of the growth rate enhancement factor (Γ), defined as the ratio between the measured growth rate in the presence of α-pinene and the kinetically limited growth rate of the sulfuric acid and water system. The observed Γ values indicate that the growth is dominated by organic compounds already at particle diameters of 2 nm. Both the absolute growth rates and Γ showed a strong dependence on particle size supporting the nano-Köhler theory. Moreover, the separation of the contributions from sulfuric acid and organic compounds to particles growth reveals that the organic contribution seems to be enhanced by the sulfuric acid concentration. The size resolved growth analysis finally indicates that both condensation of oxidized organic compounds and reactive uptake contribute to particle growth.
Contribution of sulfuric acid and oxidized organic compounds to particle formation and growth
(2012)
Lack of knowledge about the mechanisms underlying new particle formation and their subsequent growth is one of the main causes for the large uncertainty in estimating the radiative forcing of atmospheric aerosols in global models. We performed chamber experiments designed to study the contributions of sulfuric acid and organic vapors to the formation and early growth of nucleated particles. Distinct experiments in the presence of two different organic precursors (1,3,5-trimethylbenzene and α-pinene) showed the ability of these compounds to reproduce the formation rates observed in the low troposphere. These results were obtained measuring the sulfuric acid concentrations with two chemical ionization mass spectrometers confirming the results of a previous study which modeled the sulfuric acid concentrations in presence of 1,3,5-trimethylbenzene.
New analysis methods were applied to the data collected with a condensation particle counter battery and a scanning mobility particle sizer, allowing the assessment of the size resolved growth rates of freshly nucleated particles. The effect of organic vapors on particle growth was investigated by means of the growth rate enhancement factor (Γ), defined as the ratio between the measured growth rate in the presence of α-pinene and the kinetically limited growth rate of the sulfuric acid and water system. The observed Γ values indicate that the growth is already dominated by organic compounds at particle diameters of 2 nm. Both the absolute growth rates and Γ showed a strong dependence on particle size, supporting the nano-Köhler theory. Moreover, the separation of the contributions from sulfuric acid and organic compounds to particle growth reveals that the organic contribution seems to be enhanced by the sulfuric acid concentration. Finally, the size resolved growth analysis indicates that both condensation of oxidized organic compounds and reactive uptake contribute to particle growth.
A recent CLOUD (Cosmics Leaving OUtdoor Droplets) chamber study showed that sulfuric acid and dimethylamine produce new aerosols very efficiently and yield particle formation rates that are compatible with boundary layer observations. These previously published new particle formation (NPF) rates are reanalyzed in the present study with an advanced method. The results show that the NPF rates at 1.7 nm are more than a factor of 10 faster than previously published due to earlier approximations in correcting particle measurements made at a larger detection threshold. The revised NPF rates agree almost perfectly with calculated rates from a kinetic aerosol model at different sizes (1.7 and 4.3 nm mobility diameter). In addition, modeled and measured size distributions show good agreement over a wide range of sizes (up to ca. 30 nm). Furthermore, the aerosol model is modified such that evaporation rates for some clusters can be taken into account; these evaporation rates were previously published from a flow tube study. Using this model, the findings from the present study and the flow tube experiment can be brought into good agreement for the high base-to-acid ratios (∼ 100) relevant for this study. This confirms that nucleation proceeds at rates that are compatible with collision-controlled (a.k.a. kinetically controlled) NPF for the conditions during the CLOUD7 experiment (278 K, 38 % relative humidity, sulfuric acid concentration between 1 × 106 and 3 × 107 cm−3, and dimethylamine mixing ratio of ∼ 40 pptv, i.e., 1 × 109 cm−3).
A recent CLOUD (Cosmics Leaving OUtdoor Droplets) chamber study showed that sulfuric acid and dimethylamine produce new aerosols very efficiently, and yield particle formation rates that are compatible with boundary layer observations. These previously published new particle formation (NPF) rates are re-analyzed in the present study with an advanced method. The results show that the NPF rates at 1.7 nm are more than a factor of 10 faster than previously published due to earlier approximations in correcting particle measurements made at larger detection threshold. The revised NPF rates agree almost perfectly with calculated rates from a kinetic aerosol model at different sizes (1.7 nm and 4.3 nm mobility diameter). In addition, modeled and measured size distributions show good agreement over a wide range (up to ca. 30 nm). Furthermore, the aerosol model is modified such that evaporation rates for some clusters can be taken into account; these evaporation rates were previously published from a flow tube study. Using this model, the findings from the present study and the flow tube experiment can be brought into good agreement. This confirms that nucleation proceeds at rates that are compatible with collision-controlled (a.k.a. kinetically-controlled) new particle formation for the conditions during the CLOUD7 experiment (278 K, 38% RH, sulfuric acid concentration between 1×106 and 3×107 cm-3 and dimethylamine mixing ratio of ~40 pptv). Finally, the simulation of atmospheric new particle formation reveals that even tiny mixing ratios of dimethylamine (0.1 pptv) yield NPF rates that could explain significant boundary layer particle formation. This highlights the need for improved speciation and quantification techniques for atmospheric gas-phase amine measurements.
Binary nucleation of sulphuric acid-water particles is expected to be an important process in the free troposphere at low temperatures. SAWNUC (Sulphuric Acid Water Nucleation) is a model of binary nucleation that is based on laboratory measurements of the binding energies of sulphuric acid and water in charged and neutral clusters. Predictions of SAWNUC are compared for the first time comprehensively with experimental binary nucleation data from the CLOUD chamber at European Organization for Nuclear Research. The experimental measurements span a temperature range of 208–292 K, sulphuric acid concentrations from 1·106 to 1·109 cm−3, and distinguish between ion-induced and neutral nucleation. Good agreement, within a factor of 5, is found between the experimental and modeled formation rates for ion-induced nucleation at 278 K and below and for neutral nucleation at 208 and 223 K. Differences at warm temperatures are attributed to ammonia contamination which was indicated by the presence of ammonia-sulphuric acid clusters, detected by an Atmospheric Pressure Interface Time of Flight (APi-TOF) mass spectrometer. APi-TOF measurements of the sulphuric acid ion cluster distributions (math formula with i = 0, 1, ..., 10) show qualitative agreement with the SAWNUC ion cluster distributions. Remaining differences between the measured and modeled distributions are most likely due to fragmentation in the APi-TOF. The CLOUD results are in good agreement with previously measured cluster binding energies and show the SAWNUC model to be a good representation of ion-induced and neutral binary nucleation of sulphuric acid-water clusters in the middle and upper troposphere.
Background: HCV GT4 accounts for up to 20% of HCV infections worldwide. Simeprevir, given for 12 weeks as part of a 24- or 48-week combination regimen with PR is approved for the treatment of chronic HCV GT4 infection. Primary study objectives were assessment of efficacy and safety of simeprevir plus PR in treatment-naïve patients with HCV GT4 treated for 12 weeks. Primary efficacy outcome was sustained virologic response 12 weeks post-treatment (SVR12). Additional objectives included investigation of potential associations of rapid virologic response and baseline factors with SVR12.
Methods: This multicentre, open-label, single-arm study (NCT01846832) evaluated efficacy and safety of simeprevir plus PR in 67 patients with HCV GT4 infection. Patients were treatment-naïve, aged 18–70 years with METAVIR F0–F2 fibrosis. Patients with early virologic response (HCV RNA <25 IU/mL [detectable/undetectable in IL28B CC patients or undetectable in IL28B CT/TT patients] at Week 2 and undetectable at Weeks 4 and 8) were eligible to stop all treatment at the end of Week 12, otherwise PR therapy was continued to Week 24.
Results: Of 67 patients treated, 34 (51%) qualified for 12-week treatment including all but one patient with IL28B CC genotype (14/15). All patients in the 12-week group had undetectable HCV RNA at end of treatment, and 97% (33/34) achieved SVR12. No new safety signals with simeprevir plus PR were identified. The proportion of patients experiencing Grade 3–4 adverse events was lower in the 12-week group than in the 24-week group.
Conclusions: Our findings on simeprevir plus PR therapy shortened to 12 weeks in patients with HCV GT4 infection with favourable baseline characteristics and displaying early on-treatment virologic response are encouraging. No new safety signals were associated with simeprevir plus PR in this study.
Background: Shortening duration of peginterferon-based HCV treatment reduces associated burden for patients. Primary objectives of this study were to assess the efficacy against the minimally acceptable response rate 12 weeks post-treatment (SVR12) and safety of simeprevir plus PR in treatment-naïve HCV GT1 patients treated for 12 weeks. Additional objectives included the investigation of potential associations of rapid viral response and baseline factors with SVR12.
Methods: In this Phase III, open-label study in treatment-naïve HCV GT1 patients with F0–F2 fibrosis, patients with HCV-RNA <25 IU/mL (detectable/undetectable) at Week 2, and undetectable HCV-RNA at Weeks 4 and 8, stopped all treatment at Week 12. All other patients continued PR for a further 12 weeks. Baseline factors significantly associated with SVR12 were identified through logistic regression.
Results: Of 163 patients who participated in the study, 123 (75%) qualified for 12-week treatment; of these, 81 (66%) achieved SVR12. Baseline factors positively associated with SVR12 rates in patients receiving the 12-week regimen were: IL28B CC genotype: (94% SVR12); HCV RNA ≤800,000 IU/mL (82%); F0–F1 fibrosis (74%). Among all 163 patients, 94% experienced ≥1 adverse event (AE), 4% a serious AE, and 2.5% discontinued due to an AE. Reduced impairment in patient-reported outcomes was observed in the 12-week vs >12-week regimen.
Conclusions: Overall SVR12 rate (66%) was below the target of 80%, indicating that shortening of treatment with simeprevir plus PR to 12 weeks based on very early response is not effective. However, baseline factors associated with higher SVR12 rates were identified. Therefore, while Week 2 response alone is insufficient to predict efficacy, GT1 patients with favourable baseline factors may benefit from a shortened simeprevir plus PR regimen.
Trial Registration: ClinicalTrials.gov NCT01846832
The radiative capture cross section of 238U is very important for the developing of new reactor technologies and the safety of existing ones. Here the preliminary results of the 238U(n,γ) cross section measurement performed at n_TOF with C6D6 scintillation detectors are presented, paying particular attention to data reduction and background subtraction.