Refine
Year of publication
Document Type
- Preprint (767)
- Article (626)
- Conference Proceeding (4)
- Doctoral Thesis (1)
- Working Paper (1)
Language
- English (1392)
- German (6)
- Multiple languages (1)
Has Fulltext
- yes (1399)
Is part of the Bibliography
- no (1399)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron Scattering (11)
- Hadron-Hadron scattering (experiments) (11)
- BESIII (9)
- LHC (9)
- Branching fraction (7)
- e +-e − Experiments (7)
- Heavy-ion collision (6)
- HIV (5)
- Particle and Resonance Production (5)
Institute
- Physik (1266)
- Frankfurt Institute for Advanced Studies (FIAS) (956)
- Informatik (921)
- Medizin (103)
- ELEMENTS (18)
- Geowissenschaften (10)
- Biochemie und Chemie (5)
- Exzellenzcluster Herz-Lungen-System (3)
- Informatik und Mathematik (3)
- Biochemie, Chemie und Pharmazie (2)
Introduction: Prophylaxis with factor VIII (FVIII) concentrates in children with haemophilia A (HA) is current standard of care. The benefit of prophylactic treatment for adult HA patients is not commonly accepted.
Aim: To investigate the benefit of prophylaxis over on‐demand treatment in adult and elderly patients with severe or non‐severe HA in a real‐life setting.
Methods: Data from 163 patients comprising 1202 patient‐years were evaluated for 7.5 (±5.3) years. The effects on the annual bleeding rate (ABR, including spontaneous and traumatic bleeds) of treatment with a plasma‐derived FVIII concentrate, the patient's age and disease severity were investigated. The effect of changing the treatment from on demand to continuous prophylaxis on the patients’ ABRs was further analysed.
Results: Prophylaxis had the greatest effect on the ABRs of patients of any age with severe or non‐severe HA. The difference in ABR of all patients treated on demand (median 31.4; interquartile range (IQR) 27.6; N = 83) compared with those treated prophylactically (median 1.3; IQR 3.6; N = 122) was statistically significant (P < .05), even for patients with non‐severe HA (median 8.4; IQR 15.5; N = 11) vs median 1.5; IQR 4.2 (N = 17), P < .05). Patients, aged up to 88 years, switching from on demand to continuous prophylaxis showed the lowest median ABR (1.1; N = 51) after their regimen change.
Conclusion: Any (even low‐frequency) prophylaxis results in lower ABR than on‐demand treatment. Patients switching to prophylaxis benefitted the most, irrespective of age or HA severity. Prophylactic treatment—even tertiary—is the regimen of choice for patients of any age, including elderly patients, with severe or non‐severe HA.
Improved integration of single cell transcriptome data demonstrated on heart failure in mice and men
(2023)
Biomedical research frequently uses murine models to study disease mechanisms. However, the translation of these findings to human disease remains a significant challenge. In order to improve the comparability of mouse and human data, we present a cross-species integration pipeline for single-cell transcriptomic assays.
The pipeline merges expression matrices and assigns clear orthologous relationships. Starting from Ensembl ortholog assignments, we allocated 82% of mouse genes to unique orthologs by using additional publicly available resources such as Uniprot, and NCBI databases. For genes with multiple matches, we employed the Needleman-Wunsch global alignment based on either amino acid or nucleotide sequence to identify the ortholog with the highest degree of similarity.
The workflow was tested for its functionality and efficiency by integrating scRNA-seq datasets from heart failure patients with the corresponding mouse model. We were able to assign unique human orthologs to up to 80% of the mouse genes, utilizing the known 17,492 orthologous pairs. Curiously, the integration process enabled the identification of both common and unique regulatory pathways between species in heart failure.
In conclusion, our pipeline streamlines the integration process, enhances gene nomenclature alignment and simplifies the translation of mouse models to human disease. We have made the OrthoIntegrate R-package accessible on GitHub (https://github.com/MarianoRuzJurado/OrthoIntegrate), which includes the assignment of ortholog definitions for human and mouse, as well as the pipeline for integrating single cells.
Objectives: To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. Methods: L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19–103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. Results: A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091–0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867–0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. Conclusions: Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures.
Key Points: Dual-energy CT–derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm 3 vs 80 mg/cm 3 ).
System size dependence of multiplicity fluctuations of charged particles produced in nuclear collisions at 158 A GeV was studied in the NA49 CERN experiment. Results indicate a non-monotonic dependence of the scaled variance of the multiplicity distribution with a maximum for semi-peripheral Pb+Pb interactions with number of projectile participants of about 35. This effect is not observed in a string-hadronic model of nuclear collision HIJING.
The study of neutron-induced reactions is of high relevance in a wide variety of fields, ranging from stellar nucleosynthesis and fundamental nuclear physics to applications of nuclear technology. In nuclear energy, high accuracy neutron data are needed for the development of Generation IV fast reactors and accelerator driven systems, these last aimed specifically at nuclear waste incineration, as well as for research on innovative fuel cycles. In this context, a high luminosity Neutron Time Of Flight facility, n_TOF, is operating at CERN since more than a decade, with the aim of providing new, high accuracy and high resolution neutron cross-sections. Thanks to the features of the neutron beam, a rich experimental program relevant to nuclear technology has been carried out so far. The program will be further expanded in the near future, thanks in particular to a new high-flux experimental area, now under construction.
High precision measurement of the radiative capture cross section of 238U at the n_TOF CERN facility
(2017)
The importance of improving the accuracy on the capture cross-section of 238U has been addressed by the Nuclear Energy Agency, since its uncertainty significantly affects the uncertainties of key design parameters for both fast and thermal nuclear reactors. Within the 7th framework programme ANDES of the European Commission three different measurements have been carried out with the aim of providing the 238U(n,γ) cross-section with an accuracy which varies from 1 to 5%, depending on the energy range. Hereby the final results of the measurement performed at the n_TOF CERN facility in a wide energy range from 1 eV to 700 keV will be presented.
Neutron-induced fission cross sections of 238U and 235U are used as standards in the fast neutron region up to 200 MeV. A high accuracy of the standards is relevant to experimentally determine other neutron reaction cross sections. Therefore, the detection effciency should be corrected by using the angular distribution of the fission fragments (FFAD), which are barely known above 20 MeV. In addition, the angular distribution of the fragments produced in the fission of highly excited and deformed nuclei is an important observable to investigate the nuclear fission process.
In order to measure the FFAD of neutron-induced reactions, a fission detection setup based on parallel-plate avalanche counters (PPACs) has been developed and successfully used at the CERN-n_TOF facility. In this work, we present the preliminary results on the analysis of new 235U(n,f) and 238U(n,f) data in the extended energy range up to 200 MeV compared to the existing experimental data.
The n_TOF facility operates at CERN with the aim of addressing the request of high accuracy nuclear data for advanced nuclear energy systems as well as for nuclear astrophysics. Thanks to the features of the neutron beam, important results have been obtained on neutron induced fission and capture cross sections of U, Pu and minor actinides. Recently the construction of another beam line has started; the new line will be complementary to the first one, allowing to further extend the experimental program foreseen for next measurement campaigns.
The aim of this work is to provide a precise and accurate measurement of the 238U(n,γ) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behavior of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross section of 238U should be further reduced to 1–3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were proposed and carried out within the 7th Framework Project ANDES of the European Commission. The results of one of these 238U(n,γ) measurements performed at the n_TOF CERN facility are presented in this work. The γ-ray cascade following the radiative neutron capture has been detected exploiting a setup of two C6D6 liquid scintillators. Resonance parameters obtained from this work are on average in excellent agreement with the ones reported in evaluated libraries. In the unresolved resonance region, this work yields a cross section in agreement with evaluated libraries up to 80 keV, while for higher energies our results are significantly higher.
New results are presented of the 234U neutron-induced fission cross section, obtained with high accuracy in the resonance region by means of two methods using the 235U(n,f) as reference. The recent evaluation of the 235U(n,f) obtained with SAMMY by L. C. Leal et al. (these Proceedings), based on previous n_TOF data [1], has been used to calculate the 234U(n,f) cross section through the 234U/235U ratio, being here compared with the results obtained by using the n_TOF neutron flux.