Refine
Document Type
- Article (4)
Language
- English (4)
Has Fulltext
- yes (4)
Is part of the Bibliography
- no (4)
Keywords
- Beginners (1)
- CMR (1)
- Cine (1)
- Function (1)
- Teaching (1)
- cardiac magnetic resonance (1)
- myocardial fibrosis (1)
- scar (1)
Institute
- Medizin (3)
- Biowissenschaften (1)
FLRTs are broadly expressed proteins with the unique property of acting as homophilic cell adhesion molecules and as heterophilic repulsive ligands of Unc5/Netrin receptors. How these functions direct cell behavior and the molecular mechanisms involved remain largely unclear. Here we use X-ray crystallography to reveal the distinct structural bases for FLRT-mediated cell adhesion and repulsion in neurons. We apply this knowledge to elucidate FLRT functions during cortical development. We show that FLRTs regulate both the radial migration of pyramidal neurons, as well as their tangential spread. Mechanistically, radial migration is controlled by repulsive FLRT2-Unc5D interactions, while spatial organization in the tangential axis involves adhesive FLRT-FLRT interactions. Further, we show that the fundamental mechanisms of FLRT adhesion and repulsion are conserved between neurons and vascular endothelial cells. Our results reveal FLRTs as powerful guidance factors with structurally encoded repulsive and adhesive surfaces.
Myocardial fibrosis and inflammation by CMR predict cardiovascular outcome in people living with HIV
(2021)
Objectives_: The goal of this study was to examine prognostic relationships between cardiac imaging measures and cardiovascular outcome in people living with human immunodeficiency virus (HIV) (PLWH) on highly active antiretroviral therapy (HAART).
Background: PLWH have a higher prevalence of cardiovascular disease and heart failure (HF) compared with the noninfected population. The pathophysiological drivers of myocardial dysfunction and worse cardiovascular outcome in HIV remain poorly understood.
Methods: This prospective observational longitudinal study included consecutive PLWH on long-term HAART undergoing cardiac magnetic resonance (CMR) examination for assessment of myocardial volumes and function, T1 and T2 mapping, perfusion, and scar. Time-to-event analysis was performed from the index CMR examination to the first single event per patient. The primary endpoint was an adjudicated adverse cardiovascular event (cardiovascular mortality, nonfatal acute coronary syndrome, an appropriate device discharge, or a documented HF hospitalization).
Results: A total of 156 participants (62% male; age [median, interquartile range]: 50 years [42 to 57 years]) were included. During a median follow-up of 13 months (9 to 19 months), 24 events were observed (4 HF deaths, 1 sudden cardiac death, 2 nonfatal acute myocardial infarction, 1 appropriate device discharge, and 16 HF hospitalizations). Patients with events had higher native T1 (median [interquartile range]: 1,149 ms [1,115 to 1,163 ms] vs. 1,110 ms [1,075 to 1,138 ms]); native T2 (40 ms [38 to 41 ms] vs. 37 ms [36 to 39 ms]); left ventricular (LV) mass index (65 g/m2 [49 to 77 g/m2] vs. 57 g/m2 [49 to 64 g/m2]), and N-terminal pro–B-type natriuretic peptide (109 pg/l [25 to 337 pg/l] vs. 48 pg/l [23 to 82 pg/l]) (all p < 0.05). In multivariable analyses, native T1 was independently predictive of adverse events (chi-square test, 15.9; p < 0.001; native T1 [10 ms] hazard ratio [95% confidence interval]: 1.20 [1.08 to 1.33]; p = 0.001), followed by a model that also included LV mass (chi-square test, 17.1; p < 0.001). Traditional cardiovascular risk scores were not predictive of the adverse events.
Conclusions: Our findings reveal important prognostic associations of diffuse myocardial fibrosis and LV remodeling in PLWH. These results may support development of personalized approaches to screening and early intervention to reduce the burden of HF in PLWH (International T1 Multicenter Outcome Study; NCT03749343).
Background: High reproducibility and low intra- and interobserver variability are important strengths of cardiac magnetic resonance (CMR). In clinical practice a significant learning curve may however be observed. Basic CMR courses offer an average of 1.4 h dedicated to lecturing and demonstrating left ventricular (LV) function analysis. The purpose of this study was to evaluate the effect of initial teaching on complete and intermediate beginners’ quantitative measurements of LV volumes and function by CMR.
Methods: Standard clinical cine CMR sequences were acquired in 15 patients. Five observers (two complete beginners, one intermediate, two experienced) measured LV volumes. Before initial evaluation beginners read the SCMR guidelines on CMR analysis. After initial evaluation, beginners participated in a two-hour teaching session including cases and hands-on training, representative for most basic CMR courses, after which it is uncertain to what extent different centres provide continued teaching and feedback in-house. Dice Similarity Coefficient (DSC) assessed delineations. Agreement, accuracy, precision, repeatability and reliability were assessed by Bland-Altman, coefficient of variation, and intraclass correlation coefficient methods.
Results: Endocardial DSC improved after teaching (+0.14 ± 0.17;p < 0.001) for complete beginners. Low intraobserver variability was found before and after teaching, however with wide limits of agreement. Beginners underestimated volumes by up to 44 ml (EDV), 27 ml (ESV) and overestimated LVM by up to 53 g before teaching, improving to an underestimation of up to 9 ml (EDV), 7 ml (ESV) and an overestimation of up to 30 g (LVM) after teaching. For the intermediate beginner, however, accuracy was quite high already before teaching.
Conclusions: Initial teaching to complete beginners increases accuracy for assessment of LV volumes, however with high bias and low precision even after standardised teaching as offered in most basic CMR courses. Even though the intermediate beginner showed quite high accuracy already before teaching, precision did generally not improve after standardised teaching. To maintain CMR as a technique known for high accuracy and reproducibility and low intra- and inter-observer variability for quantitative measurements, internationally standardised training should be encouraged including high-quality feedback mechanisms. Objective measurements of training methods, training duration and, above all, quality of assessments are required.