Refine
Year of publication
Language
- English (56)
Has Fulltext
- yes (56)
Is part of the Bibliography
- no (56)
Keywords
- 140Ce (1)
- Electromagnetic transitions (1)
- MACS (1)
- Models & methods for nuclear reactions (1)
- Neutron physics (1)
- Nuclear reactions (1)
- Radiative capture (1)
- Resonance reactions (1)
- capture (1)
- cerium (1)
Institute
- Physik (55)
- Biochemie, Chemie und Pharmazie (1)
233U is of key importance among the fissile nuclei in the Th-U fuel cycle. A particularity of 233U is its small neutron capture cross-section, which is on average about one order of magnitude lower than the fission cross-section. The accuracy in the measurement of the 233U capture cross-section depends crucially on an efficient capture-fission discrimination, thus a combined set-up of fission and γ-detectors is needed. A measurement of the 233U capture cross-section and capture-to-fission ratio was performed at the CERN n_TOF facility. The Total Absorption Calorimeter (TAC) of n_TOF was employed as γ-detector coupled with a novel compact ionization chamber as fission detector. A brief description of the experimental set-up will be given, and essential parts of the analysis procedure as well as the preliminary response of the set-up to capture are presented and discussed.
Neutron-induced fission cross sections of isotopes involved in the nuclear fuel cycle are vital for the design and safe operation of advanced nuclear systems. Such experimental data can also provide additional constraints for the adjustment of nuclear model parameters used in the evaluation process, resulting in the further development of fission models. In the present work, the 237Np(n,f) cross section was studied at the EAR2 vertical beam-line at CERN's n_TOF facility, over a wide range of neutron energies, from meV to MeV, using the time-of-flight technique and a set-up based on Micromegas detectors, in an attempt to provide accurate experimental data. Preliminary results in the 200 keV – 14 MeV neutron energy range as well as the experimental procedure, including a description of the facility and the data handling and analysis, will be presented.
We have measured the γ-rays following neutron capture on 240Pu and 244 Cm at the n_TOF facility at CERN with the Total Absorption Calorimeter (TAC) and with C6D6 organic scintillators. The TAC is made of 40 BaF2 crystals operating in coincidence and covering almost the entire solid angle. This allows to obtain information concerning the energy spectra and the multiplicity of the measured capture γ-ray cascades. Additional information is also obtained from the C6D6 detectors. We have analyzed the measured data in order to draw conclusions about the Photon Strength Functions (PSFs) of 241Pu and 245Cm below their neutron separation energies. The analysis has been performed by fitting the PSFs to the experimental results, using the differential evolution method, in order to find neutron capture cascades capable of reproducing at the same time a great variety of deposited energy spectra.
The design and operation of innovative nuclear systems requires a better knowledge of the capture and fission cross sections of the Pu isotopes. For the case of capture on 242Pu, a reduction of the uncertainty in the fast region down to 8-12% is required. Moreover, aiming at improving the evaluation of the fast energy range in terms of average parameters, the OECD NEA High Priority Request List (HPRL) requests high-resolution capture measurements with improved accuracy below 2 keV. The current uncertainties also affect the thermal point, where previous experiments deviate from each other by 20%. A fruitful collaboration betwen JGU Mainz and HZ Dresden-Rossendorf within the EC CHANDA project resulted in a 242Pu sample consisting of a stack of seven fission-like targets making a total of 95(4) mg of 242Pu electrodeposited on thin (11.5 μm) aluminum backings. This contribution presents the results of a set of measurements of the 242Pu(n, γ) cross section from thermal to 500 keV combining different neutron beams and techniques. The thermal point was determined at the Budapest Research Reactor by means of Neutron Activation Analysis and Prompt Gamma Analysis, and the resolved (1 eV - 4 keV) and unresolved (1 - 500 keV) resonance regions were measured using a set of four Total Energy detectors at the CERN n_TOF-EAR1.
Destruction of the cosmic γ-ray emitter 26Al in massive stars: study of the key 26Al(n,p) reaction
(2021)
The 26Al(n,p)26Mg reaction is the key reaction impacting on the abundances of the cosmic γ-ray emitter 26Al produced in massive stars and impacts on the potential pollution of the early solar system with 26Al by asymptotic giant branch stars. We performed a measurement of the 26Al(n,p)26Mg cross section at the high-flux beam line EAR-2 at the n_TOF facility (CERN). We report resonance strengths for eleven resonances, nine being measured for the first time, while there is only one previous measurement for the other two. Our resonance strengths are significantly lower than the only previous values available. Our cross-section data range to 150 keV neutron energy, which is sufficient for a reliable determination of astrophysical reactivities up to 0.5 GK stellar temperature.
The Cosmological Lithium Problem refers to the large discrepancy between the abundance of primordial 7Li predicted by the standard theory of Big Bang Nucleosynthesis and the value inferred from the so-called “Spite plateau” in halo stars. A possible explanation for this longstanding puzzle in Nuclear Astrophysics is related to the incorrect estimation of the destruction rate of 7Be, which is responsible for the production of 95% of primordial Lithium. While charged-particle induced reactions have mostly been ruled out, data on the 7Be(n,α) and 7Be(n,p) reactions are scarce or completely missing, so that a large uncertainty still affects the abundance of 7Li predicted by the standard theory of Big Bang Nucleosynthesis. Both reactions have been measured at the n_TOF facility at CERN, providing for the first time data in a wide neutron energy range.
The 14N(n,p)14C reaction is of interest in neutron capture therapy, where nitrogen-related dose is the main component due to low-energy neutrons, and in astrophysics, where 14N acts as a neutron poison in the s-process. Several discrepancies remain between the existing data obtained in partial energy ranges: thermal energy, keV region and resonance region. Purpose: Measuring the 14N(n,p)14C cross section from thermal to the resonance region in a single measurement for the first time, including characterization of the first resonances, and providing calculations of Maxwellian averaged cross sections (MACS). Method: Time-of-flight technique. Experimental Area 2 (EAR-2) of the neutron time-of-flight (n_TOF) facility at CERN. 10B(n,α)7Li and 235U(n,f) reactions as references. Two detection systems running simultaneously, one on-beam and another off-beam. Description of the resonances with the R-matrix code sammy. Results: The cross section has been measured from sub-thermal energy to 800 keV resolving the two first resonances (at 492.7 and 644 keV). A thermal cross-section (1.809±0.045 b) lower than the two most recent measurements by slightly more than one standard deviation, but in line with the ENDF/B-VIII.0 and JEFF-3.3 evaluations has been obtained. A 1/v energy dependence of the cross section has been confirmed up to tens of keV neutron energy. The low energy tail of the first resonance at 492.7 keV is lower than suggested by evaluated values, while the overall resonance strength agrees with evaluations. Conclusions: Our measurement has allowed to determine the 14N(n,p) cross-section over a wide energy range for the first time. We have obtained cross-sections with high accuracy (2.5 %) from sub-thermal energy to 800 keV and used these data to calculate the MACS for kT = 5 to kT = 100 keV.
The 33S(n,α)30Si cross section measurement, using 10B(n,α) as reference, at the n_TOF Experimental Area 2 (EAR2) facility at CERN is presented. Data from 0.01 eV to 100 keV are provided and, for the first time, the cross section is measured in the range from 0.01 eV to 10 keV. These data may be used for a future evaluation of the cross section because present evaluations exhibit large discrepancies. The 33S(n,α)30Si reaction is of interest in medical physics because of its possible use as a cooperative target to boron in Neutron Capture Therapy (NCT).
The neutron capture cross section of some unstable nuclei is especially relevant for s-process nucleosynthesis studies. This magnitude is crucial to determine the local abundance pattern, which can yield valuable information of the s-process stellar environment. In this work we describe the neutron capture (n,γ) measurement on two of these nuclei of interest, 204Tl and 171Tm, from target production to the final measurement, performed successfully at the n_TOF facility at CERN in 2014 and 2015. Preliminary results on the ongoing experimental data analysis will also be shown. These results include the first ever experimental observation of capture resonances for these two nuclei.
The CERN n_TOF neutron beam facility is characterized by a very high instantaneous neutron flux, excellent TOF resolution at the 185 m long flight path (EAR-1), low intrinsic background and coverage of a wide range of neutron energies, from thermal to a few GeV. These characteristics provide a unique possibility to perform high-accuracy measurements of neutron-induced reaction cross-sections and angular distributions of interest for fundamental and applied Nuclear Physics. Since 2001, the n_TOF Collaboration has collected a wealth of high quality nuclear data relevant for nuclear astrophysics, nuclear reactor technology, nuclear medicine, etc. The overall efficiency of the experimental program and the range of possible measurements has been expanded with the construction of a second experimental area (EAR-2), located 20 m on the vertical of the n_TOF spallation target. This upgrade, which benefits from a neutron flux 30 times higher than in EAR-1, provides a substantial extension in measurement capabilities, opening the possibility to collect data on neutron cross-section of isotopes with short half-lives or available in very small amounts. This contribution will outline the main characteristics of the n_TOF facility, with special emphasis on the new experimental area. In particular, we will discuss the innovative features of the EAR-2 neutron beam that make possible to perform very challenging measurements on short-lived radioisotopes or sub-mg samples, out of reach up to now at other neutron facilities around the world. Finally, the future perspectives of the facility will be presented.