Refine
Year of publication
Document Type
- Article (22)
- Doctoral Thesis (1)
Has Fulltext
- yes (23)
Is part of the Bibliography
- no (23)
Keywords
Sarcomas are rare cancers with high heterogeneity in terms of type, location, and treatment. The health-related quality of life (HRQoL) of sarcoma patients has rarely been investigated and is the subject of this analysis. Adult sarcoma patients and survivors were assessed between September 2017 and February 2019 in 39 study centers in Germany using standardized, validated questionnaires (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30)). Associated factors were analyzed exploratively using multivariable linear regressions. Among 1113 patients, clinically important limitations and symptoms were most pronounced in emotional (63%, 95% CI 60–66%), physical (60%, 95% CI 57–62%), role functioning (51%, 95% CI 48–54%), and pain (56%, 95% CI 53–59%) and fatigue (51%, 95% CI 48–54%). HRQoL differed between tumor locations with lower extremities performing the worst and sarcoma types with bone sarcoma types being most affected. Additionally, female gender, higher age, lower socioeconomic status, recurrent disease, not being in retirement, comorbidities, and being in treatment were associated with lower HRQoL. Sarcoma patients are severely restricted in their HRQoL, especially in functioning scales. The heterogeneity of sarcomas with regard to type and location is reflected in HRQoL outcomes. During treatment and follow-up, close attention has to be paid to the reintegration of the patients into daily life as well as to their physical abilities and emotional distress.
Objective. We investigated the health-related quality of life (HRQoL) of patients with gastrointestinal stromal tumours (GIST). Methods: In the multicentre PROSa study, the HRQoL of adult GIST patients was assessed between 2017 and 2019 using the European Organisation for Research and Treatment of Cancer HRQoL questionnaire (EORTC QLQ-C30). We performed group comparisons and multivariate linear regressions. Results: Among 130 patients from 13 centres, the mean global HRQoL was 63.3 out of 100 points. Higher sores indicate better HRQoL. The highest restrictions were in emotional, social, role functioning, insomnia, fatigue, and pain. In multivariate linear regression, we found no significant differences between patients receiving tyrosine kinase inhibitor (TKI) treatment and those without TKI treatment as well as between patients treated with curative or with palliative intent. Patients who received multiple lines of TKI treatment had the most restrictions, notably in physical (unstandardized regression coefficient [B] = −15.7), role (B = −25.7), social (B = −18.4), and cognitive functioning (B = −19.7); fatigue (B = 15.93); general health (B = −14.23); and EORTC-sum score (B = −13.82) compared to all other patients. Conclusion: The highest HRQoL restrictions were in GIST patients receiving multiple lines of TKI therapy. Underlying causes need further investigation.
Background: Computed-tomography-guided interventions are attractive for tissue sampling of paediatric tumor lesions; however, it comes with exposure to ionizing radiation. The aim of this study was to analyse the radiation dose, accuracy and speed of CT-guided interventions in paediatric patient cohort.
Methods: We retrospectively reviewed CT-guided interventions over a 10 -year period in 65 children. The intervention site consisted of bones in 38, chest (lung) in 15 and abdomen (liver, lymph nodes) in 12 cases. Radiation dose and duration of the procedures were analysed. The statistical analysis was performed using dedicated statistical software (BiAS 8.3.6 software, Epsilon Verlag, North Hasted).
Results: All interventions were performed successfully. Mean target access path to lesion within the patients was 6.0 cm (min 3.5 cm, max 11.2 cm). Time duration to complete intervention was 25:15 min (min 17:03 min, max 43:00 min). The dose-length product (DLP) of intervention scan was 29.5 mGy · cm (min 6 mGy · cm, max 85 mGy · cm) with the lowest dose for biopsies in the region of the chest (p = 0.04).
Conclusions: With justified indications, CT-guided paediatric interventions are safe, effective and can be performed both, with short intervention times and low radiation exposure.
Background: To evaluate survival data and local tumor control after transarterial chemoembolization in two groups with different embolization protocols for the treatment of HCC patients.
Methods: Ninty-nine patients (mean age: 63.6 years), 78 male (78.8%) with HCC were repeatedly treated with chemoembolization in 4-week-intervals. Eighty-eight patients had BCLC-Stage-B and in 11 patients, chemoembolization was performed for bridging (BCLC-Stage-A). In total, 667 chemoembolization treatments were performed (mean 6.7 treatments/patient). The administered chemotherapeutic agent included mitomycin. For embolization, lipiodol only (n = 51;51.5%; mean age 63.8 years; 38 male), or lipiodol plus degradable starch microspheres (DSM) (n = 48; 48.5%; mean age 63.4 years; 40 male) were used. The local tumor response was assessed by MRI using Response Evaluation Criteria in Solid Tumors 1.1 (RECIST 1.1). Patient survival times were evaluated using Kaplan-Meier curves and log-rank tests.
Results: The local tumor control in the lipiodol-group was: PR (partial response) in 11 (21.6%), SD (stable disease) in 32 (62.7%) and PD (progressive disease) in 8 cases (15.7%). In the lipiodol-DSM-group, PR was seen in 14 (29.2%), SD in 22 (45.8%), and PD in 12 (25.0%) individuals (p = 0.211). The median survival of patients after chemoembolization with lipiodol was 25 months and in the lipiodol-DSM-group 28 months (p = 0.845).
Conclusion: Our data suggest a slight benefit of the use of lipiodol and DSM in comparison of using lipiodol only for chemoembolization of HCC in terms of local tumor control and survival data, this trend did not reach the level of significance.
The objective of this pilot clinical study was to assess the safety, technical feasibility, pharmacokinetic (PK) profile and tumour response of DC Bead™ with irinotecan (DEBIRI™) delivered by intra-arterial embolisation for the treatment of metastatic colorectal cancer. Eleven patients with unresectable liver metastases from CRC, tumour burden <30% of liver volume, adequate haematological, liver and renal function, performance status of <2 were included in this study. Patients received up to 4 sessions of TACE with DEBIRI at 3-week intervals. Feasibility of the procedure, safety and tumour response were assessed after each cycle. PK was measured after the first cycle. Patients were followed up to 24 weeks. Only mild to moderate adverse events were observed. DEBIRI is a technically feasibile procedure; no technical complications were observed. Average Cmax for irinotecan and SN-38 was 194 ng/ml and 16.7 ng/ml, respectively, with average t½ of 4.6 h and 12.4 h following administration of DEBIRI. Best overall response during the study showed disease control in 9 patients (2 patients with partial response and 7 with stable disease, overall response rate of 18%). Our study shows that transarterial chemoembolisation with irinotecan-loaded DC beads (DEBIRI) is safe, technically feasible and effective with a good PK profile.
Breitbandige Beamforming-Algorithmen zur Erfassung von Audiosignalen mit kompakten Mikrofon-Arrays
(2009)
Mikrofon-Arrays erlauben die selektive Erfassung und Trennung von Audiosignalen aus einer akustischen Umgebung. Typische Anwendungen sind z.B. die Ortung einzelner Schallquellen, die räumliche Kartierung eines Schallfeldes ("akustische Kamera") oder der gerichtete Empfang einer bestimmten Schallquelle bei gleichzeitiger Unterdrückung von Umgebungs- oder Störschallen. Vielkanalige Verfahren und Filter, die sich dieser Aufgabe widmen, werden als Beamforming bzw. Beamformer bezeichnet. In dieser Dissertation werden bekannte und eigene Beamforming-Ansätze im Hinblick auf ihre Eignung für die hochwertige Übertragung von Audiosignalen untersucht. Diese erfordert neben einer möglichst großen Abdeckung des relevanten Frequenzbereichs (Breitbandigkeit) auch die Frequenzunabhängigkeit der Richtcharakteristik, um spektrale Verzerrungen zu vermeiden. Es wird ein Algorithmus vorgestellt, der diese Anforderungen mit sehr kompakten Arrays erfüllt. Eine klassische Möglichkeit, eine frequenzinvariante Charakteristik (Beampattern) mithilfe eines Delay-and-Sum-Beamformers zu erhalten, ist eine frequenzabhängige Gewichtung der Mikrofone, welche die effektive Apertur des Arrays proportional zur Schallwellenlänge einstellt. Diese Methode funktioniert jedoch nur bei Wellenlängen, die kleiner sind als die Ausdehnung des Arrays, und erfordert bei Frequenzen unter 100Hz Arrays von mehreren Metern Größe. Ein gänzlich anderes Verhalten zeigen differentielle Mikrofonarrays, welche Differenzen aus Signalen benachbarter Mikrofone bilden: In Kombination mit Integratorfiltern erzeugen sie Beampattern, die auch bei sehr kleinen Frequenzen, d.h. bei Wellenlängen, die groß gegen das Array sind, unverändert bleiben (sog. Superdirektivität). Aus diesem Prinzip wurde in dieser Arbeit das Konzept des Multipol-Beamformers entwickelt, der ein gegebenes Soll-Beampattern durch eine Reihenentwicklung nach Sinus- und Kosinusfunktionen (zweidimensionaler Fall) oder Kugelflächenfunktionen (dreidimensionaler Fall) approximiert. Der Multipol-Beamformer erzielt eine hervorragende Richtwirkung bei kleinen Frequenzen, ist jedoch nur über einen sehr begrenzten Bereich frequenzinvariant und erweist sich insbesondere in drei Raumdimensionen als analytisch aufwändig. Flexibler und in zwei wie in drei Raumdimensionen gleichermaßen einfach in der Formulierung ist demgegenüber das in der Literatur zu findende Verfahren des modalen Subraum-Beamformings (Modal Subspace Decomposition, MSD). Dieser Ansatz bestimmt zu einer beliebigen Sensorgeometrie einen Satz orthogonaler Eigen-Beampattern, die dann zu einer Reihenentwicklung des Soll-Beampatterns herangezogen werden. Ähnlich dem erwähnten Delay-and-Sum-Beamformer jedoch erfordert auch dieser Ansatz bei großen Wellenlängen entsprechend groß dimensionierte Arrays und ist nicht superdirektiv. In dieser Arbeit wurde deshalb eine eigene, neue Ausprägung des MSD-Algorithmus formuliert, welche die Superdirektivität des Multipol-Beamformers mit der Flexibilität und Einfachheit des MSD-Verfahrens vereint. Diese als "superdirektives MSD-Beamforming" bezeichnete Methode besitzt - wie das bereits bekannte MSD-Verfahren auch - die interessante Eigenschaft, daß die Eigen-Beampattern für ein frei zu wählendes Entwurfs-Frequenzband berechnet werden, so daß das Verhalten des Beamformers über ein ganzes Frequenzintervall kontrolliert werden kann. Dies eröffnet auch die Möglichkeit eines sehr breitbandigen Beamformings durch Kombination mehrerer Beamformer, die individuell auf benachbarte Frequenzbänder abgestimmt werden. Mit beispielsweise einem hexagonalen Array von nur 6cm Durchmesser und sieben Mikrofonen erreicht der superdirektive Ansatz so ca. 20-30dB Störabstand über einen Frequenzbereich von 100Hz bis 6kHz, was für Sprache eine sehr hohe Übertragungsqualität darstellt. Zur experimentellen Verifikation der untersuchten Algorithmen wurde im Rahmen dieser Arbeit eine vielkanalige Echtzeit-Signalverarbeitungsumgebung unter Windows XP erstellt, welche die Erfassung, Verarbeitung, Analyse und Ausgabe vielkanaliger Audio-Daten erlaubt. Auch eine Simulation idealer Freifeldmessungen an Mikrofonarrays ist damit möglich, indem die Ausbreitung des Schalls von der Schallquelle zu den Mikrofonen durch zeitdiskrete Fractional-Delay-Filter simuliert wird. Dieser Filtertypus wurden im Rahmen dieser Arbeit ebenfalls eingehend untersucht: Für zwei aus der Literatur bekannte Entwurfsverfahren wurden Erweiterungen gefunden, die bei gleicher Filterordnung eine höhere nutzbare Bandbreite erzielen. Für Messungen an realen Arrays wurde die Akustik-Messkammer des Instituts durch zusätzliche Dämmauskleidung für Freifeld-Messungen nutzbar gemacht. Die Messergebnisse belegen, daß die untersuchten Algorithmen in der Praxis erwartungsgemäß funktionieren und daß der gefundene superdirektive MSD-Algorithmus mit sehr kompakten Arrays eine gute breitbandige Erfassung und Trennung von Audiosignalen ermöglicht.
Gene therapy (GT) is becoming a realistic treatment option for patients with haemophilia. Outside clinical trials, the complexity and potential complications of GT will pose unprecedented challenges to haemophilia care centres.AIM: To explore the potential use of electronic tools to improve the delivery of GT under real-world conditions.METHODS: Considering the hub-and-spoke model, the GTH working group on GT considered the entire patient pathway and reached consensus on requirements for an integrative software tool to secure documenting and sharing information between treaters, pharmacies and patients.RESULTS: Six steps of the gene therapy process were identified, each requiring completion of the previous step as a prerequisite for entry. The responsibilities of GT dosing and follow-up treatment centres, read/write access rules, and the minimum data set were outlined. Data contributed by patients through mobile devices was also considered.CONCLUSION: Important information needs to be shared between patients and treatment centres in a real-world GT hub-and-spoke model. Collecting and sharing this information in well-organised electronic applications will not only improve patient care but also enable national and international data collection in clinical registries...
Objectives: To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. Methods: L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19–103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. Results: A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091–0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867–0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. Conclusions: Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures.
Key Points: Dual-energy CT–derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm 3 vs 80 mg/cm 3 ).
Objectives: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging.
Methods: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard.
Results: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05).
Conclusions: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations.
Key Points
• Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference.
• Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series.
• Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.
To analyze prospectively the interventional and clinical aspects of computed tomography-guided direct intratumoural injection of a novel chemotherapeutic administration and the parenchymal changes of tumour and necrosis in malignant liver tumours. Eight patients with 17 colorectal liver metastases were treated with a mean of 5.1 injections and nine patients with 13 hepatocellular carcinoma nodules with a mean of 3.1 treatments with computed tomography guided local applications of a novel cisplatin/epinephrine gel. This application provides a higher local and lower systemic drug concentration. Volumes of tumour and necrosis prior and after treatment were measured by computer generated volumetric analysis. Contrast enhanced studies verified pretherapeutic viable tumour volumes with a value of 77.4 ml in the metastases and 29.2 ml in the hepatocellular carcinoma nodules. Intratumoural drug application resulted in a significant increase of necrosis and a decrease in viable tumour volume to be 68.3 ml in metastases and 14.5 ml in hepatocellular carcinoma. Local therapy control rate for the follow up to 6 months was 38 and 71% for the group of metastases and hepatocellular carcinoma, respectively. Direct intratumoural injection of cisplatin/epinepthrine injectable gel is a feasible and good tolerated method and results in the development of a statistically significant increase in necrosis in malignant liver tumours. For hepatocellular carcinoma a higher local therapy control rate compared to colorectal metastases can be reported.
Highlights
• MRI and ultrasound provided significant correlations between findings suggestive of vasculitis and the final diagnosis.
• Careful selection of available imaging techniques is warranted considering the time course, location, and clinical history.
• Considering its moderate diagnostic power to distinguish tracer uptake, a holistic view of PET/CT findings is essential.
Abstract
Purpose: To assess the diagnostic value of different imaging modalities in distinguishing systemic vasculitis from other internal and immunological diseases.
Methods: This retrospective study included 134 patients with suspected vasculitis who underwent ultrasound, magnetic resonance imaging (MRI), or 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) between 01/2010 and 01/2019, finally consisting of 70 individuals with vasculitis. The main study parameter was the confirmation of the diagnosis using one of the three different imaging modalities, with the adjudicated clinical and histopathological diagnosis as the gold standard. A secondary parameter was the morphological appearance of the vessel affected by vasculitis.
Results: Patients with systemic vasculitis had myriad clinical manifestations with joint pain as the most common symptom. We found significant correlations between different imaging findings suggestive of vasculitis and the final adjudicated clinical diagnosis. In this context, on MRI, vessel wall thickening, edema, and diameter differed significantly between vasculitis and non-vasculitis groups (p < 0.05). Ultrasound revealed different findings that may serve as red flags in identifying patients with vasculitis, such as vascular occlusion or halo sign (p = 0.02 vs. non-vasculitis group). Interestingly, comparing maximal standardized uptake values from PET/CT examinations with vessel wall thickening or vessel diameter did not result in significant differences (p > 0.05).
Conclusions: We observed significant correlations between different imaging findings suggestive of vasculitis on ultrasound or MRI and the final adjudicated diagnosis. While ultrasound and MRI were considered suitable imaging methods for detecting and discriminating typical vascular changes, 18F-FDG PET/CT requires careful timing and patient selection given its moderate diagnostic accuracy.
Objectives: To determine the diagnostic accuracy of dual-energy CT (DECT) virtual noncalcium (VNCa) reconstructions for assessing thoracic disk herniation compared to standard grayscale CT. Methods: In this retrospective study, 87 patients (1131 intervertebral disks; mean age, 66 years; 47 women) who underwent third-generation dual-source DECT and 3.0-T MRI within 3 weeks between November 2016 and April 2020 were included. Five blinded radiologists analyzed standard DECT and color-coded VNCa images after a time interval of 8 weeks for the presence and degree of thoracic disk herniation and spinal nerve root impingement. Consensus reading of independently evaluated MRI series served as the reference standard, assessed by two separate experienced readers. Additionally, image ratings were carried out by using 5-point Likert scales. Results: MRI revealed a total of 133 herniated thoracic disks. Color-coded VNCa images yielded higher overall sensitivity (624/665 [94%; 95% CI, 0.89–0.96] vs 485/665 [73%; 95% CI, 0.67–0.80]), specificity (4775/4990 [96%; 95% CI, 0.90–0.98] vs 4066/4990 [82%; 95% CI, 0.79–0.84]), and accuracy (5399/5655 [96%; 95% CI, 0.93–0.98] vs 4551/5655 [81%; 95% CI, 0.74–0.86]) for the assessment of thoracic disk herniation compared to standard CT (all p < .001). Interrater agreement was excellent for VNCa and fair for standard CT (ϰ = 0.82 vs 0.37; p < .001). In addition, VNCa imaging achieved higher scores regarding diagnostic confidence, image quality, and noise compared to standard CT (all p < .001). Conclusions: Color-coded VNCa imaging yielded substantially higher diagnostic accuracy and confidence for assessing thoracic disk herniation compared to standard CT.
This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95–23.01) to 2.36 μSv (IQR, 0.52–12.66) (−36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 μSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 μSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (−30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.
Background: Dual-source dual-energy computed tomography (DECT) offers the potential for opportunistic osteoporosis screening by enabling phantomless bone mineral density (BMD) quantification. This study sought to assess the accuracy and precision of volumetric BMD measurement using dual-source DECT in comparison to quantitative CT (QCT). Methods: A validated spine phantom consisting of three lumbar vertebra equivalents with 50 (L1), 100 (L2), and 200 mg/cm3 (L3) calcium hydroxyapatite (HA) concentrations was scanned employing third-generation dual-source DECT and QCT. While BMD assessment based on QCT required an additional standardised bone density calibration phantom, the DECT technique operated by using a dedicated postprocessing software based on material decomposition without requiring calibration phantoms. Accuracy and precision of both modalities were compared by calculating measurement errors. In addition, correlation and agreement analyses were performed using Pearson correlation, linear regression, and Bland-Altman plots. Results: DECT-derived BMD values differed significantly from those obtained by QCT (p < 0.001) and were found to be closer to true HA concentrations. Relative measurement errors were significantly smaller for DECT in comparison to QCT (L1, 0.94% versus 9.68%; L2, 0.28% versus 5.74%; L3, 0.24% versus 3.67%, respectively). DECT demonstrated better BMD measurement repeatability compared to QCT (coefficient of variance < 4.29% for DECT, < 6.74% for QCT). Both methods correlated well to each other (r = 0.9993; 95% confidence interval 0.9984–0.9997; p < 0.001) and revealed substantial agreement in Bland-Altman plots. Conclusions: Phantomless dual-source DECT-based BMD assessment of lumbar vertebra equivalents using material decomposition showed higher diagnostic accuracy compared to QCT.
Purpose: To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography scans (CTA) or a specifically designed phantom model.
Methods: This retrospective study included 23 patients with confirmed TAA on routinely performed CTAs. In addition to phantom tube diameters, one experienced blinded radiologist evaluated the dimensions of TAAs on three different workstations in two separate rounds. Precision was assessed by calculating measurement errors. In addition, correlation analysis was performed using Pearson correlation.
Results: Measurements acquired at the Siemens workstation deviated by 3.54% (range, 2.78–4.03%; p = 0.14) from the true size, those at General Electric by 4.05% (range, 1.46–7.09%; p < 0.0001), and at TeraRecon by 4.86% (range, 3.22–6.45%; p < 0.0001). Accordingly, Siemens provided the most precise workstation at simultaneously most fluctuating values (scattering of 4.46%). TeraRecon had the smallest fluctuation (scattering of 2.83%), but the largest deviation from the true size of the phantom. The workstation from General Electric showed a scattering of 2.94%. The highest overall correlation between the 1st and 2nd rounds was observed with measurements from Siemens (r = 0.898), followed by TeraRecon (r = 0.799), and General Electric (r = 0.703). Repetition of measurements reduced processing times by 40% when using General Electric, by 20% with Siemens, and by 18% with TeraRecon.
Conclusions: In conclusion, all three workstations facilitated precise assessment of dimensions in the majority of cases at simultaneously high reproducibility, ensuring accurate pre-interventional planning of thoracic endovascular aortic repair.
Low serum concentrations of the amino acid homoarginine (HA) are associated with increased cardiovascular mortality by incompletely understood mechanisms. This study sought to assess the influence of HA on cardiac remodeling in rats undergoing either transaortic banding or inhibition of nitric oxide synthesis by Nω-Nitro-L-arginine methyl ester hydrochloride (L-NAME). Male Wistar rats (n = 136) underwent sham operation (SH) or aortic banding (AB). Both groups were equally divided into 14 subgroups, receiving different doses of HA alone or in combination with lisinopril, spironolactone, or L-NAME for 4 weeks. HA treatment in AB animals resulted in a dose-dependent improvement of cardiac function up to a concentration of 800 mg·kg−1·day−1. Combining 800 mg·kg−1·day−1 HA with spironolactone or lisinopril yielded additional effects, showing a positive correlation with LV ejection fraction (+33%, p = 0.0002) and fractional shortening (+41%, p = 0.0014). An inverse association was observed with collagen area fraction (−41%, p < 0.0001), myocyte cross-sectional area (−22%, p < 0.0001) and the molecular markers atrial natriuretic factor (−74%, p = 0.0091), brain natriuretic peptide (−42%, p = 0.0298), beta-myosin heavy chain (−46%, p = 0.0411), and collagen type V alpha 1 chain (−73%, p = 0.0257) compared to placebo-treated AB animals. Co-administration of HA and L-NAME was found to attenuate cardiac remodeling and prevent NO-deficient hypertension following AB. HA treatment has led to a dose-dependent improvement of myocardial function and marked histological and molecular changes in cardiac remodeling following AB. Combining HA with standard heart failure medication resulted in additional beneficial effects boosting its direct impact on heart failure pathophysiology.
TRIANNI mice carry an entire set of human immunoglobulin V region gene segments and are a powerful tool to rapidly isolate human monoclonal antibodies. After immunizing these mice with DNA encoding the spike protein of SARS-CoV-2 and boosting with spike protein, we identified 29 hybridoma antibodies that reacted with the SARS-CoV-2 spike protein. Nine antibodies neutralize SARS-CoV-2 infection at IC50 values in the subnanomolar range. ELISA-binding studies and DNA sequence analyses revealed one cluster of three clonally related neutralizing antibodies that target the receptor-binding domain and compete with the cellular receptor hACE2. A second cluster of six clonally related neutralizing antibodies bind to the N-terminal domain of the spike protein without competing with the binding of hACE2 or cluster 1 antibodies. SARS-CoV-2 mutants selected for resistance to an antibody from one cluster are still neutralized by an antibody from the other cluster. Antibodies from both clusters markedly reduced viral spread in mice transgenic for human ACE2 and protected the animals from SARS-CoV-2-induced weight loss. The two clusters of potent noncompeting SARS-CoV-2 neutralizing antibodies provide potential candidates for therapy and prophylaxis of COVID-19. The study further supports transgenic animals with a human immunoglobulin gene repertoire as a powerful platform in pandemic preparedness initiatives.
Highlights
• Assessment of coronary artery plaque burden according to the CAC-DRS Score correlated well with pulmonary involvement of SARS-CoV-2 pneumonia (min. r=0.81, 95% CI 0.76 to 0.86).
• Visual and quantitative CAC-DRS Score of coronary artery plaque burden provided independent prognostic information on all-cause mortality in patients with SARS-CoV-2 pneumonia (p=0.0016 and p<0.0001, respectively).
• Incorporating CAC-DRS Score and pulmonary involvement into clinical decision making revealed great potential to discriminate patients with fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89 to 0.97) and the need for intensive care treatment (AUC 0.801, 95% CI 0.77 to 0.83).
Purpose: To assess and correlate pulmonary involvement and outcome of SARS-CoV-2 pneumonia with the degree of coronary plaque burden based on the CAC-DRS classification (Coronary Artery Calcium Data and Reporting System).
Methods: This retrospective study included 142 patients with confirmed SARS-CoV-2 pneumonia (58 ± 16 years; 57 women) who underwent non-contrast CT between January 2020 and August 2021 and were followed up for 129 ± 72 days. One experienced blinded radiologist analyzed CT series for the presence and extent of calcified plaque burden according to the visual and quantitative HU-based CAC-DRS Score. Pulmonary involvement was automatically evaluated with a dedicated software prototype by another two experienced radiologists and expressed as Opacity Score.
Results: CAC-DRS Scores derived from visual and quantitative image evaluation correlated well with the Opacity Score (r=0.81, 95% CI 0.76-0.86, and r=0.83, 95% CI 0.77-0.89, respectively; p<0.0001) with higher correlation in severe than in mild stage SARS-CoV-2 pneumonia (p<0.0001). Combined, CAC-DRS and Opacity Scores revealed great potential to discriminate fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89-0.97), and the need for intensive care treatment (AUC 0.801, 95% CI 0.77-0.83). Visual and quantitative CAC-DRS Scores provided independent prognostic information on all-cause mortality (p=0.0016 and p<0.0001, respectively), both in univariate and multivariate analysis.
Conclusions: Coronary plaque burden is strongly correlated to pulmonary involvement, adverse outcome, and death due to respiratory failure in patients with SARS-CoV-2 pneumonia, offering great potential to identify individuals at high risk.
Rationale and Objectives: Lumbar disk degeneration is a common condition contributing significantly to back pain. The objective of the study was to evaluate the potential of dual-energy CT (DECT)-derived collagen maps for the assessment of lumbar disk degeneration.
Patients and Methods: We conducted a retrospective analysis of 127 patients who underwent dual-source DECT and MRI of the lumbar spine between 07/2019 and 10/2022. The level of lumbar disk degeneration was categorized by three radiologists as follows: no/mild (Pfirrmann 1&2), moderate (Pfirrmann 3&4), and severe (Pfirrmann 5). Recall (sensitivity) and accuracy of DECT collagen maps were calculated. Intraclass correlation coefficient (ICC) was used to evaluate inter-reader reliability. Subjective evaluations were performed using 5-point Likert scales for diagnostic confidence and image quality.
Results: We evaluated a total of 762 intervertebral disks from 127 patients (median age, 69.7 (range, 23.0–93.7), female, 56). MRI identified 230 non/mildly degenerated disks (30.2%), 484 moderately degenerated disks (63.5%), and 48 severely degenerated disks (6.3%). DECT collagen maps yielded an overall accuracy of 85.5% (1955/2286). Recall (sensitivity) was 79.3% (547/690) for the detection of no/mild lumbar disk degeneration, 88.7% (1288/1452) for the detection of moderate disk degeneration, and 83.3% (120/144) for the detection of severe disk degeneration (ICC = 0.9). Subjective evaluations of DECT collagen maps showed high diagnostic confidence (median 4) and good image quality (median 4).
Conclusion: The use of DECT collagen maps to distinguish different stages of lumbar disk degeneration may have clinical significance in the early diagnosis of disk-related pathologies in patients with contraindications for MRI or in cases of unavailability of MRI.
Rationale and Objectives: Bone non-union is a serious complication of distal radius fractures (DRF) that can result in functional limitations and persistent pain. However, no accepted method has been established to identify patients at risk of developing bone non-union yet. This study aimed to compare various CT-derived metrics for bone mineral density (BMD) assessment to identify predictive values for the development of bone non-union.
Materials and Methods: CT images of 192 patients with DRFs who underwent unenhanced dual-energy CT (DECT) of the distal radius between 03/2016 and 12/2020 were retrospectively identified. Available follow-up imaging and medical health records were evaluated to determine the occurrence of bone non-union. DECT-based BMD, trabecular Hounsfield unit (HU), cortical HU and cortical thickness ratio were measured in normalized non-fractured segments of the distal radius.
Results: Patients who developed bone non-union were significantly older (median age 72 years vs. 54 years) and had a significantly lower DECT-based BMD (median 68.1 mg/cm3 vs. 94.6 mg/cm3, p < 0.001). Other metrics (cortical thickness ratio, cortical HU, trabecular HU) showed no significant differences. ROC and PR curve analyses confirmed the highest diagnostic accuracy for DECT-based BMD with an area under the curve (AUC) of 0.83 for the ROC curve and an AUC of 0.46 for the PR curve. In logistic regression models, DECT-based BMD was the sole metric significantly associated with bone non-union.
Conclusion: DECT-derived metrics can accurately predict bone non-union in patients who sustained DRF. The diagnostic performance of DECT-based BMD is superior to that of HU-based metrics and cortical thickness ratio.