Refine
Year of publication
Has Fulltext
- yes (686)
Is part of the Bibliography
- no (686)
Keywords
- Heavy Ion Experiments (9)
- LHC (8)
- Hadron-Hadron scattering (experiments) (7)
- ALICE experiment (4)
- Hadron-Hadron Scattering (3)
- Heavy Ions (3)
- Heavy-ion collision (3)
- pp collisions (3)
- ALICE (2)
- Beauty production (2)
- Charm physics (2)
- Diagnostik (2)
- Früherkennung (2)
- Mammakarzinom (2)
- Nachsorge (2)
- Pb–Pb collisions (2)
- Richtlinie (2)
- Single electrons (2)
- breast cancer (2)
- diagnosis (2)
- follow‑up (2)
- guideline (2)
- screening (2)
- ALICE detector (1)
- Anti-nuclei (1)
- Aortic stiffness (1)
- B-cell lymphoma (1)
- Cardiomyocyte signaling pathways (1)
- Cardioprotection (1)
- Cardiovascular disease (1)
- Centrality Class (1)
- Centrality Selection (1)
- Chronic kidney disease (1)
- Comorbidities (1)
- Comparison with QCD (1)
- Congenitally blind (1)
- Drug targeting (1)
- Electron-pion identification (1)
- Elliptic flow (1)
- Endothelial permeability (1)
- Extracellular RNA (eRNA) (1)
- Femtoscopy (1)
- Fibre/foam sandwich radiator (1)
- Functional connectivity (1)
- HBT (1)
- Hadron production (1)
- Heart regeneration (1)
- Heavy flavor production (1)
- Heavy flavour production (1)
- Heavy ions (1)
- Heavy-flavour decay muons (1)
- Heavy-flavour production (1)
- Heavy-ion collisions (1)
- Inclusive spectra (1)
- Induced pluripotent stem cells (1)
- Intensity interferometry (1)
- Invariant Mass Distribution (1)
- Ion channels in the nervous system (1)
- Ionisation energy loss (1)
- Ischemia–reperfusion injury (1)
- Jets (1)
- Lipid metabolism (1)
- MicroRNAs (miRNAs) (1)
- Mid-rapidity (1)
- Minimum Bias (1)
- Mitochondria (1)
- Molecular neuroscience (1)
- Monte Carlo (1)
- Multi-strange baryons (1)
- Multi-wire proportional drift chamber (1)
- Multiphoton microscopy (1)
- Native T1 mapping (1)
- Neural network (1)
- Nuclear modification factor (1)
- Optogenetics (1)
- Oscillations (1)
- Particle correlations and fluctuations (1)
- Pb–Pb (1)
- Perfectionism (1)
- Perfectionism Inventory (1)
- Production Cross Section (1)
- Proton–proton (1)
- QCD (1)
- Quark gluon plasma (1)
- Rapidity Range (1)
- Relativistic heavy ion physics (1)
- Remote ischemic conditioning (1)
- Resolution Parameter (1)
- Single muons (1)
- Systematic Uncertainty (1)
- TR (1)
- Time Projection Chamber (1)
- Tracking (1)
- Training (1)
- Transition radiation detector (1)
- Trigger (1)
- USP9X (1)
- Working memory (1)
- XIAP (1)
- Xenon-based gas mixture (1)
- bifactor model (1)
- bioactivity testing (1)
- confirmatory factor analysis (1)
- construct validation (1)
- dE/dx (1)
- diabetic nephropathy (1)
- drug discovery (1)
- easyPACId (1)
- gene expression (1)
- heavy ion experiments (1)
- interaction effect (1)
- level-specific model fit (1)
- likelihood ratio test (1)
- mitosis (1)
- multilevel structural equation modeling (1)
- natural products (1)
- nuclear factor 2 (erythroid-derived 2-like factor) (NFE2L2) (Nrf2) (1)
- oxidative stress (1)
- perfectionistic concerns (1)
- perfectionistic strivings (1)
- protein-protein interaction (1)
- proteobacteria (1)
- quark gluon plasma (1)
- robust test statistic (1)
- signal transduction (1)
- simplified production (1)
- spectra (1)
- ubiquitin (1)
- √sN N = 2.76 TeV (1)
Institute
The production cross section of electrons from semileptonic decays of beauty hadrons was measured at mid-rapidity (|y|<0.8) in the transverse momentum range 1<pT<8 GeV/c with the ALICE experiment at the CERN LHC in pp collisions at a center of mass energy √s=7 TeV using an integrated luminosity of 2.2 nb−1. Electrons from beauty hadron decays were selected based on the displacement of the decay vertex from the collision vertex. A perturbative QCD calculation agrees with the measurement within uncertainties. The data were extrapolated to the full phase space to determine the total cross section for the production of beauty quark–antiquark pairs.
The inclusive transverse momentum (pT) distributions of primary charged particles are measured in the pseudo-rapidity range |η|<0.8 as a function of event centrality in Pb–Pb collisions at √sNN=2.76 TeV with ALICE at the LHC. The data are presented in the pT range 0.15<pT<50 GeV/c for nine centrality intervals from 70–80% to 0–5%. The results in Pb–Pb are presented in terms of the nuclear modification factor RAA using a pp reference spectrum measured at the same collision energy. We observe that the suppression of high-pT particles strongly depends on event centrality. The yield is most suppressed in central collisions (0–5%) with RAA≈0.13 at pT=6–7 GeV/c. Above pT=7 GeV/c, there is a significant rise in the nuclear modification factor, which reaches RAA≈0.4 for pT>30 GeV/c. In peripheral collisions (70–80%), only moderate suppression (RAA=0.6–0.7) and a weak pT dependence is observed. The measured nuclear modification factors are compared to other measurements and model calculations.
The ALICE Collaboration has made the first measurement at the LHC of J/ψ photoproduction in ultra-peripheral Pb–Pb collisions at sNN=2.76 TeV. The J/ψ is identified via its dimuon decay in the forward rapidity region with the muon spectrometer for events where the hadronic activity is required to be minimal. The analysis is based on an event sample corresponding to an integrated luminosity of about 55 μb−1. The cross section for coherent J/ψ production in the rapidity interval −3.6<y<−2.6 is measured to be dσJ/ψcoh/dy=1.00±0.18(stat)−0.26+0.24(syst) mb. The result is compared to theoretical models for coherent J/ψ production and found to be in good agreement with those models which include nuclear gluon shadowing.
The KASCADE-Grande experiment has significantly contributed to the current knowledge about the energy spectrum and composition of cosmic rays for energies between the knee and the ankle. Meanwhile, post-LHC versions of the hadronic interaction models are available and used to interpret the entire data set of KASCADE-Grande. In addition, a new, combined analysis of both arrays, KASCADE and Grande, was developed significantly increasing the accuracy of the shower observables. First results of the new analysis with the entire data set of the KASCADE-Grande experiment will be the focus of this contribution.
Using CORSIKA for simulating extensive air showers, we study the relation between the shower characteristics and features of hadronic multiparticle production at low energies. We report about investigations of typical energies and phase space regions of secondary particles which are important for muon production in extensive air showers. Possibilities to measure relevant quantities of hadron production in existing and planned accelerator experiments are discussed.
Background: Patients with chronic kidney disease (CKD) have considerable cardiovascular morbidity and mortality. Aortic stiffness is an independent predictor of cardiovascular risk and related to left ventricular remodeling and heart failure. Myocardial fibrosis is the pathophysiological hallmark of the failing heart.
Methods and results: An observational study of consecutive CKD patients (n = 276) undergoing comprehensive clinical cardiovascular magnetic resonance imaging. The relationship between aortic stiffness, myocardial fibrosis, left ventricular remodeling and the severity of chronic kidney disease was examined. Compared to age-gender matched controls with no known kidney disease (n = 242), CKD patients had considerably higher myocardial native T1 and central aortic PWV (p ≪ 0.001), as well as abnormal diastolic relaxation by E/e′ (mean) by echocardiography (p ≪ 0.01). A third of all patients had LGE, with similar proportions for the presence and the (ischaemic and non-ischaemic) pattern between the groups. PWV was strongly associated with and age, NT-proBNP and native T1 in both groups, but not with LGE presence or type; the associations were amplified in severe CKD stages. In multivariate analyses, PWV was independently associated with native T1 in both groups (p ≪ 0.01) with near two-fold increase in adjusted R2 in the presence of CKD (native T1 (10 ms) R2, B(95%CI) CKD vs. non-CKD 0.28, 0.2(0.15–0.25) vs. 0.18, 0.1(0.06–0.15), p ≪ 0.01).
Conclusions: Aortic stiffness and interstitial myocardial fibrosis are interrelated; this association is accelerated in the presence of CKD, but independent of LGE. Our findings reiterate the significant contribution of CKD-related factors to the pathophysiology of cardiovascular remodeling.
The mitotic spindle assembly checkpoint (SAC) maintains genome stability and marks an important target for antineoplastic therapies. However, it has remained unclear how cells execute cell fate decisions under conditions of SAC‐induced mitotic arrest. Here, we identify USP9X as the mitotic deubiquitinase of the X‐linked inhibitor of apoptosis protein (XIAP) and demonstrate that deubiquitylation and stabilization of XIAP by USP9X lead to increased resistance toward mitotic spindle poisons. We find that primary human aggressive B‐cell lymphoma samples exhibit high USP9X expression that correlate with XIAP overexpression. We show that high USP9X/XIAP expression is associated with shorter event‐free survival in patients treated with spindle poison‐containing chemotherapy. Accordingly, aggressive B‐cell lymphoma lines with USP9X and associated XIAP overexpression exhibit increased chemoresistance, reversed by specific inhibition of either USP9X or XIAP. Moreover, knockdown of USP9X or XIAP significantly delays lymphoma development and increases sensitivity to spindle poisons in a murine Eμ‐Myc lymphoma model. Together, we specify the USP9X–XIAP axis as a regulator of the mitotic cell fate decision and propose that USP9X and XIAP are potential prognostic biomarkers and therapeutic targets in aggressive B‐cell lymphoma.
Evaluating model fit in nonlinear multilevel structural equation models (MSEM) presents a challenge as no adequate test statistic is available. Nevertheless, using a product indicator approach a likelihood ratio test for linear models is provided which may also be useful for nonlinear MSEM. The main problem with nonlinear models is that product variables are non-normally distributed. Although robust test statistics have been developed for linear SEM to ensure valid results under the condition of non-normality, they have not yet been investigated for nonlinear MSEM. In a Monte Carlo study, the performance of the robust likelihood ratio test was investigated for models with single-level latent interaction effects using the unconstrained product indicator approach. As overall model fit evaluation has a potential limitation in detecting the lack of fit at a single level even for linear models, level-specific model fit evaluation was also investigated using partially saturated models. Four population models were considered: a model with interaction effects at both levels, an interaction effect at the within-group level, an interaction effect at the between-group level, and a model with no interaction effects at both levels. For these models the number of groups, predictor correlation, and model misspecification was varied. The results indicate that the robust test statistic performed sufficiently well. Advantages of level-specific model fit evaluation for the detection of model misfit are demonstrated.
Profiles of CFC-11 (CCl3F) and CFC-12 (CCl2F2) of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) aboard the European satellite Envisat have been retrieved from versions MIPAS/4.61 to MIPAS/4.62 and MIPAS/5.02 to MIPAS/5.06 level-1b data using the scientific level-2 processor run by Karlsruhe Institute of Technology (KIT), Institute of Meteorology and Climate Research (IMK) and Consejo Superior de Investigaciones Científicas (CSIC), Instituto de Astrofísica de Andalucía (IAA). These profiles have been compared to measurements taken by the balloon-borne cryosampler, Mark IV (MkIV) and MIPAS-Balloon (MIPAS-B), the airborne MIPAS-STRatospheric aircraft (MIPAS-STR), the satellite-borne Atmospheric Chemistry Experiment Fourier transform spectrometer (ACE-FTS) and the High Resolution Dynamic Limb Sounder (HIRDLS), as well as the ground-based Halocarbon and other Atmospheric Trace Species (HATS) network for the reduced spectral resolution period (RR: January 2005–April 2012) of MIPAS. ACE-FTS, MkIV and HATS also provide measurements during the high spectral resolution period (full resolution, FR: July 2002–March 2004) and were used to validate MIPAS CFC-11 and CFC-12 products during that time, as well as profiles from the Improved Limb Atmospheric Spectrometer, ILAS-II. In general, we find that MIPAS shows slightly higher values for CFC-11 at the lower end of the profiles (below ∼ 15 km) and in a comparison of HATS ground-based data and MIPAS measurements at 3 km below the tropopause. Differences range from approximately 10 to 50 pptv ( ∼ 5–20 %) during the RR period. In general, differences are slightly smaller for the FR period. An indication of a slight high bias at the lower end of the profile exists for CFC-12 as well, but this bias is far less pronounced than for CFC-11 and is not as obvious in the relative differences between MIPAS and any of the comparison instruments. Differences at the lower end of the profile (below ∼ 15 km) and in the comparison of HATS and MIPAS measurements taken at 3 km below the tropopause mainly stay within 10–50 pptv (corresponding to ∼ 2–10 % for CFC-12) for the RR and the FR period. Between ∼ 15 and 30 km, most comparisons agree within 10–20 pptv (10–20 %), apart from ILAS-II, which shows large differences above ∼ 17 km. Overall, relative differences are usually smaller for CFC-12 than for CFC-11. For both species – CFC-11 and CFC-12 – we find that differences at the lower end of the profile tend to be larger at higher latitudes than in tropical and subtropical regions. In addition, MIPAS profiles have a maximum in their mixing ratio around the tropopause, which is most obvious in tropical mean profiles. Comparisons of the standard deviation in a quiescent atmosphere (polar summer) show that only the CFC-12 FR error budget can fully explain the observed variability, while for the other products (CFC-11 FR and RR and CFC-12 RR) only two-thirds to three-quarters can be explained. Investigations regarding the temporal stability show very small negative drifts in MIPAS CFC-11 measurements. These instrument drifts vary between ∼ 1 and 3 % decade−1. For CFC-12, the drifts are also negative and close to zero up to ∼ 30 km. Above that altitude, larger drifts of up to ∼ 50 % decade−1 appear which are negative up to ∼ 35 km and positive, but of a similar magnitude, above.
The ENVISAT validation programme for the atmospheric instruments MIPAS, SCIAMACHY and GOMOS is based on a number of balloon-borne, aircraft, satellite and ground-based correlative measurements. In particular the activities of validation scientists were coordinated by ESA within the ENVISAT Stratospheric Aircraft and Balloon Campaign or ESABC. As part of a series of similar papers on other species [this issue] and in parallel to the contribution of the individual validation teams, the present paper provides a synthesis of comparisons performed between MIPAS CH4 and N2O profiles produced by the current ESA operational software (Instrument Processing Facility version 4.61 or IPF v4.61, full resolution MIPAS data covering the period 9 July 2002 to 26 March 2004) and correlative measurements obtained from balloon and aircraft experiments as well as from satellite sensors or from ground-based instruments. In the middle stratosphere, no significant bias is observed between MIPAS and correlative measurements, and MIPAS is providing a very consistent and global picture of the distribution of CH4 and N2O in this region. In average, the MIPAS CH4 values show a small positive bias in the lower stratosphere of about 5%. A similar situation is observed for N2O with a positive bias of 4%. In the lower stratosphere/upper troposphere (UT/LS) the individual used MIPAS data version 4.61 still exhibits some unphysical oscillations in individual CH4 and N2O profiles caused by the processing algorithm (with almost no regularization). Taking these problems into account, the MIPAS CH4 and N2O profiles are behaving as expected from the internal error estimation of IPF v4.61 and the estimated errors of the correlative measurements.