Background: Vacuum cleaning, which is associated with musculoskeletal complaints, is frequently carried out in private households and by professional cleaners. The aim of this pilot study was to quantify the movements during habitual vacuuming and to characterize the movement profile with regard to its variability. Methods: The data were collected from 31 subjects (21 f/10 m) using a 3D motion analysis system (XSens). Eight vacuum cleaners were used to vacuum polyvinyl chloride (PVC) and carpet floors. In 15 joints of the right upper extremity, the trunk and the lower extremities, Principal Component Analysis was used to determine the predominantly varying joints during vacuuming. Results: The movements of the trunk and the lower extremities were relatively constant and, therefore, had less influence. The shoulder, elbow and wrist joints were identified as joints that can be decisive for the movement profile and that can be influenced. These joints were represented in the course of the vacuuming cycle by the mean movement with its standard deviation. Conclusion: In summary, the generalization of a movement profile is possible for the trunk and the lower extremities due to the relative homogeneity. In future it will be necessary to identify factors influencing variability in order to draw conclusions about movement ergonomics.
Background: Musculoskeletal disorders (MSD) are common among dental professionals. The most common areas affected are the trunk, neck, shoulders and wrists. Current evidence suggests that the causes of MSD can be found in the physical demands of the profession. Posture and movement during treatment is influenced by the arrangement of the treatment concept (patient chair, equipment and cabinets). It has not been investigated whether the ergonomic risk differs between the treatment concepts.
Methods: To evaluate the prevalence of MSD in dental professionals, 1000 responses will be collected from a nationwide (Germany) online questionnaire (mod. Nordic Questionnaire and mod. Meyer questionnaire). In order to assess the ergonomic risk of the treatment techniques used in the four treatment concepts, 3D movement analyses are carried out with inertial sensors. For this purpose, 20 teams of dentists and dental assistants from four dental fields of specializations (generalists, orthodontists, endodontists and oral surgeons) and a student control group will be recruited. Each team will execute field specific standardized treatments at a dummy head. Measurements are carried out in each of the four treatment concepts. The data will be analyzed using the Rapid Upper Limb Assessment (RULA) which will be modified for the evaluation of objective data.
Conclusions: On the basis of these investigations, a substantial gain of knowledge regarding work-related MSD in the field of dentistry and its potential biomechanical causes is possible. For the first time, objective and differentiated comparisons between the four treatment concepts are possible for different fields of dental specialization. Up to now, statically held positions of the trunk and proximal upper extremities, but also the repetitive movements of the hands have been considered a risk for MSD. Since both are included in the RULA, dental activities can be assessed in a detailed but also global manner with regard to ergonomic risks.
Zur ergonomischen Beurteilung von Arbeitsplätzen werden „ergonomic risk assessment tools“ (ERAT) verwendet. Mithilfe dieser kann die körperliche Belastung evaluiert und hinsichtlich eines biomechanischen Überlastungsrisikos bewertet werden. Dazu gehören neben Eigenangaben auch observatorische Methoden, deren Ergebnisse in Punktwerten („Scores“) zusammengefasst werden, wie z. B. die RULAMethode („rapid upper limb assessment“). Durch die technische Weiterentwicklung direkter Messmethoden können inertiale Motion-Capture-Systeme im 21. Jahrhundert präzise und kontinuierliche objektive Daten liefern. In einem neuen Ansatz wurde die observatorische Scoring-Methode RULA modifiziert und auf die digital erhobenen Daten angewendet, was differenzierte ergonomische Betrachtungen ganzer Arbeitsabläufe ermöglicht.
Background: In clinical practice range of motion (RoM) is usually assessed with low-cost devices such as a tape measure (TM) or a digital inclinometer (DI). However, the intra- and inter-rater reliability of typical RoM tests differ, which impairs the evaluation of therapy progress. More objective and reliable kinematic data can be obtained with the inertial motion capture system (IMC) by Xsens. The aim of this study was to obtain the intra- and inter-rater reliability of the TM, DI and IMC methods in five RoM tests: modified Thomas test (DI), shoulder test modified after Janda (DI), retroflexion of the trunk modified after Janda (DI), lateral inclination (TM) and fingertip-to-floor test (TM).
Methods: Two raters executed the RoM tests (TM or DI) in a randomized order on 22 healthy individuals while, simultaneously, the IMC data (Xsens MVN) was collected. After 15 warm-up repetitions, each rater recorded five measurements.
Findings: Intra-rater reliabilities were (almost) perfect for tests in all three devices (ICCs 0.886–0.996). Inter-rater reliability was substantial to (almost) perfect in the DI (ICCs 0.71–0.87) and the IMC methods (ICCs 0.61–0.993) and (almost) perfect in the TM methods (ICCs 0.923–0.961). The measurement error (ME) for the tests measured in degree (°) was 0.9–3.3° for the DI methods and 0.5–1.2° for the IMC approaches. In the tests measured in centimeters the ME was 0.5–1.3cm for the TM methods and 0.6–2.7cm for the IMC methods. Pearson correlations between the results of the DI or the TM respectively with the IMC results were significant in all tests except for the shoulder test on the right body side (r = 0.41–0.81).
Interpretation: Measurement repetitions of either one or multiple trained raters can be considered reliable in all three devices.
In the application of range of motion (ROM) tests there is little agreement on the number of repetitions to be measured and the number of preceding warm-up protocols. In stretch training a plateau in ROM gains can be seen after four to five repetitions. With increasing number of repetitions, the gain in ROM is reduced. This study examines the question of whether such an effect occurs in common ROM tests. Twenty-two healthy sport students (10 m/12 f.) with an average age of 25.3 ± 1.94 years (average height 174.1 ± 9.8 cm; weight 66.6 ± 11.3 kg and BMI 21.9 ± 2.0 kg/cm2) volunteered in this study. Each subject performed five ROM tests in a randomized order—measured either via a tape measure or a digital inclinometer: Tape measure was used to evaluate the Fingertip-to-Floor test (FtF) and the Lateral Inclination test (LI). Retroflexion of the trunk modified after Janda (RF), Thomas test (TT) and a Shoulder test modified after Janda (ST) were evaluated with a digital inclinometer. In order to show general acute effects within 20 repetitions we performed ANOVA/Friedman-test with multiple comparisons. A non-linear regression was then performed to identify a plateau formation. Significance level was set at 5%. In seven out of eight ROM tests (five tests in total with three tests measured both left and right sides) significant flexibility gains were observed (FtF: p < 0.001; LI-left/right: p < 0.001/0.001; RF: p = 0.009; ST-left/right: p < 0.001/p = 0.003; TT-left: p < 0.001). A non-linear regression with random effects was successfully applied on FtF, RF, LI-left/right, ST-left and TT-left and thus, indicate a gradual decline in the amount of gained ROM. An acute effect was observed in most ROM tests, which is characterized by a gradual decline of ROM gain. For those tests, we can state that the acute effect described in the stretching literature also applies to the performance of typical ROM tests. Since a non-linear behavior was shown, it is the decision of the practitioner to weigh up between measurement accuracy and expenditure. Researchers and practitioners should consider this when applying ROM assessments to healthy young adults.