Refine
Year of publication
Document Type
- Article (338)
- Preprint (129)
- Part of Periodical (7)
- Conference Proceeding (4)
- Contribution to a Periodical (3)
- Book (2)
- Review (1)
Has Fulltext
- yes (484)
Keywords
- BESIII (15)
- Branching fraction (9)
- e +-e − Experiments (9)
- Hadronic decays (5)
- Particle and Resonance Production (5)
- Quarkonium (5)
- SARS-CoV-2 (5)
- Branching fractions (4)
- Lepton colliders (4)
- COVID-19 (3)
Institute
- Physik (338)
- Medizin (45)
- Frankfurt Institute for Advanced Studies (FIAS) (38)
- Geowissenschaften (17)
- Biowissenschaften (7)
- Ernst Strüngmann Institut (5)
- MPI für Hirnforschung (5)
- Biochemie, Chemie und Pharmazie (3)
- Extern (3)
- Geowissenschaften / Geographie (3)
Cloud microphysical processes involving the ice phase in tropospheric clouds are among the major uncertainties in cloud formation, weather, and general circulation models. The detection of aerosol particles, liquid droplets, and ice crystals, especially in the small cloud particle-size range below 50 μm, remains challenging in mixed phase, often unstable environments. The Cloud Aerosol Spectrometer with Polarization (CASPOL) is an airborne instrument that has the ability to detect such small cloud particles and measure the variability in polarization state of their backscattered light. Here we operate the versatile Cosmics Leaving OUtdoor Droplets (CLOUD) chamber facility at the European Organization for Nuclear Research (CERN) to produce controlled mixed phase and other clouds by adiabatic expansions in an ultraclean environment, and use the CASPOL to discriminate between different aerosols, water, and ice particles. In this paper, optical property measurements of mixed-phase clouds and viscous secondary organic aerosol (SOA) are presented. We report observations of significant liquid–viscous SOA particle polarization transitions under dry conditions using CASPOL. Cluster analysis techniques were subsequently used to classify different types of particles according to their polarization ratios during phase transition. A classification map is presented for water droplets, organic aerosol (e.g., SOA and oxalic acid), crystalline substances such as ammonium sulfate, and volcanic ash. Finally, we discuss the benefits and limitations of this classification approach for atmospherically relevant concentrations and mixtures with respect to the CLOUD 8–9 campaigns and its potential contribution to tropical troposphere layer analysis.
The current pandemic situation caused by the Betacoronavirus SARS-CoV-2 (SCoV2) highlights the need for coordinated research to combat COVID-19. A particularly important aspect is the development of medication. In addition to viral proteins, structured RNA elements represent a potent alternative as drug targets. The search for drugs that target RNA requires their high-resolution structural characterization. Using nuclear magnetic resonance (NMR) spectroscopy, a worldwide consortium of NMR researchers aims to characterize potential RNA drug targets of SCoV2. Here, we report the characterization of 15 conserved RNA elements located at the 5′ end, the ribosomal frameshift segment and the 3′-untranslated region (3′-UTR) of the SCoV2 genome, their large-scale production and NMR-based secondary structure determination. The NMR data are corroborated with secondary structure probing by DMS footprinting experiments. The close agreement of NMR secondary structure determination of isolated RNA elements with DMS footprinting and NMR performed on larger RNA regions shows that the secondary structure elements fold independently. The NMR data reported here provide the basis for NMR investigations of RNA function, RNA interactions with viral and host proteins and screening campaigns to identify potential RNA binders for pharmaceutical intervention.
Background & aims: Current guidelines recommend immunosuppressive treatment (IT) in patients with primary sclerosing cholangitis (PSC) and elevated aminotransferase levels more than five times the upper limit of normal and elevated serum IgG-levels above twice the upper limit of normal. Since there is no evidence to support this recommendation, we aimed to assess the criteria that guided clinicians in clinical practice to initiate IT in patients with previously diagnosed PSC.
Methods: This is a retrospective analysis of 196 PSC patients from seven German hepatology centers, of whom 36 patients had received IT solely for their liver disease during the course of PSC. Analyses were carried out using methods for competing risks.
Results: A simplified autoimmune hepatitis (AIH) score >5 (HR of 36, p<0.0001) and a modified histological activity index (mHAI) greater than 3/18 points (HR 3.6, p = 0.0274) were associated with the initiation of IT during the course of PSC. Of note, PSC patients who subsequently received IT differed already at the time of PSC diagnosis from those patients, who did not receive IT during follow-up: they presented with increased levels of IgG (p = 0.004) and more frequently had clinical signs of cirrhosis (p = 0.0002).
Conclusions: This is the first study which investigates the parameters associated with IT in patients with PSC in clinical practice. A simplified AIH score >5 and a mHAI score >3, suggesting concomitant features of AIH, influenced the decision to introduce IT during the course of PSC. In German clinical practice, the cutoffs used to guide IT may be lower than recommended by current guidelines.
Assessment of individual therapeutic responses provides valuable information concerning treatment benefits in individual patients. We evaluated individual therapeutic responses as determined by the Disease Activity Score-28 joints critical difference for improvement (DAS28-dcrit) in rheumatoid arthritis (RA) patients treated with intravenous tocilizumab or comparator anti-tumor necrosis factor (TNF) agents. The previously published DAS28-dcrit value [DAS28 decrease (improvement) ≥ 1.8] was retrospectively applied to data from two studies of tocilizumab in RA, the 52-week ACT-iON observational study and the 24-week ADACTA randomized study. Data were compared within (not between) studies. DAS28 was calculated with erythrocyte sedimentation rate as the inflammatory marker. Stability of DAS28-dcrit responses and European League Against Rheumatism (EULAR) good responses was determined by evaluating repeated responses at subsequent timepoints. A logistic regression model was used to calculate p values for differences in response rates between active agents. Patient-reported outcomes (PROs; pain, global health, function, and fatigue) in DAS28-dcrit responder versus non-responder groups were compared with an ANCOVA model. DAS28-dcrit individual response rates were 78.2% in tocilizumab-treated patients and 58.2% in anti-TNF-treated patients at week 52 in the ACT-ion study (p = 0.0001) and 90.1% versus 59.1% at week 24 in the ADACTA study (p < 0.0001). DAS28-dcrit responses showed greater stability over time (up to 52 weeks) than EULAR good responses. For both active treatments, DAS28-dcrit responses were associated with statistically significant improvements in mean PRO values compared with non-responders. The DAS28-dcrit response criterion provides robust assessments of individual responses to RA therapy and may be useful for discriminating between active agents in clinical studies and guiding treat-to-target decisions in daily practice.
In order to gain further insights into early solar system aggregation processes, we carried out an experiment on board the International Space Station, which allowed us to study the behavior of dust particles exposed to electric arc discharges under long-term microgravity. The experiment led to the formation of robust, elongated, fluffy aggregates, which were studied by scanning electron microscopy, electron backscatter diffraction, and synchrotron micro-computed tomography. The morphologies of these aggregates strongly resemble the typical shapes of fractal fluffy-type calcium-aluminum-rich inclusions (CAIs). We conclude that a small amount of melting could have supplied the required stability for such fractal structures to have survived transportation and aggregation to and compaction within planetesimals. Other aggregates produced in our experiment have a massy morphology and contain relict grains, likely resulting from the collision of grains with different degrees of melting, also observed in some natural CAIs. Some particles are surrounded by igneous rims, which remind in thickness and crystal orientation of Wark–Lovering rims; another aggregate shows similarities to disk-shaped CAIs. These results imply that a (flash-)heating event with subsequent aggregation could have been involved in the formation of different morphological CAI characteristics.
Accurate measurement of the standard 235U(n,f) cross section from thermal to 170 keV neutron energy
(2020)
An accurate measurement of the 235U(n,f) cross section from thermal to 170 keV of neutron energy has recently been performed at n_TOF facility at CERN using 6Li(n,t)4He and 10B(n,α)7Li as references. This measurement has been carried out in order to investigate a possible overestimation of the 235U fission cross section evaluation provided by most recent libraries between 10 and 30 keV. A custom experimental apparatus based on in-beam silicon detectors has been used, and a Monte Carlo simulation in GEANT4 has been employed to characterize the setup and calculate detectors efficiency. The results evidenced the presence of an overestimation in the interval between 9 and 18 keV and the new data may be used to decrease the uncertainty of 235U(n,f) cross section in the keV region.
Accurate neutron capture cross section data for minor actinides (MAs) are required to estimate the production and transmutation rates of MAs in light water reactors with a high burnup, critical fast reactors like Gen-IV systems and other innovative reactor systems such as accelerator driven systems (ADS). Capture reactions of 244Cm open the path for the formation of heavier Cm isotopes and of heavier elements such as Bk and Cf. In addition, 244Cm shares nearly 50% of the total actinide decay heat in irradiated reactor fuels with a high burnup, even after three years of cooling.
Experimental data for this isotope are very scarce due to the difficulties of providing isotopically enriched samples and because the high intrinsic activity of the samples requires the use of neutron facilities with high instantaneous flux. The only two previous experimental data sets for this neutron capture cross section have been obtained in 1969 using a nuclear explosion and, more recently, at J-PARC in 2010. The neutron capture cross sections have been measured at n_TOF with the same samples that the previous experiments in J-PARC. The samples were measured at n_TOF Experimental Area 2 (EAR-2) with three C6D6 detectors and also in Experimental Area 1 (EAR-1) with the Total Absorption Calorimeter (TAC). Preliminary results assessing the quality and limitations of these new experimental datasets are presented for the experiments in both areas. Preliminary yields of both measurements will be compared with evaluated libraries for the first time.
233U is the fissile nuclei in the Th-U fuel cycle with a particularily small neutron capture cross setion which is on average about one order of magnitude lower than its fission cross section. Hence, the measurement of the 233U(n, γ) cross section relies on a method to accurately distinguish between capture and fission γ-rays. A measurement of the 233U α-ratio has been performed at the n_TOF facility at CERN using a so-called fission tagging setup, coupling n_TOF 's Total Absorption Calorimeter with a novel fission chamber to tag the fission γ-rays. The experimental setup is described and essential parts of the analysis are discussed. Finally, a preliminary 233U α-ratio is presented.
We have measured the capture cross section of the 155Gd and 157Gd isotopes between 0.025 eV and 1 keV. The capture events were recorded by an array of 4 C6D6 detectors, and the capture yield was deduced exploiting the total energy detection system in combination with the Pulse Height Weighting Techniques. Because of the large cross section around thermal neutron energy, 4 metallic samples of different thickness were used to prevent problems related to self-shielding. The samples were isotopically enriched, with a cross contamination of the other isotope of less than 1.14%. The capture yield was analyzed with an R-Matrix code to describe the cross section in terms of resonance parameters. Near thermal energies, the results are significantly different from evaluations and from previous time-of-flight experiments. The data from the present measurement at n_TOF are publicly available in the experimental nuclear reaction database EXFOR.
Feasibility, design and sensitivity studies on innovative nuclear reactors that could address the issue of nuclear waste transmutation using fuels enriched in minor actinides, require high accuracy cross section data for a variety of neutron-induced reactions from thermal energies to several tens of MeV. The isotope 241Am (T1/2= 433 years) is present in high-level nuclear waste (HLW), representing about 1.8 % of the actinide mass in spent PWR UOx fuel. Its importance increases with cooling time due to additional production from the β-decay of 241Pu with a half-life of 14.3 years. The production rate of 241 Am in conventional reactors, including its further accumulation through the decay of 241Pu and its destruction through transmutation/incineration are very important parameters for the design of any recycling solution. In the present work, the 241 Am(n,f) reaction cross-section was measured using Micromegas detectors at the Experimental Area 2 of the n_TOF facility at CERN. For the measurement, the 235U(n,f) and 238U(n,f) reference reactions were used for the determination of the neutron flux. In the present work an overview of the experimental setup and the adopted data analysis techniques is given along with preliminary results.
233U is of key importance among the fissile nuclei in the Th-U fuel cycle. A particularity of 233U is its small neutron capture cross-section, which is on average about one order of magnitude lower than the fission cross-section. The accuracy in the measurement of the 233U capture cross-section depends crucially on an efficient capture-fission discrimination, thus a combined set-up of fission and γ-detectors is needed. A measurement of the 233U capture cross-section and capture-to-fission ratio was performed at the CERN n_TOF facility. The Total Absorption Calorimeter (TAC) of n_TOF was employed as γ-detector coupled with a novel compact ionization chamber as fission detector. A brief description of the experimental set-up will be given, and essential parts of the analysis procedure as well as the preliminary response of the set-up to capture are presented and discussed.
The KASCADE-Grande experiment has significantly contributed to the current knowledge about the energy spectrum and composition of cosmic rays for energies between the knee and the ankle. Meanwhile, post-LHC versions of the hadronic interaction models are available and used to interpret the entire data set of KASCADE-Grande. In addition, a new, combined analysis of both arrays, KASCADE and Grande, was developed significantly increasing the accuracy of the shower observables. First results of the new analysis with the entire data set of the KASCADE-Grande experiment will be the focus of this contribution.
The (n, γ) cross sections of the gadolinium isotopes play an important role in the study of the stellar nucleosynthesis. In particular, among the isotopes heavier than Fe, 154Gd together with 152Gd have the peculiarity to be mainly produced by the slow capture process, the so-called s-process, since they are shielded against the β-decay chains from the r-process region by their stable samarium isobars. Such a quasi pure s-process origin makes them crucial for testing the robustness of stellar models in galactic chemical evolution (GCE). According to recent models, the 154Gd and 152Gd abundances are expected to be 15-20% lower than the reference un-branched s-process 150Sm isotope. The close correlation between stellar abundances and neutron capture cross sections prompted for an accurate measurement of 154Gd cross section in order to reduce the uncertainty attributable to nuclear physics input and eventually rule out one of the possible causes of present discrepancies between observation and model predictions. To this end, the neutron capture cross section of 154Gd was measured in a wide neutron energy range (from thermal up to some keV) with high resolution in the first experimental area of the neutron time-of-flight facility n_TOF (EAR1) at CERN. In this contribution, after a brief description of the motivation and of the experimental setup used in the measurement, the preliminary results of the 154Gd neutron capture reaction as well as their astrophysical implications are presented.
Monte Carlo simulations and n-p differential scattering data measured with Proton Recoil Telescopes
(2020)
The neutron-induced fission cross section of 235U, a standard at thermal energy and between 0.15 MeV and 200 MeV, plays a crucial role in nuclear technology applications. The long-standing need of improving cross section data above 20 MeV and the lack of experimental data above 200 MeV motivated a new experimental campaign at the n_TOF facility at CERN. The measurement has been performed in 2018 at the experimental area 1 (EAR1), located at 185 m from the neutron-producing target (the experiment is presented by A. Manna et al. in a contribution to this conference). The 235U(n,f) cross section from 20 MeV up to about 1 GeV has been measured relative to the 1H(n,n)1H reaction, which is considered the primary reference in this energy region. The neutron flux impinging on the 235U sample (a key quantity for determining the fission events) has been obtained by detecting recoil protons originating from n-p scattering in a C2H4 sample. Two Proton Recoil Telescopes (PRT), consisting of several layers of solid-state detectors and fast plastic scintillators, have been located at proton scattering angles of 25.07° and 20.32°, out of the neutron beam. The PRTs exploit the ΔE-E technique for particle identification, a basic requirement for the rejection of charged particles from neutron-induced reactions in carbon. Extensive Monte Carlo simulations were performed to characterize proton transport through the different slabs of silicon and scintillation detectors, to optimize the experimental set-up and to deduce the efficiency of the whole PRT detector. In this work we compare measured data collected with the PRTs with a full Monte Carlo simulation based on the Geant-4 toolkit.
Since the start of its operation in 2001, based on an idea of Prof. Carlo Rubbia [1], the neutron time of-flight facility of CERN, n_TOF, has become one of the most forefront neutron facilities in the world for wide-energy spectrum neutron cross section measurements. Thanks to the combination of excellent neutron energy resolution and high instantaneous neutron flux available in the two experimental areas, the second of which has been constructed in 2014, n_TOF is providing a wealth of new data on neutron-induced reactions of interest for nuclear astrophysics, advanced nuclear technologies and medical applications. The unique features of the facility will continue to be exploited in the future, to perform challenging new measurements addressing the still open issues and long-standing quests in the field of neutron physics. In this document the main characteristics of the n_TOF facility and their relevance for neutron studies in the different areas of research will be outlined, addressing the possible future contribution of n_TOF in the fields of nuclear astrophysics, nuclear technologies and medical applications. In addition, the future perspectives of the facility will be described including the upgrade of the spallation target, the setup of an imaging installation and the construction of a new irradiation area.
Neutron-induced fission cross sections of isotopes involved in the nuclear fuel cycle are vital for the design and safe operation of advanced nuclear systems. Such experimental data can also provide additional constraints for the adjustment of nuclear model parameters used in the evaluation process, resulting in the further development of fission models. In the present work, the 237Np(n,f) cross section was studied at the EAR2 vertical beam-line at CERN's n_TOF facility, over a wide range of neutron energies, from meV to MeV, using the time-of-flight technique and a set-up based on Micromegas detectors, in an attempt to provide accurate experimental data. Preliminary results in the 200 keV – 14 MeV neutron energy range as well as the experimental procedure, including a description of the facility and the data handling and analysis, will be presented.
We have measured the γ-rays following neutron capture on 240Pu and 244 Cm at the n_TOF facility at CERN with the Total Absorption Calorimeter (TAC) and with C6D6 organic scintillators. The TAC is made of 40 BaF2 crystals operating in coincidence and covering almost the entire solid angle. This allows to obtain information concerning the energy spectra and the multiplicity of the measured capture γ-ray cascades. Additional information is also obtained from the C6D6 detectors. We have analyzed the measured data in order to draw conclusions about the Photon Strength Functions (PSFs) of 241Pu and 245Cm below their neutron separation energies. The analysis has been performed by fitting the PSFs to the experimental results, using the differential evolution method, in order to find neutron capture cascades capable of reproducing at the same time a great variety of deposited energy spectra.
The study of neutron-induced reactions on actinides is of considerable importance for the design of advanced nuclear systems and alternative fuel cycles. Specifically, 230Th is produced from the α-decay of 234U as a byproduct of the 232Th/233U fuel cycle, thus the accurate knowledge of its fission cross section is strongly required. However, few experimental datasets exist in literature with large deviations among them, covering the energy range between 0.2 to 25 MeV. In addition, the study of the 230Th(n,f) cross-section is of great interest in the research on the fission process related to the structure of the fission barriers. Previous measurements have revealed a large resonance at En=715 keV and additional fine structures, but with high discrepancies among the cross-section values of these measurements. This contribution presents preliminary results of the 230Th(n,f) cross-section measurements at the CERN n_TOF facility. The high purity targets of the natural, but very rare isotope 230Th, were produced at JRC-Geel in Belgium. The measurements were performed at both experimental areas (EAR-1 and EAR-2) of the n_TOF facility, covering a very broad energy range from thermal up to at least 100 MeV. The experimental setup was based on Micromegas detectors with the 235U(n,f) and 238U(n,f) reaction cross-sections used as reference.
New measurements of the 7Be(n,α)4He and 7Be(n,p)7Li reaction cross sections from thermal to keV neutron energies have been recently performed at CERN/n_TOF. Based on the new experimental results, astrophysical reaction rates have been derived for both reactions, including a proper evaluation of their uncertainties in the thermal energy range of interest for big bang nucleosynthesis studies. The new estimate of the 7Be destruction rate, based on these new results, yields a decrease of the predicted cosmological 7Li abundance insufficient to provide a viable solution to the cosmological lithium problem.
The design and operation of innovative nuclear systems requires a better knowledge of the capture and fission cross sections of the Pu isotopes. For the case of capture on 242Pu, a reduction of the uncertainty in the fast region down to 8-12% is required. Moreover, aiming at improving the evaluation of the fast energy range in terms of average parameters, the OECD NEA High Priority Request List (HPRL) requests high-resolution capture measurements with improved accuracy below 2 keV. The current uncertainties also affect the thermal point, where previous experiments deviate from each other by 20%. A fruitful collaboration betwen JGU Mainz and HZ Dresden-Rossendorf within the EC CHANDA project resulted in a 242Pu sample consisting of a stack of seven fission-like targets making a total of 95(4) mg of 242Pu electrodeposited on thin (11.5 μm) aluminum backings. This contribution presents the results of a set of measurements of the 242Pu(n, γ) cross section from thermal to 500 keV combining different neutron beams and techniques. The thermal point was determined at the Budapest Research Reactor by means of Neutron Activation Analysis and Prompt Gamma Analysis, and the resolved (1 eV - 4 keV) and unresolved (1 - 500 keV) resonance regions were measured using a set of four Total Energy detectors at the CERN n_TOF-EAR1.
Setup for the measurement of the 235U(n,f) cross section relative to n-p scattering up to 1 GeV
(2020)
The neutron induced fission of 235U is extensively used as a reference for neutron fluence measurements in various applications, ranging from the investigation of the biological effectiveness of high energy neutrons, to the measurement of high energy neutron cross sections of relevance for accelerator driven nuclear systems. Despite its widespread use, no data exist on neutron induced fission of 235U above 200 MeV. The neutron facility n_TOF offers the possibility to improve the situation. The measurement of 235U(n,f) relative to the differential n-p scattering cross-section, was carried out in September 2018 with the aim of providing accurate and precise cross section data in the energy range from 10 MeV up to 1 GeV. In such measurements, Recoil Proton Telescopes (RPTs) are used to measure the neutron flux while the fission events are detected and counted with dedicated detectors. In this paper the measurement campaign and the experimental set-up are illustrated.
The experimental area 2 (EAR-2) at CERNs neutron time-of-flight facility (n_TOF), which is operational since 2014, is designed and built as a short-distance complement to the experimental area 1 (EAR-1). The Parallel Plate Avalanche Counter (PPAC) monitor experiment was performed to characterize the beam pro↓le and the shape of the neutron 'ux at EAR-2. The prompt γ-flash which is used for calibrating the time-of-flight at EAR-1 is not seen by PPAC at EAR-2, shedding light on the physical origin of this γ-flash.
Monte Carlo (MC) simulations are an essential tool to determine fundamental features of a neutron beam, such as the neutron flux or the γ-ray background, that sometimes can not be measured or at least not in every position or energy range. Until recently, the most widely used MC codes in this field had been MCNPX and FLUKA. However, the Geant4 toolkit has also become a competitive code for the transport of neutrons after the development of the native Geant4 format for neutron data libraries, G4NDL. In this context, we present the Geant4 simulations of the neutron spallation target of the n_TOF facility at CERN, done with version 10.1.1 of the toolkit. The first goal was the validation of the intra-nuclear cascade models implemented in the code using, as benchmark, the characteristics of the neutron beam measured at the first experimental area (EAR1), especially the neutron flux and energy distribution, and the time distribution of neutrons of equal kinetic energy, the so-called Resolution Function. The second goal was the development of a Monte Carlo tool aimed to provide useful calculations for both the analysis and planning of the upcoming measurements at the new experimental area (EAR2) of the facility.
Anorexia nervosa (AN) is a complex neuropsychiatric disorder presenting with dangerously low body weight, and a deep and persistent fear of gaining weight. To date, only one genome-wide significant locus associated with AN has been identified. We performed an exome-chip based genome-wide association studies (GWAS) in 2158 cases from nine populations of European origin and 15 485 ancestrally matched controls. Unlike previous studies, this GWAS also probed association in low-frequency and rare variants. Sixteen independent variants were taken forward for in silico and de novo replication (11 common and 5 rare). No findings reached genome-wide significance. Two notable common variants were identified: rs10791286, an intronic variant in OPCML (P=9.89 × 10−6), and rs7700147, an intergenic variant (P=2.93 × 10−5). No low-frequency variant associations were identified at genome-wide significance, although the study was well-powered to detect low-frequency variants with large effect sizes, suggesting that there may be no AN loci in this genomic search space with large effect sizes.
Multiplex families with a high prevalence of a psychiatric disorder are often examined to identify rare genetic variants with large effect sizes. In the present study, we analysed whether the risk for bipolar disorder (BD) in BD multiplex families is influenced by common genetic variants. Furthermore, we investigated whether this risk is conferred mainly by BD-specific risk variants or by variants also associated with the susceptibility to schizophrenia or major depression. In total, 395 individuals from 33 Andalusian BD multiplex families as well as 438 subjects from an independent, sporadic BD case-control cohort were analysed. Polygenic risk scores (PRS) for BD, schizophrenia, and major depression were calculated and compared between the cohorts. Both the familial BD cases and unaffected family members had significantly higher PRS for all three psychiatric disorders than the independent controls, suggesting a high baseline risk for several psychiatric disorders in the families. Moreover, familial BD cases showed significantly higher BD PRS than unaffected family members and sporadic BD cases. A plausible hypothesis is that, in multiplex families with a general increase in risk for psychiatric disease, BD development is attributable to a high burden of common variants that confer a specific risk for BD. The present analyses, therefore, demonstrated that common genetic risk variants for psychiatric disorders are likely to contribute to the high incidence of affective psychiatric disorders in the multiplex families. The PRS explained only part of the observed phenotypic variance and rare variants might have also contributed to disease development.
Multiplex families with a high prevalence of a psychiatric disorder are often examined to identify rare genetic variants with large effect sizes. In the present study, we analysed whether the risk for bipolar disorder (BD) in BD multiplex families is influenced by common genetic variants. Furthermore, we investigated whether this risk is conferred mainly by BD-specific risk variants or by variants also associated with the susceptibility to schizophrenia or major depression. In total, 395 individuals from 33 Andalusian BD multiplex families (166 BD, 78 major depressive disorder, 151 unaffected) as well as 438 subjects from an independent, BD case/control cohort (161 unrelated BD, 277 unrelated controls) were analysed. Polygenic risk scores (PRS) for BD, schizophrenia (SCZ), and major depression were calculated and compared between the cohorts. Both the familial BD cases and unaffected family members had higher PRS for all three psychiatric disorders than the independent controls, with BD and SCZ being significant after correction for multiple testing, suggesting a high baseline risk for several psychiatric disorders in the families. Moreover, familial BD cases showed significantly higher BD PRS than unaffected family members and unrelated BD cases. A plausible hypothesis is that, in multiplex families with a general increase in risk for psychiatric disease, BD development is attributable to a high burden of common variants that confer a specific risk for BD. The present analyses demonstrated that common genetic risk variants for psychiatric disorders are likely to contribute to the high incidence of affective psychiatric disorders in the multiplex families. However, the PRS explained only part of the observed phenotypic variance, and rare variants might have also contributed to disease development.
Background and Aim: Several studies observed alterations in the gut microbiota in patients with non‐alcoholic fatty liver disease (NAFLD). However, analyzed patient populations and methods strongly differ among these studies. The aim of this study was to prove the reproducibility of published results and to provide a detailed overview of all findings in our NAFLD cohort using next generation sequencing methods.
Methods: The individual taxonomic microbiota composition of fecal samples from 90 NAFLD patients and 21 healthy controls was analyzed using 16S rRNA gene sequencing. Study participants were grouped according to their disease stage and compared regarding their gut microbiota composition. Studies were identified from PubMed listed publications, and the results were compared with the findings in our cohort.
Results: Results from 13 identified studies were compared with our data. A decreased abundance of the Bacteroidetes and Ruminococcaceae as well as an increased abundance of Lactobacillaceae and Veillonellaceae and Dorea were the most frequently reported changes among NAFLD patients in 4/13, 5/13, 4/13, 2/13, and 3/13 studies, respectively. Even though these alterations in the gut microbiota composition were also observed in our patient cohort, the majority of published differences could not be reproduced, neither in our own nor in other NAFLD cohort studies.
Conclusion: Despite repeatedly reproduced abundance patterns of specific bacteria, the heterogeneous study results did not reveal a consistent disease specific gut microbiota signature. Further prospective studies with homogenous patient cohorts and standardized methods are necessary to phenotype NAFLD by the gut microbiota.
Hemispherical and cylindrical antenna arrays are widely used in radar-based and tomography-based microwave breast imaging systems. Based on the dielectric contrast between healthy and malignant tissue, a three-dimensional image could be formed to locate the tumor. However, conventional X-ray mammography as the golden standard in breast cancer screening produces two-dimensional breast images so that a comparison between the 3D microwave image and the 2D mammogram could be difficult. In this paper, we present the design and realisation of a UWB breast imaging prototype for the frequency band from 1 to 9 GHz. We present a refined system design in light of the clinical usage by means of a planar scanning and compare microwave images with those obtained by X-ray mammography. Microwave transmission measurements were processed to create a two-dimensional image of the breast that can be compared directly with a two-dimensional mammogram. Preliminary results from a patient study are presented and discussed showing the ability of the proposed system to locate the tumor.
Objective: To evaluate the efficacy and tolerability of brivaracetam (BRV) in a severely drug refractory cohort of patients with epileptic encephalopathies (EE).
Method: A multicenter, retrospective cohort study recruiting all patients treated with EE who began treatment with BRV in an enrolling epilepsy center between 2016 and 2017.
Results: Forty-four patients (27 male [61%], mean age 29 years, range 6 to 62) were treated with BRV. The retention rate was 65% at 3 months, 52% at 6 months and 41% at 12 months. A mean retention time of 5 months resulted in a cumulative exposure to BRV of 310 months. Three patients were seizure free during the baseline. At 3 months, 20 (45%, 20/44 as per intention-to-treat analysis considering all patients that started BRV including three who were seizure free during baseline) were either seizure free (n = 4; 9%, three of them already seizure-free at baseline) or reported at least 25% (n = 4; 9%) or 50% (n = 12; 27%) reduction in seizures. An increase in seizure frequency was reported in two (5%) patients, while there was no change in the seizure frequency of the other patients. A 50% long-term responder rate was apparent in 19 patients (43%), with two (5%) free from seizures for more than six months and in nine patients (20%, with one [2 %] free from seizures) for more than 12 months. Treatment-emergent adverse events were predominantly of psychobehavioural nature and were observed in 16%.
Significance: In this retrospective analysis the rate of patients with a 50% seizure reduction under BRV proofed to be similar to those seen in regulatory trials for focal epilepsies. BRV appears to be safe and relatively well tolerated in EE and might be considered in patients with psychobehavioral adverse events while on levetiracetam.
We present an estimation of the uptake coefficient (γ) and yield of nitryl chloride (ClNO2) (f) for the heterogeneous processing of dinitrogen pentoxide (N2O5) using simultaneous measurements of particle and trace gas composition at a semi-rural, non-coastal, mountain site in the summer of 2011. The yield of ClNO2 varied between (0.035 ± 0.027) and (1.38 ± 0.60) with a campaign average of (0.49 ± 0.35). The large variability in f reflects the highly variable chloride content of particles at the site. Uptake coefficients were also highly variable with minimum, maximum and average γ values of 0.004, 0.11 and 0.028 ± 0.029, respectively, with no significant correlation with particle composition, but a weak dependence on relative humidity. The uptake coefficients obtained are compared to existing parameterizations based on laboratory datasets and with other values obtained by analysis of field data.
We present an estimation of the uptake coefficient (γ) and yield of nitryl chloride (ClNO2) (f) for the heterogeneous processing of dinitrogen pentoxide (N2O5) using simultaneous measurements of particle and trace gas composition at a semi-rural, non-coastal, mountain site in the summer of 2011. The yield of ClNO2 varied between (0.035 ± 0.027) and (1.38 ± 0.60) with a campaign average of (0.49 ± 0.35). The large variability in f reflects the highly variable chloride content of particles at the site. Uptake coefficients were also highly variable with minimum, maximum and average γ values of 0.004, 0.11 and 0.028 ± 0.029, respectively, with no significant correlation with particle composition, but a weak dependence on relative humidity. The uptake coefficients obtained are compared to existing parameterisations based on laboratory datasets and with other values obtained by analysis of field data.
An important question concerning inter-areal communication in the cortex is whether these interactions are synergistic, i.e. brain signals can either share common information (redundancy) or they can encode complementary information that is only available when both signals are considered together (synergy). Here, we dissociated cortical interactions sharing common information from those encoding complementary information during prediction error processing. To this end, we computed co-information, an information-theoretical measure that distinguishes redundant from synergistic information among brain signals. We analyzed auditory and frontal electrocorticography (ECoG) signals in five common awake marmosets performing two distinct auditory oddball tasks and investigated to what extent event-related potentials (ERP) and broadband (BB) dynamics encoded redundant and synergistic information during auditory prediction error processing. In both tasks, we observed multiple patterns of synergy across the entire cortical hierarchy with distinct dynamics. The information conveyed by ERPs and BB signals was highly synergistic even at lower stages of the hierarchy in the auditory cortex, as well as between auditory and frontal regions. Using a brain-constrained neural network, we simulated the spatio-temporal patterns of synergy and redundancy observed in the experimental results and further demonstrated that the emergence of synergy between auditory and frontal regions requires the presence of strong, long-distance, feedback and feedforward connections. These results indicate that the distributed representations of prediction error signals across the cortical hierarchy can be highly synergistic.
Study Design: Survey of 100 worldwide spine surgeons.
Objective: To develop a spine injury score for the AOSpine Thoracolumbar Spine Injury Classification System.
Methods: Each respondent was asked to numerically grade the severity of each variable of the AOSpine Thoracolumbar Spine Injury Classification System. Using the results, as well as limited input from the AOSpine Trauma Knowledge Forum, the Thoracolumbar AOSpine Injury Score was developed.
Results: Beginning with 1 point for A1, groups A, B, and C were consecutively awarded an additional point (A1, 1 point; A2, 2 points; A3, 3 points); however, because of a significant increase in the severity between A3 and A4 and because the severity of A4 and B1 was similar, both A4 and B1 were awarded 5 points. An uneven stepwise increase in severity moving from N0 to N4, with a substantial increase in severity between N2 (nerve root injury with radicular symptoms) and N3 (incomplete spinal cord injury) injuries, was identified. Hence, each grade of neurologic injury was progressively given an additional point starting with 0 points for N0, and the substantial difference in severity between N2 and N3 injuries was recognized by elevating N3 to 4 points. Finally, 1 point was awarded to the M1 modifier (indeterminate posterolateral ligamentous complex injury).
Conclusion: The Thoracolumbar AOSpine Injury Score is an easy-to-use, data-driven metric that will allow for the development of a surgical algorithm to accompany the AOSpine Thoracolumbar Spine Injury Classification System.
Study Design: Cross-sectional survey
Objective: To determine the influence of surgeons’ level of experience and subspeciality training on the reliability, reproducibility, and accuracy of sacral fracture classification using the AO Spine Sacral Injury Classification System.
Summary of Background Data: An ideal classification system is easily comprehensible and reliable amongst the diverse group of surgeons. A surgeons’ level of experience may have a significant effect on the reliability and accuracy of a classification system. Moreover, surgeons of different subspecialities may have various levels of comfort with imaging assessment of sacral injuries required for accurate diagnosis and classification.
Methods: High-resolution computerized tomography (CT) images from 26 cases were assessed by 172 investigators from a diverse array of surgical subspecialities (general orthopaedics, neurosurgery, orthopaedic spine, orthopaedic trauma) and experience (<5, 5-10, 11-20, >20 years). Validation assessments were performed via web conference using high-resolution images, as well as axial/sagittal/coronal CT scan sequences. Two assessments were performed by each investigator independently three weeks apart in randomized order. Reliability and reproducibility were calculated with cohen’s kappa coefficient (k) and gold standard classification agreement was determined for each fracture morphology and subtype and stratified by experience and subspeciality.
Results: Respondents achieved an overall k = 0.87 for morphology and k = 0.77 for subtype classification, representing excellent and substantial intraobserver reproducibility, respectively. Respondents from all four practice experience groups demonstrated excellent interobserver reliability when classifying overall morphology (k=0.842/0.850, Assessment 1/Assessment 2) and substantial interobserver reliability in overall subtype (k=0.719/0.751) in both assessments. General orthopaedists, neurosurgeons, and orthopaedic spine surgeons exhibited excellent interobserver reliability in overall morphology classification and substantial interobserver reliability in overall subtype classification. Surgeons in each experience category and subspecialty correctly classified fracture morphology in over 90% of cases and fracture subtype in over 80% of cases according to the gold standard. Correct overall classification of fracture morphology (Assessment 1: p= 0.024, Assessment 2: p=0.006) and subtype (p2<0.001) differed significantly with surgeons with >20 years of experience demonstrating increased difficulty correctly classifying all fracture subtypes overall in comparison to the other experience groups. Correct overall classification did not significantly differ by subspecialty.
Conclusions: Overall, the AO Spine Sacral Injury Classification System appears to be universally applicable among surgeons of various subspecialties and levels of experience with acceptable reliability, reproducibility, and accuracy.
Disclosures: author 1: none; author 2: consultant=Medtronic, Nuvasive, ISD, Asutra, Stryker, Bioventus, Zimmer, teledocs, Clinical Spine Surgery, AOSpine ; author 3: none; author 4: grants/research support=AOSpine, consultant=DPS, icotec; author 5: none; author 6: none; author 7: grants/research support=DPS; author 8: none; author 9: grants/research support=NIH, RTI, CSRS, royalties=Inion ; author 10: stock/shareholder=Advanced Spinal Intellectual Properties; Atlas Spine; Avaz Surgical; Bonovo Orthopaedics; Computational Biodynamics; Cytonics; Deep Health; Dimension Orthotics LLC; Electrocore; Flagship Surgical; FlowPharma; Globus; Innovative Surgical Design; Insight Therapeutics; Jushi; Nuvasive; Orthobullets; Paradigm Spine; Parvizi Surgical Innovation; Progressive Spinal Technologies; Replication Medica; Spine Medica; Spineology; Stout Medical; Vertiflex; ViewFi Health, royalties=Aesculap; Atlas Spine; Globus; Medtronics; SpineWave; Stryker Spine,other financial report=AO Spine