Refine
Year of publication
Document Type
- Article (64)
- Part of a Book (7)
- Conference Proceeding (6)
- Preprint (2)
- Doctoral Thesis (1)
- Habilitation (1)
Language
- English (54)
- German (26)
- Multiple languages (1)
Has Fulltext
- yes (81)
Is part of the Bibliography
- no (81)
Keywords
- wassergefiltertes Infrarot A (wIRA) (25)
- Gewebetemperatur (21)
- Gewebedurchblutung (20)
- Wundheilung (20)
- Sauerstoffpartialdruck im Gewebe (19)
- Schmerzminderung (19)
- water-filtered infrared-A (wIRA) (18)
- Infektionsabwehr (16)
- reduction of pain (15)
- tissue oxygen partial pressure (15)
Institute
Anknüpfend an Untersuchungen von Nachwirkungserscheinungen vor allem an der Taenia coli des Meerschweinchens, bei denen Nachdehnung und Relaxation mit einer Hyperbelfunktion beschrieben wurden, gehörte es zu den Zielen dieser Arbeit, Gesetzmäßigkeiten im zeitlichen Verlauf der Nachdehnung bei dem anders strukturierten Uterushorn in verschiedenen Badlösungen zu untersuchen und insbesondere zu prüfen, ob die Hyperbelfunktion auch darauf angewendet werden kann und welche Rückschlüsse auf die funktionelle Struktur möglich sind.
Nach Voruntersuchungen an 30 Uterushörnern, bei denen auch Fragen der Tierwahl und der Standardisierung des Hormoneinflusses untersucht wurden, folgten nach ausführlicher biomathematischer Planung Hauptuntersuchungen an 58 Uterushörnern. Ein weiteres Ziel der Arbeit, eine wesentliche Verbesserung der Datenerfassung, konnte durch Einsatz eines Kurvenfolgers in Verbindung mit einer EDV-Anlage und eigenen Datenerfassungsprogrammen erreicht werden, wobei besonderer Wert darauf gelegt wurde, die Reproduzierbarkeit der Datenerfassung näher zu untersuchen, um die erzielte Genauigkeit, die höher als bei allen vergleichsweise zitierten Arbeiten liegt, nachprüfbarangeben zu können. Die erweiterten Möglichkeiten der Datenerfassung lieferten den Anstoß zum Erkennen von Problemen in der bisher üblichen Form der Datenauswertung, der Wertestandardisierung und der Nachdehnungsdefinition; hierfür konnten Lösungswege erarbeitet werden: u.a. ein EDV-Programm zur iterativen Hyperbelanpassung, Definition neuer Nachdehnungsgrößen und eine Aufgliederung in eine modellunabhängige und eine modellabhängige Auswertung.
Nach einem ausführlichen Überblick Uber die Physiologie glatter Muskulatur unter den Aspekten von Funktion und Struktur sowie einer Auseinandersetzung mit dem Begriff des Modells erfolgte eine zusammenfassende Datenauswertung: eine univariate Mehrwegkovarianzanalyse bestätigte nicht nur die Bedeutung des Faktors „Badlösung”, sondern ermöglichte auch unerwartete Aussagen über Kovariablen und Wechselwirkungen, die in früheren Arbeiten nicht in die Fragestellungen mit einbezogen worden waren; iterative Kurvenanpassungen zeigten die Überlegenheit mehrerer einfacher logarithmischer und exponentieller Funktionen im Vergleich zur Hyperbelfunktion. Außerdem waren Vergleiche zwischen verschieden strukturierten Muskeln und zwei Tierarten möglich.
Aus den gewonnenen Ergebnissen werden einige Schlußfolgerungen gezogen und Deutungen für die funktionelle Struktur des glatten Muskels gegeben.
Elliptic flow from nuclear collisions is a hadronic observable sensitive to the early stages of system evolution. We report first results on elliptic flow of charged particles at midrapidity in Au+Au collisions at sqrt(s_NN)=130 GeV using the STAR TPC at RHIC. The elliptic flow signal, v_2, averaged over transverse momentum, reaches values of about 6% for relatively peripheral collisions and decreases for the more central collisions. This can be interpreted as the observation of a higher degree of thermalization than at lower collision energies. Pseudorapidity and transverse momentum dependence of elliptic flow are also presented.
Two-pion correlation functions in Au+Au collisions at sqrt[sNN] = 130 GeV have been measured by the STAR (solenoidal tracker at RHIC) detector. The source size extracted by fitting the correlations grows with event multiplicity and decreases with transverse momentum. Anomalously large sizes or emission durations, which have been suggested as signals of quark-gluon plasma formation and rehadronization, are not observed. The Hanbury Brown-Twiss parameters display a weak energy dependence over a broad range in sqrt[sNN].
The first measurements of light antinucleus production in Au+Au collisions at the Relativistic Heavy-Ion Collider are reported. The observed production rates for d-bar and 3He-bar are much larger than in lower energy nucleus-nucleus collisions. A coalescence model analysis of the yields indicates that there is little or no increase in the antinucleon freeze-out volume compared to collisions at CERN SPS energy. These analyses also indicate that the 3He-bar freeze-out volume is smaller than the d-bar freeze-out volume.
Elliptic flow from nuclear collisions is a hadronic observable sensitive to the early stages of system evolution. We report first results on elliptic flow of charged particles at midrapidity in Au+Au collisions at sqrt[sNN] = 130 GeV using the STAR Time Projection Chamber at the Relativistic Heavy Ion Collider. The elliptic flow signal, v2, averaged over transverse momentum, reaches values of about 6% for relatively peripheral collisions and decreases for the more central collisions. This can be interpreted as the observation of a higher degree of thermalization than at lower collision energies. Pseudorapidity and transverse momentum dependence of elliptic flow are also presented.
The minimum-bias multiplicity distribution and the transverse momentum and pseudorapidity distributions for central collisions have been measured for negative hadrons ( h-) in Au+Au interactions at sqrt[sNN] = 130 GeV. The multiplicity density at midrapidity for the 5% most central interactions is dNh-/d eta | eta = 0 = 280±1(stat)±20(syst), an increase per participant of 38% relative to pp-bar collisions at the same energy. The mean transverse momentum is 0.508±0.012 GeV/c and is larger than in central Pb+Pb collisions at lower energies. The scaling of the h- yield per participant is a strong function of pperp. The pseudorapidity distribution is almost constant within | eta |<1.
We report the first measurement of inclusive antiproton production at midrapidity in Au+Au collisions at sqrt[sNN] = 130 GeV by the STAR experiment at RHIC. The antiproton transverse mass distributions in the measured transverse momentum range of 0.25<pperp<0.95 GeV/c are found to fall less steeply for more central collisions. The extrapolated antiproton rapidity density is found to scale approximately with the negative hadron multiplicity density.
We report results on the ratio of midrapidity antiproton-to-proton yields in Au+Au collisions at sqrt[sNN] = 130 GeV per nucleon pair as measured by the STAR experiment at RHIC. Within the rapidity and transverse momentum range of | y|<0.5 and 0.4<pt<1.0 GeV/c, the ratio is essentially independent of either transverse momentum or rapidity, with an average of 0.65±0.01(stat)±0.07(syst) for minimum bias collisions. Within errors, no strong centrality dependence is observed. The results indicate that at this RHIC energy, although the p-p-bar pair production becomes important at midrapidity, a significant excess of baryons over antibaryons is still present.
Elliptic flow holds much promise for studying the early-time thermalization attained in ultrarelativistic nuclear collisions. Flow measurements also provide a means of distinguishing between hydrodynamic models and calculations which approach the low density (dilute gas) limit. Among the effects that can complicate the interpretation of elliptic flow measurements are azimuthal correlations that are unrelated to the reaction plane (nonflow correlations). Using data for Au + Au collisions at sqrt[sNN]=130 GeV from the STAR time projection chamber, it is found that four-particle correlation analyses can reliably separate flow and nonflow correlation signals. The latter account for on average about 15% of the observed second-harmonic azimuthal correlation, with the largest relative contribution for the most peripheral and the most central collisions. The results are also corrected for the effect of flow variations within centrality bins. This effect is negligible for all but the most central bin, where the correction to the elliptic flow is about a factor of 2. A simple new method for two-particle flow analysis based on scalar products is described. An analysis based on the distribution of the magnitude of the flow vector is also described.
We report the first observation of K*(892)0--> pi K in relativistic heavy ion collisions. The transverse momentum spectrum of (K*0+K*0)/2 from central Au+Au collisions at sqrt[sNN]=130 GeV is presented. The ratios of the K*0 yield derived from these data to the yields of negative hadrons, charged kaons, and phi mesons have been measured in central and minimum bias collisions and compared with model predictions and comparable e+e-, pp, and p-barp results. The data indicate no dramatic reduction of K*0 production in relativistic heavy ion collisions despite expected losses due to rescattering effects.
The STAR Collaboration reports the first observation of exclusive rho 0 photoproduction, AuAu-->AuAu rho 0, and rho 0 production accompanied by mutual nuclear Coulomb excitation, AuAu-->Au [star] Au [star] rho 0, in ultraperipheral heavy-ion collisions. The rho 0 have low transverse momenta, consistent with coherent coupling to both nuclei. The cross sections at sqrt[sNN]=130 GeV agree with theoretical predictions treating rho 0 production and Coulomb excitation as independent processes.
We report STAR results on the azimuthal anisotropy parameter v2 for strange particles K0S, Lambda , and Lambda -bar at midrapidity in Au+Au collisions at sqrt[sNN]=130 GeV at the Relativistic Heavy Ion Collider. The value of v2 as a function of transverse momentum, pt, of the produced particle and collision centrality is presented for both particles up to pt~3.0 GeV/c. A strong pt dependence in v2 is observed up to 2.0 GeV/c. The v2 measurement is compared with hydrodynamic model calculations. The physics implications of the pt integrated v2 magnitude as a function of particle mass are also discussed.
Inclusive transverse momentum distributions of charged hadrons within 0.2<pT<6.0 GeV/c have been measured over a broad range of centrality for Au+Au collisions at sqrt[sNN]=130 GeV. Hadron yields are suppressed at high pT in central collisions relative to peripheral collisions and to a nucleon-nucleon reference scaled for collision geometry. Peripheral collisions are not suppressed relative to the nucleon-nucleon reference. The suppression varies continuously at intermediate centralities. The results indicate significant nuclear medium effects on high-pT hadron production in heavy-ion collisions at high energy.
We report the first measurement of strange ( Lambda ) and antistrange ( Lambda -bar) baryon production from sqrt[sNN]=130 GeV Au+Au collisions at the Relativistic Heavy Ion Collider (RHIC). Rapidity density and transverse mass distributions at midrapidity are presented as a function of centrality. The yield of Lambda and Lambda -bar hyperons is found to be approximately proportional to the number of negative hadrons. The production of Lambda -bar hyperons relative to negative hadrons increases very rapidly with transverse momentum. The magnitude of the increase cannot be described by existing hadronic string fragmentation models alone.
We present the first measurement of midrapidity vector meson phi production in Au+Au collisions at RHIC (sqrt[sNN]=130 GeV) from the STAR detector. For the 11% highest multiplicity collisions, the slope parameter from an exponential fit to the transverse mass distribution is T=379±50(stat)±45(syst) MeV, the yield dN/dy=5.73±0.37(stat)±0.69(syst) per event, and the ratio N phi /Nh- is found to be 0.021±0.001(stat)±0.004(syst). The measured ratio N phi /Nh- and T for the phi meson at midrapidity do not change for the selected multiplicity bins.
Pion-kaon correlation functions are constructed from central Au+Au STAR data taken at sqrt[sNN]=130 GeV by the STAR detector at the Relativistic Heavy Ion Collider (RHIC). The results suggest that pions and kaons are not emitted at the same average space-time point. Space-momentum correlations, i.e., transverse flow, lead to a space-time emission asymmetry of pions and kaons that is consistent with the data. This result provides new independent evidence that the system created at RHIC undergoes a collective transverse expansion.
Data from the first physics run at the Relativistic Heavy-Ion Collider at Brookhaven National Laboratory, Au+Au collisions at sqrt[sNN]=130 GeV, have been analyzed by the STAR Collaboration using three-pion correlations with charged pions to study whether pions are emitted independently at freeze-out. We have made a high-statistics measurement of the three-pion correlation function and calculated the normalized three-particle correlator to obtain a quantitative measurement of the degree of chaoticity of the pion source. It is found that the degree of chaoticity seems to increase with increasing particle multiplicity.
We report high statistics measurements of inclusive charged hadron production in Au+Au and p+p collisions at sqrt[sNN]=200 GeV. A large, approximately constant hadron suppression is observed in central Au+Au collisions for 5<pT<12 GeV/c. The collision energy dependence of the yields and the centrality and pT dependence of the suppression provide stringent constraints on theoretical models of suppression. Models incorporating initial-state gluon saturation or partonic energy loss in dense matter are largely consistent with observations. We observe no evidence of pT-dependent suppression, which may be expected from models incorporating jet attenuation in cold nuclear matter or scattering of fragmentation hadrons.
The balance function is a new observable based on the principle that charge is locally conserved when particles are pair produced. Balance functions have been measured for charged particle pairs and identified charged pion pairs in Au+Au collisions at sqrt[sNN]=130 GeV at the Relativistic Heavy Ion Collider using STAR. Balance functions for peripheral collisions have widths consistent with model predictions based on a superposition of nucleon-nucleon scattering. Widths in central collisions are smaller, consistent with trends predicted by models incorporating late hadronization.
We present the results of charged particle fluctuations measurements in Au+Au collisions at sqrt[sNN ]=130 GeV using the STAR detector. Dynamical fluctuations measurements are presented for inclusive charged particle multiplicities as well as for identified charged pions, kaons, and protons. The net charge dynamical fluctuations are found to be large and negative providing clear evidence that positive and negative charged particle production is correlated within the pseudorapidity range investigated. Correlations are smaller than expected based on model-dependent predictions for a resonance gas or a quark-gluon gas which undergoes fast hadronization and freeze-out. Qualitative agreement is found with comparable scaled p+p measurements and a heavy ion jet interaction generation model calculation based on independent particle collisions, although a small deviation from the 1/N scaling dependence expected from this model is observed.
We report measurements of single-particle inclusive spectra and two-particle azimuthal distributions of charged hadrons at high transverse momentum (high pT) in minimum bias and central d+Au collisions at sqrt[sNN]=200 GeV. The inclusive yield is enhanced in d+Au collisions relative to binary-scaled p+p collisions, while the two-particle azimuthal distributions are very similar to those observed in p+p collisions. These results demonstrate that the strong suppression of the inclusive yield and back-to-back correlations at high pT previously observed in central Au+Au collisions are due to final-state interactions with the dense medium generated in such collisions.
Azimuthal anisotropy (v2) and two-particle angular correlations of high pT charged hadrons have been measured in Au+Au collisions at sqrt[sNN]=130 GeV for transverse momenta up to 6 GeV/c, where hard processes are expected to contribute significantly. The two-particle angular correlations exhibit elliptic flow and a structure suggestive of fragmentation of high pT partons. The monotonic rise of v2(pT) for pT<2 GeV/c is consistent with collective hydrodynamical flow calculations. At pT>3 GeV/c, a saturation of v2 is observed which persists up to pT=6 GeV/c.
Azimuthal anisotropy (v2) and two-particle angular correlations of high pT charged hadrons have been measured in Au+Au collisions at sqrt[sNN]=130 GeV for transverse momenta up to 6 GeV/c, where hard processes are expected to contribute significantly. The two-particle angular correlations exhibit elliptic flow and a structure suggestive of fragmentation of high pT partons. The monotonic rise of v2(pT) for pT<2 GeV/c is consistent with collective hydrodynamical flow calculations. At pT>3 GeV/c, a saturation of v2 is observed which persists up to pT=6 GeV/c.
Einleitung Welche Methoden der Leistungssteigerung gibt es eigentlich im Sport? Von körperlicher Aktivität und Training (mit einer Fülle positiver Wirkungen) über Ernährung und Nahrungsergänzungsmittel bis zu unerlaubten Mitteln. Welche Methoden wirken? Was ist sinnvoll? Was ist erlaubt? Was ist überflüssig? Wo kann der einzelne mit seinen eigenen Erwartungshaltungen dazu beitragen, zum Beispiel unrealistischen Leistungsdruck gegenüber Sporttreibenden und damit eine potentielle Dopingproblematik im Ursprung zu vermeiden? Diese Fragen wollte die Veranstaltung „Leistungssteigerung im Sport - Ursachen, Methoden, Bewertungen, Lösungen“ des Arbeitskreises Sportmedizin der Akademie für ärztliche Fortbildung und Weiterbildung der Landesärztekammer Hessen (Prof. Dr. med. Gerd Hoffmann, Prof. Dr. med. Ingeborg Siegfried) und des Hessischen Ärzteblattes (Prof. Dr. med. Toni Graf-Baumann) in Zusammenarbeit mit der Sektion Breiten-, Freizeit- und Alterssport der Deutschen Gesellschaft für Sportmedizin und Prävention (DGSP), der Verbände mit besonderer Aufgabenstellung, Verbände für Wissenschaft und Bildung und Förderverbände (VmbAWBF) im Deutschen Sportbund (DSB) und dem FIFA Medical Assessment and Research Center (F-MARC) in einer bevölkerungsoffenen Informationsveranstaltung am 09.05.2003 und einer Fort- und Weiterbildungsveranstaltung am 10.05.2003 beantworten. Bericht über die Beiträge - Eröffnung - Ursachen für Leistungssteigerung im Sport und Lösungsansätze (Dr. med. Udo Schreiber) - Training, Übertraining, Regeneration, Rehabilitation - Grundsätzliche Überlegungen unter spezieller Berücksichtigung des Bewegungssystems (Dr. med. Udo Schreiber) - Training, Übertraining, Regeneration, Rehabilitation - sportmedizinisch-internistische Aspekte: Wirkung körperlicher Aktivität auf verschiedene Organsysteme (Prof. Dr. med. Gerd Hoffmann) - Muskulatur und Muskelphysiologie (Dr. med. Udo Schreiber) - Auswirkungen körperlicher Aktivität auf das Immunsystem (Prof. Dr. med. Reinhard Bretzel) - Sport trotz Medikamenten und Medikamente wegen Sport (Prof. Dr. med. Bernd Waldecker) - Ernährung und Sport einschließlich sportartspezifischer und trainingsphasenspezifischer Aspekte (Prof. Dr. med. Gerd Hoffmann) - Flüssigkeitssubstitution im Sport (Diplom-Oecotrophologin Dr. Annette Hauenschild) - Nahrungsergänzungsmittel zur Leistungssteigerung im Sport (Dr. med. Kurt-Reiner Geiß) - Leistungssteigernde Mittel und Methoden im Sport; Grenzen zur verbotenen Leistungssteigerung im Sport - Doping im Sport (Prof. Dr. med. Eide-Dittmar Lübs) - Ethische und rechtliche Aspekte verbotener Leistungssteigerung (Prof. Dr. med. Toni Graf-Baumann) - Brauchen wir leistungssteigernde Verfahren? Lösungsansätze (Dr. med. Dierk Heimann)
We report inclusive photon measurements about midrapidity ( |y| <0.5 ) from 197 Au + 197 Au collisions at sqrt[sNN ]=130 GeV at RHIC. Photon pair conversions were reconstructed from electron and positron tracks measured with the Time Projection Chamber (TPC) of the STAR experiment. With this method, an energy resolution of Delta E/E ~ 2% at 0.5 GeV has been achieved. Reconstructed photons have also been used to measure the transverse momentum ( pt ) spectra of pi 0 mesons about midrapidity ( |y| <1 ) via the pi 0 --> gamma gamma decay channel. The fractional contribution of the pi 0 --> gamma gamma decay to the inclusive photon spectrum decreases by 20%±5% between pt =1.65 GeV/c and pt =2.4 GeV/c in the most central events, indicating that relative to pi 0 --> gamma gamma decay the contribution of other photon sources is substantially increasing.
We report on the rapidity and centrality dependence of proton and antiproton transverse mass distributions from 197Au + 197Au collisions at sqrt[sNN ]=130 GeV as measured by the STAR experiment at the Relativistic Heavy Ion Collider (RHIC). Our results are from the rapidity and transverse momentum range of |y| <0.5 and 0.35< pt <1.00 GeV/c . For both protons and antiprotons, transverse mass distributions become more convex from peripheral to central collisions demonstrating characteristics of collective expansion. The measured rapidity distributions and the mean transverse momenta versus rapidity are flat within |y| <0.5 . Comparisons of our data with results from model calculations indicate that in order to obtain a consistent picture of the proton (antiproton) yields and transverse mass distributions the possibility of prehadronic collective expansion may have to be taken into account.
We present STAR measurements of the azimuthal anisotropy parameter v2 and the binary-collision scaled centrality ratio RCP for kaons and lambdas ( Lambda + Lambda -bar) at midrapidity in Au+Au collisions at sqrt[sNN]=200 GeV. In combination, the v2 and RCP particle-type dependencies contradict expectations from partonic energy loss followed by standard fragmentation in vacuum. We establish pT ~ 5 GeV/c as the value where the centrality dependent baryon enhancement ends. The K0S and Lambda + Lambda -bar v2 values are consistent with expectations of constituent-quark-number scaling from models of hadron formation by parton coalescence or recombination.
Transverse mass and rapidity distributions for charged pions, charged kaons, protons, and antiprotons are reported for sqrt[sNN]=200 GeV pp and Au+Au collisions at Relativistic Heary Ion Collider (RHIC). Chemical and kinetic equilibrium model fits to our data reveal strong radial flow and long duration from chemical to kinetic freeze-out in central Au+Au collisions. The chemical freeze-out temperature appears to be independent of initial conditions at RHIC energies.
Measurements of the production of forward high-energy pi 0 mesons from transversely polarized proton collisions at sqrt[s]=200 GeV are reported. The cross section is generally consistent with next-to-leading order perturbative QCD calculations. The analyzing power is small at xF below about 0.3, and becomes positive and large at higher xF, similar to the trend in data at sqrt[s] <= 20 GeV. The analyzing power is in qualitative agreement with perturbative QCD model expectations. This is the first significant spin result seen for particles produced with pT>1 GeV/c at a polarized proton collider.
We report results on rho (770)0--> pi + pi - production at midrapidity in p+p and peripheral Au+Au collisions at sqrt[sNN]=200 GeV. This is the first direct measurement of rho (770)0--> pi + pi - in heavy-ion collisions. The measured rho 0 peak in the invariant mass distribution is shifted by ~40 MeV/c2 in minimum bias p+p interactions and ~70 MeV/c2 in peripheral Au+Au collisions. The rho 0 mass shift is dependent on transverse momentum and multiplicity. The modification of the rho 0 meson mass, width, and shape due to phase space and dynamical effects are discussed.
We report the first observations of the first harmonic (directed flow, v1) and the fourth harmonic (v4), in the azimuthal distribution of particles with respect to the reaction plane in Au+Au collisions at the BNL Relativistic Heavy Ion Collider (RHIC). Both measurements were done taking advantage of the large elliptic flow (v2) generated at RHIC. From the correlation of v2 with v1 it is determined that v2 is positive, or in-plane. The integrated v4 is about a factor of 10 smaller than v2. For the sixth (v6) and eighth (v8) harmonics upper limits on the magnitudes are reported.
Azimuthally sensitive Hanbury Brown-Twiss interferometry in Au+Au collisions at sqrt[sNN]=200 GeV
(2004)
We present the results of a systematic study of the shape of the pion distribution in coordinate space at freeze-out in Au+Au collisions at BNL RHIC using two-pion Hanbury Brown-Twiss (HBT) interferometry. Oscillations of the extracted HBT radii versus emission angle indicate sources elongated perpendicular to the reaction plane. The results indicate that the pressure and expansion time of the collision system are not sufficient to completely quench its initial shape.
Background: Common warts (verrucae vulgares) are human papilloma virus (HPV) infections with a high incidence and prevalence, most often affecting hands and feet, being able to impair quality of life. About 30 different therapeutic regimens described in literature reveal a lack of a single striking strategy. Recent publications showed positive results of photodynamic therapy (PDT) with 5-aminolevulinic acid (5-ALA) in the treatment of HPV-induced skin diseases, especially warts, using visible light (VIS) to stimulate an absorption band of endogenously formed protoporphyrin IX. Additional experiences adding waterfiltered infrared A (wIRA) during 5-ALA-PDT revealed positive effects. Aim of the study: First prospective randomised controlled blind study including PDT and wIRA in the treatment of recalcitrant common hand and foot warts. Comparison of "5-ALA cream (ALA) vs. placebo cream (PLC)" and "irradiation with visible light and wIRA (VIS+wIRA) vs. irradiation with visible light alone (VIS)". Methods: Pre-treatment with keratolysis (salicylic acid) and curettage. PDT treatment: topical application of 5-ALA (Medac) in "unguentum emulsificans aquosum" vs. placebo; irradiation: combination of VIS and a large amount of wIRA (Hydrosun® radiator type 501, 4 mm water cuvette, waterfiltered spectrum 590-1400 nm, contact-free, typically painless) vs. VIS alone. Post-treatment with retinoic acid ointment. One to three therapy cycles every 3 weeks. Main variable of interest: "Percent change of total wart area of each patient over the time" (18 weeks). Global judgement by patient and by physician and subjective rating of feeling/pain (visual analogue scales). 80 patients with therapy-resistant common hand and foot warts were assigned randomly into one of the four therapy groups with comparable numbers of warts at comparable sites in all groups. Results: The individual total wart area decreased during 18 weeks in group 1 (ALA+VIS+wIRA) and in group 2 (PLC+VIS+wIRA) significantly more than in both groups without wIRA (group 3 (ALA+VIS) and 4 (PLC+VIS)): medians and interquartile ranges: -94% (-100%/-84%) vs. -99% (-100%/-71%) vs. -47% (-75%/0%) vs. -73% (-92%/-27%). After 18 weeks the two groups with wIRA differed remarkably from the two groups without wIRA: 42% vs. 7% completely cured patients; 72% vs. 34% vanished warts. Global judgement by patient and by physician and subjective rating of feeling was much better in the two groups with wIRA than in the two groups without wIRA. Conclusions: The above described complete treatment scheme of hand and foot warts (keratolysis, curettage, PDT treatment, irradiation with VIS+wIRA, retinoic acid ointment; three therapy cycles every 3 weeks) proved to be effective. Within this treatment scheme wIRA as non-invasive and painless treatment modality revealed to be an important, effective factor, while photodynamic therapy with 5-ALA in the described form did not contribute recognisably - neither alone (without wIRA) nor in combination with wIRA - to a clinical improvement. For future treatment of warts an even improved scheme is proposed: one treatment cycle (keratolysis, curettage, wIRA, without PDT) once a week for six to nine weeks. © 2004 Fuchs et al; licensee German Medical Science. This is an Open Access article: verbatim copying and redistribution of this article are permitted in all media for any purpose, provided this notice is preserved along with the article's original URL : http://www.egms.de/en/gms/volume2.shtml
We present the first large-acceptance measurement of event-wise mean transverse momentum <pt> fluctuations for Au-Au collisions at nucleon-nucleon center-of-momentum collision energy sqrt[sNN] = 130 GeV. The observed nonstatistical <pt> fluctuations substantially exceed in magnitude fluctuations expected from the finite number of particles produced in a typical collision. The r.m.s. fractional width excess of the event-wise <pt> distribution is 13.7±0.1(stat) ±1.3(syst)% relative to a statistical reference, for the 15% most-central collisions and for charged hadrons within pseudorapidity range | eta |<1,2 pi azimuth, and 0.15 <= pt <= 2 GeV/c. The width excess varies smoothly but nonmonotonically with collision centrality and does not display rapid changes with centrality which might indicate the presence of critical fluctuations. The reported <pt> fluctuation excess is qualitatively larger than those observed at lower energies and differs markedly from theoretical expectations. Contributions to <pt> fluctuations from semihard parton scattering in the initial state and dissipation in the bulk colored medium are discussed.
Apparent contradiction between negative effects of UV radiation and positive effects of sun exposure
(2005)
We would like to comment on the three contributions in the Journal of the National Cancer Institute, Vol. 97, No. 3, February 2, 2005: Kathleen M. Egan, Jeffrey A. Sosman, William J. Blot: Editorial: Sunlight and Reduced Risk of Cancer: Is the Real Story Vitamin D? (pp. 161-163) ; Marianne Berwick, Bruce K. Armstrong, Leah Ben-Porat, Judith Fine, Anne Kricker, Carey Eberle, Raymond Barnhill: Sun Exposure and Mortality From Melanoma. (pp. 195-199) ; Karin Ekström Smedby, Henrik Hjalgrim, Mads Melbye, Anna Torrång, Klaus Rostgaard, Lars Munksgaard, et al.: Ultraviolet Radiation Exposure and Risk of Malignant Lymphomas. (pp. 199-209).
Ziel des Seminars war es, für die "Volkskrankheit Rückenschmerz" vom sportorthopädisch-traumatologisch-sportmedizinischen, vom internistischen, vom schmerztherapeutisch-neurochirurgischen und vom physiotherapeutischen Standpunkt aus neue, auf physiologisch-pathophysiologischen Kenntnissen basierende Sichtweisen mit Relevanz für Prävention und Therapie des verbreiteten Problems Rückenschmerz zu präsentieren.
Der Rückenschmerz als Folge der biomechanischen Besonderheit des "Zweibeiners" im Zeitalter der Hypomobilisation und Hyperalimentation - Lendenwirbelsäulen- und Halswirbelsäulen-Beschwerden (Dr. med. Udo Schreiber, Frankfurt am Main): Der Rückenschmerz - besonders der tiefe Rückenschmerz - des Menschen ist wahrscheinlich meist durch eine Fehlstatik verursacht. In Deutschland beträgt die Inzidenz von Rückenschmerzen während des Lebens fast 80%. Dr. Schreiber legte dar, dass die anatomische Längendifferenz der Beine zu verschiedenen Pathologien im Halte- und Bewegungsapparat führt. Die pathologischen Veränderungen - z.B. transversaler Schub auf das Ileosakralgelenk - treten meistens auf der längeren Beinseite mit einer Skoliose der Wirbelsäule mit erhöhten Druckbelastungen auf der Konkavseite der Skoliose in den Bandscheiben und mit typischen Blockaden in den verschiedenen Wirbelsäulensegmenten auf. Sinnvolle Diagnostik beinhaltet Anamnese und umfangreiche klinische Untersuchung zum Erkennen von Funktionsdefiziten anstelle von nur bildgebender Diagnostik. Sinnvolle Therapien sind - neben analgetischen Therapien, wie manueller Therapie, Matrix-Rhythmus-Therapie, wassergefiltertem Infrarot A (wIRA), Ohrakupunktur, Magnetfeldresonanztherapie, Mikrostromtherapie, Injektionstherapie - vor allem die therapeutisch-präventiven Maßnahmen Dehnen verkürzter Muskulatur und partieller Ausgleich von Beinlängendifferenzen. Wirtschaftlich gesehen verursacht die Fehlstatik immense indirekte und direkte Krankheitskosten, wobei die aufgezeigten sinnvollen Therapien zielführend und zugleich kostengünstig sind.
Ein ganzheitliches Therapiekonzept mit Matrix-Rhythmus-Therapie, Hyperthermie, Sauerstoff und Entsäuerung - Therapie von muskulo-skelettalen Beschwerden (Dr. med. Bernhard Dickreiter, Nordrach): Die Kosten zur Behandlung von Rückenschmerzen belasten in den vergangenen Jahren zunehmend die Krankenkassen durch Diagnose- und Therapiekosten sowie die Betriebe durch Ausfallzeiten. Rückenschulkonzepte der vergangenen Jahre zeigen aus Sicht von Dr. Dickreiter nicht den gewünschten Effekt. Vielversprechende neue Sichtweisen für den Umgang mit diesem Krankheitsbild ergeben sich aus den aktuellen Ergebnissen der zellbiologischen Grundlagenforschungen und dem daraus resultierenden neuen "Matrix-Therapie-Konzept": Die Ursache der muskulo-skelettalen Beschwerden im Sinne eines myofaszialen, myo-ischämisch-azidotischen und myotendinitischen Schmerzsyndroms wird in der Verspannung der Muskulatur mit einer Energiekrise auf zellulärer Ebene gesehen. Beim neuen Therapiekonzept steht nicht eine Therapiefülle wie bisher im Vordergrund, sondern ein auf Effektivität ausgerichtetes modulares Konzept, welches die zellbiologischen Prozesse auf extrazellulärer Matrixebene gezielt beeinflusst. Wesentliche Bestandteile des Konzepts sind die Matrix-Rhythmus-Therapie als tiefenwirksame Mikroextensionstechnik, die lokale Wärme mit wassergefiltertem Infrarot A (wIRA) bzw. die Infrarot-Ganzkörperhyperthermie, die körperliche Bewegung zur lokalen Verbesserung der Sauerstoffversorgung, die Sauerstofftherapie einschließlich Hyperbarer Oxygenation (HBO) und die orthomolekulare Substitution und "gesunde" Ernährung.
Konservative, interventionelle und operative Verfahren aus der Sicht des Schmerztherapeuten und Neurochirurgen: Stellenwert im Hinblick auf ein integriertes Behandlungskonzept (Dr. med. Volker Ritzel, Offenbach am Main): Mit einem interdisziplinären Therapiekonzept (Hausarzt; Orthopädie, Neurochirurgie, Schmerztherapie, Krankengymnastik/Physiotherapie, Psychotherapie) multimodal mit Nutzung konservativer, interventioneller und operativer Verfahren können heute Rückenschmerzen erfolgreich behandelt werden. Dabei ist besonders auf eine rechtzeitige suffiziente Therapie Wert zu legen (u.a. protektive, antizipierende Analgesie), um die Ausbildung eines Schmerzgedächtnisses mit Chronifizierung und Verselbstständigung des Schmerzes zu vermeiden. Zu den konservativen Therapiemöglichkeiten gehören neben einer medikamentösen Schmerztherapie nach dem WHO-Stufenschema die Transkutane elektrische Nervenstimulation (TENS), Physiotherapie, Psychotherapie, übende Verfahren (Progressive Muskelentspannung nach Jakobsen, Autogenes Training, Göttinger Rücken-Aktiv-Programm GRAP), Ergotherapie, Akupunktur und Balneotherapie. Weitere schmerztherapeutisch-neurochirurgische Verfahren sind die therapeutische Lokalanästhesie, CT-gesteuerte Verfahren, die perkutane Laser-Diskus-Dekompression, denervierende Verfahren, die endoskopische Sequestrektomie, die Vertebroplastie, offen-operative Verfahren, die mikrochirurgische Dekompression sowie Implantatverfahren wie die minimal-invasive zervikale und lumbale Spondylodese. Ambulante/Praxisklinische Operationen können heute in einer neurochirurgischen Praxisklinik im Rahmen des modernen Konzepts der Integrationsversorgung erfolgen.
Rückenschule zur primären, sekundären und tertiären Prävention - Lebensstiländerung, Krankengymnastik/Physiotherapie - im Zeitalter integrierter ambulanter Versorgung (Monika Kremer, Frankfurt am Main): Moderne Therapiestrategien bevorzugen - soweit möglich - ein konservatives gegenüber einem operativen Vorgehen, ein aktives gegenüber einem passiven, ein multimodales gegenüber einem monotherapeutischen Vorgehen. Bewegungs- und trainingstherapeutische Maßnahmen (z.B. Erweiterte Ambulante Physiotherapie EAP als Komplextherapie mit den Bestandteilen Krankengymnastik/Physiotherapie, Physikalische Therapie und Medizinische Trainingstherapie MTT) sind wichtige Bestandteile moderner Rückenkonzepte. Die Arbeitsplatzsituation wird besonders berücksichtigt mit zunehmender Integration von Ergonomie-Trainingsprogrammen. Der Begriff "Präventive Rückenschule" umfasst die Vermittlung und Anwendung wirkungsvoller Alltagsstrategien zur Vermeidung hoher Rückenbelastungen, um der Entwicklung funktioneller und degenerativer Krankheiten vornehmlich im Bereich der Wirbelsäule einschließlich muskulärer Dysbalancen vorzubeugen. Hierzu gehört ein rückengerechtes Alltagsverhalten (z.B. richtiges körpernahes Heben und Tragen). Besonders effektiv sind aktive Trainingsformen zum Muskelaufbau und zur Verbesserung der Ausdauer in Kombination mit verhaltensorientierten Trainingsprogrammen mit dem Ziel der Steigerung von Wohlbefinden und Lebensqualität. Erläutert werden das Konzept des Forschungs- und Präventionszentrums Köln (FPZ), das Kieser-Training, das Baunataler Rücken-Konzept (BRK) und das tergumed®-Rückenkonzept. Häufig können Rückenschmerzen durch rückengerechte Verhaltensweisen sowie präventives und rehabilitatives Rückentraining vermieden werden oder es kann nach ihrem Auftreten rehabilitativ wieder ein schmerzfreier stabiler Gesundheitszustand erreicht werden.
Aim of the study: Investigation, whether water-filtered infrared-A (wIRA) irradiation during moderate bicycle ergometer endurance exercise has effects especially on local fat reduction and on weight reduction beyond the effects of ergometer exercise alone.
Methods: Randomised controlled study with 40 obese females (BMI 30-40 (median: 34.5), body weight 76-125 (median: 94.9) kg, age 20-40 (median: 35.5) years, isocaloric nutrition), 20 in the wIRA group and 20 in the control group. In both groups each participant performed 3 times per week over 4 weeks for 45 minutes bicycle ergometer endurance exercise with a constant load according to a lactate level of 2 mmol/l (aerobic endurance load, as determined before the intervention period). In the wIRA group in addition large parts of the body (including waist, hip, and thighs) were irradiated during all ergometries of the intervention period with visible light and a predominant part of water-filtered infrared-A (wIRA), using the irradiation unit “Hydrosun® 6000” with 10 wIRA radiators (Hydrosun® Medizintechnik, Müllheim, Germany, radiator type 500, 4 mm water cuvette, yellow filter, water-filtered spectrum 500-1400 nm) around a speed independent bicycle ergometer.
Main variable of interest: change of “the sum of circumferences of waist, hip, and both thighs of each patient” over the intervention period (4 weeks). Additional variables of interest: body weight, body mass index BMI, body fat percentage, fat mass, fat-free mass, water mass (analysis of body composition by tetrapolar bioimpedance analysis), assessment of an arteriosclerotic risk profile by blood investigation of variables of lipid metabolism (cholesterol, triglycerides, high density lipoproteins HDL, low density lipoproteins LDL, apolipoprotein A1, apolipoprotein B), clinical chemistry (fasting glucose, alanin-aminotransferase ALT (= glutamyl pyruvic transaminase GPT), gamma-glutamyl-transferase GGT, creatinine, albumin), endocrinology (leptin, adiponectin (= adipo Q), homocysteine, insulin). All variables were at least measured before and after the intervention period. Ergometry (ECG, blood pressure behaviour, lactate curve with power at 2, 3 and 4 mmol/l) before the intervention period. In addition: nutrition training ahead of and during the intervention period with a nutrition protocol over one week for assessment of the daily energy intake; calculation of basic metabolic rate and total energy requirement. Assessment of undesired effects.
Only methods of non-parametric statistics were used, both descriptive (median, percentiles of 25 and 75 (= interquartile range), minimum, maximum) and confirmatory (two-sided Mann-Whitney U test for unpaired samples for the only one main variable of interest). Total error probability: .05 (5%). An intention to treat analysis ITT with last observed carry forward method was used preferably (presented results) and in addition an on treatment analysis OT. Only 2 (treatment group) and 4 (control group) drop-outs occurred (mostly due to lack of time).
Results: The “sum of circumferences of waist, hip, and both thighs of each patient” decreased during the 4 weeks significantly more (p<.001) in the wIRA group than in the control group: medians and interquartile ranges: -8.0 cm (-10.5 cm/-4.1 cm) vs. -1.8 cm (-4.4 cm/0.0 cm).
As well “body weight of each patient” decreased during the 4 weeks markedly more in the wIRA group than in the control group: medians and interquartile ranges: -1.9 kg (-4.0 kg/0.0 kg) vs. 0.0 kg (-1.5 kg/+0.4 kg); median of body weight changed from 99.3 kg to 95.6 kg (wIRA) vs. 89.9 kg to 89.6 kg (control). A similar effect showed the body mass index BMI.
Blood variables of interest remained unchanged or showed some slight improvements during the treatment period, concerning most variables with no obvious differences between the two groups; insulin showed a slight trend to decrease in the wIRA group and to increase in the control group.
Undesired effects of the treatment were not seen.
Discussion: The results of the study suggest, that wIRA – during moderate bicycle ergometer endurance exercise as lipolytic stimulus – increases local lipolysis with a local fat reduction (thighs) in the otherwise bradytrophic fatty tissue. The presumably underlying mechanisms of wIRA have already been proven: wIRA acts both by thermal effects and by non-thermal effects. Thermal effects of wIRA are the generation of a therapeutic field of warmth with the increase of tissue temperature, tissue oxygen partial pressure, and tissue blood flow, and by this regional metabolism. As fatty tissue normally has a slow metabolism (bradytrophic and hypothermic tissue) with a low rate of lipolysis, wIRA can increase lipolysis in fatty tissue and the mobilized fats are burned in musculature during the ergometer exercise.
Conclusion: The results of the study indicate, that wIRA irradiation during moderate ergometer endurance exercise can be used – in combination with an appropriate nutrition – to improve body composition, especially local fat distribution, and the reduction of fat and body weight in obese persons.
Keywords: water-filtered infrared-A (wIRA), weight reduction, local fat reduction, bicycle ergometer endurance exercise, lipolysis, randomised controlled study, intervention trial, body weight, body mass index BMI, analysis of body composition, tetrapolar bioimpedance analysis, lactate, lipid metabolism, cholesterol, triglycerides, high density lipoproteins HDL, low density lipoproteins LDL
Wassergefiltertes Infrarot A (wIRA) als spezielle Form der Wärmestrahlung mit hohem Penetrationsvermögen in das Gewebe bei geringer thermischer Oberflächenbelastung vermag über thermische und nicht-thermische Effekte wesentliche, auch energetisch bedeutsame Faktoren der Wundheilung - messtechnisch belegt - zu verbessern.
wIRA kann sowohl bei akuten Wunden (prospektive, randomisierte, kontrollierte, doppeltblinde Studien der chirurgischen Universitätsklinik Heidelberg bei frischen abdominellen Op-Wunden, n=94, und der Kinderchirurgie Kassel bei schwerbrandverletzten Kindern, n=45) als auch bei chronischen Wunden und Problemwunden (prospektive, randomisierte, kontrollierte Studie in Basel, n=40, sowie prospektive Studie der Universität Tromsø/Norwegen in Hillerød/Dänemark mit u. a. auch aufwendiger thermographischer Verlaufskontrolle, n=10, in beiden Studien chronische venöse Unterschenkel-Ulzera) einschließlich infizierter Wunden Schmerzen deutlich mindern und die Wundheilung beschleunigen oder bei stagnierender Wundheilung verbessern sowie eine erhöhte Wundsekretion und Entzündung mindern. Insbesondere ist auch ohne Wundheilungsstörung eine positive Beeinflussung der Wundheilung möglich. Bei chronischen Wunden werden vollständige Abheilungen erreicht, die zuvor nicht erreicht wurden.
wIRA ist ein kontaktfreies, verbrauchsmaterialfreies, leicht anzuwendendes, als angenehm empfundenes Verfahren mit guter Tiefenwirkung, das der Sonnenwärmestrahlung auf der Erdoberfläche in gemäßigten Klimazonen nachempfunden ist. Die Bestrahlung der unbedeckten Wunde erfolgt typischerweise aus ca. 25 cm Abstand mit einem wIRA-Strahler.
Wundheilung und Infektionsabwehr (z.B. Granulozytenfunktion einschließlich antibakterieller Sauerstoffradikalbildung der Granulozyten) hängen ganz entscheidend von einer ausreichenden Energieversorgung (und von ausreichend Sauerstoff) ab.
Die klinisch gute Wirkung von wIRA auf Wunden und auch auf Problemwunden und Wundinfektionen lässt sich u. a. über die Verbesserung sowohl der Energiebereitstellung pro Zeit (Steigerung der Stoffwechselleistung) als auch der Sauerstoffversorgung (z.B. für die Granulozytenfunktion) erklären. wIRA bewirkt als thermischen Effekt eine Verbesserung aller drei entscheidender Faktoren Sauerstoffpartialdruck im Gewebe, Gewebetemperatur und Gewebedurchblutung. Daneben wurden auch nicht-thermische Effekte von Infrarot A im Sinne einer Reizsetzung auf Zellen und zelluläre Strukturen mit Reaktionen der Zellen beschrieben.
Die infizierte Problemwunde
(2006)
Die erste Ausgabe der Online-Zeitschrift "GMS Krankenhaushygiene Interdisziplinär" der Deutschen Gesellschaft für Krankenhaushygiene (DGKH) innerhalb von German Medical Science behandelt das Thema "Die infizierte Problemwunde". Die Zielsetzung dieser Zeitschrift besteht in der komplexen Darstellung aktueller Themen der Krankenhaushygiene in interdisziplinärer Zusammenarbeit zwischen Hygienikern, Mikrobiologen, Infektiologen und für die jeweilige Thematik relevanten klinischen Fachdisziplinen und ggf. auch mit Experten anderer Fachrichtungen, z.B. Juristen, da rechtliche Aspekte zunehmend Bedeutung erlangen. ...
Aim of the study: Investigation, whether water-filtered infrared-A (wIRA) irradiation during moderate bicycle ergometer endurance exercise has effects especially on local fat reduction and on weight reduction beyond the effects of ergometer exercise alone.
Methods: Randomised controlled study with 40 obese females (BMI 30-40 (median: 34.5), body weight 76-125 (median: 94.9) kg, age 20-40 (median: 35.5) years, isocaloric nutrition), 20 in the wIRA group and 20 in the control group. In both groups each participant performed 3 times per week over 4 weeks for 45 minutes bicycle ergometer endurance exercise with a constant load according to a lactate level of 2 mmol/l (aerobic endurance load, as determined before the intervention period). In the wIRA group in addition large parts of the body (including waist, hip, and thighs) were irradiated during all ergometries of the intervention period with visible light and a predominant part of water-filtered infrared-A (wIRA), using the irradiation unit “Hydrosun® 6000” with 10 wIRA radiators (Hydrosun® Medizintechnik, Müllheim, Germany, radiator type 500, 4 mm water cuvette, yellow filter, water-filtered spectrum 500-1400 nm) around a speed independent bicycle ergometer.
Main variable of interest: change of “the sum of circumferences of waist, hip, and both thighs of each patient” over the intervention period (4 weeks). Additional variables of interest: body weight, body mass index BMI, body fat percentage, fat mass, fat-free mass, water mass (analysis of body composition by tetrapolar bioimpedance analysis), assessment of an arteriosclerotic risk profile by blood investigation of variables of lipid metabolism (cholesterol, triglycerides, high density lipoproteins HDL, low density lipoproteins LDL, apolipoprotein A1, apolipoprotein B), clinical chemistry (fasting glucose, alanin-aminotransferase ALT (= glutamyl pyruvic transaminase GPT), gamma-glutamyl-transferase GGT, creatinine, albumin), endocrinology (leptin, adiponectin (= adipo Q), homocysteine, insulin). All variables were at least measured before and after the intervention period. Ergometry (ECG, blood pressure behaviour, lactate curve with power at 2, 3 and 4 mmol/l) before the intervention period. In addition: nutrition training ahead of and during the intervention period with a nutrition protocol over one week for assessment of the daily energy intake; calculation of basic metabolic rate and total energy requirement. Assessment of undesired effects.
Only methods of non-parametric statistics were used, both descriptive (median, percentiles of 25 and 75 (= interquartile range), minimum, maximum) and confirmatory (two-sided Mann-Whitney U test for unpaired samples for the only one main variable of interest). Total error probability: .05 (5%). An intention to treat analysis ITT with last observed carry forward method was used preferably (presented results) and in addition an on treatment analysis OT. Only 2 (treatment group) and 4 (control group) drop-outs occurred (mostly due to lack of time).
Results: The “sum of circumferences of waist, hip, and both thighs of each patient” decreased during the 4 weeks significantly more (p<.001) in the wIRA group than in the control group: medians and interquartile ranges: -8.0 cm (-10.5 cm/-4.1 cm) vs. -1.8 cm (-4.4 cm/0.0 cm).
As well “body weight of each patient” decreased during the 4 weeks markedly more in the wIRA group than in the control group: medians and interquartile ranges: -1.9 kg (-4.0 kg/0.0 kg) vs. 0.0 kg (-1.5 kg/+0.4 kg); median of body weight changed from 99.3 kg to 95.6 kg (wIRA) vs. 89.9 kg to 89.6 kg (control). A similar effect showed the body mass index BMI.
Blood variables of interest remained unchanged or showed some slight improvements during the treatment period, concerning most variables with no obvious differences between the two groups; insulin showed a slight trend to decrease in the wIRA group and to increase in the control group.
Undesired effects of the treatment were not seen.
Discussion: The results of the study suggest, that wIRA – during moderate bicycle ergometer endurance exercise as lipolytic stimulus – increases local lipolysis with a local fat reduction (thighs) in the otherwise bradytrophic fatty tissue. The presumably underlying mechanisms of wIRA have already been proven: wIRA acts both by thermal effects and by non-thermal effects. Thermal effects of wIRA are the generation of a therapeutic field of warmth with the increase of tissue temperature, tissue oxygen partial pressure, and tissue blood flow, and by this regional metabolism. As fatty tissue normally has a slow metabolism (bradytrophic and hypothermic tissue) with a low rate of lipolysis, wIRA can increase lipolysis in fatty tissue and the mobilized fats are burned in musculature during the ergometer exercise.
Conclusion: The results of the study indicate, that wIRA irradiation during moderate ergometer endurance exercise can be used – in combination with an appropriate nutrition – to improve body composition, especially local fat distribution, and the reduction of fat and body weight in obese persons.
The central portion of chronic wounds is often hypoxic and relatively hypothermic, representing a deficient energy supply of the tissue, which impedes wound healing or even makes it impossible. Water-filtered infrared-A (wIRA) is a special form of heat radiation with a high tissue penetration and a low thermal load to the skin surface. wIRA produces a therapeutically usable field of heat and increases temperature, oxygen partial pressure and perfusion of the tissue. These three factors are decisive for a sufficient tissue supply with energy and oxygen and consequently as well for wound healing, especially in chronic wounds, and infection defense. wIRA acts both by thermal and thermic as well as by non-thermal and non-thermic effects. wIRA can advance wound healing or improve an impaired wound healing process and can especially enable wound healing in non-healing chronic wounds. wIRA can considerably alleviate the pain and diminish wound exudation and inflammation and can show positive immunomodulatory effects.
In a prospective, randomized, controlled study of 40 patients with chronic venous stasis ulcers of the lower legs irradiation with wIRA and visible light (VIS) accelerated the wound healing process (on average 18 vs. 42 days until complete wound closure, residual ulcer area after 42 days 0.4 cm² vs. 2.8 cm²) and led to a reduction of the required dose of pain medication in comparison to the control group of patients treated with the same standard care (wound cleansing, wound dressing with antibacterial gauze, and compression garment therapy) without the concomitant irradiation.
Another prospective study of 10 patients with non-healing chronic venous stasis ulcers of the lower legs included extensive thermographic investigation. Therapy with wIRA(+VIS) resulted in a complete or almost complete wound healing in 7 patients and a marked reduction of the ulcer size in another 2 of the 10 patients, a clear reduction of pain and required dose of pain medication, and a normalization of the thermographic image.
In a current prospective, randomized, controlled, blinded study patients with non-healing chronic venous stasis ulcers of the lower legs are treated with compression garment therapy, wound cleansing, wound dressings and 30 minutes irradiation five times per week over 9 weeks. A preliminary analysis of the first 23 patients of this study has shown in the group with wIRA(+VIS) compared to a control group with VIS an advanced wound healing, an improved granulation and in the later phase of treatment a decrease of the bacterial burden.
Some case reports have demonstrated that wIRA can also be used for mixed arterial-venous ulcers or arterial ulcers, if irradiation intensity is chosen appropriately low and if irradiation is monitored carefully. wIRA can be used concerning decubital ulcers both in a preventive and in a therapeutic indication. wIRA can improve the resorption of topically applied substances also on wounds.
An irradiation with VIS and wIRA presumably acts with endogenous protoporphyrin IX (or protoporphyrin IX of bacteria) virtually similar as a mild photodynamic therapy (endogenous PDT-like effect). This could lead to improved cell regeneration and wound healing and to antibacterial effects.
In conclusion, these results indicate that wIRA generally should be considered for the treatment of chronic wounds.
Water-filtered infrared-A (wIRA) as a special form of heat radiation with a high tissue penetration and with a low thermal load to the skin surface acts both by thermal and thermic as well as by non-thermal and non-thermic effects. wIRA produces a therapeutically usable field of heat in the tissue and increases tissue temperature, tissue oxygen partial pressure, and tissue perfusion. These three factors are decisive for a sufficient tissue supply with energy and oxygen and consequently as well for wound healing and infection defense.
wIRA can considerably alleviate the pain (with remarkably less need for analgesics) and diminish an elevated wound exudation and inflammation and can show positive immunomodulatory effects. wIRA can advance wound healing or improve an impaired wound healing both in acute and in chronic wounds including infected wounds. Even the normal wound healing process can be improved.
A prospective, randomized, controlled, double-blind study with 111 patients after major abdominal surgery at the University Hospital Heidelberg, Germany, showed with 20 minutes irradiation twice a day (starting on the second postoperative day) in the group with wIRA and visible light VIS (wIRA(+VIS), approximately 75% wIRA, 25% VIS) compared to a control group with only VIS a significant and relevant pain reduction combined with a markedly decreased required dose of analgesics: during 230 single irradiations with wIRA(+VIS) the pain decreased without any exception (median of decrease of pain on postoperative days 2-6 was 13.4 on a 100 mm visual analog scale VAS 0-100), while pain remained unchanged in the control group (p<0.001). The required dose of analgesics was 57-70% lower in the subgroups with wIRA(+VIS) compared to the control subgroups with only VIS (median 598 versus 1398 ml ropivacaine, p<0.001, for peridural catheter analgesia; 31 versus 102 mg piritramide, p=0.001, for patient-controlled analgesia; 3.4 versus 10.2 g metamizole, p=0.005, for intravenous and oral analgesia). During irradiation with wIRA(+VIS) the subcutaneous oxygen partial pressure rose markedly by approximately 30% and the subcutaneous temperature by approximately 2.7°C (both in a tissue depth of 2 cm), whereas both remained unchanged in the control group: after irradiation the median of the subcutaneous oxygen partial pressure was 41.6 (with wIRA) versus 30.2 mm Hg in the control group (p<0.001), the median of the subcutaneous temperature was 38.9 versus 36.4°C (p<0.001). The overall evaluation of the effect of irradiation, including wound healing, pain and cosmesis, assessed on a VAS (0-100 with 50 as indifferent point of no effect) by the surgeon (median 79.0 versus 46.8, p<0.001) or the patient (79.0 versus 50.2, p<0.001) was markedly better in the group with wIRA compared to the control group. This was also true for single aspects: Wound healing assessed on a VAS by the surgeon (median 88.6 versus 78.5, p<0.001) or the patient (median 85.8 versus 81.0, p=0.040, trend) and cosmetic result assessed on a VAS by the surgeon (median 84.5 versus 76.5, p<0.001) or the patient (median 86.7 versus 73.6, p=0.001). In addition there was a trend in favor of the wIRA group to a lower rate of total wound infections (3 of 46, approximately 7%, versus 7 of 48, approximately 15%, p=0.208) including late infections after discharge, caused by the different rate of late infections after discharge: 0 of 46 in the wIRA group and 4 of 48 in the control group. And there was a trend towards a shorter postoperative hospital stay: 9 days in the wIRA group versus 11 days in the control group (p=0.037). The principal finding of this study was that postoperative irradiation with wIRA can improve even a normal wound healing process.
A prospective, randomized, controlled, double-blind study with 45 severely burned children at the Children’s Hospital Park Schönfeld, Kassel, Germany, showed with 30 minutes irradiation once a day (starting on the first day, day of burn as day 1) in the group with wIRA and visible light VIS (wIRA(+VIS), approximately 75% wIRA, 25% VIS) compared to a control group with only VIS a markedly faster reduction of wound size. On the fifth day (after 4 days with irradiation) decision was taken, whether surgical debridement of necrotic tissue was necessary because of deeper (second degree, type b) burns (11 of 21 in the group with wIRA, 14 of 24 in the control group) or non-surgical treatment was possible (second degree, type a, burns). The patients treated conservatively were kept within the study and irradiated till complete reepithelialization. The patients in the group with wIRA showed a markedly faster reduction of wound area: a median reduction of wound size of 50% was reached already after 7 days compared to 9 days in the control group, a median reduction of wound size of 90% was already achieved after 9 days compared to 13 days in the control group. In addition the group with wIRA showed superior results till 3 months after the burn in terms of the overall surgical assessment of the wound, cosmesis, and assessment of effects of irradiation compared to the control group.
In a prospective, randomized, controlled study with 12 volunteers at the University Medical Center Charité, Berlin, Germany, within each volunteer 4 experimental superficial wounds (5 mm diameter) as an acute wound model were generated by suction cup technique, removing the roof of the blister with a scalpel and a sterile forceps (day 1). 4 different treatments were used and investigated during 10 days: no therapy, only wIRA(+VIS) (approximately 75% wIRA, 25% VIS; 30 minutes irradiation once a day), only dexpanthenol (= D-panthenol) cream once a day, wIRA(+VIS) and dexpanthenol cream once a day. Healing of the small experimental wounds was from a clinical point of view excellent with all 4 treatments. Therefore there were only small differences between the treatments with slight advantages of the combination wIRA(+VIS) and dexpanthenol cream and of dexpanthenol cream alone concerning relative change of wound size and assessment of feeling of the wound area. However laser scanning microscopy with a scoring system revealed differences between the 4 treatments concerning the formation of the stratum corneum (from first layer of corneocytes to full formation) especially on the days 5-7: fastest formation of the stratum corneum was seen in wounds treated with wIRA(+VIS) and dexpanthenol cream, second was wIRA(+VIS) alone, third dexpanthenol cream alone and last were untreated wounds. Bacterial counts of the wounds (taken every 2 days) showed, that wIRA(+VIS) and the combination of wIRA(+VIS) with dexpanthenol cream were able to inhibit the colonisation with physiological skin flora up to day 5 when compared with the two other groups (untreated group and group with dexpanthenol cream alone). At any investigated time, the amount of colonisation under therapy with wIRA(+VIS) alone was lower (interpreted as more suppressed) compared with the group with wIRA(+VIS) and dexpanthenol cream.
During rehabilitation after hip and knee endoprosthetic operations the resorption of wound seromas and wound hematomas was both clinically and sonographically faster and pain was reduced by irradiation with wIRA(+VIS).
wIRA can be used successfully for persistent postoperative pain e.g. after thoracotomy.
As perspectives for wIRA it seems clinically prudent to use wIRA both pre- and postoperatively, e.g. in abdominal and thoracic operations. wIRA can be used preoperatively (e.g. during 1-2 weeks) to precondition donor and recipient sites of skin flaps, transplants or partial-thickness skin grafts, and postoperatively to improve wound healing and to decrease pain, inflammation and infections at all mentioned sites. wIRA can be used to support routine pre- or intraoperative antibiotic administration or it might even be discussed to replace this under certain conditions by wIRA.
Principles and working mechanisms of water-filtered infrared-A (wIRA) in relation to wound healing
(2007)
The experience of the pleasant heat of the sun in moderate climatic zones arises from the filtering of the heat radiation of the sun by water vapor in the atmosphere of the earth. The filter effect of water decreases those parts of infrared radiation (most parts of infrared-B and -C and the absorption bands of water within infrared-A), which would cause – by reacting with water molecules in the skin – only an undesired thermal load to the surface of the skin. Technically water-filtered infrared-A (wIRA) is produced in special radiators, whose full spectrum of radiation of a halogen bulb is passed through a cuvette, containing water, which absorbs or decreases the described undesired wavelengths of the infrared radiation. Within infrared the remaining wIRA (within 780-1400 nm) mainly consists of radiation with good penetration properties into tissue and therefore allows – compared to unfiltered heat radiation – a multiple energy transfer into tissue without irritating the skin, similar to the sun’s heat radiation in moderate climatic zones. Typical wIRA radiators emit no ultraviolet (UV) radiation and nearly no infrared-B and -C radiation and the amount of infrared-A radiation in relation to the amount of visible light (380-780 nm) is emphasized.
Water-filtered infrared-A as a special form of heat radiation with a high tissue penetration and with a low thermal load to the skin surface acts both by thermal (related to heat energy transfer) and thermic (temperature depending, with a relevant change of temperature) as well as by non-thermal (without a relevant transfer of heat energy) and non-thermic (not depending on temperature, without a relevant change of temperature) effects. wIRA produces a therapeutically usable field of heat in the tissue and increases tissue temperature, tissue oxygen partial pressure, and tissue perfusion. These three factors are vital for a sufficient tissue supply with energy and oxygen. As wound healing and infection defense (e.g. granulocyte function including their antibacterial oxygen radical formation) depend decisively on a sufficient supply with energy and oxygen, one explanation for the good clinical effect of wIRA on wounds and wound infections can be the improvement of both the energy supply per time (increase of metabolic rate) and the oxygen supply. In addition wIRA has non-thermal and non-thermic effects, which are based on putting direct stimuli on cells and cellular structures.
wIRA can considerably alleviate the pain (with remarkably less need for analgesics) and diminish an elevated wound exudation and inflammation and can show positive immunomodulatory effects. wIRA can advance wound healing or improve an impaired wound healing both in acute and in chronic wounds including infected wounds. Even the normal wound healing process can be improved.
Keywords: water-filtered infrared-A (wIRA), infrared-A radiation, wound healing, thermal and non-thermal effects, thermic and non-thermic effects, energy supply, oxygen supply, tissue oxygen partial pressure, tissue temperature, tissue blood flow, reduction of pain, wound exudation, inflammation, immunomodulatory effects, acute wounds, chronic venous stasis ulcers of the lower legs, problem wounds, wound infections, infection defense, contact-free method, absent expenditure of material, quality of life, prospective, randomized, controlled, double-blind studies
Water-filtered infrared-A radiation (wIRA) is not implicated in cellular degeneration of human skin
(2007)
Background: Excessive exposure to solar ultraviolet radiation is involved in the complex biologic process of cutaneous aging. Wavelengths in the ultraviolet-A and -B range (UV-A and UV-B) have been shown to be responsible for the induction of proteases, e. g. the collagenase matrix metalloproteinase 1 (MMP-1), which are related to cell aging. As devices emitting longer wavelengths are widely used in therapeutic and cosmetic interventions and as the induction of MMP-1 by water-filtered infrared-A (wIRA) had been discussed, it was of interest to assess effects of wIRA on the cellular and molecular level known to be possibly involved in cutaneous degeneration.
Objectives: Investigation of the biological implications of widely used water-filtered infrared-A (wIRA) radiators for clinical use on human skin fibroblasts assessed by MMP-1 gene expression (MMP-1 messenger ribonucleic acid (mRNA) expression).
Methods: Human skin fibroblasts were irradiated with approximately 88% wIRA (780-1400 nm) and 12% red light (RL, 665-780 nm) with 380 mW/cm² wIRA(+RL) (333 mW/cm² wIRA) on the one hand and for comparison with UV-A (330-400 nm, mainly UV-A1) and a small amount of blue light (BL, 400-450 nm) with 28 mW/cm² UV-A(+BL) on the other hand. Survival curves were established by colony forming ability after single exposures between 15 minutes and 8 hours to wIRA(+RL) (340-10880 J/cm² wIRA(+RL), 300-9600 J/cm² wIRA) or 15-45 minutes to UV-A(+BL) (25-75 J/cm² UV-A(+BL)). Both conventional Reverse Transcriptase Polymerase Chain Reaction (RT-PCR) and quantitative real-time RT-PCR techniques were used to determine the induction of MMP-1 mRNA at two physiologic temperatures for skin fibroblasts (30°C and 37°C) in single exposure regimens (15-60 minutes wIRA(+RL), 340-1360 J/cm² wIRA(+RL), 300-1200 J/cm² wIRA; 30 minutes UV-A(+BL), 50 J/cm² UV-A(+BL)) and in addition at 30°C in a repeated exposure protocol (up to 10 times 15 minutes wIRA(+RL) with 340 J/cm² wIRA(+RL), 300 J/cm² wIRA at each time).
Results: Single exposure of cultured human dermal fibroblasts to UV-A(+BL) radiation yielded a very high increase in MMP-1 mRNA expression (11 ±1 fold expression for RT-PCR and 76 ±2 fold expression for real-time RT-PCR both at 30°C, 75 ±1 fold expression for real-time RT-PCR at 37°C) and a dose-dependent decrease in cell survival. In contrast, wIRA(+RL) did not produce cell death and did not induce a systematic increase in MMP-1 mRNA expression (less than twofold expression, within the laboratory range of fluctuation) detectable with the sensitive methods applied. Additionally, repeated exposure of human skin fibroblasts to wIRA(+RL) did not induce MMP-1 mRNA expression systematically (less than twofold expression by up to 10 consecutive wIRA(+RL) exposures and analysis with real-time RT-PCR).
Conclusions: wIRA(+RL) even at the investigated disproportionally high irradiances does not induce cell death or a systematic increase of MMP-1 mRNA expression, both of which can be easily induced by UV-A radiation. Furthermore, these results support previous findings of in vivo investigations on collagenase induction by UV-A but not wIRA and show that infrared-A with appropriate irradiances does not seem to be involved in MMP-1 mediated photoaging of the skin. As suggested by previously published studies wIRA could even be implicated in a protective manner.
Water-filtered infrared-A (wIRA) as a special form of heat radiation with a high tissue penetration and with a low thermal load to the skin surface acts both by thermal and thermic as well as by non-thermal and non-thermic effects. wIRA produces a therapeutically usable field of heat in the tissue and increases tissue temperature, tissue oxygen partial pressure, and tissue perfusion. These three factors are decisive for a sufficient tissue supply with energy and oxygen and consequently as well for wound healing and infection defense.
wIRA can considerably alleviate the pain (with remarkably less need for analgesics) and diminish an elevated wound exudation and inflammation and can show positive immunomodulatory effects. wIRA can advance wound healing or improve an impaired wound healing both in acute and in chronic wounds including infected wounds. Even the normal wound healing process can be improved.
A prospective, randomized, controlled, double-blind study with 111 patients after major abdominal surgery at the University Hospital Heidelberg, Germany, showed with 20 minutes irradiation twice a day (starting on the second postoperative day) in the group with wIRA and visible light VIS (wIRA(+VIS), approximately 75% wIRA, 25% VIS) compared to a control group with only VIS a significant and relevant pain reduction combined with a markedly decreased required dose of analgesics: during 230 single irradiations with wIRA(+VIS) the pain decreased without any exception (median of decrease of pain on postoperative days 2-6 was 13.4 on a 100 mm visual analog scale VAS 0-100), while pain remained unchanged in the control group (p<0.001). The required dose of analgesics was 57-70% lower in the subgroups with wIRA(+VIS) compared to the control subgroups with only VIS (median 598 versus 1398 ml ropivacaine, p<0.001, for peridural catheter analgesia; 31 versus 102 mg piritramide, p=0.001, for patient-controlled analgesia; 3.4 versus 10.2 g metamizole, p=0.005, for intravenous and oral analgesia). During irradiation with wIRA(+VIS) the subcutaneous oxygen partial pressure rose markedly by approximately 30% and the subcutaneous temperature by approximately 2.7°C (both in a tissue depth of 2 cm), whereas both remained unchanged in the control group: after irradiation the median of the subcutaneous oxygen partial pressure was 41.6 (with wIRA) versus 30.2 mm Hg in the control group (p<0.001), the median of the subcutaneous temperature was 38.9 versus 36.4°C (p<0.001). The overall evaluation of the effect of irradiation, including wound healing, pain and cosmesis, assessed on a VAS (0-100 with 50 as indifferent point of no effect) by the surgeon (median 79.0 versus 46.8, p<0.001) or the patient (79.0 versus 50.2, p<0.001) was markedly better in the group with wIRA compared to the control group. This was also true for single aspects: Wound healing assessed on a VAS by the surgeon (median 88.6 versus 78.5, p<0.001) or the patient (median 85.8 versus 81.0, p=0.040, trend) and cosmetic result assessed on a VAS by the surgeon (median 84.5 versus 76.5, p<0.001) or the patient (median 86.7 versus 73.6, p=0.001). In addition there was a trend in favor of the wIRA group to a lower rate of total wound infections (3 of 46, approximately 7%, versus 7 of 48, approximately 15%, p=0.208) including late infections after discharge, caused by the different rate of late infections after discharge: 0 of 46 in the wIRA group and 4 of 48 in the control group. And there was a trend towards a shorter postoperative hospital stay: 9 days in the wIRA group versus 11 days in the control group (p=0.037). The principal finding of this study was that postoperative irradiation with wIRA can improve even a normal wound healing process.
A prospective, randomized, controlled, double-blind study with 45 severely burned children at the Children’s Hospital Park Schönfeld, Kassel, Germany, showed with 30 minutes irradiation once a day (starting on the first day, day of burn as day 1) in the group with wIRA and visible light VIS (wIRA(+VIS), approximately 75% wIRA, 25% VIS) compared to a control group with only VIS a markedly faster reduction of wound size. On the fifth day (after 4 days with irradiation) decision was taken, whether surgical debridement of necrotic tissue was necessary because of deeper (second degree, type b) burns (11 of 21 in the group with wIRA, 14 of 24 in the control group) or non-surgical treatment was possible (second degree, type a, burns). The patients treated conservatively were kept within the study and irradiated till complete reepithelialization. The patients in the group with wIRA showed a markedly faster reduction of wound area: a median reduction of wound size of 50% was reached already after 7 days compared to 9 days in the control group, a median reduction of wound size of 90% was already achieved after 9 days compared to 13 days in the control group. In addition the group with wIRA showed superior results till 3 months after the burn in terms of the overall surgical assessment of the wound, cosmesis, and assessment of effects of irradiation compared to the control group.
In a prospective, randomized, controlled study with 12 volunteers at the University Medical Center Charité, Berlin, Germany, within each volunteer 4 experimental superficial wounds (5 mm diameter) as an acute wound model were generated by suction cup technique, removing the roof of the blister with a scalpel and a sterile forceps (day 1). 4 different treatments were used and investigated during 10 days: no therapy, only wIRA(+VIS) (approximately 75% wIRA, 25% VIS; 30 minutes irradiation once a day), only dexpanthenol (= D-panthenol) cream once a day, wIRA(+VIS) and dexpanthenol cream once a day. Healing of the small experimental wounds was from a clinical point of view excellent with all 4 treatments. Therefore there were only small differences between the treatments with slight advantages of the combination wIRA(+VIS) and dexpanthenol cream and of dexpanthenol cream alone concerning relative change of wound size and assessment of feeling of the wound area. However laser scanning microscopy with a scoring system revealed differences between the 4 treatments concerning the formation of the stratum corneum (from first layer of corneocytes to full formation) especially on the days 5-7: fastest formation of the stratum corneum was seen in wounds treated with wIRA(+VIS) and dexpanthenol cream, second was wIRA(+VIS) alone, third dexpanthenol cream alone and last were untreated wounds. Bacterial counts of the wounds (taken every 2 days) showed, that wIRA(+VIS) and the combination of wIRA(+VIS) with dexpanthenol cream were able to inhibit the colonisation with physiological skin flora up to day 5 when compared with the two other groups (untreated group and group with dexpanthenol cream alone). At any investigated time, the amount of colonisation under therapy with wIRA(+VIS) alone was lower (interpreted as more suppressed) compared with the group with wIRA(+VIS) and dexpanthenol cream.
During rehabilitation after hip and knee endoprosthetic operations the resorption of wound seromas and wound hematomas was both clinically and sonographically faster and pain was reduced by irradiation with wIRA(+VIS).
wIRA can be used successfully for persistent postoperative pain e.g. after thoracotomy.
As perspectives for wIRA it seems clinically prudent to use wIRA both pre- and postoperatively, e.g. in abdominal and thoracic operations. wIRA can be used preoperatively (e.g. during 1-2 weeks) to precondition donor and recipient sites of skin flaps, transplants or partial-thickness skin grafts, and postoperatively to improve wound healing and to decrease pain, inflammation and infections at all mentioned sites. wIRA can be used to support routine pre- or intraoperative antibiotic administration or it might even be discussed to replace this under certain conditions by wIRA.
Principles and working mechanisms of water-filtered infrared-A (wIRA) in relation to wound healing
(2007)
The experience of the pleasant heat of the sun in moderate climatic zones arises from the filtering of the heat radiation of the sun by water vapor in the atmosphere of the earth. The filter effect of water decreases those parts of infrared radiation (most parts of infrared-B and -C and the absorption bands of water within infrared-A), which would cause – by reacting with water molecules in the skin – only an undesired thermal load to the surface of the skin. Technically water-filtered infrared-A (wIRA) is produced in special radiators, whose full spectrum of radiation of a halogen bulb is passed through a cuvette, containing water, which absorbs or decreases the described undesired wavelengths of the infrared radiation. Within infrared the remaining wIRA (within 780-1400 nm) mainly consists of radiation with good penetration properties into tissue and therefore allows – compared to unfiltered heat radiation – a multiple energy transfer into tissue without irritating the skin, similar to the sun’s heat radiation in moderate climatic zones. Typical wIRA radiators emit no ultraviolet (UV) radiation and nearly no infrared-B and -C radiation and the amount of infrared-A radiation in relation to the amount of visible light (380-780 nm) is emphasized. Water-filtered infrared-A as a special form of heat radiation with a high tissue penetration and with a low thermal load to the skin surface acts both by thermal (related to heat energy transfer) and thermic (temperature depending, with a relevant change of temperature) as well as by non-thermal (without a relevant transfer of heat energy) and non-thermic (not depending on temperature, without a relevant change of temperature) effects. wIRA produces a therapeutically usable field of heat in the tissue and increases tissue temperature, tissue oxygen partial pressure, and tissue perfusion. These three factors are vital for a sufficient tissue supply with energy and oxygen. As wound healing and infection defense (e.g. granulocyte function including their antibacterial oxygen radical formation) depend decisively on a sufficient supply with energy and oxygen, one explanation for the good clinical effect of wIRA on wounds and wound infections can be the improvement of both the energy supply per time (increase of metabolic rate) and the oxygen supply. In addition wIRA has non-thermal and non-thermic effects, which are based on putting direct stimuli on cells and cellular structures. wIRA can considerably alleviate the pain (with remarkably less need for analgesics) and diminish an elevated wound exudation and inflammation and can show positive immunomodulatory effects. wIRA can advance wound healing or improve an impaired wound healing both in acute and in chronic wounds including infected wounds. Even the normal wound healing process can be improved. wIRA is contact-free, easily applied, without discomfort to the patient, with absent consumption of material and with a good effect in the depth. The irradiation of the typically uncovered wound is carried out with a wIRA radiator.
Hintergrund: Für die Forschung mit Routinedaten sind Kenntnisse zum Entstehungsprozess sowie zur Validität der Daten Voraussetzung. Ziel der Studie war es, die valide Erfassung forschungsrelevanter Informationen in Arzneimittelroutinedaten zwischen Betäubungsmittel (BtM)-Rezepten und Muster-16-Rezepten (für sonstige Arzneimittel) zu vergleichen.
Methodik: Grundlage waren Routinedaten der Gmünder ErsatzKasse (GEK) aus dem Jahr 2006. Aus den 7,2 Mio. Rezepten wurde eine einfache Zufallsstichprobe von 600 Muster 16 und 600 BtM-Rezepten gezogen. Die eingescannten Originalbelege wurden gesichtet und mit den in Routinedaten befindlichen Informationen verglichen. Die Angaben auf dem Rezept dienten als Goldstandard.
Ergebnisse: Insgesamt ist auf BtM-Rezepten sowohl das Verordnungsdatum (68,1% vs. 92,5%; p<0,0001) wie auch das Abgabedatum (61,8% vs. 85,5%; p<0,0001) schlechter erfasst als auf Muster-16-Rezepten. Auffällig sind die großen Unterschiede zwischen den Apothekenrechenzentren. Die Verrechnungsstelle der Süddeutschen Apotheken GmbH (VSA) als größtes Apothekenrechenzentrum lieferte, im Vergleich zu allen anderen Apothekenrechenzentren, beim Verordnungsdatum (56,1% vs. 73,3%; p<0,0001) wie auch beim Abgabedatum (41,2% vs. 70,8%; p<0,0001) von BtM-Rezepten auffällig seltener korrekte Ergebnisse. Fehler beim Abgabedatum waren bei der VSA assoziiert mit den in den Routinedaten verfügbaren Variablen Art des Rezeptes (Betäubungsmittelrezept vs. Muster 16; Odds Ratio [OR]: 3,12; 95% Konfidenzintervall [KI]: 1,85–5,27), Abgabe laut Routinedaten am Verordnungstag (Ja vs. Nein; OR: 9,33; 95% KI: 1,78–48,87) sowie Verordnung laut Routinedaten am 5., 15. oder 25. (Ja vs. Nein; OR: 6,70; 95% KI: 2,85–15,76).
Schlussfolgerung: Es besteht für hiesige Routinedaten ein erheblicher Mangel an methodisch fundierten Analysen bzw. Validierungsstudien, insbesondere auch zur Güte von Diagnosen.