Refine
Year of publication
- 2020 (2) (remove)
Document Type
- Article (2)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- acoustic emission (1)
- archeological modeling (1)
- crepitation (1)
- crepitus (1)
- human–environment interaction (1)
- knee noise (1)
- knee sound (1)
- measurement properties (1)
- open science (1)
- paleoclimate modeling (1)
In this report, we present the contributions, outcomes, ideas, discussions and conclusions obtained at the PaleoMaps Workshop 2019, that took place at the Institute of Geography of the University of Cologne on 23 and 24 September 2019. The twofold aim of the workshop was: (1) to provide an overview of approaches and methods that are presently used to incorporate paleoenvironmental information in human–environment interaction modeling applications, and building thereon; (2) to devise new approaches and solutions that might be used to enhance the reconstruction of past human–environmental interconnections. This report first outlines the presented papers, and then provides a joint protocol of the often extensive discussions that came up following the presentations or else during the refreshment intervals. It concludes by adressing the open points to be resolved in future research avenues, e.g., implementation of open science practices, new procedures for reviewing of publications, and future concepts for quality assurance of the often complex paleoenvironmental data. This report may serve as an overview of the state of the art in paleoenvironment mapping and modeling. It includes an extensive compilation of the basic literature, as provided by the workshop attendants, which will itself facilitate the necessary future research.
Knee acoustic emissions provide information about joint health and loading in motion. As the reproducibility of knee acoustic emissions by vibroarthrography is yet unknown, we evaluated the intrasession and interday reliability of knee joint sounds. In 19 volunteers (25.6 ± 2.0 years, 11 female), knee joint sounds were recorded by two acoustic sensors (16,000 Hz; medial tibial plateau, patella). All participants performed four sets standing up/sitting down (five repetitions each). For measuring intrasession reliability, we used a washout phase of 30 min between the first three sets, and for interday reliability we used a washout phase of one week between sets 3 and 4. The mean amplitude (dB) and median power frequency (Hz, MPF) were analyzed for each set. Intraclass correlation coefficients (ICCs (2,1)), standard errors of measurement (SEMs), and coefficients of variability (CVs) were calculated. The intrasession ICCs ranged from 0.85 to 0.95 (tibia) and from 0.73 to 0.87 (patella). The corresponding SEMs for the amplitude were ≤1.44 dB (tibia) and ≤2.38 dB (patella); for the MPF, SEMs were ≤13.78 Hz (tibia) and ≤14.47 Hz (patella). The intrasession CVs were ≤0.06 (tibia) and ≤0.07 (patella) (p < 0.05). The interday ICCs ranged from 0.24 to 0.33 (tibia) and from 0 to 0.82 (patella) for both the MPF and amplitude. The interday SEMs were ≤4.39 dB (tibia) and ≤6.85 dB (patella) for the amplitude and ≤35.39 Hz (tibia) and ≤15.64 Hz (patella) for the MPF. The CVs were ≤0.14 (tibia) and ≤0.08 (patella). Knee joint sounds were highly repeatable within a single session but yielded inconsistent results for the interday reliability.