Background: Despite improvements in liver surgery over the past decades, hemostasis during hepatic resections remains challenging. This multicenter randomized study compares the hemostatic effect of a collagen hemostat vs. a carrier-bound fibrin sealant after hepatic resection.
Methods: Patients scheduled for elective liver resection were randomized intraoperatively to receive either the collagen hemostat (COLL) or the carrier-bound fibrin sealant (CBFS) for secondary hemostasis. The primary endpoint was the proportion of patients with hemostasis after 3 min. Secondary parameters were the proportions of patients with hemostasis after 5 and 10 min, the total time to hemostasis, and the complication rates during a 3 months follow-up period.
Results: A total of 128 patients were included. In the COLL group, 53 out of 61 patients (86.9 %) achieved complete hemostasis within 3 min after application of the hemostat compared to 52 out of 65 patients (80.0 %) in the CBFS group. The 95 % confidence interval for this difference [−6.0 %, 19.8 %] does not include the lower noninferiority margin (−10 %). Thus, the COLL treatment can be regarded as noninferior to the comparator. The proportions of patients with hemostasis after 3, 5, and 10 min were not significantly different between the two study arms. Postoperative mortality and morbidity were similar in both treatment groups.
Conclusion: The collagen hemostat is as effective as the carrier-bound fibrin sealant in obtaining secondary hemostasis during liver resection with a comparable complication rate.
Background: Haemostasis in liver surgery remains a challenge despite improved resection techniques. Oozing from blood vessels too small to be ligated necessitate a treatment with haemostats in order to prevent complications attributed to bleeding. There is good evidence from randomised trials for the efficacy of fibrin sealants, on their own or in combination with a carrier material. A new haemostatic device is Sangustop(R). It is a collagen based material without any coagulation factors. Pre-clinical data for Sangustop(R) showed superior haemostatic effect. This present study aims to show that in the clinical situation Sangustop(R) is not inferior to a carrier-bound fibrin sealant (Tachosil(R)) as a haemostatic treatment in hepatic resection. Methods: This is a multi-centre, patient-blinded, intra-operatively randomised controlled trial. A total of 126 patients planned for an elective liver resection will be enrolled in eight surgical centres. The primary objective of this study is to show the non-inferiority of Sangustop(R) versus a carrier-bound fibrin sealant (Tachosil(R)) in achieving haemostasis after hepatic resection. The surgical intervention is standardised with regard to devices and techniques used for resection and primary haemostasis. Patients will be followed-up for three months for complications and adverse events. Discussion: This randomised controlled trial (ESSCALIVER) aims to compare the new collagen haemostat Sangustop(R) with a carrier-bound fibrin sealant which can be seen as a "gold standard" in hepatic and other visceral organ surgery. If non-inferiority is shown other criteria than the haemostatic efficacy (e.g. costs, adverse events rate) may be considered for the choice of the most appropriate treatment. Trial Registration: NCT00918619