Refine
Year of publication
Document Type
- Preprint (125)
- Article (56)
- Conference Proceeding (1)
- Working Paper (1)
Has Fulltext
- yes (183)
Is part of the Bibliography
- no (183)
Keywords
- Hadron-Hadron Scattering (8)
- Jets (4)
- Collective Flow (3)
- Heavy Ion Experiments (3)
- Heavy Quark Production (3)
- Quarkonium (2)
- Biomarker (1)
- Cancer genomics (1)
- Collective Flow, (1)
- Corneometrie (1)
Institute
Meeting Abstract : Deutscher Kongress für Orthopädie und Unfallchirurgie ; 73. Jahrestagung der Deutschen Gesellschaft für Unfallchirurgie ; 95. Tagung der Deutschen Gesellschaft für Orthopädie und Orthopädische Chirurgie ; 50. Tagung des Berufsverbandes der Fachärzte für Orthopädie und Unfallchirurgie ; 21. - 24.10.2009, Berlin Fragestellung: Ziel war die Evaluierung der funktionellen und radiologischen Ergebnisse nach osteosynthestischer Versorgung von Olecranonfrakturen mit einer zur Hakenplatte modifizierten Drittelrohrplatte. Methodik: In einem Zeitraum von 12 Monaten wurden 29 Patienten mit Olecranonfrakturen prospektiv erfasst und eine Osteosynthese mit einer zur Hakenplatte modifizierten Kleinfragment-Drittelrohrplatte durchgeführt. Eine additive Verschraubung von zusätzlichen Fragmenten erfolgte bei 6 Patienten (20%). Das mittlere Patientenalter zum Unfallzeitpunkt betrug 50 Jahre (Min 29/ Max 83). Unter Verwendung der Frakturklassifikation nach Schatzker stellte sich in 8 Fällen (28%) eine Querfraktur vom Typ A, in 6 Fällen (20%) eine Querfraktur mit Impaktion vom Typ B und in 15 Fällen (52%) eine Mehrfragmentfraktur vom Typ D dar. Bei 4 Patienten (14%) lag eine offene Fraktursituation vor. Nach im Mittel 7,2 Monaten (Min 6/ Max 8) wurde das funktionelle Outcome anhand des Mayo Elbow Performence Scores (MEPS), der visuellen Analogskala (VAS) und des Disabilities of the Arm, Shoulder and Hand Scores (DASH) bewertet sowie die radiologischen Befunde erhoben. Ergebnisse und Schlussfolgerungen: Das Ziel einer primär übungsstabilen Osteosynthese konnte bei allen Patienten erreicht werden. Unter Verwendung des MEPS wurden annähernd ausschließlich sehr gute (12 Fälle/41%) und gute (16 Fälle/55%) Ergebnisse erzielt. Lediglich bei einem Patienten ergab sich ein nur befriedigendes Ergebnis. Der mittlere Punktwert für den MEPS betrug 91,4 (Min 65/Max 100). In der VAS konnte ein Mittelwert von 8,2 Punkten (Min 7/Max 10) erzielt werden (0=keine Zufriedenheit, 10=volle Zufriedenheit). Der mittlere DASH-Wert betrug 16,2 Punkte (Min 0/Max 39). Der mittlere Bewegungsumfang betrug für Extension/Flexion bei einem durchschnittlichen Streckdefizit von 8° (Min 0°/Max 25°) und einer Beugung von 135° (Min 105°/Max 155°) 125° (Min 90°/Max 155°). Die Unterarmumwendbewegungen waren mit 175° (Min 165°/Max 180°) kaum eingeschränkt. Bei keinem Patienten gab es postoperative Komplikationen. Eine zur Hakenplatte modifizierte Drittelrohrplatte stellt im Gegensatz zu präformierten, winkelstabilen Implantaten eine kostengünstige Alternative zur Osteosynthese bei Olecranonfrakturen dar. Auch bei komplexen mehrfragmentären Frakturtypen und osteoporotischer Knochenqualität konnte so im nachuntersuchten Kollektiv eine sichere Frakturretention erzielt werden. Hinsichtlich des funktionellen Ergebnisses profitieren die Patienten von einer dadurch unmittelbar postoperativ möglichen, physiotherapeutischen Nachbehandlung. Das für die Hakenplatte benötigte Osteosynthesematerial (Kleinfragment-Drittelrohrplatte) ist nahezu überall verfügbar und lässt sich in kurzer Zeit der individuellen Anatomie und Frakturmorphologie anpassen. Eine Drahtmigration, wie bei der weit verbreiteten Zuggurtungsosteosynthese häufig beobachtet, ist ausgeschlossen.
Background: Biosurfactants are surface-active molecules produced by different microorganisms and display a promising alternative to synthetically derived food emulsifiers. One of these biosurfactants, synthesized by Bacillus subtilis, is the lipopeptide surfactin, which composes a linear fatty acid and cyclic peptide moiety. This study explores the interfacial and emulsion forming properties of surfactin to further characterize its suitability as an O/W emulsifier in food formulations.
Results: Surfactin revealed a high interfacial activity with a reduction of interfacial tension of 83.26 % to 4.21 ± 0.11 mN/m. O/W emulsions (coil = 10 % w/w) were prepared by high-pressure homogenization, which yielded volume-based mean particle sizes below 1 μm already at low emulsifier concentrations of 0.01 % (w/w). Environmental stress experiments revealed that emulsions were stable between pH 6 to pH 9. Furthermore, neither phase separation nor extensive emulsion instability was observed with NaCl addition up to 0.5 M. However, CaCl2 addition (> 3 mM) destabilized surfactin mediated emulsions. Finally, the main emulsion forming and stabilization effect of surfactin was related to its high interfacial activity and the high degree of electrostatic repulsion between the oil droplets (i.e. zeta-potential of up to −100 mV).
Conclusion; In comparison to other natural and synthetic emulsifiers, the results showed that surfactin is a strong candidate to form and stabilize O/W emulsions under the reported conditions.
Water-filtered infrared-A (wIRA) can act as a penetration enhancer for topically applied substances
(2008)
Background: Water-filtered infrared-A (wIRA) irradiation has been shown to enhance penetration of clinically used topically applied substances in humans through investigation of functional effects of penetrated substances like vasoconstriction by cortisone.
Aim of the study: Investigation of the influence of wIRA irradiation on the dermatopharmacokinetics of topically applied substances by use of optical methods, especially to localize penetrating substances, in a prospective randomised controlled study in humans.
Methods: The penetration profiles of the hydrophilic dye fluorescein and the lipophilic dye curcumin in separate standard water-in-oil emulsions were determined on the inner forearm of test persons by tape stripping in combination with spectroscopic measurements. Additionally, the penetration was investigated in vivo by laser scanning microscopy. Transepidermal water loss, hydration of the epidermis, and surface temperature were determined. Three different procedures (modes A, B, C) were used in a randomised order on three separate days of investigation in each of 12 test persons. In mode A, the two dyes were applied on different skin areas without water-filtered infrared-A (wIRA) irradiation. In mode B, the skin surface was irradiated with wIRA over 30 min before application of the two dyes (Hydrosun® radiator type 501, 10 mm water cuvette, orange filter OG590, water-filtered spectrum: 590–1400 nm with dominant amount of wIRA). In mode C, the two dyes were applied and immediately afterwards the skin was irradiated with wIRA over 30 min. In all modes, tape stripping started 30 min after application of the formulations. Main variable of interest was the ratio of the amount of the dye in the deeper (second) 10% of the stratum corneum to the amount of the dye in the upper 10% of the stratum corneum.
Results: The penetration profiles of the hydrophilic fluorescein showed in case of pretreatment or treatment with wIRA (modes B and C) an increased penetration depth compared to the non-irradiated skin (mode A): The ratio of the amount of the dye in the deeper (second) 10% of the stratum corneum to the amount of the dye in the upper 10% of the stratum corneum showed medians and interquartile ranges for mode A of 0.017 (0.007/0.050), for mode B of 0.084 (0.021/0.106), for mode C of 0.104 (0.069/0.192) (difference between modes: p=0.0112, significant; comparison mode A with mode C: p<0.01, significant). In contrast to fluorescein, the lipophilic curcumin showed no differences in the penetration kinetics, in reference to whether the skin was irradiated with wIRA or not. These effects were confirmed by laser scanning microscopy. Water-filtered infrared-A irradiation increased the hydration of the stratum corneum: transepidermal water loss rose from approximately 8.8 g m-2 h-1 before wIRA irradiation to 14.2 g m-2 h-1 after wIRA irradiation and skin hydration rose from 67 to 87 relative units. Skin surface temperature increased from 32.8°C before wIRA to 36.4°C after wIRA irradiation.
Discussion: The better penetration of the hydrophilic dye fluorescein after or during skin irradiation (modes B and C) can be explained by increased hydration of the stratum corneum by irradiation with wIRA.
Conclusions: As most topically applied substances for the treatment of patients are mainly hydrophilic, wIRA can be used to improve the penetration of substances before or after application of substances – in the first case even of thermolabile substances – with a broad clinical relevance as a contact free alternative to an occlusive dressing.
From July 2002 to March 2004 the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) aboard the European Space Agency´s Environmental Satellite (Envisat) measured nearly continuously mid infrared limb radiance spectra. These measurements are utilised to retrieve the global distribution of the chlorofluorocarbon CFC-11 by applying a new fast forward model for Envisat MIPAS and an accompanying optimal estimation retrieval processor. A detailed analysis shows that the total retrieval errors of the individual CFC-11 volume mixing ratios are typically below 10% in the altitude range 10 to 25 km and that the systematic components dominate. Contribution of a priori information to the retrieval results are less than 5 to 10% and the vertical resolution of the observations is about 3 to 4 km in the same vertical range. The data are successfully validated by comparison with several other space experiments, an air-borne in-situ instrument, measurements from ground-based networks, and independent Envisat MIPAS analyses. The retrieval results from 425 000 Envisat MIPAS limb scans are compiled to provide a new climatological data set of CFC-11. The climatology shows significantly lower CFC-11 abundances in the lower stratosphere compared with the Reference Atmospheres for MIPAS (RAMstan V3.1) climatology. Depending on the atmospheric conditions the differences between the climatologies are up to 30 to 110 ppt (45 to 150%) at 19 to 27 km altitude. Additionally, time series of CFC-11 mean abundance and variability for five latitudinal bands are presented. The observed CFC-11 distributions can be explained by the residual mean circulation and large-scale eddy-transports in the upper troposphere and lower stratosphere. The new CFC-11 data set is well suited for further scientific studies.
Measurements of the production cross sections of prompt D0, D+, D∗+, D+s, Λ+c, and Ξ+c charm hadrons at midrapidity in proton−proton collisions at s√=13 TeV with the ALICE detector are presented. The D-meson cross sections as a function of transverse momentum (pT) are provided with improved precision and granularity. The ratios of pT-differential meson production cross sections based on this publication and on measurements at different rapidity and collision energy provide a constraint on gluon parton distribution functions at low values of Bjorken-x (10−5−10−4). The measurements of Λ+c (Ξ+c) baryon production extend the measured pT intervals down to pT=0(3)~GeV/c. These measurements are used to determine the charm-quark fragmentation fractions and the cc¯¯ production cross section at midrapidity (|y|<0.5) based on the sum of the cross sections of the weakly-decaying ground-state charm hadrons D0, D+, D+s, Λ+c, Ξ0c and, for the first time, Ξ+c, and of the strongly-decaying J/psi mesons. The first measurements of Ξ+c and Σ0,++c fragmentation fractions at midrapidity are also reported. A significantly larger fraction of charm quarks hadronising to baryons is found compared to e+e− and ep collisions. The cc¯¯ production cross section at midrapidity is found to be at the upper bound of state-of-the-art perturbative QCD calculations.
Measurements of the production cross sections of prompt D0, D+, D∗+, D+s, Λ+c, and Ξ+c charm hadrons at midrapidity in proton−proton collisions at s√=13 TeV with the ALICE detector are presented. The D-meson cross sections as a function of transverse momentum (pT) are provided with improved precision and granularity. The ratios of pT-differential meson production cross sections based on this publication and on measurements at different rapidity and collision energy provide a constraint on gluon parton distribution functions at low values of Bjorken-x (10−5−10−4). The measurements of Λ+c (Ξ+c) baryon production extend the measured pT intervals down to pT=0(3)~GeV/c. These measurements are used to determine the charm-quark fragmentation fractions and the cc¯¯ production cross section at midrapidity (|y|<0.5) based on the sum of the cross sections of the weakly-decaying ground-state charm hadrons D0, D+, D+s, Λ+c, Ξ0c and, for the first time, Ξ+c, and of the strongly-decaying J/psi mesons. The first measurements of Ξ+c and Σ0,++c fragmentation fractions at midrapidity are also reported. A significantly larger fraction of charm quarks hadronising to baryons is found compared to e+e− and ep collisions. The cc¯¯ production cross section at midrapidity is found to be at the upper bound of state-of-the-art perturbative QCD calculations.
The Chiral Magnetic Wave (CMW) phenomenon is essential to provide insights into the strong interaction in QCD, the properties of the quark-gluon plasma, and the topological characteristics of the early universe, offering a deeper understanding of fundamental physics in high-energy collisions. Measurements of the charge-dependent anisotropic flow coefficients are studied in Pb-Pb collisions at center-of-mass energy per nucleon-nucleon collision sNN−−−√= 5.02 TeV to probe the CMW. In particular, the slope of the normalized difference in elliptic (v2) and triangular (v3) flow coefficients of positively and negatively charged particles as a function of their event-wise normalized number difference, is reported for inclusive and identified particles. The slope rNorm3 is found to be larger than zero and to have a magnitude similar to rNorm2, thus pointing to a large background contribution for these measurements. Furthermore, rNorm2 can be described by a blast wave model calculation that incorporates local charge conservation. In addition, using the event shape engineering technique yields a fraction of CMW (fCMW) contribution to this measurement which is compatible with zero. This measurement provides the very first upper limit for fCMW, and in the 10-60% centrality interval it is found to be 26% (38%) at 95% (99.7%) confidence level.
Measurements of charged-particle production in pp, p−Pb, and Pb−Pb collisions in the toward, away, and transverse regions with the ALICE detector are discussed. These regions are defined event-by-event relative to the azimuthal direction of the charged trigger particle, which is the reconstructed particle with the largest transverse momentum (ptrigT) in the range 8<ptrigT<15 GeV/c. The toward and away regions contain the primary and recoil jets, respectively; both regions are accompanied by the underlying event (UE). In contrast, the transverse region perpendicular to the direction of the trigger particle is dominated by the so-called UE dynamics, and includes also contributions from initial- and final-state radiation. The relative transverse activity classifier, RT=NTch/⟨NTch⟩, is used to group events according to their UE activity, where NTch is the charged-particle multiplicity per event in the transverse region and ⟨NTch⟩ is the mean value over the whole analysed sample. The energy dependence of the RT distributions in pp collisions at s√=2.76, 5.02, 7, and 13 TeV is reported, exploring the Koba-Nielsen-Olesen (KNO) scaling properties of the multiplicity distributions. The first measurements of charged-particle pT spectra as a function of RT in the three azimuthal regions in pp, p−Pb, and Pb−Pb collisions at sNN−−−√=5.02 TeV are also reported. Data are compared with predictions obtained from the event generators PYTHIA 8 and EPOS LHC. This set of measurements is expected to contribute to the understanding of the origin of collective-like effects in small collision systems (pp and p−Pb).
Measurements of charged-particle production in pp, p−Pb, and Pb−Pb collisions in the toward, away, and transverse regions with the ALICE detector are discussed. These regions are defined event-by-event relative to the azimuthal direction of the charged trigger particle, which is the reconstructed particle with the largest transverse momentum (ptrigT) in the range 8<ptrigT<15 GeV/c. The toward and away regions contain the primary and recoil jets, respectively; both regions are accompanied by the underlying event (UE). In contrast, the transverse region perpendicular to the direction of the trigger particle is dominated by the so-called UE dynamics, and includes also contributions from initial- and final-state radiation. The relative transverse activity classifier, RT=NTch/⟨NTch⟩, is used to group events according to their UE activity, where NTch is the charged-particle multiplicity per event in the transverse region and ⟨NTch⟩ is the mean value over the whole analysed sample. The energy dependence of the RT distributions in pp collisions at s√=2.76, 5.02, 7, and 13 TeV is reported, exploring the Koba-Nielsen-Olesen (KNO) scaling properties of the multiplicity distributions. The first measurements of charged-particle pT spectra as a function of RT in the three azimuthal regions in pp, p−Pb, and Pb−Pb collisions at sNN−−−√=5.02 TeV are also reported. Data are compared with predictions obtained from the event generators PYTHIA 8 and EPOS LHC. This set of measurements is expected to contribute to the understanding of the origin of collective-like effects in small collision systems (pp and p−Pb).
A newly developed observable for correlations between symmetry planes, which characterize the direction of the anisotropic emission of produced particles, is measured in Pb-Pb collisions at sNN−−−√=2.76 TeV with ALICE. This so-called Gaussian Estimator allows for the first time the study of these quantities without the influence of correlations between different flow amplitudes. The centrality dependence of various correlations between two, three and four symmetry planes is presented. The ordering of magnitude between these symmetry plane correlations is discussed and the results of the Gaussian Estimator are compared with measurements of previously used estimators. The results utilizing the new estimator lead to significantly smaller correlations than reported by studies using the Scalar Product method. Furthermore, the obtained symmetry plane correlations are compared to state-of-the-art hydrodynamic model calculations for the evolution of heavy-ion collisions. While the model predictions provide a qualitative description of the data, quantitative agreement is not always observed, particularly for correlators with significant non-linear response of the medium to initial state anisotropies of the collision system. As these results provide unique and independent information, their usage in future Bayesian analysis can further constrain our knowledge on the properties of the QCD matter produced in ultrarelativistic heavy-ion collisions.