Refine
Document Type
- Article (4)
Language
- English (4)
Has Fulltext
- yes (4)
Is part of the Bibliography
- no (4)
Keywords
- Alternating Phase Focusing (1)
- Beam dynamics simulation (1)
- Continuous wave (1)
- Decision making (1)
- Eclampsia (1)
- Heavy ion (1)
- Hospitals (1)
- Linear accelerator (1)
- Nonlinear beam dynamics (1)
- Physicians (1)
Influence of the sFlt-1/PlGF ratio on clinical decision-making in women with suspected preeclampsia
(2016)
Objective: To evaluate the influence of the soluble fms-like tyrosine kinase 1/placental growth factor ratio in physicians’ decision making in pregnant women with signs and symptoms of preeclampsia in routine clinical practice.
Methods: A multicenter, prospective, open, non-interventional study enrolled pregnant women presenting with preeclampsia signs and symptoms in several European perinatal care centers. Before the soluble fms-like tyrosine kinase 1/placental growth factor ratio result was known, physicians documented intended clinical procedures using an iPad® application (data locked/time stamped). After the result was available, clinical decisions were confirmed or revised and documented. An independent adjudication committee evaluated the appropriateness of decisions based on maternal/fetal outcomes. Clinician decision making with regard to hospitalization was the primary outcome.
Results: In 16.9% of mothers (20/118) the hospitalization decision was changed after knowledge of the ratio. In 13 women (11.0%), the initial decision to hospitalize was changed to no hospitalization. In seven women (5.9%) the revised decision was hospitalization. All revised decisions were considered appropriate by the panel of adjudicators (McNemar test; p < 0.0001).
Conclusions: The use of the soluble fms-like tyrosine kinase 1/placental growth factor test influenced clinical decision making towards appropriate hospitalization in a considerable proportion of women with suspected preeclampsia. This is the first study to demonstrate the impact of angiogenic biomarkers on decision making in a routine clinical practice.
Recently the Universal Linear Accelerator (UNILAC) serves as a powerful high duty factor (25%) heavy ion beam accelerator for the ambitious experiment program at GSI. Beam time availability for SHE (Super Heavy Element)-research will be decreased due to the limitation of the UNILAC providing Uranium beams with an extremely high peak current for FAIR simultaneously. To keep the GSI-SHE program competitive on a high level and even beyond, a standalone superconducting continuous wave (100% duty factor) LINAC in combination with the upgraded GSI High Charge State injector is envisaged. In preparation for this, the first LINAC section (financed by HIM and GSI) will be tested with beam in 2017, demonstrating the future experimental capabilities. Further on the construction of an extended cryo module comprising two shorter Crossbar-H cavities is foreseen to test until end of 2017. As a final R&D step towards an entire LINAC three advanced cryo modules, each comprising two CH cavities, should be built until 2019, serving for first user experiments at the Coulomb barrier.
The new heavy ion superconducting continuous wave HElmholtz LInear ACcelerator (HELIAC) is under construction at GSI. A normal conducting injector, comprising an ECR ion source, an RFQ and a DTL, is recently in development. The new Interdigital H-mode DTL, presented in this paper, accelerates the heavy ion beam from 300 to 1400 keV/u, applying an Alternating Phase Focusing (APF) beam dynamics scheme. This APF section, consisting of two separately controlled tanks, has to provide for stable routine operation with assistance of dedicated beam diagnostics devices in the Intertank section. The installed quadrupole lenses and beam steerers installed there ensure full transmission in a wide range of input beam parameters.
The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.