Refine
Year of publication
Document Type
- Preprint (521)
- Article (278)
- Contribution to a Periodical (2)
- Review (2)
- Conference Proceeding (1)
Has Fulltext
- yes (804)
Is part of the Bibliography
- no (804)
Keywords
Institute
Aims: Averaged measurements, but not the progression based on multiple assessments of carotid intima-media thickness, (cIMT) are predictive of cardiovascular disease (CVD) events in individuals. Whether this is true for conventional risk factors is unclear.
Methods and results: An individual participant meta-analysis was used to associate the annualised progression of systolic blood pressure, total cholesterol, low-density lipoprotein cholesterol and high-density lipoprotein cholesterol with future cardiovascular disease risk in 13 prospective cohort studies of the PROG-IMT collaboration (n = 34,072). Follow-up data included information on a combined cardiovascular disease endpoint of myocardial infarction, stroke, or vascular death. In secondary analyses, annualised progression was replaced with average. Log hazard ratios per standard deviation difference were pooled across studies by a random effects meta-analysis. In primary analysis, the annualised progression of total cholesterol was marginally related to a higher cardiovascular disease risk (hazard ratio (HR) 1.04, 95% confidence interval (CI) 1.00 to 1.07). The annualised progression of systolic blood pressure, low-density lipoprotein cholesterol and high-density lipoprotein cholesterol was not associated with future cardiovascular disease risk. In secondary analysis, average systolic blood pressure (HR 1.20 95% CI 1.11 to 1.29) and low-density lipoprotein cholesterol (HR 1.09, 95% CI 1.02 to 1.16) were related to a greater, while high-density lipoprotein cholesterol (HR 0.92, 95% CI 0.88 to 0.97) was related to a lower risk of future cardiovascular disease events.
Conclusion: Averaged measurements of systolic blood pressure, low-density lipoprotein cholesterol and high-density lipoprotein cholesterol displayed significant linear relationships with the risk of future cardiovascular disease events. However, there was no clear association between the annualised progression of these conventional risk factors in individuals with the risk of future clinical endpoints.
Correction to: Infection (2020) 48:723–733 https://doi.org/10.1007/s15010-020-01469-6. The original version of this article unfortunately contained a mistake. In this article the authors Dirk Schürmann at affiliation Charité, University Medicine, Berlin, Olaf Degen at affiliation University Clinic Hamburg Eppendorf, Hamburg and Heinz-August Horst at affiliation University Hospital Schleswig–Holstein, Kiel, Germany were missing from the author list. The original article has been corrected.
The COLTRIMS Reaction Microscope C-REMI can image the momentum vectors of all emitted charged fragments in an atomic or molecular reactions similar to the bubble chamber in high energy particle physics. C-REMI can detect fragments with “zero” kinetic energy in an ultrahigh vacuum environment by projecting them with weak electromagnetic fields onto position-sensitive detectors. Geometrically a nearly 4π collection solid angle and a nearly 50% efficiency for a fivefold multi-coincidence can be achieved. Measuring time-of-flight and detector position the momenta of the fragments can be measured with excellent resolution (<0.01 a.u.; see A1 in the Appendix). Thus, multivector correlations in momentum space are measured, which provide insight into the entangled dynamics of atomic and molecular quantum systems. From these vector-correlations phases and energies can be deduced which allow for relative time measurements even in the zeptosecond range. C-REMI provides a “spyhole” into the secrets of ultrafast dynamics of atomic and molecular processes. It is applied today around the globe in numerous research projects in physics and chemistry. The purpose for writing this article is to demonstrate the universal application possibilities of C-REMI, and its high multi-coincidence efficiency and high momentum resolution. This paper will not give a review on all milestone experiments performed with C-REMI.
A small electrostatic storage ring is the central machine of the Frankfurt Ion Storage Experiments (FIRE) which will be built at the new Stern-Gerlach Center of Frankfurt University. As a true multiuser, multipurpose facility with ion energies up to 50 keV, it will allow new methods to analyze complex many-particle systems from atoms to very large biomolecules. With envisaged storage times of some seconds and beam emittances in the order of a few mm mrad, measurements with up to 6 orders of magnitude better resolutions as compared to single-pass experiments become possible. In comparison to earlier designs, the ring lattice was modified in many details: Problems in earlier designs were related to, e.g., the detection of light particles and highly charged ions with different charge states. Therefore, the deflectors were redesigned completely, allowing a more flexible positioning of the diagnostics. Here, after an introduction to the concept of electrostatic machines, an overview of the planned FIRE is given and the ring lattice and elements are described in detail.