Refine
Year of publication
Has Fulltext
- yes (145)
Is part of the Bibliography
- no (145)
Keywords
- LHC (7)
- ALICE (3)
- ALICE experiment (3)
- HNSCC (3)
- Hadron-Hadron Scattering (3)
- Penile carcinomas (3)
- Radiotherapy (3)
- pp collisions (3)
- Beauty production (2)
- Breast cancer (2)
Institute
Background: To test the impact of urethral sphincter length (USL) and anatomic variants of prostatic apex (Lee-type classification) in preoperative multiparametric magnet resonance imaging (mpMRI) on mid-term continence in prostate cancer patients treated with radical prostatectomy (RP). Methods: We relied on an institutional tertiary-care database to identify patients who underwent RP between 03/2018 and 12/2019 with preoperative mpMRI and data available on mid-term (>6 months post-surgery) urinary continence, defined as usage 0/1 (-safety) pad/24 h. Univariable and multivariable logistic regression models were fitted to test for predictor status of USL and prostatic apex variants, defined in mpMRI measurements. Results: Of 68 eligible patients, rate of mid-term urinary continence was 81% (n = 55). Median coronal (15.1 vs. 12.5 mm) and sagittal (15.4 vs. 11.1 mm) USL were longer in patients reporting urinary continence in mid-term follow-up (both p < 0.01). No difference was recorded for prostatic apex variants distribution (Lee-type) between continent vs. incontinent patients (p = 0.4). In separate multivariable logistic regression models, coronal (odds ratio (OR): 1.35) and sagittal (OR: 1.67) USL, but not Lee-type, were independent predictors for mid-term continence. Conclusion: USL, but not apex anatomy, in preoperative mpMRI was associated with higher rates of urinary continence at mid-term follow-up.
We report the results of the femtoscopic analysis of pairs of identical pions measured in p-Pb collisions at sNN−−−√=5.02 TeV. Femtoscopic radii are determined as a function of event multiplicity and pair momentum in three spatial dimensions. As in the pp collision system, the analysis is complicated by the presence of sizable background correlation structures in addition to the femtoscopic signal. The radii increase with event multiplicity and decrease with pair transverse momentum. When taken at comparable multiplicity, the radii measured in p-Pb collisions, at high multiplicity and low pair transverse momentum, are 10-20% higher than those observed in pp collisions but below those observed in A-A collisions. The results are compared to hydrodynamic predictions at large event multiplicity as well as discussed in the context of calculations based on gluon saturation.
We report the results of the femtoscopic analysis of pairs of identical pions measured in p-Pb collisions at sNN−−−√=5.02 TeV. Femtoscopic radii are determined as a function of event multiplicity and pair momentum in three spatial dimensions. As in the pp collision system, the analysis is complicated by the presence of sizable background correlation structures in addition to the femtoscopic signal. The radii increase with event multiplicity and decrease with pair transverse momentum. When taken at comparable multiplicity, the radii measured in p-Pb collisions, at high multiplicity and low pair transverse momentum, are 10-20% higher than those observed in pp collisions but below those observed in A-A collisions. The results are compared to hydrodynamic predictions at large event multiplicity as well as discussed in the context of calculations based on gluon saturation.
We report the results of the femtoscopic analysis of pairs of identical pions measured in p-Pb collisions at sNN−−−√=5.02 TeV. Femtoscopic radii are determined as a function of event multiplicity and pair momentum in three spatial dimensions. As in the pp collision system, the analysis is complicated by the presence of sizable background correlation structures in addition to the femtoscopic signal. The radii increase with event multiplicity and decrease with pair transverse momentum. When taken at comparable multiplicity, the radii measured in p-Pb collisions, at high multiplicity and low pair transverse momentum, are 10-20% higher than those observed in pp collisions but below those observed in A-A collisions. The results are compared to hydrodynamic predictions at large event multiplicity as well as discussed in the context of calculations based on gluon saturation.
The first measurement of two-pion Bose–Einstein correlations in central Pb–Pb collisions at √sNN=2.76 TeV at the Large Hadron Collider is presented. We observe a growing trend with energy now not only for the longitudinal and the outward but also for the sideward pion source radius. The pion homogeneity volume and the decoupling time are significantly larger than those measured at RHIC.
Penile squamous cell carcinomas are rare tumor entities throughout Europe. Early lymphonodal spread urges for aggressive therapeutic approaches in advanced tumor stages. Therefore, understanding tumor biology and its microenvironment and correlation with known survival data is of substantial interest in order to establish treatment strategies adapted to the individual patient. Fifty-five therapy naïve squamous cell carcinomas, age range between 41 and 85 years with known clinicopathological data, were investigated with the use of tissue microarrays (TMA) regarding the tumor-associated immune cell infiltrate density (ICID). Slides were stained with antibodies against CD3, CD8 and CD20. An image analysis software was applied for evaluation. Data were correlated with clinicopathological characteristics and overall survival. There was a significant increase of ICID in squamous cell carcinomas of the penis in relation to tumor adjacent physiological tissue. Higher CD3-positive ICID was significantly associated with lower tumor stage in our cohort. The ICID was not associated with overall survival. Our data sharpens the view on tumor-associated immune cell infiltrate in penile squamous cell carcinomas with an unbiased digital and automated cell count. Further investigations on the immune cell infiltrate and its prognostic and possible therapeutic impact are needed.
Treatment response lowers tumor symptom burden in recurrent and/or metastatic head and neck cancer
(2020)
Background: Head and neck squamous cell cancer (HNSCC) frequently causes severe symptoms that may be reduced, when the tumor is successfully treated. The SOCCER trial studied the association of treatment response with patient reported tumor symptom burden in first line treatment of recurrent and/or metastatic HNSCC.
Methods: In this prospective, multi-center, non-interventional trial patients were treated either with platinum-based chemotherapy and cetuximab or radiotherapy and cetuximab. Tumor symptom burden was assessed every four weeks with a questionnaire containing ten visual analogue scales (VAS, range 0–100), which were summarized to the overall VAS score.
Results: Fourhundred seventy patients were registered in 97 German centers. A total of 315 patients with at least the baseline and one subsequent questionnaire were available for analysis. Changes in the VAS score were rated as absolute differences from baseline. Negative values indicate improvement of symptoms. The overall VAS score improved significantly at the first post-baseline assessment in responders (− 2.13 vs. non-responders + 1.15, p = 0.048), and even more for the best post-baseline assessment (− 7.82 vs. non-responders − 1.97, p = 0.0005). The VAS for pain (− 16.37 vs. non-responders − 8.89, p = 0.001) and swallowing of solid food (− 16.67 vs. non-responders − 5.06, p = 0.002) improved significantly more in responders (best post-baseline assessment). In the multivariable Cox regression analysis, worse overall VAS scores were associated with worse overall survival (hazard ratio for death 1.12 per 10 points increment on the overall VAS scale, 95% CI 1.05–1.20, p = 0.0009).
Conclusion: In unselected patients beyond randomized controlled trials, treatment response lowers tumor symptom burden in recurrent and/or metastatic HNSCC.
Trial registration: ClinicalTrials.gov, NCT00122460. Registered 22 Juli 2005,
The inclusive charged particle transverse momentum distribution is measured in proton–proton collisions at s=900 GeV at the LHC using the ALICE detector. The measurement is performed in the central pseudorapidity region (|η|<0.8) over the transverse momentum range 0.15<pT<10 GeV/c. The correlation between transverse momentum and particle multiplicity is also studied. Results are presented for inelastic (INEL) and non-single-diffractive (NSD) events. The average transverse momentum for |η|<0.8 is 〈pT〉INEL=0.483±0.001 (stat.)±0.007 (syst.) GeV/c and 〈pT〉NSD=0.489±0.001 (stat.)±0.007 (syst.) GeV/c, respectively. The data exhibit a slightly larger 〈pT〉 than measurements in wider pseudorapidity intervals. The results are compared to simulations with the Monte Carlo event generators PYTHIA and PHOJET.
This study presents comprehensive real-world data on the use of anti-human epidermal growth factor receptor 2 (HER2) therapies in patients with HER2-positive metastatic breast cancer (MBC). Specifically, it describes therapy patterns with trastuzumab (H), pertuzumab + trastuzumab (PH), lapatinib (L), and trastuzumab emtansine (T-DM1). The PRAEGNANT study is a real-time, real-world registry for MBC patients. All therapy lines are documented. This analysis describes the utilization of anti-HER2 therapies as well as therapy sequences. Among 1936 patients in PRAEGNANT, 451 were HER2-positive (23.3%). In the analysis set (417 patients), 53% of whom were included in PRAEGNANT in the first-line setting, 241 were treated with H, 237 with PH, 85 with L, and 125 with T-DM1 during the course of their therapies. The sequence PH → T-DM1 was administered in 51 patients. Higher Eastern Cooperative Oncology Group (ECOG) scores, negative hormone receptor status, and visceral or brain metastases were associated with more frequent use of this therapy sequence. Most patients received T-DM1 after treatment with pertuzumab. Both novel therapies (PH and T-DM1) are utilized in a high proportion of HER2-positive breast cancer patients. As most patients receive T-DM1 after PH, real-world data may help to clarify whether the efficacy of this sequence is similar to that in the approval study.
Background: Routine human papillomavirus (HPV) testing is performed in cervival cancer and is required for classification of some head and neck cancers. In penile cancer a statement on HPV association of the carcinoma is required. In most cases p16 immunohistochemistry as a surrogate marker is applied in this setting. Since differing clinical outcomes for HPV positive and HPV negative tumors are described we await HPV testing to be requested more frequently by clinicians, also in the context of HPV vaccination, where other HPV subtypes are expected to emerge.
Method: Therefore, a cohort of archived, formalin-fixed paraffin embedded (FFPE) penile neoplasias was stained for p16 and thereafter tested for HPV infection status via PCR based methods. Additionally to Sanger sequencing, we chose LCD-Array technique (HPV 3.5 LCD-Array Kit, Chipron; LCD-Array) for the detection of HPV in our probes expecting a less time consuming and sensitive HPV test for our probes.
Results: We found that LCD-Array is a sensitive and feasible method for HPV testing in routine diagnostics applicable to FFPE material in our cohort. Our cohort of penile carcinomas and carcinomas in situ was associated with HPV infection in 61% of cases. We detected no significant association between HPV infection status and histomorphological tumor characteristics as well as overall survival.
Conclusions: We showed usability of molecular HPV testing on a cohort of archived penile carcinomas. To the best of our knowledge, this is the first study investigating LCD-Array technique on a cohort of penile neoplasias.