Refine
Year of publication
Language
- English (85)
Has Fulltext
- yes (85)
Is part of the Bibliography
- no (85)
Keywords
- LHC (7)
- ALICE (3)
- ALICE experiment (3)
- Hadron-Hadron Scattering (3)
- pp collisions (3)
- Atmospheric science (2)
- Beauty production (2)
- Climate change (2)
- Single electrons (2)
- 900 GeV (1)
- Atmospheric chemistry (1)
- CVID (1)
- Charm physics (1)
- Comparison with QCD (1)
- European Society for Immunodeficiencies (ESID) (1)
- Femtoscopy (1)
- German PID-NET registry (1)
- HBT (1)
- Hadron production (1)
- Heavy flavor production (1)
- Heavy flavour production (1)
- Heavy ions (1)
- Heavy-flavour production (1)
- Heavy-ion collisions (1)
- IgG substitution therapy (1)
- Inclusive spectra (1)
- Intensity interferometry (1)
- Mid-rapidity (1)
- Multi-strange baryons (1)
- Nuclear modification factor (1)
- PID prevalence (1)
- PYTHIA (1)
- Pb–Pb (1)
- Proton–proton (1)
- Relativistic heavy ion physics (1)
- Single muons (1)
- Transverse momentum (1)
- primary immunodeficiency (PID) (1)
- registry for primary immunodeficiency (1)
- spectra (1)
- √sN N = 2.76 TeV (1)
Institute
- Physik (77)
- Frankfurt Institute for Advanced Studies (FIAS) (66)
- Informatik (66)
- Medizin (4)
- Geowissenschaften / Geographie (3)
- Georg-Speyer-Haus (1)
- Geowissenschaften (1)
The pT-differential production cross section of electrons from semileptonic decays of heavy-flavor hadrons has been measured at mid-rapidity in proton-proton collisions at s√=2.76 TeV in the transverse momentum range 0.5 < pT < 12 GeV/c with the ALICE detector at the LHC. The analysis was performed using minimum bias events and events triggered by the electromagnetic calorimeter. Predictions from perturbative QCD calculations agree with the data within the theoretical and experimental uncertainties.
The differential charged jet cross sections, jet fragmentation distributions, and jet shapes are measured in minimum bias proton-proton collisions at centre-of-mass energy s√=7 TeV using the ALICE detector at the LHC. Jets are reconstructed from charged particle momenta in the mid-rapidity region using the sequential recombination kT and anti-kT as well as the SISCone jet finding algorithms with several resolution parameters in the range R=0.2 to 0.6. Differential jet production cross sections measured with the three jet finders are in agreement in the transverse momentum (pT) interval 20<pjet,chT<100 GeV/c. They are also consistent with prior measurements carried out at the LHC by the ATLAS collaboration. The jet charged particle multiplicity rises monotonically with increasing jet pT, in qualitative agreement with prior observations at lower energies. The transverse profiles of leading jets are investigated using radial momentum density distributions as well as distributions of the average radius containing 80% (⟨R80⟩) of the reconstructed jet pT. The fragmentation of leading jets with R=0.4 using scaled pT spectra of the jet constituents is studied. The measurements are compared to model calculations from event generators (PYTHIA, PHOJET, HERWIG). The measured radial density distributions and ⟨R80⟩ distributions are well described by the PYTHIA model (tune Perugia-2011). The fragmentation distributions are better described by HERWIG.
Long-range angular correlations on the near and away side in p–Pb collisions at √sNN=5.02 TeV
(2013)
Angular correlations between charged trigger and associated particles are measured by the ALICE detector in p–Pb collisions at a nucleon–nucleon centre-of-mass energy of 5.02 TeV for transverse momentum ranges within 0.5<pT,assoc<pT,trig<4 GeV/c. The correlations are measured over two units of pseudorapidity and full azimuthal angle in different intervals of event multiplicity, and expressed as associated yield per trigger particle. Two long-range ridge-like structures, one on the near side and one on the away side, are observed when the per-trigger yield obtained in low-multiplicity events is subtracted from the one in high-multiplicity events. The excess on the near-side is qualitatively similar to that recently reported by the CMS Collaboration, while the excess on the away-side is reported for the first time. The two-ridge structure projected onto azimuthal angle is quantified with the second and third Fourier coefficients as well as by near-side and away-side yields and widths. The yields on the near side and on the away side are equal within the uncertainties for all studied event multiplicity and pT bins, and the widths show no significant evolution with event multiplicity or pT. These findings suggest that the near-side ridge is accompanied by an essentially identical away-side ridge.
Background The effect of additional treatment strategies with antineoplastic agents on intraperitoneal tumor stimulating interleukin levels are unclear. Taurolidine and Povidone-iodine have been mainly used for abdominal lavage in Germany and Europe. Methods In the settings of a multicentre (three University Hospitals) prospective randomized controlled trial 120 patients were randomly allocated to receive either 0.5% taurolidine/2,500 IU heparin (TRD) or 0.25% povidone-iodine (control) intraperitoneally for resectable colorectal, gastric or pancreatic cancers. Due to the fact that IL-1beta (produced by macrophages) is preoperatively indifferent in various gastrointestinal cancer types our major outcome criterion was the perioperative (overall) level of IL-1beta in peritoneal fluid. Results Cytokine values were significantly lower after TRD lavage for IL-1beta, IL-6, and IL-10. Perioperative complications did not differ. The median follow-up was 50.0 months. The overall mortality rate (28 vs. 25, p = 0.36), the cancer-related death rate (17 vs. 19, p = .2), the local recurrence rate (7 vs. 12, p = .16), the distant metastasis rate (13 vs. 18, p = 0.2) as well as the time to relapse were not statistically significant different. Conclusion Reduced cytokine levels might explain a short term antitumorigenic intraperitoneal effect of TRD. But, this study analyzed different types of cancer. Therefore, we set up a multicentre randomized trial in patients undergoing curative colorectal cancer resection. Trial registration : ISRCTN66478538
Introduction: Clinically complex patients often require multiple medications. Polypharmacy is associated with inappropriate prescriptions, which may lead to negative outcomes. Few effective tools are available to help physicians optimise patient medication. This study assesses whether an electronic medication management support system (eMMa) reduces hospitalisation and mortality and improves prescription quality/safety in patients with polypharmacy. Methods and analysis: Planned design: pragmatic, parallel cluster-randomised controlled trial; general practices as randomisation unit; patients as analysis unit. As practice recruitment was poor, we included additional data to our primary endpoint analysis for practices and quarters from October 2017 to March 2021. Since randomisation was performed in waves, final study design corresponds to a stepped-wedge design with open cohort and step-length of one quarter. Scope: general practices, Westphalia-Lippe (Germany), caring for BARMER health fund-covered patients. Population: patients (≥18 years) with polypharmacy (≥5 prescriptions). Sample size: initially, 32 patients from each of 539 practices were required for each study arm (17 200 patients/arm), but only 688 practices were randomised after 2 years of recruitment. Design change ensures that 80% power is nonetheless achieved. Intervention: complex intervention eMMa. Follow-up: at least five quarters/cluster (practice). recruitment: practices recruited/randomised at different times; after follow-up, control group practices may access eMMa. Outcomes: primary endpoint is all-cause mortality and hospitalisation; secondary endpoints are number of potentially inappropriate medications, cause-specific hospitalisation preceded by high-risk prescribing and medication underuse. Statistical analysis: primary and secondary outcomes are measured quarterly at patient level. A generalised linear mixed-effect model and repeated patient measurements are used to consider patient clusters within practices. Time and intervention group are considered fixed factors; variation between practices and patients is fitted as random effects. Intention-to-treat principle is used to analyse primary and key secondary endpoints.