This article demonstrates the use of guided elastic waves (GEW) for multiple-in and multiple-out (MIMO) data communication in the framework of a structural health monitoring (SHM) system. Therefore, miniaturized low-voltage communication nodes have been developed. They are arranged in a spatially distributed and permanently installed network. Wireless exchange of encoded information across a metallic plate and a stiffened carbon-fiber reinforced plastics (CFRP) structure is investigated. A combination of square-wave excitation sequences and frequency-division multiplexing (FDM) is explored for parallel communication with multiple nodes. Moreover, the impact of the excitation-sequence length on the reliability of information transmission is studied in view of future energy-aware application scenarios. The presented system achieves in both studied structures error-free transmission at a data rate of 0.17 kbps (per carrier frequency) with a power consumption of 224 mW.
The third dataset dedicated to the Open Guided Waves platform aims at carbon fiber composite plates with an additional omega stringer at constant temperature conditions. The two structures used in this work are representative for real aircraft components. Comprehensive measurements were recorded in order to study (I) the impact of the omega stringer on guided wave propagation, and (II) elliptical reference damages of different sizes located at three separate positions on the structure. Measurements were recorded for narrowband excitation (5-cycle toneburst with varying carrier frequencies) and broadband excitation (using chirp waveforms). The paper presents the results of a technical validation including numerical modelling, and enables further research, for example related to probability of detection (POD) analysis.
The influence of temperature is regarded as particularly important for a structural health monitoring system based on ultrasonic guided waves. Since the temperature effect causes stronger signal changes than a typical defect, the former must be addressed and compensated for reliable damage assessment. Development of new temperature compensation techniques as well as the comparison of existing algorithms require high-quality benchmark measurements. This paper investigates a carbon fiber reinforced plastic (CFRP) plate that was fully characterized in previous research in terms of stiffness tensor and guided wave propagation. The same CFRP plate is used here for the analysis of the temperature effect for a wide range of ultrasound frequencies and temperatures. The measurement data are a contribution to the Open Guided Waves (OGW) platform: http://www.open-guided-waves.de. The technical validation includes initial results on the analysis of phase velocity variations with temperature and exemplary damage detection results using state-of-the-art signal processing methods that aim to suppress the temperature effect.
Sparse sensor networks for Lamb wave-based structural health monitoring (SHM) can detect defects in plate-like structures. However, the limited number of sensor positions provides little information to characterize the unknown scatterer. This can be achieved by full wavefield analysis e.g. using Laser Doppler vibrometry measurements.
This paper proposes deconvolution processing that enhances the acoustic wavefield interpretation by increasing the temporal resolution of the underlying ultrasound signals. Applying this preprocessor to the whole wavefield allows improved non-destructive assessment of the defect. This approach is verified experimentally through a case study on an isotropic aluminum plate with four cracks.