Refine
Year of publication
Document Type
- Preprint (668)
- Article (468)
- Book (2)
- Conference Proceeding (1)
- Working Paper (1)
Has Fulltext
- yes (1140)
Is part of the Bibliography
- no (1140)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron Scattering (11)
- Hadron-Hadron scattering (experiments) (11)
- LHC (8)
- Heavy-ion collision (6)
- ALICE experiment (4)
- COVID-19 (4)
- Collective Flow (4)
- Jets (4)
- Quark-Gluon Plasma (4)
Institute
- Physik (1035)
- Frankfurt Institute for Advanced Studies (FIAS) (954)
- Informatik (920)
- Medizin (69)
- Geowissenschaften (11)
- Biowissenschaften (5)
- Institut für Ökologie, Evolution und Diversität (4)
- Biochemie, Chemie und Pharmazie (3)
- Informatik und Mathematik (3)
- Hochschulrechenzentrum (2)
As part of the CLACE-6 campaign we performed size-resolved CCN measurements for a~supersaturation range of S = 0.079 % to 0.66% at the high-alpine research station Jungfraujoch, Switzerland, in March~2007. The derived effective hygroscopicity parameter κ describing the influence of particle composition on CCN activity was on average 0.23–0.30 for Aitken (50–100 nm) and 0.32–0.43 for accumulation mode particles (100–200 nm). The campaign average value of κ = 0.3 is similar to the average value of κ for other continental locations. When air masses came from southeasterly directions crossing the Po Valley in Italy, particles were much more hygroscopic (κ ≈ 0.42) due to large sulfate mass fractions. The κ values obtained at S = 0.079 % exhibited a good negative correlation with the organic mass fractions derived from PM1 aerosol mass spectrometer (AMS) measurements. Applying a simple mixing rule the organic and inorganic mass fractions observed by the AMS could be used to reproduce the temporal fluctuations of the hygroscopicity of accumulation mode particles quite well.
We show how during a cloud event the aerosol particles were activated as cloud droplets and then removed from the air by precipitation leaving behind only a small amount of accumulation mode particles consisting mainly of weakly CCN-active particles, most likely externally mixed unprocessed soot particles.
During the campaign we had the opportunity to directly compare two DMT CCN counters for a certain time. The total CCN concentration (NCCN,tot) obtained by the two instruments at equal supersaturations agreed well for both possible operating modes: detecting NCCN,tot directly by sampling the polydisperse aerosol with the CCNC, or indirectly by combining size-resolved measurements of the activated fraction with parallel measurements of the particle size distribution (e.g., by SMPS). However, some supersaturation setpoints differed between the two CCNCs by as much as 20% after applying the instrument calibrations, which resulted in differences of the corresponding NCCN,tot of up to 50%. This emphasizes that it is extremely important to carefully calibrate the supersaturation of the instrument, especially at low S.
The aim of this study is to investigate the incidental prostate cancer (iPCa) detection rates of different embedding methods in a large, contemporary cohort of patients with bladder outlet obstruction (BOO) treated with transurethral surgery. We relied on an institutional tertiary-care database to identify BOO patients who underwent either transurethral loop resection or laser (Holmium:yttrium–aluminium garnet) enucleation of the prostate (HoLEP) between 01/2012 and 12/2019. Embedding methods differed with regard to the extent of the additional prostate tissue submitted following the first ten cassettes of primary embedding (cohort A: one [additional] cassette/10 g residual tissue vs. cohort B: complete embedding of the residual tissue). Detection rates of iPCa among the different embedding methods were compared. Subsequently, subgroup analyses by embedding protocol were repeated in HoLEP-treated patients only. In the overall cohort, the iPCa detection rate was 11% (46/420). In cohort A (n = 299), tissue embedding resulted in a median of 8 cassettes/patient (range 1–38) vs. a median of 15 (range 2–74) in cohort B (n = 121) (p < .001). The iPCa detection rate was 8% (23/299) and 19% (23/121) in cohort A vs. cohort B, respectively (p < .001). Virtual reduction of the number of tissue cassettes to ten cassettes resulted in a iPCa detection rate of 96% in both cohorts, missing one stage T1a/ISUP grade 1 carcinoma. Increasing the number of cassettes by two and eight cassettes, respectively, resulted in a detection rate of 100% in both cohorts without revealing high-grade carcinomas. Subgroup analyses in HoLEP patients confirmed these findings, demonstrated by a 100 vs. 96% iPCa detection rate following examination of the first ten cassettes, missing one case of T1a/ISUP 1. Examination of 8 additional cassettes resulted in a 100% detection rate. The extent of embedding of material obtained from transurethral prostate resection correlates with the iPCa detection rate. However, the submission of 10 cassettes appears to be a reasonable threshold to reduce resource utilization while maintaining secure cancer detection.
Background: Unlike metastatic colorectal cancer (CRC) there are to date few reports concerning the predictive value of molecular biomarkers on the clinical outcome in stage II/III CRC patients receiving adjuvant chemotherapy. Aim of this study was to assess the predictive value of proteins related with the EGFR- and VEGFR- signalling cascades in these patients.
Methods: The patients' data examined in this study were from the collective of the 5-FU/FA versus 5-FU/FA/irinotecan phase III FOGT-4 trial. Tumor tissues were stained by immunohistochemistry for VEGF-C, VEGF-D, VEGFR-3, Hif-1 α, PTEN, AREG and EREG expression and evaluated by two independent, blinded investigators. Survival analyses were calculated for all patients receiving adjuvant chemotherapy in relation to expression of all makers above.
Results: Patients with negative AREG and EREG expression on their tumor had a significant longer DFS in comparison to AREG/EREG positive ones (p< 0.05). The benefit on DFS in AREG-/EREG- patients was even stronger in the group that received 5-FU/FA/irinotecan as adjuvant treatment (p=0.002). Patients with strong expression of PTEN profited more in terms of OS under adjuvant treatment containing irinotecan (p< 0.05). Regarding markers of the VEGFR- pathway we found no correlation of VEGF-C- and VEGFR-3 expression with clinical outcome. Patients with negative VEGF-D expression had a trend to live longer when treated with 5-FU/FA (p=0.106). Patients who were negative for Hif-1 α, were disease-free in more than 50% at the end of the study and showed significant longer DFS-rates than those positive for Hif-1 α (p=0.007). This benefit was even stronger at the group treated with 5-FU/FA/irinotecan (p=0.026). Finally, AREG-/EREG-/PTEN+ patients showed a trend to live longer under combined treatment combination.
Conclusions: The addition of irinotecan to adjuvant treatment with 5-FU/FA does not provide OS or DFS benefit in patients with stage II/III CRC. Nevertheless, AREG/EREG negative, PTEN positive and Hif-1 α negative patients might profit significantly in terms of DFS from a treatment containing fluoropyrimidines and irinotecan. Our results suggest a predictive value of these biomarkers concerning adjuvant chemotherapy with 5-FU/FA +/− irinotecan in stage II/III colorectal cancer.
In the present work, three different techniques are used to separate ice-nucleating particles (INP) and ice particle residuals (IPR) from non-ice-active particles: the Ice Selective Inlet (ISI) and the Ice Counterflow Virtual Impactor (Ice-CVI), which sample ice particles from mixed phase clouds and allow for the analysis of the residuals, as well as the combination of the Fast Ice Nucleus Chamber (FINCH) and the Ice Nuclei Pumped Virtual Impactor (IN-PCVI), which provides ice-activating conditions to aerosol particles and extracts the activated ones for analysis. The collected particles were analyzed by scanning electron microscopy and energy-dispersive X-ray microanalysis to determine their size, chemical composition and mixing state. Samples were taken during January/February 2013 at the High Alpine Research Station Jungfraujoch. All INP/IPR-separating techniques had considerable abundances (median 20–70%) of contamination artifacts (ISI: Si-O spheres, probably calibration aerosol; Ice-CVI: Al-O particles; FINCH + IN-PCVI: steel particles). Also, potential measurement artifacts (soluble material) occurred (median abundance < 20%). After removal of the contamination particles, silicates and Ca-rich particles, carbonaceous material and metal oxides were the major INP/IPR particle types separated by all three techniques. Minor types include soot and Pb-bearing particles. Sea-salt and sulfates were identified by all three methods as INP/IPR. Lead was identified in less than 10% of the INP/IPR. It was mainly present as an internal mixture with other particle types, but also external lead-rich particles were found. Most samples showed a maximum of the INP/IPR size distribution at 400 nm geometric diameter. In a few cases, a second super-micron maximum was identified. Soot/carbonaceous material and metal oxides were present mainly in the submicron range. ISI and FINCH yielded silicates and Ca-rich particles mainly with diameters above 1 μm, while the Ice-CVI also sampled many submicron particles. Probably owing to the different meteorological conditions, the INP/IPR composition was highly variable on a sample to sample basis. Thus, some part of the discrepancies between the different techniques may result from the (unavoidable) non-parallel sampling. The observed differences of the particles group abundances as well as the mixing state of INP/IPR point to the need of further studies to better understand the influence of the separating techniques on the INP/IPR chemical composition.
During January/February 2013, at the High Alpine Research Station Jungfraujoch a measurement campaign was carried out, which was centered on atmospheric ice-nucleating particles (INP) and ice particle residuals (IPR). Three different techniques for separation of INP and IPR from the non-ice-active particles are compared. The Ice Selective Inlet (ISI) and the Ice Counterflow Virtual Impactor (Ice-CVI) sample ice particles from mixed phase clouds and allow for the analysis of the residuals. The combination of the Fast Ice Nucleus Chamber (FINCH) and the Ice Nuclei Pumped Counterflow Virtual Impactor (IN-PCVI) provides ice-activating conditions to aerosol particles and extracts the activated INP for analysis.Collected particles were analyzed by scanning electron microscopy and energy-dispersive X-ray microanalysis to determine size, chemical composition and mixing state. All INP/IPR-separating techniques had considerable abundances (median 20 – 70 %) of instrumental contamination artifacts (ISI: Si-O spheres, probably calibration aerosol; Ice-CVI: Al-O particles; FINCH+IN-PCVI: steel particles). Also, potential sampling artifacts (e.g., pure soluble material) occurred with a median abundance of < 20 %. While these could be explained as IPR by ice break-up, for INP their IN-ability pathway is less clear. After removal of the contamination artifacts, silicates and Ca-rich particles, carbonaceous material and metal oxides were the major INP/IPR particle types separated by all three techniques. Soot was a minor contributor. Lead was detected in less than 10 % of the particles, of which the majority were internal mixtures with other particle types. Sea-salt and sulfates were identified by all three methods as INP/IPR. Most samples showed a maximum of the INP/IPR size distribution at 400 nm geometric diameter. In a few cases, a second super-micron maximum was identified. Soot/carbonaceous material and metal oxides were present mainly in the submicron range. ISI and FINCH yielded silicates and Ca-rich particles mainly with diameters above 1 μm, while the Ice-CVI also separated many submicron IPR. As strictly parallel sampling could not be performed, a part of the discrepancies between the different techniques may result from variations in meteorological conditions and subsequent INP/IPR composition. The observed differences in the particle group abundances as well as in the mixing state of INP/IPR express the need for further studies to better understand the influence of the separating techniques on the INP/IPR chemical
composition.
Background: To test the value of immunohistochemistry (IHC) staining in prostate biopsies for changes in biopsy results and its impact on treatment decision-making. Methods: Between January 2017–June 2020, all patients undergoing prostate biopsies were identified and evaluated regarding additional IHC staining for diagnostic purpose. Final pathologic results after radical prostatectomy (RP) were analyzed regarding the effect of IHC at biopsy. Results: Of 606 biopsies, 350 (58.7%) received additional IHC staining. Of those, prostate cancer (PCa) was found in 208 patients (59.4%); while in 142 patients (40.6%), PCa could be ruled out through IHC. IHC patients harbored significantly more often Gleason 6 in biopsy (p < 0.01) and less suspicious baseline characteristics than patients without IHC. Of 185 patients with positive IHC and PCa detection, IHC led to a change in biopsy results in 81 (43.8%) patients. Of these patients with changes in biopsy results due to IHC, 42 (51.9%) underwent RP with 59.5% harboring ≥pT3 and/or Gleason 7–10. Conclusions: Patients with IHC stains had less suspicious characteristics than patients without IHC. Moreover, in patients with positive IHC and PCa detection, a change in biopsy results was observed in >40%. Patients with changes in biopsy results partly underwent RP, in which 60% harbored significant PCa.
Background: The impact of MRI-lesion targeted (TB) and systematic biopsy (SB) Gleason score (GS) as a predictor for final pathological GS still remains unclear. Methods: All patients with TB + SB, and subsequent radical prostatectomy (RP) between 01/2014-12/2020 were analyzed. Rank correlation coefficient predicted concordance with pathological GS for patients’ TB and SB GS, as well as for the combined effect of SB + TB. Results: Of 159 eligible patients, 77% were biopsy naïve. For SB taken in addition to TB, a Spearman’s correlation of +0.33 was observed regarding final GS. Rates of concordance, upgrading, and downgrading were 37.1, 37.1 and 25.8%, respectively. For TB, a +0.52 correlation was computed regarding final GS. Rates of concordance, upgrading and downgrading for TB biopsy GS were 45.9, 33.3, and 20.8%, respectively. For the combination of SB + TB, a correlation of +0.59 was observed. Rates of concordance, upgrading and downgrading were 49.7, 15.1 and 35.2%, respectively. The combined effect of SB + TB resulted in a lower upgrading rate, relative to TB and SB (both p < 0.001), but a higher downgrading rate, relative to TB (p < 0.01). Conclusions: GS obtained from TB provided higher concordance and lower upgrading and downgrading rates, relative to SB GS with regard to final pathology. The combined effect of SB + TB led to the highest concordance rate and the lowest upgrading rate.
Ecological speciation assumes reproductive isolation to be the product of ecologically based divergent selection. Beside natural selection, sexual selection via phenotype-assortative mating is thought to promote reproductive isolation. Using the neotropical fish Poecilia mexicana from a system that has been described to undergo incipient ecological speciation in adjacent, but ecologically divergent habitats characterized by the presence or absence of toxic H2S and darkness in cave habitats, we demonstrate a gradual change in male body colouration along the gradient of light/darkness, including a reduction of ornaments that are under both inter- and intrasexual selection in surface populations. In dichotomous choice tests using video-animated stimuli, we found surface females to prefer males from their own population over the cave phenotype. However, female cave fish, observed on site via infrared techniques, preferred to associate with surface males rather than size-matched cave males, likely reflecting the female preference for better-nourished (in this case: surface) males. Hence, divergent selection on body colouration indeed translates into phenotype-assortative mating in the surface ecotype, by selecting against potential migrant males. Female cave fish, by contrast, do not have a preference for the resident male phenotype, identifying natural selection against migrants imposed by the cave environment as the major driver of the observed reproductive isolation.
Background: The ERGO2 (Ernaehrungsumstellung bei Patienten mit Rezidiv eines Glioblastoms) MR-spectroscopic imaging (MRSI) subtrial investigated metabolism in patients randomized to calorically restricted ketogenic diet/intermittent fasting (crKD-IF) versus standard diet (SD) in addition to re-irradiation (RT) for recurrent malignant glioma. Intracerebral concentrations of ketone bodies (KB), intracellular pH (pHi), and adenosine triphosphate (ATP) were non-invasively determined. Methods: 50 patients were randomized (1:1): Group A keeping a crKD-IF for nine days, and Group B a SD. RT was performed on day 4-8. Twenty-three patients received an extended MRSI-protocol (1H decoupled 31P MRSI with 3D chemical shift imaging (CSI) and 2D 1H point-resolved spectroscopy (PRESS)) at a 3T scanner at baseline and on day 6. Voxels were selected from the area of recurrent tumor and contralateral hemisphere. Spectra were analyzed with LCModel, adding simulated signals of 3-hydroxybutyrate (βOHB), acetone (Acn) and acetoacetate (AcAc) to the standard basis set. Results: Acn was the only reliably MRSI-detectable KB within tumor tissue and/or normal appearing white matter (NAWM). It was detected in 4/11 patients in Group A and in 0/8 patients in Group B. MRSI results showed no significant depletion of ATP in tumor tissue of patients at day 6 during crKD-IF, even though there were a significant difference in ketone serum levels between Group A and B at day 6 and a decline in fasting glucose in Group A from baseline to day 6. The tumor specific alkaline pHi was maintained. Conclusions: Our metabolic findings suggest that tumor cells maintain energy homeostasis even with reduced serum glucose levels and may generate additional ATP through other sources.r sources.
The Sleeping Beauty (SB) transposon system is a non-viral gene delivery platform that combines simplicity, inexpensive manufacture, and favorable safety features in the context of human applications. However, efficient correction of hematopoietic stem and progenitor cells (HSPCs) with non-viral vector systems, including SB, demands further refinement of gene delivery techniques. We set out to improve SB gene transfer into hard-to-transfect human CD34+ cells by vectorizing the SB system components in the form of minicircles that are devoid of plasmid backbone sequences and are, therefore, significantly reduced in size. As compared to conventional plasmids, delivery of the SB transposon system as minicircle DNA is ∼20 times more efficient, and it is associated with up to a 50% reduction in cellular toxicity in human CD34+ cells. Moreover, providing the SB transposase in the form of synthetic mRNA enabled us to further increase the efficacy and biosafety of stable gene delivery into hematopoietic progenitors ex vivo. Genome-wide insertion site profiling revealed a close-to-random distribution of SB transposon integrants, which is characteristically different from gammaretroviral and lentiviral integrations in HSPCs. Transplantation of gene-marked CD34+ cells in immunodeficient mice resulted in long-term engraftment and hematopoietic reconstitution, which was most efficient when the SB transposase was supplied as mRNA and nucleofected cells were maintained for 4–8 days in culture before transplantation. Collectively, implementation of minicircle and mRNA technologies allowed us to further refine the SB transposon system in the context of HSPC gene delivery to ultimately meet clinical demands of an efficient and safe non-viral gene therapy protocol.