Refine
Year of publication
Document Type
- Article (134)
- Preprint (95)
- Working Paper (2)
Has Fulltext
- yes (231)
Is part of the Bibliography
- no (231)
Keywords
- BESIII (15)
- Branching fraction (9)
- e +-e − Experiments (9)
- Hadronic decays (5)
- Particle and Resonance Production (5)
- Branching fractions (4)
- Lepton colliders (4)
- Quarkonium (4)
- Charm Physics (3)
- Charmed mesons (3)
- Charmonium (3)
- Electroweak interaction (3)
- Exotics (3)
- Initial state radiation (3)
- Spectroscopy (3)
- e+-e− Experiments (3)
- Arbeitsangebot (2)
- Arbeitsloser (2)
- Arbeitslosigkeit (2)
- Berufserfolg (2)
- Bhabha (2)
- Charm physics (2)
- Cross section (2)
- Deutschland (2)
- Diagnostik (2)
- Electroweak Interaction (2)
- Früherkennung (2)
- Geschichte 1975-1994 (2)
- Geschlecht (2)
- Großbritannien (2)
- Hadronic cross section (2)
- Karriere (2)
- Leptonic, semileptonic & radiative decays (2)
- Mammakarzinom (2)
- Muon anomaly (2)
- Nachsorge (2)
- Particle decays (2)
- Pion form factor (2)
- QCD (2)
- Richtlinie (2)
- Schweden (2)
- Sozialstaat (2)
- Sozialstaatsprinzip (2)
- breast cancer (2)
- diagnosis (2)
- follow‑up (2)
- guideline (2)
- screening (2)
- Angular distribution (1)
- Annihilation (1)
- Anti-kaon–nucleon physics (1)
- BESIII detector (1)
- Born cross section measurement (1)
- CP violation (1)
- Charmonium (-like) (1)
- Covariance matrix (1)
- Cross section measurements (1)
- D meson (1)
- D0 and D+ mesons (1)
- DAISIE (1)
- Dalitz decay (1)
- Dark photon (1)
- Dark sector (1)
- Diagnostic differentiation (1)
- D⁰ meson (1)
- Electromagnetic amplitude (1)
- Electromagnetic form factor (1)
- Electromagnetic form factors (1)
- Electron-pion identification (1)
- Europe (1)
- Experimental nuclear physics (1)
- Experimental particle physics (1)
- FOS: Physical sciences (1)
- Fibre/foam sandwich radiator (1)
- Flavor changing neutral currents (1)
- Flavor symmetries (1)
- Flavour Physics (1)
- Form factors (1)
- Gadobutrol (1)
- Gadopentate dimeglumine (1)
- Hadrons (1)
- High Energy Physics - Experiment (hep-ex) (1)
- Hyperons (1)
- Invisible decays (1)
- Ionisation energy loss (1)
- Kaonic nuclei (1)
- Low energy QCD (1)
- MRI (1)
- Multi-wire proportional drift chamber (1)
- NeoBiota (1)
- Neural network (1)
- Neutrinos (1)
- Noninferiority (1)
- Partial wave analysis (1)
- Particle and resonance production (1)
- Particle phenomena (1)
- Phase (1)
- Polarization (1)
- Proton (1)
- Quantum chromodynamics (1)
- R value (1)
- Radiative decay (1)
- Rare decays (1)
- Renal lesions (1)
- Semi-leptonic decays (1)
- Strong amplitude (1)
- TR (1)
- Techniques Electromagnetic calorimeters (1)
- Tracking (1)
- Transition radiation detector (1)
- Trigger (1)
- Triple quarkonia (1)
- Xenon-based gas mixture (1)
- Y (4260) (1)
- Y states (1)
- alien species (1)
- branching fractions (1)
- center-of-mass energy (1)
- charmed baryon (1)
- charmonium-like states (1)
- dE/dx (1)
- data publishing (1)
- decay (1)
- decays (1)
- dimuon (1)
- diphoton (1)
- e+e − annihilation (1)
- e+e⁻ − Experiments (1)
- e+e− Experiments (1)
- e+e− annihilation (1)
- ecological impact (1)
- electron-positron collision (1)
- fish (1)
- hadron spectroscopy (1)
- hadronic events (1)
- helicity amplitude analysis (1)
- inclusive J/ψ decays (1)
- introductions (1)
- invasion biology (1)
- invertebrates (1)
- luminosity (1)
- mammals (1)
- number of J/ψ events (1)
- pathways (1)
- plants (1)
- ppK − (1)
- semantic enhancements (1)
- semantic markup (1)
- tetraquark (1)
- trigger efficiency (1)
- Λ+c baryon (1)
- Σ hyperon (1)
Institute
- Physik (224)
- Frankfurt Institute for Advanced Studies (FIAS) (6)
- Informatik (6)
- Medizin (3)
- Wirtschaftswissenschaften (2)
The purpose of this phase III clinical trial was to compare two different extracellular contrast agents, 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine, for magnetic resonance imaging (MRI) in patients with known or suspected focal renal lesions. Using a multicenter, single-blind, interindividual, randomized study design, both contrast agents were compared in a total of 471 patients regarding their diagnostic accuracy, sensitivity, and specificity to correctly classify focal lesions of the kidney. To test for noninferiority the diagnostic accuracy rates for both contrast agents were compared with CT results based on a blinded reading. The average diagnostic accuracy across the three blinded readers (‘average reader’) was 83.7% for gadobutrol and 87.3% for gadopentate dimeglumine. The increase in accuracy from precontrast to combined precontrast and postcontrast MRI was 8.0% for gadobutrol and 6.9% for gadopentate dimeglumine. Sensitivity of the average reader was 85.2% for gadobutrol and 88.7% for gadopentate dimeglumine. Specificity of the average reader was 82.1% for gadobutrol and 86.1% for gadopentate dimeglumine. In conclusion, this study documents evidence for the noninferiority of a single i.v. bolus injection of 1.0 M gadobutrol compared with 0.5 M gadopentate dimeglumine in the diagnostic assessment of renal lesions with CE-MRI.
Ziele: Das Ziel dieser offiziellen Leitlinie, die von der Deutschen Gesellschaft für Gynäkologie und Geburtshilfe (DGGG) und der Deutschen Krebsgesellschaft (DKG) publiziert und koordiniert wurde, ist es, die Früherkennung, Diagnostik, Therapie und Nachsorge des Mammakarzinoms zu optimieren.
Methoden: Der Aktualisierungsprozess der S3-Leitlinie aus 2012 basierte zum einen auf der Adaptation identifizierter Quellleitlinien und zum anderen auf Evidenzübersichten, die nach Entwicklung von PICO-(Patients/Interventions/Control/Outcome-)Fragen, systematischer Recherche in Literaturdatenbanken sowie Selektion und Bewertung der gefundenen Literatur angefertigt wurden. In den interdisziplinären Arbeitsgruppen wurden auf dieser Grundlage Vorschläge für Empfehlungen und Statements erarbeitet, die im Rahmen von strukturierten Konsensusverfahren modifiziert und graduiert wurden.
Empfehlungen: Der Teil 1 dieser Kurzversion der Leitlinie zeigt Empfehlungen zur Früherkennung, Diagnostik und Nachsorge des Mammakarzinoms: Der Stellenwert des Mammografie-Screenings wird in der aktualisierten Leitlinienversion bestätigt und bildet damit die Grundlage der Früherkennung. Neben den konventionellen Methoden der Karzinomdiagnostik wird die Computertomografie (CT) zum Staging bei höherem Rückfallrisiko empfohlen. Die Nachsorgekonzepte beinhalten Untersuchungsintervalle für die körperliche Untersuchung, Ultraschall und Mammografie, während weiterführende Gerätediagnostik und Tumormarkerbestimmungen bei der metastasierten Erkrankung Anwendung finden.
Purpose: The aim of this official guideline coordinated and published by the German Society for Gynecology and Obstetrics (DGGG) and the German Cancer Society (DKG) was to optimize the screening, diagnosis, therapy and follow-up care of breast cancer.
Methods: The process of updating the S3 guideline dating from 2012 was based on the adaptation of identified source guidelines which were combined with reviews of evidence compiled using PICO (Patients/Interventions/Control/Outcome) questions and the results of a systematic search of literature databases and the selection and evaluation of the identified literature. The interdisciplinary working groups took the identified materials as their starting point to develop recommendations and statements which were modified and graded in a structured consensus procedure.
Recommendations: Part 1 of this short version of the guideline presents recommendations for the screening, diagnosis and follow-up care of breast cancer. The importance of mammography for screening is confirmed in this updated version of the guideline and forms the basis for all screening. In addition to the conventional methods used to diagnose breast cancer, computed tomography (CT) is recommended for staging in women with a higher risk of recurrence. The follow-up concept includes suggested intervals between physical, ultrasound and mammography examinations, additional high-tech diagnostic procedures, and the determination of tumor markers for the evaluation of metastatic disease.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p–Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The first measurement of ϕ-meson production in p-Pb collisions at a nucleon-nucleon centre-of-mass energy sNN−−−√ = 5.02 TeV has been performed with the ALICE apparatus at the LHC. The ϕ-mesons have been identified in the dimuon decay channel in the transverse momentum (pT) range 1<pT<7 GeV/c, both in the p-going (2.03<y<3.53) and the Pb-going (−4.46<y<−2.96) directions, where y stands for the rapidity in the nucleon-nucleon centre-of-mass. Differential cross sections as a function of transverse momentum and rapidity are presented. The forward-backward asymmetry for ϕ-meson production is measured for 2.96<|y|<3.53, resulting in a factor ∼0.5 with no significant pT dependence within the uncertainties. The pT dependence of the ϕ nuclear modification factor RpPb exhibits an enhancement up to a factor 1.6 at pT = 3-4 GeV/c in the Pb-going direction. The pT dependence of the ϕ-meson cross section in pp collisions at s√ = 2.76 TeV, which is used to determine a reference for the p-Pb results, is also presented here for 1<pT<5 GeV/c and 2.5<y<4.
We report on results obtained with the Event Shape Engineering technique applied to Pb-Pb collisions at sNN−−−√=2.76 TeV. By selecting events in the same centrality interval, but with very different average flow, different initial state conditions can be studied. We find the effect of the event-shape selection on the elliptic flow coefficient v2 to be almost independent of transverse momentum pT, as expected if this effect is due to fluctuations in the initial geometry of the system. Charged hadron, pion, kaon, and proton transverse momentum distributions are found to be harder in events with higher-than-average elliptic flow, indicating an interplay between radial and elliptic flow.
Transverse momentum (pT) spectra of pions, kaons, and protons up to pT=20 GeV/c have been measured in Pb-Pb collisions at sNN−−−√=2.76 TeV using the ALICE detector for six different centrality classes covering 0-80%. The proton-to-pion and the kaon-to-pion ratios both show a distinct peak at pT≈3 GeV/c in central Pb-Pb collisions that decreases towards more peripheral collisions. For pT>10 GeV/c, the nuclear modification factor is found to be the same for all three particle species in each centrality interval within systematic uncertainties of 10-20%. This suggests there is no direct interplay between the energy loss in the medium and the particle species composition in the hard core of the quenched jet. For pT<10 GeV/c, the data provide important constraints for models aimed at describing the transition from soft to hard physics.
We present data on charged kaons (K±) and ϕ mesons in Au(1.23A GeV)+Au collisions. It is the first simultaneous measurement of K− and ϕ mesons in central heavy-ion collisions below a kinetic beam energy of 10A GeV. The ϕ/K− multiplicity ratio is found to be surprisingly high with a value of 0.52±0.16 and shows no dependence on the centrality of the collision. Consequently, the different slopes of the K+ and K− transverse-mass spectra can be explained solely by feed-down, which substantially softens the spectra of K− mesons. Hence, in contrast to the commonly adapted argumentation in literature, the different slopes do not necessarily imply diverging freeze-out temperatures of K+ and K− mesons caused by different couplings to baryons.
This paper reports on Monte Carlo simulation results for future measurements of the moduli of time-like proton electromagnetic form factors, |GE | and |GM|, using the ¯pp → μ+μ− reaction at PANDA (FAIR). The electromagnetic form factors are fundamental quantities parameterizing the electric and magnetic structure of hadrons. This work estimates the statistical and total accuracy with which the form factors can be measured at PANDA, using an analysis of simulated data within the PandaRoot software framework. The most crucial background channel is ¯pp → π+π−,due to the very similar behavior of muons and pions in the detector. The suppression factors are evaluated for this and all other relevant background channels at different values of antiproton beam momentum. The signal/background separation is based on a multivariate analysis, using the Boosted Decision Trees method. An expected background subtraction is included in this study, based on realistic angular distribuations of the background contribution. Systematic uncertainties are considered and the relative total uncertainties of the form factor measurements are presented.