Purpose: High precision radiosurgery demands comprehensive delivery-quality-assurance techniques. The use of a liquid-filled ion-chamber-array for robotic-radiosurgery delivery-quality-assurance was investigated and validated using several test scenarios and routine patient plans.
Methods and material: Preliminary evaluation consisted of beam profile validation and analysis of source–detector-distance and beam-incidence-angle response dependence. The delivery-quality-assurance analysis is performed in four steps: (1) Array-to-plan registration, (2) Evaluation with standard Gamma-Index criteria (local-dose-difference ⩽ 2%, distance-to-agreement ⩽ 2 mm, pass-rate ⩾ 90%), (3) Dose profile alignment and dose distribution shift until maximum pass-rate is found, and (4) Final evaluation with 1 mm distance-to-agreement criterion. Test scenarios consisted of intended phantom misalignments, dose miscalibrations, and undelivered Monitor Units. Preliminary method validation was performed on 55 clinical plans in five institutions.
Results: The 1000SRS profile measurements showed sufficient agreement compared with a microDiamond detector for all collimator sizes. The relative response changes can be up to 2.2% per 10 cm source–detector-distance change, but remains within 1% for the clinically relevant source–detector-distance range. Planned and measured dose under different beam-incidence-angles showed deviations below 1% for angles between 0° and 80°. Small-intended errors were detected by 1 mm distance-to-agreement criterion while 2 mm criteria failed to reveal some of these deviations. All analyzed delivery-quality-assurance clinical patient plans were within our tight tolerance criteria.
Conclusion: We demonstrated that a high-resolution liquid-filled ion-chamber-array can be suitable for robotic radiosurgery delivery-quality-assurance and that small errors can be detected with tight distance-to-agreement criterion. Further improvement may come from beam specific correction for incidence angle and source–detector-distance response.
Background: Photochemical internalization (PCI) is a novel technology for light-induced enhancement of the local therapeutic effect of cancer drugs, utilizing a specially designed photosensitizing molecule (fimaporfin). The photosensitizing molecules are trapped in endosomes along with macromolecules or drugs. Photoactivation of fimaporfin disrupts the endosomal membranes so that drug molecules are released from endosomes inside cells and can reach their therapeutic target in the cell cytosol or nucleus. Compared with photodynamic therapy, the main cytotoxic effect with PCI is disruption of the endosomal membrane resulting in delivery of chemotherapy drug, and not to the photochemical reactions per se. In this study we investigated the effect of PCI with gemcitabine in patients with inoperable perihilar cholangiocarcinoma (CCA).
Methods: The in vitro cytotoxic effect of PCI with gemcitabine was studied on two CCA-derived cell lines. In a fimaporfin dose-escalation phase I clinical study, we administered PCI with gemcitabine in patients with perihilar CCA (n = 16) to establish a safe and tolerable fimaporfin dose and to get early signals of efficacy. The patients enrolled in the study had tumors in which the whole length of the tumor could be illuminated from the inside of the bile duct, using an optical fiber inserted via an endoscope (Fig. 1). Fimaporfin was administered intravenously at day 0; gemcitabine (i.v.) and intraluminal biliary endoscopic laser light application on day 4; followed by standard gemcitabine/cisplatin chemotherapy.
Results: Preclinical experiments showed that PCI enhanced the effect of gemcitabine. In patients with CCA, PCI with gemcitabine was well tolerated with no dose-limiting toxicities, and no unexpected safety signals. Disease control was achieved in 10 of 11 evaluable patients, with a clearly superior effect in the two highest dose groups. The objective response rate (ORR) was 42%, including two complete responses, while ORR at the highest dose was 60%. Progression-free survival at 6 months was 75%, and median overall survival (mOS) was 15.4 months, with 22.8 months at the highest fimaporfin dose.
Conclusion: Photochemical internalization with gemcitabine was found to be safe and resulted in encouraging response and survival rates in patients with unresectable perihilar CCA.