Refine
Document Type
- Article (15)
Language
- English (15)
Has Fulltext
- yes (15)
Is part of the Bibliography
- no (15)
Keywords
- Patient blood management (4)
- Mortality (3)
- Transfusion (3)
- Blood loss estimation (2)
- Outcome (2)
- Visual estimation (2)
- anaemia (2)
- children (2)
- iron deficiency (2)
- patient blood management (2)
Institute
- Medizin (15)
Background: Extracorporeal life support (ECLS) has become an integral part of modern intensive therapy. The choice of support mode depends largely on the indication. Patients with respiratory failure are predominantly treated with a venovenous (VV) approach. We hypothesized that mortality in Germany in ECLS therapy did not differ from previously reported literature
Methods: Inpatient data from Germany from 2007 to 2018 provided by the Federal Statistical Office of Germany were analysed. The international statistical classification of diseases and related health problems codes (ICD) and process keys (OPS) for extracorporeal membrane oxygenation (ECMO) types, acute respiratory distress syndrome (ARDS) and hospital mortality were used.
Results: In total, 45,647 hospitalized patients treated with ECLS were analysed. In Germany, 231 hospitals provided ECLS therapy, with a median of 4 VV-ECMO and 9 VA-ECMO in 2018. Overall hospital mortality remained higher than predicted in comparison to the values reported in the literature. The number of VV-ECMO cases increased by 236% from 825 in 2007 to 2768 in 2018. ARDS was the main indication for VV-ECMO in only 33% of the patients in the past, but that proportion increased to 60% in 2018. VA-ECMO support is of minor importance in the treatment of ARDS in Germany. The age distribution of patients undergoing ECLS has shifted towards an older population. In 2018, the hospital mortality decreased in VV-ECMO patients and VV-ECMO patients with ARDS to 53.9% (n = 1493) and 54.4% (n = 926), respectively.
Conclusions: ARDS is a severe disease with a high mortality rate despite ECLS therapy. Although endpoints and timing of the evaluations differed from those of the CESAR and EOLIA studies and the Extracorporeal Life Support Organization (ELSO) Registry, the reported mortality in these studies was lower than in the present analysis. Further prospective analyses are necessary to evaluate outcomes in ECMO therapy at the centre volume level.
Estimating intraoperative blood loss is one of the daily challenges for clinicians. Despite the knowledge of the inaccuracy of visual estimation by anaesthetists and surgeons, this is still the mainstay to estimate surgical blood loss. This review aims at highlighting the strengths and weaknesses of currently used measurement methods. A systematic review of studies on estimation of blood loss was carried out. Studies were included investigating the accuracy of techniques for quantifying blood loss in vivo and in vitro. We excluded nonhuman trials and studies using only monitoring parameters to estimate blood loss. A meta-analysis was performed to evaluate systematic measurement errors of the different methods. Only studies that were compared with a validated reference e.g. Haemoglobin extraction assay were included. 90 studies met the inclusion criteria for systematic review and were analyzed. Six studies were included in the meta-analysis, as only these were conducted with a validated reference. The mixed effect meta-analysis showed the highest correlation to the reference for colorimetric methods (0.93 95% CI 0.91–0.96), followed by gravimetric (0.77 95% CI 0.61–0.93) and finally visual methods (0.61 95% CI 0.40–0.82). The bias for estimated blood loss (ml) was lowest for colorimetric methods (57.59 95% CI 23.88–91.3) compared to the reference, followed by gravimetric (326.36 95% CI 201.65–450.86) and visual methods (456.51 95% CI 395.19–517.83). Of the many studies included, only a few were compared with a validated reference. The majority of the studies chose known imprecise procedures as the method of comparison. Colorimetric methods offer the highest degree of accuracy in blood loss estimation. Systems that use colorimetric techniques have a significant advantage in the real-time assessment of blood loss.
Background: The most common technique used worldwide to quantify blood loss during an operation is the visual assessment by the attending intervention team. In every operating room you will find scaled suction canisters that collect fluids from the surgical field. This scaling is commonly used by clinicians for visual assessment of intraoperative blood loss. While many studies have been conducted to quantify and improve the inaccuracy of the visual estimation method, research has focused on the estimation of blood volume in surgical drapes. The question whether and how scaling of canisters correlates with actual blood loss and how accurately clinicians estimate blood loss in scaled canisters has not been the focus of research to date.
Methods: A simulation study with four “bleeding” scenarios was conducted using expired whole blood donations. After diluting the blood donations with full electrolyte solution, the sample blood loss volume (SBL) was transferred into suction canisters. The study participants then had to estimate the blood loss in all four scenarios. The difference to the reference blood loss (RBL) per scenario was analyzed.
Results: Fifty-three anesthetists participated in the study. The median estimated blood loss was 500 ml (IQR 300/1150) compared to the RBL median of 281.5 ml (IQR 210.0/1022.0). Overestimations up to 1233 ml were detected. Underestimations were also observed in the range of 138 ml. The visual estimate for canisters correlated moderately with RBL (Spearman’s rho: 0.818; p < 0.001). Results from univariate nonparametric confirmation statistics regarding visual estimation of canisters show that the deviation of the visual estimate of blood loss is significant (z = − 10.95, p < 0.001, n = 220). Participants’ experience level had no significant influence on VEBL (p = 0.402).
Conclusion: The discrepancies between the visual estimate of canisters and the actual blood loss are enormous despite the given scales. Therefore, we do not recommend estimating the blood loss visually in scaled suction canisters. Colorimetric blood loss estimation could be a more accurate option.
Background: Point of care devices for performing targeted coagulation substitution in patients who are bleeding have become increasingly important in recent years. New on the market is the Quantra. It is a device that uses sonorheometry, a sonic estimation of elasticity via resonance, which is a novel ultrasound-based technology that measures viscoelastic properties of whole blood. Several studies have already shown the comparability of the Quantra with devices already established on the market, such as the rotational thromboelastometry (ROTEM) device.
Objective: In contrast to existing studies, this study is the first prospective interventional study using this new system in a cardiac surgical patient cohort. We will investigate the noninferiority between an already existing coagulation algorithm based on the ROTEM/Multiplate system and a new algorithm based on the Quantra system for the treatment of coagulopathic cardiac surgical patients.
Methods: The study is divided into two phases. In an initial observation phase, whole blood samples of 20 patients obtained at three defined time points (prior to surgery, after completion of cardiopulmonary bypass, and on arrival in the intensive care unit) will be analyzed using both the ROTEM/Multiplate and Quantra systems. The obtained threshold values will be used to develop a novel algorithm for hemotherapy. In a second intervention phase, the new algorithm will be tested for noninferiority against an algorithm used routinely for years in our department.
Results: The main objective of the examination is the cumulative loss of blood within 24 hours after surgery. Statistical calculations based on the literature and in-house data suggest that the new algorithm is not inferior if the difference in cumulative blood loss is <150 mL/24 hours.
Conclusions: Because of the comparability of the Quantra sonorheometry system with the ROTEM measurement methods, the existing hemotherapy treatment algorithm can be adapted to the Quantra device with proof of noninferiority.
Trial Registration: ClinicalTrials.gov NCT03902275; https://clinicaltrials.gov/ct2/show/NCT03902275
International Registered Report Identifier (IRRID): DERR1-10.2196/17206
Transfusion of red blood cells (RBC) in patients undergoing major elective cranial surgery is associated with increased morbidity, mortality and prolonged hospital length of stay (LOS). This retrospective single center study aims to identify the clinical outcome of RBC transfusions on skull base and non-skull base meningioma patients including the identification of risk factors for RBC transfusion. Between October 2009 and October 2016, 423 patients underwent primary meningioma resection. Of these, 68 (16.1%) received RBC transfusion and 355 (83.9%) did not receive RBC units. Preoperative anaemia rate was significantly higher in transfused patients (17.7%) compared to patients without RBC transfusion (6.2%; p = 0.0015). In transfused patients, postoperative complications as well as hospital LOS was significantly higher (p < 0.0001) compared to non-transfused patients. After multivariate analyses, risk factors for RBC transfusion were preoperative American Society of Anaesthesiologists (ASA) physical status score (p = 0.0247), tumor size (p = 0.0006), surgical time (p = 0.0018) and intraoperative blood loss (p < 0.0001). Kaplan-Meier curves revealed significant influence on overall survival by preoperative anaemia, RBC transfusion, smoking, cardiovascular disease, preoperative KPS ≤ 60% and age (elderly ≥ 75 years). We concluded that blood loss due to large tumors or localization near large vessels are the main triggers for RBC transfusion in meningioma patients paired with a potential preselection that masks the effect of preoperative anaemia in multivariate analysis. Further studies evaluating the impact of preoperative anaemia management for reduction of RBC transfusion are needed to improve the clinical outcome of meningioma patients.
Background: Approximately one in three patients suffers from preoperative anaemia. Even though haemoglobin is measured before surgery, anaemia management is not implemented in every hospital. Objective: Here, we demonstrate the implementation of an anaemia walk-in clinic at an Orthopedic University Hospital. To improve the diagnosis of iron deficiency (ID), we examined whether reticulocyte haemoglobin (Ret-He) could be a useful additional parameter. Material and Methods: In August 2019, an anaemia walk-in clinic was established. Between September and December 2019, major orthopaedic surgical patients were screened for preoperative anaemia. The primary endpoint was the incidence of preoperative anaemia. Secondary endpoints included Ret-He level, red blood cell (RBC) transfusion rate, in-hospital length of stay and anaemia at hospital discharge. Results: A total of 104 patients were screened for anaemia. Preoperative anaemia rate was 20.6%. Intravenous iron was supplemented in 23 patients. Transfusion of RBC units per patient (1.7 ± 1.2 vs. 0.2 ± 0.9; p = 0.004) and hospital length of stay (13.1 ± 4.8 days vs. 10.6 ± 5.1 days; p = 0.068) was increased in anaemic patients compared to non-anaemic patients. Ret-He values were significantly lower in patients with ID anaemia (33.3 pg [28.6–40.2 pg]) compared to patients with ID (35.3 pg [28.9–38.6 pg]; p = 0.015) or patients without anaemia (35.4 pg [30.2–39.4 pg]; p = 0.001). Conclusion: Preoperative anaemia is common in orthopaedic patients. Our results proved the feasibility of an anaemia walk-in clinic to manage preoperative anaemia. Furthermore, our analysis supports the use of Ret-He as an additional parameter for the diagnosis of ID in surgical patients.
Background: Iron deficiency (ID) is one of the most common nutritional deficiencies in children worldwide and may result in iron deficiency anemia (IDA). The reticulocyte hemoglobin equivalent (Ret-He) provides information about the current availability of iron in erythropoiesis. This study aims to examine the validation of Ret-He as a screening marker for ID and IDA in children. Methods: Blood samples were retrospectively obtained from medical records. Anemia was defined according to the definition provided by the World Health Organization (WHO) for children. ID was defined by transferrin saturation (TSAT) < 20% and ferritin < 100 ng/mL. Children were classified into four groups: IDA, non-anemia iron deficiency (NAID), control and others. Results: Out of 970 children, 332 (34.2%) had NAID and 278 (28.7%) presented with IDA. Analysis revealed that Ret-He significantly correlates with ferritin (rho = 0.41; p < 0.001), TSAT (rho = 0.66; p < 0.001) and soluble transferrin receptor (sTfR) (rho = −0.72; p < 0.001). For ROC analysis, the area under the curve (AUC) was 0.771 for Ret-He detecting ID and 0.845 for detecting IDA. The cut-off value for Ret-He to diagnose ID was 33.5 pg (sensitivity 90.7%; specificity 35.8%) and 31.6 pg (sensitivity 90.6%; specificity 50.4%) to diagnose IDA. Conclusions: The present study demonstrates Ret-He to be a screening marker for ID and IDA in children. Furthermore, Ret-He can be used as a single screening parameter for ID and IDA in children without considering other iron parameters. Economically, the use of Ret-He is highly relevant, as it can save one blood tube per patient and additional costs.
Background: The intraoperative blood loss is estimated daily in the operating room and is mainly done by visual techniques. Due to local standards, the surgical sponge colours can vary (e.g. white in US, green in Germany). The influence of sponge colour on accuracy of estimation has not been in the focus of research yet. Material and methods: A blood loss simulation study containing four “bleeding” scenarios each per sponge colour were created by using expired whole blood donation samples. The blood donations were applied to white and green surgical sponges after dilution with full electrolyte solution. Study participants had to estimate the absorbed blood loss in sponges in all scenarios. The difference to the reference blood loss was analysed. Multivariate linear regression analysis was performed to investigate other influence factors such as staff experience and sponge colour. Results: A total of 53 anaesthesists participated in the study. Visual estimation correlated moderately with reference blood loss in white (Spearman's rho: 0.521; p = 3.748*10−16) and green sponges (Spearman's rho: 0.452; p = 4.683*10−12). The median visually estimated blood loss was higher in white sponges (250ml IRQ 150–412.5ml) than in green sponges (150ml IQR 100-300ml), compared to reference blood loss (103ml IQR 86–162.8). For both colour types of sponges, major under- and overestimation was observed. The multivariate statistics demonstrates that fabric colours have a significant influence on estimation (p = 3.04*10−10), as well as clinician’s qualification level (p = 2.20*10−10, p = 1.54*10−08) and amount of RBL to be estimated (p < 2*10−16). Conclusion: The deviation of correct blood loss estimation was smaller with white surgical sponges compared to green sponges. In general, deviations were so severe for both types of sponges, that it appears to be advisable to refrain from visually estimating blood loss whenever possible and instead to use other techniques such as e.g. colorimetric estimation.
Purpose: Trauma is the leading cause of death in children. In adults, blood transfusion and fluid resuscitation protocols changed resulting in a decrease of morbidity and mortality over the past 2 decades. Here, transfusion and fluid resuscitation practices were analysed in severe injured children in Germany.
Methods: Severely injured children (maximum Abbreviated Injury Scale (AIS) ≥ 3) admitted to a certified trauma-centre (TraumaZentrum DGU®) between 2002 and 2017 and registered at the TraumaRegister DGU® were included and assessed regarding blood transfusion rates and fluid therapy.
Results: 5,118 children (aged 1–15 years) with a mean ISS 22 were analysed. Blood transfusion rates administered until ICU admission decreased from 18% (2002–2005) to 7% (2014–2017). Children who are transfused are increasingly seriously injured. ISS has increased for transfused children aged 1–15 years (2002–2005: mean 27.7–34.4 in 2014–2017). ISS in non-transfused children has decreased in children aged 1–15 years (2002–2005: mean 19.6 to mean 17.6 in 2014–2017). Mean prehospital fluid administration decreased from 980 to 549 ml without affecting hemodynamic instability.
Conclusion: Blood transfusion rates and amount of fluid resuscitation decreased in severe injured children over a 16-year period in Germany. Restrictive blood transfusion and fluid management has become common practice in severe injured children. A prehospital restrictive fluid management strategy in severely injured children is not associated with a worsened hemodynamic state, abnormal coagulation or base excess but leads to higher hemoglobin levels.
Background: paediatric patients are vulnerable to blood loss and even a small loss of blood can be associated with severe shock. In emergency situations, a red blood cell (RBC) transfusion may become unavoidable, although it is associated with various risks. The aim of this trial was to identify independent risk factors for perioperative RBC transfusion in children undergoing surgery. Methods: to identify independent risk factors for perioperative RBC transfusion in children undergoing surgery and to access RBC transfusion rates and in-hospital outcomes (e.g., length of stay, mortality, and typical postoperative complication rates), a monocentric, retrospective, and observational study was conducted. Descriptive, univariate, and multivariate analyses were performed. Results: between 1 January 2010 and 31 December 2019, data from n = 14,248 cases were identified at the centre. Analysis revealed an RBC transfusion rate of 10.1% (n = 1439) in the entire cohort. The independent predictors of RBC transfusion were the presence of preoperative anaemia (p < 0.001; OR = 15.10 with preoperative anaemia and OR = 2.40 without preoperative anaemia), younger age (p < 0.001; ORs between 0.14 and 0.28 for children older than 0 years), female gender (p = 0.036; OR = 1.19 compared to male gender), certain types of surgery (e.g., neuro surgery (p < 0.001; OR = 10.14), vascular surgery (p < 0.001; OR = 9.93), cardiac surgery (p < 0.001; OR = 4.79), gynaecology (p = 0.014; OR = 3.64), visceral surgery (p < 0.001; OR = 2.48), and the presence of postoperative complications (e.g., sepsis (p < 0.001; OR = 10.16), respiratory dysfunction (p < 0.001; OR = 7.56), cardiovascular dysfunction (p < 0.001; OR = 4.68), neurological dysfunction (p = 0.029; OR = 1.77), and renal dysfunction (p < 0.001; OR = 16.17)). Conclusion: preoperative anaemia, younger age, female gender, certain types of surgery, and postoperative complications are independent predictors for RBC transfusion in children undergoing surgery. Future prospective studies are urgently required to identify, in detail, the potential risk factors and impact of RBC transfusion in children.