Refine
Year of publication
Language
- English (154)
Has Fulltext
- yes (154)
Is part of the Bibliography
- no (154)
Keywords
- BESIII (11)
- e +-e − Experiments (8)
- Branching fraction (7)
- Hadronic decays (4)
- Lepton colliders (4)
- Quarkonium (4)
- Branching fractions (3)
- Charmed mesons (3)
- Electroweak interaction (3)
- Exotics (3)
- Particle and Resonance Production (3)
- e+-e− Experiments (3)
- CBA (2)
- Charm Physics (2)
- Charm physics (2)
- Electroweak Interaction (2)
- IL-6 (2)
- Initial state radiation (2)
- Leptonic, semileptonic & radiative decays (2)
- Particle decays (2)
- QCD (2)
- SD-OCT (2)
- Spectroscopy (2)
- VEGF (2)
- pest risk mapping (2)
- APMPPE - acute posterior multifocal placoid pigment epitheliopathy (1)
- Annihilation (1)
- BESIII detector (1)
- BRVO (1)
- Bhabha (1)
- Born cross section measurement (1)
- Borrelia (1)
- CP violation (1)
- CRVO (1)
- Charmonium (1)
- Charmonium (-like) (1)
- Covariance matrix (1)
- Cross section (1)
- D meson (1)
- Dalitz decay (1)
- Dark photon (1)
- Dark sector (1)
- D⁰ meson (1)
- Electromagnetic form factor (1)
- Electromagnetic form factors (1)
- Experimental nuclear physics (1)
- Experimental particle physics (1)
- FOS: Physical sciences (1)
- Flavor changing neutral currents (1)
- Flavor symmetries (1)
- Flavour Physics (1)
- Form factors (1)
- Hadronic cross section (1)
- High Energy Physics - Experiment (hep-ex) (1)
- Human-mediated dispersal (1)
- Hyperons (1)
- Invisible decays (1)
- Lyme disease - Borreliosis (1)
- MCP (1)
- MCP-1 (1)
- Muon anomaly (1)
- Neutrinos (1)
- Particle and resonance production (1)
- Particle phenomena (1)
- Pion form factor (1)
- Polarization (1)
- Proton (1)
- Quantum chromodynamics (1)
- Rare decays (1)
- Risk aversion (1)
- Semi-leptonic decays (1)
- Techniques Electromagnetic calorimeters (1)
- Vitreous samples (1)
- Y states (1)
- center-of-mass energy (1)
- charmonium-like states (1)
- clinical trial (1)
- decision-making under uncertainty (1)
- diabetic macular edema (1)
- dimuon (1)
- e+e − annihilation (1)
- e+e⁻ − Experiments (1)
- electron-positron collision (1)
- firewood (1)
- firewood movement (1)
- fluocinolone acetonide (1)
- forest pests (1)
- hadron spectroscopy (1)
- hadronic events (1)
- helicity amplitude analysis (1)
- inclusive J/ψ decays (1)
- macula (1)
- microdosing (1)
- network modelling (1)
- number of J/ψ events (1)
- pathway invasion model (1)
- pharmacology (1)
- retina (1)
- stochastic dominance (1)
- tetraquark (1)
- trigger efficiency (1)
- uncertainty (1)
- vitreous samples (1)
- Λ+c baryon (1)
- Σ hyperon (1)
Purpose: To evaluate the efficacy of the virtual reality training simulator Eyesi to prepare surgeons for performing pars plana vitrectomies and its potential to predict the surgeons’ performance.
Methods: In a preparation phase, four participating vitreoretinal surgeons performed repeated simulator training with predefined tasks. If a surgeon was assigned to perform a vitrectomy for the management of complex retinal detachment after a surgical break of at least 60 hours it was randomly decided whether a warmup training on the simulator was required (n = 9) or not (n = 12). Performance at the simulator was measured using the built-in scoring metrics. The surgical performance was determined by two blinded observers who analyzed the video-recorded interventions. One of them repeated the analysis to check for intra-observer consistency. The surgical performance of the interventions with and without simulator training was compared. In addition, for the surgeries with simulator training, the simulator performance was compared to the performance in the operating room.
Results: Comparing each surgeon’s performance with and without warmup trainingshowed a significant effect of warmup training onto the final outcome in the operating room. For the surgeries that were preceeded by the warmup procedure, the performance at the simulator was compared with the operating room performance. We found that there is a significant relation. The governing factor of low scores in the simulator were iatrogenic retinal holes, bleedings and lens damage. Surgeons who caused minor damage in the simulation also performed well in the operating room.
Conclusions: Despite the large variation of conditions, the effect of a warmup training as well as a relation between the performance at the simulator and in the operating room was found with statistical significance. Simulator training is able to serve as a warmup to increase the average performance.
Purpose: There are little or no published data comparing the outcomes of ILUVIEN® (0.19 mg fluocinolone acetonide [FAc]) and OZURDEX® (0.7 mg dexamethasone [DEX]) implants in patients with diabetic macular edema (DME), and this case sought to compare their outcomes.
Methods: This case was extracted from a monocentric audit involving a pool of 25 patients (33 eyes) with DME and treated with a single FAc implant between October 2013 and December 2016. This case, a 61-year-old male with a pseudophakic lens, is from a patient that had received 4 intravitreal injections of a DEX implant prior to FAc implant and then was monitored for 3 years until re-treatment with a second FAc implant. Parameters measured included visual acuity (VA), central retinal thickness (CRT), and intraocular pressure (IOP).
Results: After the DEX implants, CRT transiently improved. In March 2014, the decision was taken to administer an FAc implant, and this led to a reduction in CRT below 300 µm (from a baseline of 748 µm), and this was sustained for 30 months. VA remained above 65 Early Treatment Diabetic Retinopathy Study letters to month 36, after which time a second FAc implant (in April 2017) was administered due to recurrence of edema and CRT decreased to below 300 µm and VA improved to 70 letters. Side effects included elevated IOP, which was effectively managed with IOP-lowering drops.
Conclusion: A single injection of FAc implant led to sustained improvements in CRT and VA that lasted for between 30 and 36 months, which is in contrast to the DEX implant where re-treatment was generally required within 6–7 months. After 36 months, re-treatment with the FAc implant again led to improved VA and CRT, and responses that were similar to those achieved with the first FAc implant.
Representing uncertainty in a spatial invasion model that incorporates human-mediated dispersal
(2013)
Most modes of human-mediated dispersal of invasive species are directional and vector-based. Classical spatial spread models usually depend on probabilistic dispersal kernels that emphasize distance over direction and have limited ability to depict rare but influential long-distance dispersal events. These aspects are problematic if such models are used to estimate invasion risk. Alternatively, a geographic network model may be better at estimating the typically low likelihoods associated with human-mediated dispersal events, but it should also provide a reasonable account of uncertainties that could affect perception of its risk estimates. We developed a network model that assesses the likelihood of dispersal of invasive forest pests in camper-transported firewood in North America. We built the model using data from the U.S. National Recreation Reservation Service, which document visitor travel between populated places and federal campgrounds across the U.S. and Canada. The study area is depicted as a set of coarse-resolution map units. Based on repeated simulations, the model estimates the probability that each unit is a possible origin and destination for firewood-facilitated forest pest invasions. We generated output maps that summarise, for each U.S. state and Canadian province, where (outside the state or province) a camper-transported forest pest likely originated. Treating these output maps as a set of baseline scenarios, we explored the sensitivity of these “origin risk” estimates to additive and multiplicative errors in the probabilities of pest transmission between locations, as well as random changes in the structure of the underlying travel network. We found the patterns of change in the origin risk estimates due to these alterations to be consistent across all states and provinces. This indicates that the network model behaves predictably in the presence of uncertainties, allowing future work to focus on closing knowledge gaps or more sophisticated treatments of the impact of uncertainty on model outputs.
Purpose: To analyze the protein profile of human vitreous of untreated patients with retinal vein occlusion (RVO).
Methods: Sixty-eight vitreous humor (VH) samples (44 from patients with treatment naïve RVO, 24 controls with idiopathic floaters) were analyzed in this clinical-experimental study using capillary electrophoresis coupled to mass spectrometer and tandem mass spectrometry. To define potential candidate protein markers of RVO, proteomic analysis was performed on RVO patients (n = 30) and compared with controls (n = 16). To determine validity of potential biomarker candidates in RVO, receiver operating characteristic (ROC) was performed by using proteome data of independent RVO (n = 14) and control samples (n = 8).
Results: Ninety-four different proteins (736 tryptic peptides) could be identified. Sixteen proteins were found to be significant when comparing RVO and control samples (P = 1.43E-05 to 4.48E-02). Five proteins (Clusterin, Complement C3, Ig lambda-like polypeptide 5 (IGLL5), Opticin and Vitronectin), remained significant after using correction for multiple testing. These five proteins were also detected significant when comparing subgroups of RVO (central RVO, hemi-central RVO, branch RVO) to controls. Using independent samples ROC-Area under the curve was determined proving the validity of the results: Clusterin 0.884, Complement C3 0.955, IGLL5 1.000, Opticin 0.741, Vitronectin 0.786. In addition, validation through ELISA measurements was performed.
Conclusion: The results of the study reveal that the proteomic composition of VH differed significantly between the patients with RVO and the controls. The proteins identified may serve as potential biomarkers for pathogenesis induced by RVO.