Refine
Year of publication
Document Type
- Article (152)
- Preprint (123)
- Working Paper (1)
Language
- English (276)
Has Fulltext
- yes (276)
Is part of the Bibliography
- no (276)
Keywords
- BESIII (17)
- e +-e − Experiments (12)
- Branching fraction (9)
- Particle and Resonance Production (7)
- Hadronic decays (5)
- Spectroscopy (5)
- Branching fractions (4)
- Charm Physics (4)
- Lepton colliders (4)
- Quarkonium (4)
We report on a polarization measurement of inclusive J/ψ mesons in the di-electron decay channel at mid-rapidity at 2 < pT < 6 GeV/c in p + p collisions at √s = 200 GeV. Data were taken with the STAR detector at RHIC. The J/ψ polarization measurement should help to distinguish between different models of the J/ψ production mechanism since they predict different pT dependences of the J/ψ polarization. In this analysis, J/ψ polarization is studied in the helicity frame. The polarization parameter λθ measured at RHIC becomes smaller towards high pT , indicating more longitudinal J/ψ polarization as pT increases. The result is compared with predictions of presently available models.
A data-driven method was applied to Au+Au collisions at √sNN = 200 GeV made with the STAR detector at RHIC to isolate pseudorapidity distance η-dependent and η-independent correlations by using two- and four-particle azimuthal cumulant measurements. We identified a η-independent component of the correlation, which is dominated by anisotropic flow and flow fluctuations. It was also found to be independent of η within the measured range of pseudorapidity |η| < 1. In 20–30% central Au+Au collisions, the relative flow fluctuation was found to be 34%±2%(stat.)±3%(sys.) for particles with transverse momentum pT less than 2 GeV/c. The η-dependent part, attributed to nonflow correlations, is found to be 5% ± 2%(sys.) relative to the flow of the measured second harmonic cumulant at |η| > 0.7.
Effect of event selection on jetlike correlation measurement in d+Au collisions at √sNN = 200 GeV
(2015)
Dihadron correlations are analyzed in √sNN = 200 GeV d + Au collisions classified by forward charged particle multiplicity and zero-degree neutral energy in the Au-beam direction. It is found that the jetlike correlated yield increases with the event multiplicity. After taking into account this dependence, the non-jet contribution on the away side is minimal, leaving little room for a back-to-back ridge in these collisions.
A wide variety of enzymatic pathways that produce specialized metabolites in bacteria, fungi and plants are known to be encoded in biosynthetic gene clusters. Information about these clusters, pathways and metabolites is currently dispersed throughout the literature, making it difficult to exploit. To facilitate consistent and systematic deposition and retrieval of data on biosynthetic gene clusters, we propose the Minimum Information about a Biosynthetic Gene cluster (MIBiG) data standard.
Non-standard errors
(2021)
In statistics, samples are drawn from a population in a data-generating process (DGP). Standard errors measure the uncertainty in sample estimates of population parameters. In science, evidence is generated to test hypotheses in an evidence-generating process (EGP). We claim that EGP variation across researchers adds uncertainty: non-standard errors. To study them, we let 164 teams test six hypotheses on the same sample. We find that non-standard errors are sizeable, on par with standard errors. Their size (i) co-varies only weakly with team merits, reproducibility, or peer rating, (ii) declines significantly after peer-feedback, and (iii) is underestimated by participants.
Background: The number of implantable cardioverter defibrillator (ICD) infections is increasing due to an increased number of ICD implants, higher-risk patients, and more frequent replacement procedures, which carry a higher risk of infection. Reducing the morbidity, mortality, and cost of ICD-related infections requires an understanding of the current rate of this complication and its predictors.
Methods: The Shock Implant Evaluation Trial (SIMPLE) trial randomized 2500 ICD recipients to defibrillation testing or not. Over an average of 3.1 years, patients were seen every 6 months and examined for evidence of ICD infection, which was defined as requiring device removal and/or intravenous antibiotics.
Results: Within 24 months, 21 patients (0.8%) developed infection. Fourteen patients (67%) with infection presented within 30 days, 20 patients by 12 months, and only 1 patient beyond 12 months. Univariate analysis demonstrated that patients with primary electrical disorders (3 patients, P = 0.009) and those with a secondary prevention indication (13 patients, P = 0.0009) were more likely to develop infection. Among the 2.2% of patients who developed an ICD wound hematoma, 10.4% developed an infection. Among the 8.3% of patients requiring an ICD reintervention, 1.9% developed an infection.
Conclusions: This cohort of ICD recipients at high-volume centres have a low risk of device-related infection. However; strategies to reduce wound hematoma and the need for ICD reintervention could further reduce the rate of infection.