Refine
Year of publication
Document Type
- Article (28)
- Doctoral Thesis (1)
- Working Paper (1)
Has Fulltext
- yes (30)
Is part of the Bibliography
- no (30)
Keywords
- Musculoskeletal system (3)
- ergonomics (3)
- inertial motion capture (3)
- Healthy adults (2)
- Knees (2)
- kinematic analysis (2)
- musculoskeletal disorders (2)
- ACLF (1)
- AD patients (1)
- Anatomy (1)
- Arms (1)
- Back scan (1)
- Bewegungsanalyse mit Inertialsensoren (1)
- Blocked occlusion (1)
- Body sway (1)
- CRM1 (1)
- Custom-made mouthguard (1)
- DST (1)
- Dentists (1)
- Deutschland (1)
- Drug susceptibility testing (1)
- Ergonomic analysis (1)
- Ergonomics (1)
- Ergonomie am Arbeitsplatz (1)
- Ergonomische Analyse (1)
- Factor analysis (1)
- GTPase (1)
- Glioma (1)
- Hedging (1)
- Hip (1)
- Inertial motion capture (1)
- Investmentfonds (1)
- Investmentsparen (1)
- Isocitrate dehydrogenase (1)
- Jaw (1)
- Jumping (1)
- Kapitalertrag (1)
- Kapitalgewinn (1)
- Legs (1)
- Limited Partnership (1)
- Long Term Investment (1)
- M. Intracellulare (1)
- M. avium (1)
- M. avium complex (1)
- M. chimaera (1)
- MEIS2 (1)
- MRI patterns of gliomas (1)
- Medical research (1)
- Meersseman test (1)
- Musculoskeletal diseases (1)
- Musculoskeletal problems (1)
- Muskuloskelettale Erkrankungen (1)
- Myalgia (1)
- Mängelhaftung (1)
- NTM (1)
- Non-tuberculous mycobacteria (1)
- Normal distribution (1)
- Occupational health (1)
- Orthopaedics (1)
- PBX1 (1)
- PWI (1)
- Pension Finance (1)
- Postural control (1)
- Posture analysis (1)
- Preventive medicine (1)
- Private Altersversorgung (1)
- Pseudoprogression (1)
- RULA (1)
- Ready-made mouthguard (1)
- Regulation (1)
- Rentenreform (1)
- Rheb (1)
- Risiko (1)
- SPSS (1)
- Shortfall Risk (1)
- Sphingosine-1-Phosphate (1)
- Symmetrical blocked occlusion (1)
- TALE-homdomain protein (1)
- TSC2 (1)
- Taekwondoka (1)
- Torque (1)
- Translational research (1)
- Tubers (1)
- Ubiquitin (1)
- Ubiquitin-Protein-Ligase (1)
- Upper body posture (1)
- Videorasterstereography (1)
- Weight distribution (1)
- Workplace ergonomics (1)
- [18F]FET PET (1)
- acute decompensation (1)
- acute-on-chronic liver failure (1)
- amyloid precursor protein (APP) (1)
- apoptosis (1)
- cirrhosis (1)
- cleaning (1)
- computed tomography (1)
- controlled nuclear import (1)
- dental assistant (1)
- dental treatment concept (1)
- dentist (1)
- dentist’s chair design (1)
- glioblastoma (1)
- hepatic encephalopathy (1)
- human factors (1)
- inertial motion units (1)
- inertial sensors (1)
- kinematics (1)
- liver (1)
- lymphocytes (1)
- mTOR (1)
- malignant glioma (1)
- movement pattern (1)
- movement profile (1)
- neurogenesis (1)
- portal hypertension (1)
- portosystemic shunt (1)
- posttranslational modification (1)
- presenilin-1 (1)
- regorafenib (1)
- regorafenib csf concentration (1)
- risk assessment (1)
- running (1)
- sonoSens (1)
- spontaneous portosystemic shunt (1)
- statistical parametric mapping (1)
- stem cell niche (1)
- subventricular zone (1)
- transgenic mice (1)
- triathlon (1)
- vacuuming (1)
- wearable sensors (1)
- work place evaluation (1)
Institute
Musculoskeletal disorders of the trunk and neck are common among cleaners. Vacuum cleaning is a demanding activity. The aim of this study was to present the movement profile of the trunk and neck during habitual vacuuming. The data were collected from 31 subjects (21f./10 m) using a 3D motion analysis system (Xsens). 10 cycles were analysed in vacuuming PVC and carpet floors with 8 vacuum cleaners. The joint angles and velocities were represented statistically descriptive. When vacuuming, the trunk is held in a forwardly inclined position by a flexion in the hip and rotated from this position. In the joint angles and velocities of the spine, the rotation proved to be dominant. A relatively large amount of movement took place in the cervical spine and also in the lumbar spine. The shown movement profile is rather a comfort area of vacuuming which may serve as a reference for ergonomics in vacuuming.
Background: In clinical practice range of motion (RoM) is usually assessed with low-cost devices such as a tape measure (TM) or a digital inclinometer (DI). However, the intra- and inter-rater reliability of typical RoM tests differ, which impairs the evaluation of therapy progress. More objective and reliable kinematic data can be obtained with the inertial motion capture system (IMC) by Xsens. The aim of this study was to obtain the intra- and inter-rater reliability of the TM, DI and IMC methods in five RoM tests: modified Thomas test (DI), shoulder test modified after Janda (DI), retroflexion of the trunk modified after Janda (DI), lateral inclination (TM) and fingertip-to-floor test (TM).
Methods: Two raters executed the RoM tests (TM or DI) in a randomized order on 22 healthy individuals while, simultaneously, the IMC data (Xsens MVN) was collected. After 15 warm-up repetitions, each rater recorded five measurements.
Findings: Intra-rater reliabilities were (almost) perfect for tests in all three devices (ICCs 0.886–0.996). Inter-rater reliability was substantial to (almost) perfect in the DI (ICCs 0.71–0.87) and the IMC methods (ICCs 0.61–0.993) and (almost) perfect in the TM methods (ICCs 0.923–0.961). The measurement error (ME) for the tests measured in degree (°) was 0.9–3.3° for the DI methods and 0.5–1.2° for the IMC approaches. In the tests measured in centimeters the ME was 0.5–1.3cm for the TM methods and 0.6–2.7cm for the IMC methods. Pearson correlations between the results of the DI or the TM respectively with the IMC results were significant in all tests except for the shoulder test on the right body side (r = 0.41–0.81).
Interpretation: Measurement repetitions of either one or multiple trained raters can be considered reliable in all three devices.
In the application of range of motion (ROM) tests there is little agreement on the number of repetitions to be measured and the number of preceding warm-up protocols. In stretch training a plateau in ROM gains can be seen after four to five repetitions. With increasing number of repetitions, the gain in ROM is reduced. This study examines the question of whether such an effect occurs in common ROM tests. Twenty-two healthy sport students (10 m/12 f.) with an average age of 25.3 ± 1.94 years (average height 174.1 ± 9.8 cm; weight 66.6 ± 11.3 kg and BMI 21.9 ± 2.0 kg/cm2) volunteered in this study. Each subject performed five ROM tests in a randomized order—measured either via a tape measure or a digital inclinometer: Tape measure was used to evaluate the Fingertip-to-Floor test (FtF) and the Lateral Inclination test (LI). Retroflexion of the trunk modified after Janda (RF), Thomas test (TT) and a Shoulder test modified after Janda (ST) were evaluated with a digital inclinometer. In order to show general acute effects within 20 repetitions we performed ANOVA/Friedman-test with multiple comparisons. A non-linear regression was then performed to identify a plateau formation. Significance level was set at 5%. In seven out of eight ROM tests (five tests in total with three tests measured both left and right sides) significant flexibility gains were observed (FtF: p < 0.001; LI-left/right: p < 0.001/0.001; RF: p = 0.009; ST-left/right: p < 0.001/p = 0.003; TT-left: p < 0.001). A non-linear regression with random effects was successfully applied on FtF, RF, LI-left/right, ST-left and TT-left and thus, indicate a gradual decline in the amount of gained ROM. An acute effect was observed in most ROM tests, which is characterized by a gradual decline of ROM gain. For those tests, we can state that the acute effect described in the stretching literature also applies to the performance of typical ROM tests. Since a non-linear behavior was shown, it is the decision of the practitioner to weigh up between measurement accuracy and expenditure. Researchers and practitioners should consider this when applying ROM assessments to healthy young adults.
Background: Temporary occlusal changes and their influence on the upper body statics are still controversially discussed. Furthermore, concrete statements on whether age- or gender-specific differences in neurophysiological reactions exist are missing. Therefore, it is the aim of this study to evaluate the immediate effects of a symmetrical occlusion blocking on the upper body posture. These effects shall be investigated for both genders and for a larger age range.
Methods: In this study, 800 (407f/393 m) subjects volunteered aged from 21 to 60 years. Both genders were divided into four age groups according to decades. The three-dimensional upper body posture was measured by using the rasterstereography (ABW-Bodymapper). The habitual static posture was measured in two dental occlusion conditions (a) in rest position and (b) symmetrical blocking in the bicuspid region by cotton rolls.
Results: A significant reduction of the trunk length (0.72 mm; p < 0.001), an increase of the lumbar (0.30°; p < 0.001) and the thoracic bending angle (0.14°; p = 0.001), a reduction of the spinal forward decline (0.16°; p < 0.001) and a reduction of the scapular distance (0.36 mm; p = 0.001) was found. Gender-specific reactions can only be recorded in scapular distance, in that regard men reduce this distance while over all age groups women did not show a significant change.
Discussion: Slight gender- and age-independent reactions due to a symmetric occlusion blockade are shown: A gender independent reaction of the spinal related variables in the sagittal plane (thoracic and lumbar flexion angle, trunk length, spinal forward decline). In addition, a gender specific change of the shoulder blade distance could be observed, where men reduced the distance while female did not show a change. However, since these reactions are of a minimum amount, it can be concluded that neurophysiological compensation mechanisms work equally well regardless of age and sex, and the upper body posture of healthy people changes only very slightly due to a temporarily symmetrical altered bite position.
The aim of this study was to investigate gender-specific influences of different symmetric and asymmetric occlusion conditions on postural control during standing and walking. The study involved 59 healthy adult volunteers (41 f/19 m) aged between 22 and 53 years (30.2 ± 6.3 years). Postural control measurements were carried out using a pressure plate by measuring plantar pressure distribution during standing and walking test conditions. Seven different occlusion conditions were tested. Prior to a MANOVA model analysis, the relationship between the two test conditions were checked using a factor analysis with a varying number of factors (between 2 and 10). The plantar pressure distributions during walking and standing are independent test conditions. The coefficient of variance across all variables between the conditions and genders was not significant: t(46) = 1.51 (p = 0.13). No statement can be made whether, or not, the influence of gender is greater than the influence of the conditions. Healthy male and female test subjects did not show any difference between seven occlusion conditions on the plantar pressure distribution while standing or walking. No differences between the genders were found for any of the investigated variables. In contrast to custom-made occlusion splints, simple cotton rolls appear not to influence the neuromuscular system in a systematic manner.
Background: In general, the prevalence of work-related musculoskeletal disorders (WMSD) in dentistry is high, and dental assistants (DA) are even more affected than dentists (D). Furthermore, differentiations between the fields of dental specialization (e.g., general dentistry, endodontology, oral and maxillofacial surgery, or orthodontics) are rare. Therefore, this study aims to investigate the ergonomic risk of the aforementioned four fields of dental specialization for D and DA on the one hand, and to compare the ergonomic risk of D and DA within each individual field of dental specialization. Methods: In total, 60 dentists (33 male/27 female) and 60 dental assistants (11 male/49 female) volunteered in this study. The sample was composed of 15 dentists and 15 dental assistants from each of the dental field, in order to represent the fields of dental specialization. In a laboratory setting, all tasks were recorded using an inertial motion capture system. The kinematic data were applied to an automated version of the Rapid Upper Limb Assessment (RULA). Results: The results revealed significantly reduced ergonomic risks in endodontology and orthodontics compared to oral and maxillofacial surgery and general dentistry in DAs, while orthodontics showed a significantly reduced ergonomic risk compared to general dentistry in Ds. Further differences between the fields of dental specialization were found in the right wrist, right lower arm, and left lower arm in DAs and in the neck, right wrist, right lower arm, and left wrist in Ds. The differences between Ds and DAs within a specialist discipline were rather small. Discussion: Independent of whether one works as a D or DA, the percentage of time spent working in higher risk scores is reduced in endodontologists, and especially in orthodontics, compared to general dentists or oral and maxillofacial surgeons. In order to counteract the development of WMSD, early intervention should be made. Consequently, ergonomic training or strength training is recommended.
Purpose: Perfusion-weighted MRI (PWI) and O-(2-[18F]fluoroethyl-)-l-tyrosine ([18F]FET) PET are both applied to discriminate tumor progression (TP) from treatment-related changes (TRC) in patients with suspected recurrent glioma. While the combination of both methods has been reported to improve the diagnostic accuracy, the performance of a sequential implementation has not been further investigated. Therefore, we retrospectively analyzed the diagnostic value of consecutive PWI and [18F]FET PET.
Methods: We evaluated 104 patients with WHO grade II–IV glioma and suspected TP on conventional MRI using PWI and dynamic [18F]FET PET. Leakage corrected maximum relative cerebral blood volumes (rCBVmax) were obtained from dynamic susceptibility contrast PWI. Furthermore, we calculated static (i.e., maximum tumor to brain ratios; TBRmax) and dynamic [18F]FET PET parameters (i.e., Slope). Definitive diagnoses were based on histopathology (n = 42) or clinico-radiological follow-up (n = 62). The diagnostic performance of PWI and [18F]FET PET parameters to differentiate TP from TRC was evaluated by analyzing receiver operating characteristic and area under the curve (AUC).
Results: Across all patients, the differentiation of TP from TRC using rCBVmax or [18F]FET PET parameters was moderate (AUC = 0.69–0.75; p < 0.01). A rCBVmax cutoff > 2.85 had a positive predictive value for TP of 100%, enabling a correct TP diagnosis in 44 patients. In the remaining 60 patients, combined static and dynamic [18F]FET PET parameters (TBRmax, Slope) correctly discriminated TP and TRC in a significant 78% of patients, increasing the overall accuracy to 87%. A subgroup analysis of isocitrate dehydrogenase (IDH) mutant tumors indicated a superior performance of PWI to [18F]FET PET (AUC = 0.8/< 0.62, p < 0.01/≥ 0.3).
Conclusion: While marked hyperperfusion on PWI indicated TP, [18F]FET PET proved beneficial to discriminate TP from TRC when PWI remained inconclusive. Thus, our results highlight the clinical value of sequential use of PWI and [18F]FET PET, allowing an economical use of diagnostic methods. The impact of an IDH mutation needs further investigation.
Objective: Phenotypic (Sensititre Myco, pDST) and genotypic drug susceptibility testing (GenoType NTM DR, gDST) in M. avium complex (MAC) have become available as standardized assays, but comparable data is needed. This study aimed to investigate the phenotypic and genotypic drug susceptibility patterns in MAC clinical isolates.
Methods: Overall, 98 isolates from 85 patients were included. pDST and gDST were performed on all isolates and results compared regarding specificity and sensitivity using pDST as a reference method. The impact of drug instability on pDST results was studied using a biological assay over 14 days. In addition, the evolution of antimicrobial resistance was investigated in sequential isolates of 13 patients.
Results: Macrolide resistance was rare, 1.2% (95% CI 0.7–7.3) of isolates in the base cohort. No aminoglycoside resistances were found, but 14.1% of the studied isolates (95% CI 7.8–23.8) showed intermediate susceptibility. The GenoType NTM DR identified two out of four macrolide-resistant isolates. Antibiotic stability was demonstrated to be poor in rifampicin, rifabutin, and doxycycylin.
Conclusions: pDST results in NTM for unstable antibiotics must be interpreted with care. A combination of pDST and gDST will be useful for the guidance of antimicrobial therapy in MAC-disease.
Money-back guarantees in individual pension accounts : evidence from the German pension reform
(2002)
The German Retirement Saving Act instituted a new funded system of supplementary pensions coupled with a general reduction in the level of state pay-as-you-go old-age pensions. In order to qualify for tax relief, the providers of supplementary savings products must offer a guarantee of the nominal value at retirement of contributions paid into these saving accounts. This paper explores how this "money-back" guarantee works and evaluates alternative designs for guarantee structures, including a life cycle model (dynamic asset allocation), a plan with a pre-specified blend of equity and bond investments (static asset allocation), and some type of portfolio insurance. We use a simulation methodology to compare hedging effectiveness and hedging costs associated with the provision of the money-back guarantee. In addition, the guarantee has important implications for regulators who must find an appropriate solvency system for such saving schemes. This version June 17, 2002 . Klassifikation: G11, G23, G28
Background: The aim is to investigate to what extent the different oral protections compared to the habitual occlusion affect the upper body posture in statics and during taekwondo-specific movement.
Methods: 12 Taekwondoka (5 f/7 m) of German national team were measured by using a 3d back scanner and an ultrasonic distance measuring (upright stand, taekwondo attack and defense movement, two taekwondo specific combinations) in habitual occlusion, with a custom-made and ready-made mouth protection
Results: There are no significant changes in the upper body posture (p ≥ 0.05). Depending on the dynamic measurements, different significant reactions of the spinal position were found while wearing the custom made mouthguard or the ready-made mouthguard according to the conducted movement.
Conclusion: The measured changes in dynamic movements are not clinical relevant. Based on the positive responses from the participants, the custom-made mouth protection can be recommended combined with an individual analysis.