Refine
Year of publication
- 2013 (7) (remove)
Document Type
- Article (7)
Language
- English (7)
Has Fulltext
- yes (7)
Is part of the Bibliography
- no (7)
Keywords
- ALICE experiment (1)
- Beauty production (1)
- Heavy flavor production (1)
- LHC (1)
- Single electrons (1)
- adjustment (1)
- homogeneity (1)
- pp collisions (1)
- solar surface irradiance (1)
Institute
- Frankfurt Institute for Advanced Studies (FIAS) (3)
- Informatik (3)
- Physik (3)
- Biowissenschaften (2)
- Geowissenschaften (1)
- Medizin (1)
The project focuses on the efficiency of combined technologies to reduce the release of micropollutants and bacteria into surface waters via sewage treatment plants of different size and via stormwater overflow basins of different types. As a model river in a highly populated catchment area, the river Schussen and, as a control, the river Argen, two tributaries of Lake Constance, Southern Germany, are under investigation in this project. The efficiency of the different cleaning technologies is monitored by a wide range of exposure and effect analyses including chemical and microbiological techniques as well as effect studies ranging from molecules to communities.
This study presents a method for adjusting long-term climate data records (CDRs) for the integrated use with near-real-time data using the example of surface incoming solar irradiance (SIS). Recently, a 23-year long (1983–2005) continuous SIS CDR has been generated based on the visible channel (0.45–1 μm) of the MVIRI radiometers onboard the geostationary Meteosat First Generation Platform. The CDR is available from the EUMETSAT Satellite Application Facility on Climate Monitoring (CM SAF). Here, it is assessed whether a homogeneous extension of the SIS CDR to the present is possible with operationally generated surface radiation data provided by CM SAF using the SEVIRI and GERB instruments onboard the Meteosat Second Generation satellites. Three extended CM SAF SIS CDR versions consisting of MVIRI-derived SIS (1983–2005) and three different SIS products derived from the SEVIRI and GERB instruments onboard the MSG satellites (2006 onwards) were tested. A procedure to detect shift inhomogeneities in the extended data record (1983–present) was applied that combines the Standard Normal Homogeneity Test (SNHT) and a penalized maximal T-test with visual inspection. Shift detection was done by comparing the SIS time series with the ground stations mean, in accordance with statistical significance. Several stations of the Baseline Surface Radiation Network (BSRN) and about 50 stations of the Global Energy Balance Archive (GEBA) over Europe were used as the ground-based reference. The analysis indicates several breaks in the data record between 1987 and 1994 probably due to artefacts in the raw data and instrument failures. After 2005 the MVIRI radiometer was replaced by the narrow-band SEVIRI and the broadband GERB radiometers and a new retrieval algorithm was applied. This induces significant challenges for the homogenisation across the satellite generations. Homogenisation is performed by applying a mean-shift correction depending on the shift size of any segment between two break points to the last segment (2006–present). Corrections are applied to the most significant breaks that can be related to satellite changes. This study focuses on the European region, but the methods can be generalized to other regions. To account for seasonal dependence of the mean-shifts the correction was performed independently for each calendar month. In comparison to the ground-based reference the homogenised data record shows an improvement over the original data record in terms of anomaly correlation and bias. In general the method can also be applied for the adjustment of satellite datasets addressing other variables to bridge the gap between CDRs and near-real-time data.
Background: Vitamin D insufficiency has been associated with the occurrence of various types of cancer, but causal relationships remain elusive. We therefore aimed to determine the relationship between genetic determinants of vitamin D serum levels and the risk of developing hepatitis C virus (HCV)-related hepatocellular carcinoma (HCC).
Methodology/Principal Findings: Associations between CYP2R1, GC, and DHCR7 genotypes that are determinants of reduced 25-hydroxyvitamin D (25[OH]D3) serum levels and the risk of HCV-related HCC development were investigated for 1279 chronic hepatitis C patients with HCC and 4325 without HCC, respectively. The well-known associations between CYP2R1 (rs1993116, rs10741657), GC (rs2282679), and DHCR7 (rs7944926, rs12785878) genotypes and 25(OH)D3 serum levels were also apparent in patients with chronic hepatitis C. The same genotypes of these single nucleotide polymorphisms (SNPs) that are associated with reduced 25(OH)D3 serum levels were found to be associated with HCV-related HCC (P = 0.07 [OR = 1.13, 95% CI = 0.99–1.28] for CYP2R1, P = 0.007 [OR = 1.56, 95% CI = 1.12–2.15] for GC, P = 0.003 [OR = 1.42, 95% CI = 1.13–1.78] for DHCR7; ORs for risk genotypes). In contrast, no association between these genetic variations and liver fibrosis progression rate (P>0.2 for each SNP) or outcome of standard therapy with pegylated interferon-α and ribavirin (P>0.2 for each SNP) was observed, suggesting a specific influence of the genetic determinants of 25(OH)D3 serum levels on hepatocarcinogenesis.
Conclusions/Significance: Our data suggest a relatively weak but functionally relevant role for vitamin D in the prevention of HCV-related hepatocarcinogenesis.
The production cross section of electrons from semileptonic decays of beauty hadrons was measured at mid-rapidity (|y|<0.8) in the transverse momentum range 1<pT<8 GeV/c with the ALICE experiment at the CERN LHC in pp collisions at a center of mass energy √s=7 TeV using an integrated luminosity of 2.2 nb−1. Electrons from beauty hadron decays were selected based on the displacement of the decay vertex from the collision vertex. A perturbative QCD calculation agrees with the measurement within uncertainties. The data were extrapolated to the full phase space to determine the total cross section for the production of beauty quark–antiquark pairs.
The elliptic, v2, triangular, v3, and quadrangular, v4, azimuthal anisotropic flow coefficients are measured for unidentified charged particles, pions, and (anti-)protons in Pb–Pb collisions at √sNN=2.76 TeV with the ALICE detector at the Large Hadron Collider. Results obtained with the event plane and four-particle cumulant methods are reported for the pseudo-rapidity range |η|<0.8 at different collision centralities and as a function of transverse momentum, pT, out to pT=20 GeV/c. The observed non-zero elliptic and triangular flow depends only weakly on transverse momentum for pT>8 GeV/c. The small pT dependence of the difference between elliptic flow results obtained from the event plane and four-particle cumulant methods suggests a common origin of flow fluctuations up to pT=8 GeV/c. The magnitude of the (anti-)proton elliptic and triangular flow is larger than that of pions out to at least pT=8 GeV/c indicating that the particle type dependence persists out to high pT.
The inclusive transverse momentum (pT) distributions of primary charged particles are measured in the pseudo-rapidity range |η|<0.8 as a function of event centrality in Pb–Pb collisions at √sNN=2.76 TeV with ALICE at the LHC. The data are presented in the pT range 0.15<pT<50 GeV/c for nine centrality intervals from 70–80% to 0–5%. The results in Pb–Pb are presented in terms of the nuclear modification factor RAA using a pp reference spectrum measured at the same collision energy. We observe that the suppression of high-pT particles strongly depends on event centrality. The yield is most suppressed in central collisions (0–5%) with RAA≈0.13 at pT=6–7 GeV/c. Above pT=7 GeV/c, there is a significant rise in the nuclear modification factor, which reaches RAA≈0.4 for pT>30 GeV/c. In peripheral collisions (70–80%), only moderate suppression (RAA=0.6–0.7) and a weak pT dependence is observed. The measured nuclear modification factors are compared to other measurements and model calculations.