Refine
Document Type
- Article (2)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- Biological (1)
- Closure (1)
- Fistula (1)
- Guidelines (1)
- Intra-abdominal infection (1)
- Laparostomy (1)
- Mesh (1)
- Non-trauma (1)
- Nutrition (1)
- Open abdomen (1)
Institute
- Medizin (2)
Damage control resuscitation may lead to postoperative intra-abdominal hypertension or abdominal compartment syndrome. These conditions may result in a vicious, self-perpetuating cycle leading to severe physiologic derangements and multiorgan failure unless interrupted by abdominal (surgical or other) decompression. Further, in some clinical situations, the abdomen cannot be closed due to the visceral edema, the inability to control the compelling source of infection or the necessity to re-explore (as a “planned second-look” laparotomy) or complete previously initiated damage control procedures or in cases of abdominal wall disruption. The open abdomen in trauma and non-trauma patients has been proposed to be effective in preventing or treating deranged physiology in patients with severe injuries or critical illness when no other perceived options exist. Its use, however, remains controversial as it is resource consuming and represents a non-anatomic situation with the potential for severe adverse effects. Its use, therefore, should only be considered in patients who would most benefit from it. Abdominal fascia-to-fascia closure should be done as soon as the patient can physiologically tolerate it. All precautions to minimize complications should be implemented.
Uncalibrated semi-invasive continous monitoring of cardiac index (CI) has recently gained increasing interest. The aim of the present study was to compare the accuracy of CI determination based on arterial waveform analysis with transpulmonary thermodilution. Fifty patients scheduled for elective coronary surgery were studied after induction of anaesthesia and before and after cardiopulmonary bypass (CPB), respectively. Each patient was monitored with a central venous line, the PiCCO system, and the FloTrac/Vigileo-system. Measurements included CI derived by transpulmonary thermodilution and uncalibrated semi-invasive pulse contour analysis. Percentage changes of CI were calculated. There was a moderate, but significant correlation between pulse contour CI and thermodilution CI both before (r(2) = 0.72, P < 0.0001) and after (r(2) = 0.62, P < 0.0001) CPB, with a percentage error of 31% and 25%, respectively. Changes in pulse contour CI showed a significant correlation with changes in thermodilution CI both before (r(2) = 0.52, P < 0.0001) and after (r(2) = 0.67, P < 0.0001) CPB. Our findings demonstrated that uncalibrated semi-invasive monitoring system was able to reliably measure CI compared with transpulmonary thermodilution in patients undergoing elective coronary surgery. Furthermore, the semi-invasive monitoring device was able to track haemodynamic changes and trends.