(1) Background: A lesion within the dentato-rubro-olivary pathway (DROP) in the posterior fossa can cause secondary neurodegeneration of the inferior olivary nucleus: so-called hypertrophic olivary degeneration (HOD). The clinical syndrome of HOD occurs slowly over months and may be overlooked in progressive neuro-oncological diseases. Posterior fossa tumors are often located near these strategic structures. The goal of this study was to analyze the systematics of HOD occurrence in neuro-oncological patients.
(2) Methods: The neuroradiological database of the university healthcare center was scanned for HOD-related terms from 2010 to 2019. After excluding patients with other causes of HOD, 12 datasets from neuro-oncological patients were analyzed under predetermined criteria.
(3) Results: Patients received multimodal tumor treatments including neurosurgery, radiotherapy, and chemotherapy. HOD occurred both unilaterally (left n = 4; right n = 5) and bilaterally (n = 3). Though the mass effect of posterior fossa tumors had already affected strategic structures of the DROP, none of the patients showed signs of HOD on MRI until therapeutic measures including neurosurgery affecting the DROP were applied. HOD was visible on MRI within a median of 6 months after the neurosurgical intervention. In 67%, the presumed underlying surgical lesion in the DROP lay in the contralateral dentate nucleus.
(4) Conclusion: In a selected cohort of neuro-oncological patients, therapeutic lesions within the DROP were associated with HOD occurrence.
Cerebral radiation necrosis is a common complication of the radiotherapy of brain tumours that can cause significant mortality. Corticosteroids are the standard of care, but their efficacy is limited and the consequences of long-term steroid therapy are problematic, including the risk of adrenal insufficiency (AI). Off-label treatment with the vascular endothelial growth factor A antibody bevacizumab is highly effective in steroid-resistant radiation necrosis. Both the preservation of neural tissue integrity and the cessation of steroid therapy are key goals of bevacizumab treatment. However, the withdrawal of steroids may be impossible in patients who develop AI. In order to elucidate the frequency of AI in patients with cerebral radiation necrosis after treatment with corticosteroids and bevacizumab, we performed a retrospective study at our institution’s brain tumour centre. We obtained data on the tumour histology, age, duration and maximum dose of dexamethasone, radiologic response to bevacizumab, serum cortisol, and the need for hydrocortisone substitution for AI. We identified 17 patients with cerebral radiation necrosis who had received treatment with bevacizumab and had at least one available cortisol analysis. Fifteen patients (88%) had a radiologic response to bevacizumab. Five of the 17 patients (29%) fulfilled criteria for AI and required hormone substitution. Age, duration of dexamethasone treatment, and time since radiation were not statistically associated with the development of AI. In summary, despite the highly effective treatment of cerebral radiation necrosis with bevacizumab, steroids could yet not be discontinued due to the development of AI in roughly one-third of patients. Vigilance to spot the clinical and laboratory signs of AI and appropriate testing and management are, therefore, mandated.
Highlights
• The goal was to assess the intra- and inter-scanner reproducibility of qMRI data.
• Mean scan-rescan variations were not exceeding 2.14%.
• Mean inter-scanner model deviations were not exceeding 5.21%.
• Provided that identical acquisition sequences are used, discrepancies between qMRI data acquired with different scanner models are low.
Abstract
Background: Quantitative MRI (qMRI) techniques allow assessing cerebral tissue properties. However, previous studies on the accuracy of quantitative T1 and T2 mapping reported a scanner model bias of up to 10% for T1 and up to 23% for T2. Such differences would render multi-centre qMRI studies difficult and raise fundamental questions about the general precision of qMRI. A problem in previous studies was that different methods were used for qMRI parameter mapping or for measuring the transmitted radio frequency field B1 which is critical for qMRI techniques requiring corrections for B1 non-uniformities.
Aims: The goal was to assess the intra- and inter-scanner reproducibility of qMRI data at 3 T, using two different scanner models from the same vendor with exactly the same multiparametric acquisition protocol.
Methods: Proton density (PD), T1, T2* and T2 mapping was performed on healthy subjects and on a phantom, performing each measurement twice for each of two scanner models. Although the scanners had different hardware and software versions, identical imaging sequences were used for PD, T1 and T2* mapping, adapting the codes of an existing protocol on the older system line by line to match the software version of the newer scanner. For T2-mapping, the respective manufacturer’s sequence was used which depended on the software version. However, system-dependent corrections were carried out in this case. Reproducibility was assessed by average values in regions of interest.
Results: Mean scan-rescan variations were not exceeding 2.14%, with average values of 1.23% and 1.56% for the new and old system, respectively. Inter-scanner model deviations were not exceeding 5.21% with average values of about 2.2–3.8% for PD, 2.5–3.0% for T2*, 1.6–3.1% for T1 and 3.3–5.2% for T2.
Conclusions: Provided that identical acquisition sequences are used, discrepancies between qMRI data acquired with different scanner models are low. The level of systematic differences reported in this work may help to interpret multi-centre data.
The detection of cortical malformations in conventional MR images can be challenging. Prominent examples are focal cortical dysplasias (FCD), the most common cause of drug‐resistant focal epilepsy. The two main MRI hallmarks of cortical malformations are increased cortical thickness and blurring of the gray (GM) and white matter (WM) junction. The purpose of this study was to derive synthetic anatomies from quantitative T1 maps for the improved display of the above imaging characteristics in individual patients.
On the basis of a T1 map, a mask comprising pixels with T1 values characteristic for GM is created from which the local cortical extent (CE) is determined. The local smoothness (SM) of the GM‐WM junctions is derived from the T1 gradient. For display of cortical malformations, the resulting CE and SM maps serve to enhance local intensities in synthetic double inversion recovery (DIR) images calculated from the T1 map.
The resulting CE‐ and/or SM‐enhanced DIR images appear hyperintense at the site of cortical malformations, thus facilitating FCD detection in epilepsy patients. However, false positives may arise in areas with naturally elevated CE and/or SM, such as large GM structures and perivascular spaces.
In summary, the proposed method facilitates the detection of cortical abnormalities such as cortical thickening and blurring of the GM‐WM junction which are typical FCD markers. Still, subject motion artifacts, perivascular spaces, and large normal GM structures may also yield signal hyperintensity in the enhanced synthetic DIR images, requiring careful comparison with clinical MR images by an experienced neuroradiologist to exclude false positives.