Refine
Document Type
- Article (21)
Language
- English (21)
Has Fulltext
- yes (21)
Is part of the Bibliography
- no (21)
Keywords
- Musculoskeletal system (4)
- ergonomics (3)
- inertial motion capture (3)
- Healthy adults (2)
- Jaw (2)
- Knees (2)
- Legs (2)
- Myalgia (2)
- Postural control (2)
- kinematic analysis (2)
Institute
Traditional ergonomic risk assessment tools such as the Rapid Upper Limb Assessment (RULA) are often not sensitive enough to evaluate well-optimized work routines. An implementation of kinematic data captured by inertial sensors is applied to compare two work routines in dentistry. The surgical dental treatment was performed in two different conditions, which were recorded by means of inertial sensors (Xsens MVN Link). For this purpose, 15 (12 males/3 females) oral and maxillofacial surgeons took part in the study. Data were post processed with costume written MATLAB® routines, including a full implementation of RULA (slightly adjusted to dentistry). For an in-depth comparison, five newly introduced levels of complexity of the RULA analysis were applied, i.e., from lowest complexity to highest: (1) RULA score, (2) relative RULA score distribution, (3) RULA steps score, (4) relative RULA steps score occurrence, and (5) relative angle distribution. With increasing complexity, the number of variables times (the number of resolvable units per variable) increased. In our example, only significant differences between the treatment concepts were observed at levels that are more complex: the relative RULA step score occurrence and the relative angle distribution (level 4 + 5). With the presented approach, an objective and detailed ergonomic analysis is possible. The data-driven approach adds significant additional context to the RULA score evaluation. The presented method captures data, evaluates the full task cycle, and allows different levels of analysis. These points are a clear benefit to a standard, manual assessment of one main body position during a working task.
Triathletes often experience incoordination at the start of a transition run (TR); this is possibly reflected by altered joint kinematics. In this study, the first 20 steps of a run after a warm-up run (WR) and TR (following a 90 min cycling session) of 16 elite, male, long-distance triathletes (31.3 ± 5.4 years old) were compared. Measurements were executed on the competition course of the Ironman Frankfurt in Germany. Pacing and slipstream were provided by a cyclist in front of the runner. Kinematic data of the trunk and leg joints, step length, and step rate were obtained using the MVN Link inertial motion capture system by Xsens. Statistical parametric mapping was used to compare the active leg (AL) and passive leg (PL) phases of the WR and TR. In the TR, more spinal extension (~0.5–1°; p = 0.001) and rotation (~0.2–0.5°; p = 0.001–0.004), increases in hip flexion (~3°; ~65% AL−~55% PL; p = 0.001–0.004), internal hip rotation (~2.5°; AL + ~0–30% PL; p = 0.001–0.024), more knee adduction (~1°; ~80–95% AL; p = 0.001), and complex altered knee flexion patterns (~2–4°; AL + PL; p = 0.001–0.01) occurred. Complex kinematic differences between a WR and a TR were detected. This contributes to a better understanding of the incoordination in transition running.
Background; Musculoskeletal disorders (MSD) are a common health problem among dentists. Dental treatment is mainly performed in a sitting position. The aim of the study was to quantify the effect of different ergonomic chairs on the sitting position. In addition, it was tested if the sitting position of experienced workers is different from a non-dental group.
Methods; A total of 59 (28 m/31f) subjects, divided into two dentist groups according to their work experience (students and dentists (9 m/11f) < 10 years, dentists (9 m/10f) ≥ 10 years) and a control group (10 m/10f) were measured. A three-dimensional back scanner captured the bare back of all subjects sitting on six dentist’s chairs of different design. Initially, inter-group comparisons per chair, firstly in the habitual and secondly in the working postures, were carried out. Furthermore, inter-chair comparison was conducted for the habitual as well as for the working postures of all subjects and for each group. Finally, a comparison between the habitual sitting posture and the working posture for each respective chair (intra-chair comparison) was conducted (for all subjects and for each group). In addition, a subjective assessment of each chair was made.
For the statistical analysis, non-parametric tests were conducted and the level of significance was set at 5%.
Results: When comparing the three subject groups, all chairs caused a more pronounced spinal kyphosis in experienced dentists. In both conditions (habitual and working postures), a symmetrical sitting position was assumed on each chair.
The inter-chair comparisons showed no differences regarding the ergonomic design of the chairs. The significances found in the inter-chair comparisons were all within the measurementerror and could, therefore, be classified as clinically irrelevant.
The intra-chair comparison (habitual sitting position vs. working sitting position) illustrated position-related changes in the sagittal, but not in the transverse, plane. These changes were only position-related (forward leaned working posture) and were not influenced by the ergonomic sitting design of the respective chair. There are no differences between the groups in the subjective assessment of each chair.
Conclusions; Regardless of the group or the dental experience, the ergonomic design of the dentist’s chair had only a marginal influence on the upper body posture in both the habitual and working sitting postures. Consequently, the focus of the dentist’s chair, in order to minimize MSD, should concentrate on adopting a symmetrical sitting posture rather than on its ergonomic design.
Background: The standard electrode array for the MED-EL MAESTRO cochlear implant system is 31 mm in length which allows an insertion angle of approximately 720°. When fully inserted, this long electrode array is capable of stimulating the most apical region of the cochlea. No investigation has explored Electrically Evoked Compound Action Potential (ECAP) recordings in this region with a large number of subjects using a commercially available cochlear implant system. The aim of this study is to determine if certain properties of ECAP recordings vary, depending on the stimulation site in the cochlea. Methods: Recordings of auditory nerve responses were conducted in 67 subjects to demonstrate the feasibility of ECAP recordings using the Auditory Nerve Response Telemetry (ART™) feature of the MED-EL MAESTRO system software. These recordings were then analyzed based on the site of cochlear stimulation defined as basal, middle and apical to determine if the amplitude, threshold and slope of the amplitude growth function and the refractory time differs depending on the region of stimulation. Results: Findings show significant differences in the ECAP recordings depending on the stimulation site. Comparing the apical with the basal region, on average higher amplitudes, lower thresholds and steeper slopes of the amplitude growth function have been observed. The refractory time shows an overall dependence on cochlear region; however post-hoc tests showed no significant effect between individual regions. Conclusions :Obtaining ECAP recordings is also possible in the most apical region of the cochlea. However, differences can be observed depending on the region of the cochlea stimulated. Specifically, significant higher ECAP amplitude, lower thresholds and steeper amplitude growth function slopes have been observed in the apical region. These differences could be explained by the location of the stimulating electrode with respect to the neural tissue in the cochlea, a higher density, or an increased neural survival rate of neural tissue in the apex. Trial registration: The Clinical Investigation has the Competent Authority registration number DE/CA126/AP4/3332/18/05.
Rationale: Bronchiolitis obliterans syndrome (BOS) is a severe, chronic inflammation of the airways leading to an obstruction of the bronchioles. So far, there are only a few studies looking at the long‐term development of pulmonary impairment in children with BOS.
Objective: The objective of this study was to investigate the incidence and long‐term outcome of BOS in children who underwent allogeneic hematopoietic stem cell transplantation (HSCT).
Methods: Medical charts of 526 children undergoing HSCT in Frankfurt/Main, Germany between 2000 and 2017 were analyzed retrospectively and as a result, 14 patients with BOS were identified. A total of 271 lung functions (spirometry and body plethysmography), 26 lung clearance indices (LCI), and 46 chest high‐resolution computed tomography (HRCT) of these 14 patients with BOS were evaluated.
Results: Fourteen patients suffered from BOS after HSCT (2.7%), whereby three distinctive patterns of lung function impairment were observed: three out of 14 patients showed a progressive lung function decline; two died and one received a lung transplant. In five out of 14 patients with BOS persisted with a severe obstructive and secondarily restrictive pattern in lung function (forced vital capacity [FVC] < 60%, forced expiratory volume in 1 second [FEV1] < 50%, and FEV1/FVC < 0.7) and increased LCI (11.67‐20.9), six out of 14 patients recovered completely after moderate lung function impairment and signs of BOS on HRCT. Long‐term FVC in absolute numbers was increased indicating that the children still have lung growth.
Conclusion: Our results showed that the incidence of BOS in children is low. BOS was associated with high mortality and may lead to persistent obstructive lung disease; although, lung growth continued to exist.
Comparative values are essential for the classification of orthopedic abnormalities and the assessment of a necessary therapy. At present, reference values for the upper body posture for healthy, male adults exist for the age groups of 18–35, 31–40 and 41–50 years. However, corresponding data on the decade of 51 to 60 year-old healthy men are still lacking. 23 parameters of the upper body posture were analyzed in 102 healthy male participants aged 51–60 (55.36 ± 2.78) years. The average height was 180.76 ± 7.81 cm with a weight of 88.22 ± 14.57 kg. The calculated BMI was 26.96 ± 3.92 kg/m2. In the habitual, upright position, the bare upper body was scanned three-dimensionally using video raster stereography. Mean or median values, confidence intervals, tolerance ranges and group comparisons, as well as correlations of BMI and physical activity, were calculated for all parameters. The spinal column parameters exhibited a good exploration of the frontal plane in the habitual standing position. In the sagittal plane, a slight, ventral inclination of the trunk with an increased kyphosis angle of the thoracic spine and increased thoracic bending angle was observed. The parameters of the pelvis showed a pronounced symmetry with deviations from the 0° axis within the measurement error margin of 1 mm/1°. The scapula height together with the scapula angles of the right and left side described a slightly elevated position of the left shoulder compared to the right side. The upper body posture is influenced by parameters of age, height, weight and BMI. Primarily there are significant correlations to measurements of trunk lengths D (age: p ≤ 0.02, rho = -0.23; height: p ≤ 0.001, rho = 0.58; weight: p ≤ 0.001, rho = 0.33), trunk lengths S (age: p ≤ 0.01, rho = -0.27; height: p ≤ 0.001, rho = 0.58; weight: p ≤ 0.001, rho = 0.32), pelvic distance (height: p ≤ 0.01, rho = 0.26; weight: p ≤ 0.001, rho = 0.32; BMI: p ≤ 0.03, rho = 0.22) and scapula distance (weight: p ≤ 0.001, rho = .32; BMI: p ≤ 0.01, rho = 0.27), but also to sagittal parameters of trunk decline (weight: p ≤ 0.001, rho = -0.29; BMI: p ≤ 0.01, rho = -0.24), thoracic bending angle (height: p ≤ 0.01, rho = 0.27) and kyphosis angle (BMI: p ≤ 0.03, rho = 0.21). The upper body posture of healthy men between the ages of 51 and 60 years was axially almost aligned and balanced. With the findings of this investigation and the reference values obtained, suitable comparative values for use in clinical practice and for further scientific studies with the same experimental set-up have been established.
Background: The aim is to investigate to what extent the different oral protections compared to the habitual occlusion affect the upper body posture in statics and during taekwondo-specific movement.
Methods: 12 Taekwondoka (5 f/7 m) of German national team were measured by using a 3d back scanner and an ultrasonic distance measuring (upright stand, taekwondo attack and defense movement, two taekwondo specific combinations) in habitual occlusion, with a custom-made and ready-made mouth protection
Results: There are no significant changes in the upper body posture (p ≥ 0.05). Depending on the dynamic measurements, different significant reactions of the spinal position were found while wearing the custom made mouthguard or the ready-made mouthguard according to the conducted movement.
Conclusion: The measured changes in dynamic movements are not clinical relevant. Based on the positive responses from the participants, the custom-made mouth protection can be recommended combined with an individual analysis.
Objectives: Symmetrical dental occlusion blocking is used in dentistry as a quick diagnostic tool to test for potential influences of the craniomandibular system on body sway and weight distribution. This study presents the changes of body sway and pressure distribution in healthy subjects, free of a temporomandibular dysfunction (TMD). Immediate effects between occlusal blocking and rest position on body sway and body weight distribution in general, as well as for both genders and for four age decades will be evaluated.
Materials and methods: 725 (396f/329 m) subjects (neither subjective signs of TMD nor acute/chronic complaints in the musculoskeletal system) volunteered (21 to 60 years) while both genders were divided into four age groups according to decades. A pressure measuring platform was used. Body sway and weight distribution were recorded in two dental occlusion conditions (a) in rest position and (b) symmetrical blocking (bicuspid region) by cotton rolls.
Results: Both, the frontal sway and the sagittal sway reduced by 0.67 mm (t(724) = − 3.9 (p < 0.001)) and by 0.33 mm (t(724) = − 3.4 (p < 0.001)). The relative pressure under the left forefoot increased by 0.33% (t(724) = 2.88 (p < 0.001)) and the relative pressure overall under the forefoot increased by 0.67% (t(724) = − 3.4 (p < 0.001)). Gender-specific, age-specific and BMI-specific reactions could not be identified.
Conclusions: Subjects, free of any TMD and with no complaints of the musculoskeletal system, show small changes of the body sway and weight distribution when biting symmetrically on a cotton roll. These changes are independent of age, gender or body mass index (BMI). Due to the relative large sample size, the presented results can also be seen as norm values when body sway is used as an additional assessment of a TMD.
Standard values of the upper body posture in healthy adults with special regard to age, sex and BMI
(2023)
In order to classify and analyze the parameters of upper body posture in clinical or physiotherapeutic settings, a baseline in the form of standard values with special regard to age, sex and BMI is required. Thus, subjectively healthy men and women aged 21–60 years were measured in this project. The postural parameters of 800 symptom-free male (n = 397) and female (n = 407) volunteers aged 21–60 years (Ø♀: 39.7 ± 11.6, Ø ♂: 40.7 ± 11.5 y) were studied. The mean height of the men was 1.8 ± 0.07 m, with a mean body weight of 84.8 ± 13.1 kg and an average BMI of 26.0 ± 3.534 kg/m2. In contrast, the mean height of the women was 1.67 ± 0.06 m, with a mean body weight of 66.5 ± 12.7 kg and an average BMI of 23.9 ± 4.6 kg/m2. By means of video rasterstereography, a 3-dimensional scan of the upper back surface was measured when in a habitual standing position. The means or medians, confidence intervals, tolerance ranges, the minimum, 2.5, 25, 50, 75, 97.5 percentiles and the maximum, plus the kurtosis and skewness of the distribution, were calculated for all parameters. Additionally, ANOVA and a factor analyses (sex, BMI, age) were conducted. In both sexes across all age groups, balanced, symmetrical upper body statics were evident. Most strikingly, the females showed greater thoracic kyphosis and lumbar lordosis angles (kyphosis: Ø ♀ 56°, Ø♂ 51°; lordosis: Ø ♀ 49°, Ø♂ 32°) and lumbar bending angles (Ø ♀ 14°, Ø♂ 11°) than the males. The distance between the scapulae was more pronounced in men. These parameters also show an increase with age and BMI, respectively. Pelvic parameters were independent of age and sex. The upper body postures of women and men between the ages of 21 and 60 years were found to be almost symmetrical and axis-conforming with a positive correlation for BMI or age. Consequently, the present body posture parameters allow for comparisons with other studies, as well as for the evaluation of clinical (interim) diagnostics and applications.
Objective: The influence of the jaw position on postural control, body posture, walking and running pattern has been reported in the literature. All these movements have in common that a relatively small, but well controlled muscle activation is required. The induced effects on motor output through changed jaw positions have been small. Therefore, it has been questioned if it could still be observed in maximal muscle activation.
Method: Twenty-three healthy, mid age recreational runners (mean age = 34.0 ± 10.3 years) participated in this study. Three different jump tests (squat jump, counter movement jump, and drop jumps from four different heights) and three maximal strength tests (trunk flexion and extension, leg press of the right and left leg) were conducted. Four different dental occlusion conditions and an additional familiarization condition were tested. Subjects performed the tests on different days for which the four occlusion conditions were randomly changed.
Results: No familiarization effect was found. Occlusion conditions with a relaxation position and with a myocentric condylar position showed significantly higher values for several tests compared to the neutral condition and the maximal occlusion position. Significance was found in the squat jump, countermovement jump, the drop jump from 32cm and 40cm, trunk extension, leg press force and rate of force development. The effect due to the splint conditions is an improvement between 3% and 12% (min and max). No influence of the jaw position on symmetry or balance between extension and flexion muscle was found.
Conclusion: An influence of occlusion splints on rate of force development (RFD) and maximal strength tests could be confirmed. A small, but consistent increase in the performance parameters could be measured. The influence of the occlusion condition is most likely small compared to other influences as for example training status, age, gender and circadian rhythm.