Refine
Year of publication
Document Type
- Article (71)
- Preprint (2)
- Conference Proceeding (1)
Has Fulltext
- yes (74)
Is part of the Bibliography
- no (74)
Keywords
- Mammakarzinom (12)
- breast cancer (12)
- Behandlung (8)
- Metastasen (8)
- CDK4/6 (6)
- PD1/PDL1 (6)
- Prävention (6)
- Studien (6)
- prevention (6)
- treatment (6)
Institute
- Medizin (35)
- Physik (27)
- ELEMENTS (9)
- Biochemie und Chemie (6)
- Geowissenschaften (3)
- Biowissenschaften (1)
- Pharmazie (1)
- Senckenbergische Naturforschende Gesellschaft (1)
Purpose: Prostate specific antigen is not reliable in diagnosing prostate cancer (PCa), making the identification of novel, precise diagnostic biomarkers important. Since chemokines are associated with more aggressive disease and poor prognosis in diverse malignancies, we aimed to investigate the diagnostic relevance of chemokines in PCa.
Materials and methods: Preoperative and early postoperative serum samples were obtained from 39 consecutive PCa patients undergoing radical prostatectomy. Serum from 15 healthy volunteers served as controls. Concentrations of CXCL12, CXCL13, CX3CL1, CCL2, CCL5, and CCL20 were measured in serum by Luminex. The expression activity of CXCR3, CXCR4, CXCR5, CXCR7, CXCL12, CXCL13, CX3CR1, CXCL1, CCR2, CCR5, CCR6, CCR7, CCL2, and CCL5 mRNA was assessed in tumor and adjacent normal tissue of prostatectomy specimens by quantitative real-time polymerase chain reaction. The associations of these chemokines with clinical and histological parameters were tested.
Results: The gene expression activity of CCL2 and CCR6 was significantly higher in tumor tissue compared to adjacent normal tissue. CCL2 was also significantly higher in the blood samples of PCa patients, compared to controls. CCL5, CCL20, and CX3CL1 were lower in patient serum, compared to controls. CCR2 tissue mRNA was negatively correlated with the Gleason score and grading.
Conclusion: Chemokines are significantly modified during tumorigenesis of PCa, and CCL2 is a promising diagnostic biomarker.
Background: The objective of the STREAM Trial was to evaluate the effect of simulation training on process times in acute stroke care.
Methods: The multicenter prospective interventional STREAM Trial was conducted between 10/2017 and 04/2019 at seven tertiary care neurocenters in Germany with a pre- and post-interventional observation phase. We recorded patient characteristics, acute stroke care process times, stroke team composition and simulation experience for consecutive direct-to-center patients receiving intravenous thrombolysis (IVT) and/or endovascular therapy (EVT). The intervention consisted of a composite intervention centered around stroke-specific in situ simulation training. Primary outcome measure was the ‘door-to-needle’ time (DTN) for IVT. Secondary outcome measures included process times of EVT and measures taken to streamline the pre-existing treatment algorithm.
Results: The effect of the STREAM intervention on the process times of all acute stroke operations was neutral. However, secondary analyses showed a DTN reduction of 5 min from 38 min pre-intervention (interquartile range [IQR] 25–43 min) to 33 min (IQR 23–39 min, p = 0.03) post-intervention achieved by simulation-experienced stroke teams. Concerning EVT, we found significantly shorter door-to-groin times in patients who were treated by teams with simulation experience as compared to simulation-naive teams in the post-interventional phase (−21 min, simulation-naive: 95 min, IQR 69–111 vs. simulation-experienced: 74 min, IQR 51–92, p = 0.04).
Conclusion: An intervention combining workflow refinement and simulation-based stroke team training has the potential to improve process times in acute stroke care.
The title complex, [PdCl2(C18H15P)2]·0.5C6H6, has the PdII ion in a square-planar coordination mode (r.m.s. deviation for Pd, P and Cl atoms = 0.024 Å) with the PPh3 and Cl ligands mutually trans. The benzene solvent molecule is located about a crystallographic inversion centre. The title complex is isostructural with trans-dichloridobis(triphenylphosphane)palladium(II) 1,4-dichlorobenzene sesquisolvate [Kitano et al. (1983 [triangle]). Acta Cryst. C39, 1015–1017].
We measured the neutron capture cross sections of 69Ga and 71Ga for a quasi-stellar spectrum at kBT = 25 keV and a spectrum with a peak energy at 90 keV by the activation technique at the Joint Research Centre (JRC) in Geel, Belgium. Protons were provided by an electrostatic Van de Graaff accelerator to produce neutrons via the reaction 7Li(p,n). The produced activity was measured via the γ emission of the product nuclei by high-purity germanium detectors. We present preliminary results.
Aim: To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy (OC) and to assess the diagnostic yield.
Methods: This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy (CCE) following incomplete OC performed by an experienced gastroenterologist (> 1000 colonoscopies). Patients with stenosis were excluded. According to patient preferences, CCE was performed the following day (protocol A) after staying on clear liquids and 0.75 L Moviprep in the morning or within 30 d after new split-dose Moviprep (protocol B). Boosts consisted of 0.75 L and 0.25 L Moviprep, and phospho-soda was given as a rescue if the capsule was not excreted after seven hours.
Results: Seventy-four patients were analysed (51% of them in group A; 49% in group B). Bowel cleansing was adequate in 67% of cases, and CCE could visualize colonic segments missed by incomplete colonoscopy in 90% of patients under protocol A and 97% of patients under protocol B (P = 0.35, n.s.). Significant polyps including adenocarcinoma were detected in 24% of cases. Detection rates for all polyps and significant polyps per patient were similar in both protocols. Polyps were found predominantly in the right colon (86%) in segments that were not reached by OC. Extracolonic findings - such as reflux esophagitis, suspected Barrett esophagus, upper GI-bleeding, gastric polyps, gastric erosions and angiectasia - were detected in eight patients. PillCamColon2 capsule was retained in the ileum of one patient (1.4%) without symptoms and removed during an uneventful resection for unknown Crohn’s disease that was diagnosed as the cause of anemia, which was the indication for colonoscopy. CCE was well tolerated. One patient suffered from self-limiting vomiting after consuming the phospho-soda.
Conclusion: Second-generation CCE using a low-volume preparation is useful after incomplete OC, and it allows for the detection of additional relevant findings, but cleansing efficiency could be improved.
The neutron activation method is well-suited to investigate neutron-capture cross sections relevant for the main s-process component. Neutrons can be produced via the 7Li(p,n) reaction with proton energies of 1912 keV at e.g. Van de Graaff accelerators, which results in a quasi-Maxwellian spectrum of neutrons corresponding to a temperature of kBT = 25 keV. However, the weak s-process takes place in massive stars at temperatures between 25 and 90 keV. Simulations using the PINO code [2] suggest that a Maxwellian spectrum for higher energies, e.g. kBT = 90 keV, can be approximated by a linear combination of different neutron spectra. To validate the PINO code at proton energies Ep ≠ 1912 keV, neutron time-of-flight measurements were carried out at the PTB Ion Accelerator Facility (PIAF) at the Physikalisch-Technische Bundesanstalt in Braunschweig, Germany.
LISA, the Laser Interferometer Space Antenna, will usher in a new era in gravitational-wave astronomy. As the first anticipated space-based gravitational-wave detector, it will expand our view to the millihertz gravitational-wave sky, where a spectacular variety of interesting new sources abound: from millions of ultra-compact binaries in our Galaxy, to mergers of massive black holes at cosmological distances; from the beginnings of inspirals that will venture into the ground-based detectors' view to the death spiral of compact objects into massive black holes, and many sources in between. Central to realising LISA's discovery potential are waveform models, the theoretical and phenomenological predictions of the pattern of gravitational waves that these sources emit. This white paper is presented on behalf of the Waveform Working Group for the LISA Consortium. It provides a review of the current state of waveform models for LISA sources, and describes the significant challenges that must yet be overcome.
The quasi-free scattering reactions 11C(p, 2p) and 10,11,12C(p, pn) have been studied in inverse kinematics at beam energies of 300–400 MeV/u at the R3B-LAND setup. The outgoing proton-proton and protonneutron pairs were detected in coincidence with the reaction fragments in kinematically complete measurements. The efficiency to detect these pairs has been obtained from GEANT4 simulations which were tested using the 12C(p, 2p) and 12C(p, pn) reactions. Experimental cross sections and momentum distributions have been obtained and compared to DWIA calculations based on eikonal theory. The new results reported here are combined with previously published cross sections for quasi-free scattering from oxygen and nitrogen isotopes and together they enable a systematic study of the reduction of singleparticle strength compared to predictions of the shell model over a wide neutron-to-proton asymmetry range. The combined reduction factors show a weak or no dependence on isospin asymmetry, in contrast to the strong dependency reported in nucleon-removal reactions induced by nuclear targets at lower energies. However, the reduction factors for (p, 2p) are found to be ’significantly smaller than for (p, pn) reactions for all investigated nuclei.
NeuLAND (New Large-Area Neutron Detector) is the next-generation neutron detector for the R3B (Reactions with Relativistic Radioactive Beams) experiment at FAIR (Facility for Antiproton and Ion Research). NeuLAND detects neutrons with energies from 100 to 1000 MeV, featuring a high detection efficiency, a high spatial and time resolution, and a large multi-neutron reconstruction efficiency. This is achieved by a highly granular design of organic scintillators: 3000 individual submodules with a size of 5 × 5 × 250 cm3 are arranged in 30 double planes with 100 submodules each, providing an active area of 250 × 250 cm2 and a total depth of 3 m. The spatial resolution due to the granularity together with a time resolution of 150 ps ensures high-resolution capabilities. In conjunction with calorimetric properties, a multi-neutron reconstruction efficiency of 50% to 70% for four-neutron events will be achieved, depending on both the emission scenario and the boundary conditions allowed for the reconstruction method. We present in this paper the final design of the detector as well as results from test measurements and simulations on which this design is based.
The neutron-unbound isotope 13Be has been studied in several experiments using different reactions, different projectile energies, and different experimental setups. There is, however, no real consensus in the interpretation of the data, in particular concerning the structure of the low-lying excited states. Gathering new experimental information, which may reveal the 13Be structure, is a challenge, particularly in light of its bridging role between 12Be, where the N = 8 neutron shell breaks down, and the Borromean halo nucleus 14Be. The purpose of the present study is to investigate the role of bound excited states in the reaction product 12Be after proton knockout from 14B, by measuring coincidences between 12Be, neutrons, and γ rays originating from de-excitation of states fed by neutron decay of 13Be. The 13Be isotopes were produced in proton knockout from a 400 MeV/nucleon 14B beam impinging on a CH2 target. The 12 Be-n relative-energy spectrum d σ /d Ef n was obtained from coincidences between 12Be(g.s.) and a neutron, and also as threefold coincidences by adding γ rays, from the de-excitation of excited states in 12Be. Neutron decay from the first 5/2+ state in 13Be to the 2+ state in 12Be at 2.11 MeV is confirmed. An energy independence of the proton-knockout mechanism is found from a comparison with data taken with a 35 MeV/nucleon 14B beam. A low-lying p-wave resonance in 13Be(1/2−) is confirmed by comparing proton- and neutron-knockout data from 14B and 14Be.
Quasifree one-proton knockout reactions have been employed in inverse kinematics for a systematic study of the structure of stable and exotic oxygen isotopes at the R3B/LAND setup with incident beam energies in the range of 300–450 MeV/u. The oxygen isotopic chain offers a large variation of separation energies that allows for a quantitative understanding of single-particle strength with changing isospin asymmetry. Quasifree knockout reactions provide a complementary approach to intermediate-energy one-nucleon removal reactions. Inclusive cross sections for quasifree knockout reactions of the type AO(p,2p)A−1N have been determined and compared to calculations based on the eikonal reaction theory. The reduction factors for the single-particle strength with respect to the independent-particle model were obtained and compared to state-of-the-art ab initio predictions. The results do not show any significant dependence on proton-neutron asymmetry.
We measured the Coulomb dissociation of 16O into 4He and 12C at the R3B setup in a first campaign within FAIR Phase 0 at GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt. The goal was to improve the accuracy of the experimental data for the 12C(α,γ)16O fusion reaction and to reach lower center-ofmass energies than measured so far.
The experiment required beam intensities of 109 16O ions per second at an energy of 500 MeV/nucleon. The rare case of Coulomb breakup into 12C and 4He posed another challenge: The magnetic rigidities of the particles are so close because of the same mass-to-charge-number ratio A/Z = 2 for 16O, 12C and 4He. Hence, radical changes of the R3B setup were necessary. All detectors had slits to allow the passage of the unreacted 16O ions, while 4He and 12C would hit the detectors' active areas depending on the scattering angle and their relative energies. We developed and built detectors based on organic scintillators to track and identify the reaction products with sufficient precision.