Refine
Document Type
- Article (15)
Language
- English (15)
Has Fulltext
- yes (15)
Is part of the Bibliography
- no (15)
Keywords
- Acuris (2)
- clinical research (2)
- clinical study (2)
- dental implant (2)
- electrolytic cleaning (2)
- marginal bone loss (2)
- periimplantitis (2)
- Bacterial leakage (1)
- CAD/ CAM crown (1)
- CAD/CAM (1)
Institute
- Medizin (15)
Manufacturing processes of custom implant abutments may contaminate their surfaces with micro wear deposits and generic pollutants. Such particulate debris, if not removed, might be detrimental and provoke inflammatory reactions in peri-implant tissues. Although regulatory guidelines for adequate cleaning, disinfection, or sterilization exist, there does not appear to be a consistent application and data on the amount and extent of such contaminants is lacking. The aim of the present in vitro study was to evaluate the quality and quantity of processing-related surface contamination of computer-aided design/computer-aided manufacturing (CAD/CAM) abutments in the state of delivery and after ultrasonic cleaning. A total of 28 CAD/CAM monotype and hybrid abutments were cleaned and disinfected applying a three-stage ultrasonic protocol (Finevo protocol). Before and after cleaning, the chemical composition and the contamination of the abutments were assessed using scanning electron microscopy (SEM), dispersive X-ray spectroscopy(EDX),andcomputer-aidedplanimetricmeasurement(CAPM).Inthedeliverycondition, monotype abutments showed a significantly higher amount of debris compared to hybrid abutments (4.86±6.10% vs. 0.03 ± 0.03%, p < 0.001). The polishing process applied in the laboratory after bonding the hybrid abutment components reduces the surface roughness and thus contributes substantially to their purity. The extent of contamination caused by computer-aided manufacturing of custom abutments can be substantially minimized using a three-stage ultrasonic protocol.
Objectives: A conometric concept was recently introduced in which conical implant abutments hold the matching crown copings by friction alone, eliminating the need for cement or screws. The aim of this in vitro study was to assess the presence of microgap formation and bacterial leakage at the Acuris conometric restorative interface of three different implant abutment systems. Material and methods: A total of 75 Acuris samples of three implant-abutment systems (Ankylos, Astra Tech EV, Xive) were subjected to microbiological (n = 60) and scanning electron microscopic (SEM) investigation (n = 15). Bacterial migration into and out of the conical coupling system were analyzed in an anaerobic workstation for 48, 96, 144, and 192 h. Bacterial DNA quantification using qrt-PCR was performed at each time point. The precision of the conometric coupling and internal fit of cemented CAD/CAM crowns on corresponding Acuris TiN copings were determined by means of SEM. Results: qrt-PCR results failed to demonstrate microbial leakage from or into the Acuris system. SEM analysis revealed minute punctate microgaps at the apical aspect of the conometric junction (2.04 to 2.64 µm), while mean cement gaps of 12 to 145 µm were observed at the crown-coping interface. Conclusions: The prosthetic morse taper connection of all systems examined does not allow bacterial passage. Marginal integrity and internal luting gap between the ceramic crown and the coping remained within the clinically acceptable limits. Clinical relevance: Conometrically seated single crowns provide sufficient sealing efficiency, relocating potential misfits from the crown-abutment interface to the crown-coping interface.
Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10−4 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.
he aim of this study was to evaluate the effect of controlled intraoral grinding and polishing on the roughness of full-contour zirconia compared to classical veneered zirconia. Thirty bar-shaped zirconia specimens were fabricated and divided into two groups (n=15). Fifteen specimens (group 1) were glazed and 15 specimens (group 2) were veneered with feldspathic ceramic and then glazed. Prior to grinding, maximum roughness depth (Rmax) values were measured using a profilometer, 5 times per specimen. Simulated clinical grinding and polishing were performed on the specimens under water coolant for 15 s and 2 N pressure. For grinding, NTI diamonds burs with grain sizes of 20 µm, 10 µm, and 7.5 µm were used sequentially. The ground surfaces were polished using NTI kits with coarse, medium and fine polishers. After each step, Rmax values were determined. Differences between groups were examined using one-way analysis of variance (ANOVA). The roughness of group 1 was significantly lower than that of group 2. The roughness increased significantly after coarse grinding in both groups. The results after glazing were similar to those obtained after fine grinding for non-veneered zirconia. However, fine-ground veneered zirconia had significantly higher roughness than venerred, glazed zirconia. No significant difference was found between fine-polished and glazed zirconia, but after the fine polishing of veneered zirconia, the roughness was significantly higher than after glazing. It can be concluded that for full-contour zirconia, fewer defects and lower roughness values resulted after grinding and polishing compared to veneered zirconia. After polishing zirconia, lower roughness values were achieved compared to glazing; more interesting was that the grinding of glazed zirconia using the NTI three-step system could deliver smooth surfaces comparable to untreated glazed zirconia surfaces.
The objective of this systematic review was to assess tooth wear against ceramic crowns in posterior region in vitro and in vivo. An electronic PubMed search was conducted to identify studies on tooth wear against ceramic crowns in posterior region. The selected studies were analyzed in regard to type of crowns, natural antagonist, measuring protocol and outcome. From a yield of 1 000 titles, 43 articles were selected for full-text analysis; finally, no in vitro and only five in vivo studies met the inclusion criteria. As there is heterogeneity in design, used measuring method, ceramics and analysis-form, a meta-analysis was not possible. Results of these studies are very controversial which makes a scientifically valid comparison impossible. This review indicated that some all-ceramic crowns are as wear friendly as metal-ceramic crowns. Up to now, it has been impossible to associate tooth wear with any specific causal agent. The role of ceramic surface treatment that might be responsible for the changing in rate of tooth wear seems undetermined as yet through clinical trials. The literature reveals that studies on this topic are subject to a substantial amount of bias. Therefore, additional clinical studies, properly designed to diminish bias, are warranted.
Purpose: To evaluate the prevalence of peri‐implantitis (PI) and peri‐implant mucositis (PM) in a long‐term follow‐up with comparison among different PI and PM definitions, and to report on the incidence of PI.
Materials and Methods: In a retrospective clinical study five different PI and PM definitions were applied onto a population with 274 implants 17 to 23 years postimplant placement. Recommendations by the Eighth European Workshop on Periodontology (EWOP) were used as base reference. Clinical and radiological measurements were considered. Risk factors were evaluated in a regression analysis.
Results: After an average observation period of 18.9 years, 40.1% of the implants were diagnosed with PM and 15.0% with PI (Eighth EWOP). PI incidence reached 7.9% on implant level and 13.2% on patient level. Implants diagnosed with PI and progressive bone loss displayed exceptionally vertical bone defect configuration (BDC). Diabetes mellitus, smoking, regular maintenance, or a former periodontal infection did not show significant influence on the prevalence of peri‐implant diseases. Patients with bruxism displayed significantly less PM and PI.
Conclusions: Vertical BDC seems to correspond with active PI, wherefore we estimate such a defining factor of importance. Diagnosis of PM and evaluation of probing pocket depths might be only of descriptive interest as they could lead to false‐positive results.
Purpose: Scientific evidence is limited regarding the long-term (>10 years) outcomes of large enough numbers of implants (>500) to allow for reliable comparison of subgroups. The purpose of this study was to analyze the outcomes of dental implants placed in an active University Clinic setting and followed for up to 20 years.
Materials and Methods: Data documenting the implant placement, prosthetic reconstruction, and annual follow-up of patients treated at Frankfurt University were extracted from a Structured Query Language database and patients’ written records and evaluated statistically.
Results: Between April of 1991 and May of 2011, 12,737 ANKYLOS® (DENTSPLY Implants Manufacturing GmbH, Mannheim, Germany) implants were placed in 4,206 patients for a variety of clinical indications. The Kaplan–Meier cumulative survival rate (CSR) was 93.3% after 204 months. Most of the failures (198/1.6%) occurred during the first year after implant placement and before prosthesis delivery. A significantly higher (p < .001) number of implants placed in the mandible and in hard quality bone failed than those placed in the maxilla or in weak and normal quality bone. Female patients had significantly higher CSRs (93.7% 204 months) than male patients (92.8% 204 months/p = .029). The implants showed low rates of peri-implant bone loss after 204 months (horizontal: 21 mm: 85.7%, vertical: 21 mm: 85.2%).
Conclusion: ANKYLOS dental implants followed for up to 20 years have high CSRs and low rates of peri-implant bone loss.
Resorbable synthetic scaffolds are promising for different indications, espe- cially in the context of bone regeneration. However, they require additional biological components to enhance their osteogenic potential. In addition to different cell types, autologous blood-derived matrices offer many advantages to enhance the regenerative capacity of biomaterials. The present study aimed to analyze whether biologization of a PCL-mesh coated using differently centrifuged Platelet rich fibrin (PRF) matrices will have a positive influence on primary human osteoblasts activity in vitro. A polymeric resorbable scaffold (Osteomesh, OsteoporeTM (OP), Singapore) was combined with differently centrifuged PRF matrices to evaluate the additional influence of this biologization concept on bone regeneration in vitro. Peripheral blood of three healthy donors was used to gain PRF matrices centrifuged either at High (710× g, 8 min) or Low (44× g, 8 min) relative centrifugal force (RCF) according to the low speed centrifugation concept (LSCC). OP-PRF constructs were cultured with pOBs. POBs cultured on the uncoated OP served as a control. After three and seven days of cultivation, cell culture supernatants were collected to analyze the pOBs activity by determining the concentrations of VEGF, TGF-β1, PDGF, OPG, IL-8, and ALP- activity. Immunofluorescence staining was used to evaluate the Osteopontin expression of pOBs. After three days, the group of OP+PRFLow+pOBs showed significantly higher expression of IL-8, TGF-ß1, PDGF, and VEGF compared to the group of OP+PRFHigh+pOBs and OP+pOBs. Similar results were observed on day 7. Moreover, OP+PRFLow+pOBs exhibited significantly higher activity of ALP compared to OP+PRFHigh+pOBs and OP+pOBs. Immunofluorescence staining showed a higher number of pOBs adherent to OP+PRFLow+pOBs compared to the groups OP+PRFHigh+pOBs and OP+pOBs. To the best of our knowledge, this study is the first to investigate the osteoblasts activity when cultured on a PRF-coated PCL-mesh in vitro. The presented results suggest that PRFLow centrifuged according to LSCC exhibits autologous blood cells and growth factors, seem to have a significant effect on osteogenesis. Thereby, the combination of OP with PRFLow showed promising results to support bone regeneration. Further in vivo studies are required to verify the results and carry out potential results for clinical translation.
Purpose: Bacterial biofilms are a major problem in the treatment of infected dental and orthopedic implants. The purpose of this study is to investigate the cleaning effect of an electrolytic approach (EC) compared to a powder-spray system (PSS) on titanium surfaces. Materials and Methods: The tested implants (different surfaces and alloys) were collated into six groups and treated ether with EC or PSS. After a mature biofilm was established, the implants were treated, immersed in a nutritional solution, and streaked on Columbia agar. Colony-forming units (CFUs) were counted after breeding and testing (EC), and control (PSS) groups were compared using a paired sample t-test. Results: No bacterial growth was observed in the EC groups. After thinning to 1:1,000,000, 258.1 ± 19.9 (group 2), 264.4 ± 36.5 (group 4), and 245.3 ± 40.7 (group 6) CFUs could be counted in the PSS groups. The difference between the electrolytic approach (test groups 1, 3, and 5) and PSS (control groups 2, 4, and 6) was statistically extremely significant (p-value < 2.2 × 10−16). Conclusion: Only EC inactivated the bacterial biofilm, and PSS left reproducible bacteria behind. Within the limits of this in vitro test, clinical relevance could be demonstrated.
The aim of this systematic review and meta-analysis was to compare the peri-implant vertical bone loss of immediate loading of implant crowns using the one abutment at one time (AOT) protocol and implants with abutment removal (AR). This systematic review with meta-analysis was reported according to the PRISMA statement, with guidance from the Cochrane Collaboration Handbook. A total of 103 publications were identified in the PubMed database and reference lists of examined articles. After the screening of titles and abstracts, the eligibility of eight full-text articles was assessed. Five studies published between 2010 and 2015 were included in the meta-analysis. There was less peri-implant vertical bone loss at implants using an AOT protocol than at implants using AR protocol (WMD -0.19, 95% CI -0.26 to -0.13; p<0.0001; random-effects model). In conclusion, the use of the AOT protocol with platform-switched Morse implants results in less bone loss than do AR procedures, but this effect may not be clinically relevant. The preservation of marginal bone level achieved with the AOT protocol may not enhance the aesthetics. These results should be interpreted with caution.