Refine
Year of publication
Document Type
- Article (751)
- Preprint (720)
- Conference Proceeding (7)
- Working Paper (2)
- Book (1)
- Doctoral Thesis (1)
- Other (1)
- Part of Periodical (1)
Has Fulltext
- yes (1484)
Is part of the Bibliography
- no (1484)
Keywords
- Heavy Ion Experiments (21)
- Hadron-Hadron Scattering (11)
- Hadron-Hadron scattering (experiments) (11)
- LHC (9)
- Heavy-ion collision (6)
- immunotherapy (5)
- ALICE experiment (4)
- CIK cells (4)
- Collective Flow (4)
- HIV (4)
Institute
- Physik (1194)
- Frankfurt Institute for Advanced Studies (FIAS) (994)
- Informatik (921)
- Medizin (177)
- Geowissenschaften (23)
- Biowissenschaften (6)
- Senckenbergische Naturforschende Gesellschaft (6)
- Biochemie und Chemie (5)
- Informatik und Mathematik (5)
- Institut für Ökologie, Evolution und Diversität (5)
Background: Glioblastoma (GBM) is a cancer type with high thrombogenic potential and GBM patients are therefore at a particularly high risk for thrombotic events. To date only limited data on anticoagulation management after pulmonary embolism (PE) in GBM is available and the sporadic use of DOACs remains off-label.
Methods: A retrospective cohort analysis of patients with GBM and postoperative, thoracic CT-scan confirmed, PE was performed. Clinical course, follow-up at 6 and 12 months and the overall survival (OS) were evaluated using medical charts and neuroradiological data.
Results: Out of 584 GBM patients, 8% suffered from postoperative PE. Out of theses, 30% received direct oral anticoagulants (DOACs) and 70% low-molecular-weight heparin (LMWH) for therapeutic anticoagulation. There was no significant difference in major intracranial hemorrhage (ICH), re-thrombosis or re-embolism between the two cohorts. Although statistically non-significant, a tendency to reduced mRS at 6- and 12 months was observed in the LMWH cohort. Furthermore, patients receiving DOACs had a statistical benefit in OS.
Conclusion: In our analysis DOACs showed a satisfactory safety profile in terms of major ICH, re-thrombosis and re-embolism compared to LMWH in GBM patients with postoperative PE. Prospective, randomized trials are urgent to evaluate DOACs for therapeutic anticoagulation in GBM patients with PE.
Background: Since sorafenib has shown activity in different tumour types and gemcitabine regimens improved the outcome for biliary tract cancer (BTC) patients, we evaluated first-line gemcitabine plus sorafenib in a double-blind phase II study.
Patients and methods: 102 unresectable or metastatic BTC patients with histologically proven adenocarcinoma of gallbladder or intrahepatic bile ducts, Eastern Cooperative Oncology Group (ECOG) 0–2 were randomised to gemcitabine (1000 mg/m2 once weekly, first 7-weeks + 1-week rest followed by once 3-weeks + 1-week rest) plus sorafenib (400 mg twice daily) or placebo. Treatment continued until progression or unacceptable toxicity. Tumour samples were prospectively stained for sorafenib targets and potential biomarkers. Serum samples (first two cycles) were measured for vascular endothelial growth factors (VEGFs), vascular endothelial growth factor receptor 2 (VEGFR-2) and stromal cell-derived factor 1 (SDF1)α by enzyme-linked immunosorbent assay (ELISA).
Results: Gemcitabine plus sorafenib was generally well tolerated. Four and three patients achieved partial responses in the sorafenib and placebo groups, respectively. There was no difference in the primary end-point, median progression-free survival (PFS) for gemcitabine plus sorafenib versus gemcitabine plus placebo (3.0 versus 4.9 months, P = 0.859), and no difference for median overall survival (OS) (8.4 versus 11.2 months, P = 0.775). Patients with liver metastasis after resection of primary BTC survived longer with sorafenib (P = 0.019) compared to placebo. Patients who developed hand-foot syndrome (HFS) showed longer PFS and OS than patients without HFS. Two sorafenib targets, VEGFR-2 and c-kit, were not expressed in BTC samples. VEGFR-3 and Hif1α were associated with lymph node metastases and T stage. Absence of PDGFRβ expression correlated with longer PFS.
Conclusion: The addition of sorafenib to gemcitabine did not demonstrate improved efficacy in advanced BTC patients. Biomarker subgroup analysis suggested that some patients might benefit from combined treatment.
The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.
Major mood disorders, which primarily include bipolar disorder and major depressive disorder, are the leading cause of disability worldwide and pose a major challenge in identifying robust risk genes. Here, we present data from independent large-scale clinical data sets (including 29 557 cases and 32 056 controls) revealing brain expressed protocadherin 17 (PCDH17) as a susceptibility gene for major mood disorders. Single-nucleotide polymorphisms (SNPs) spanning the PCDH17 region are significantly associated with major mood disorders; subjects carrying the risk allele showed impaired cognitive abilities, increased vulnerable personality features, decreased amygdala volume and altered amygdala function as compared with non-carriers. The risk allele predicted higher transcriptional levels of PCDH17 mRNA in postmortem brain samples, which is consistent with increased gene expression in patients with bipolar disorder compared with healthy subjects. Further, overexpression of PCDH17 in primary cortical neurons revealed significantly decreased spine density and abnormal dendritic morphology compared with control groups, which again is consistent with the clinical observations of reduced numbers of dendritic spines in the brains of patients with major mood disorders. Given that synaptic spines are dynamic structures which regulate neuronal plasticity and have crucial roles in myriad brain functions, this study reveals a potential underlying biological mechanism of a novel risk gene for major mood disorders involved in synaptic function and related intermediate phenotypes.
Accurate measurement of the standard 235U(n,f) cross section from thermal to 170 keV neutron energy
(2020)
An accurate measurement of the 235U(n,f) cross section from thermal to 170 keV of neutron energy has recently been performed at n_TOF facility at CERN using 6Li(n,t)4He and 10B(n,α)7Li as references. This measurement has been carried out in order to investigate a possible overestimation of the 235U fission cross section evaluation provided by most recent libraries between 10 and 30 keV. A custom experimental apparatus based on in-beam silicon detectors has been used, and a Monte Carlo simulation in GEANT4 has been employed to characterize the setup and calculate detectors efficiency. The results evidenced the presence of an overestimation in the interval between 9 and 18 keV and the new data may be used to decrease the uncertainty of 235U(n,f) cross section in the keV region.
233U is the fissile nuclei in the Th-U fuel cycle with a particularily small neutron capture cross setion which is on average about one order of magnitude lower than its fission cross section. Hence, the measurement of the 233U(n, γ) cross section relies on a method to accurately distinguish between capture and fission γ-rays. A measurement of the 233U α-ratio has been performed at the n_TOF facility at CERN using a so-called fission tagging setup, coupling n_TOF 's Total Absorption Calorimeter with a novel fission chamber to tag the fission γ-rays. The experimental setup is described and essential parts of the analysis are discussed. Finally, a preliminary 233U α-ratio is presented.
We have measured the capture cross section of the 155Gd and 157Gd isotopes between 0.025 eV and 1 keV. The capture events were recorded by an array of 4 C6D6 detectors, and the capture yield was deduced exploiting the total energy detection system in combination with the Pulse Height Weighting Techniques. Because of the large cross section around thermal neutron energy, 4 metallic samples of different thickness were used to prevent problems related to self-shielding. The samples were isotopically enriched, with a cross contamination of the other isotope of less than 1.14%. The capture yield was analyzed with an R-Matrix code to describe the cross section in terms of resonance parameters. Near thermal energies, the results are significantly different from evaluations and from previous time-of-flight experiments. The data from the present measurement at n_TOF are publicly available in the experimental nuclear reaction database EXFOR.
Measurement of the 244Cm and 246Cm neutron-induced capture cross sections at the n_TOF facility
(2019)
The neutron capture reactions of the 244Cm and 246Cm isotopes open the path for the formation of heavier Cm isotopes and heavier elements such as Bk and Cf in a nuclear reactor. In addition, both isotopes belong to the minor actinides with a large contribution to the decay heat and to the neutron emission in irradiated fuels. There are only two previous 244Cm and 246Cm capture cross section measurements: one in 1969 using a nuclear explosion [1] and the most recent data measured at J-PARC in 2010 [2]. The data for both isotopes are very scarce due to the difficulties in performing the measurements: high intrinsic activity of the samples and limited facilities capable of providing isotopically enriched samples.
We have measured both neutron capture cross sections at the n_TOF Experimental Area 2 (EAR-2) with three C6 D6 detectors and also at Area 1 (EAR-1) with the TAC. Preliminary results assessing the quality and limitations (back-ground subtraction, measurement technique and counting statistics) of this new experimental datasets are presented and discussed.
233U is of key importance among the fissile nuclei in the Th-U fuel cycle. A particularity of 233U is its small neutron capture cross-section, which is on average about one order of magnitude lower than the fission cross-section. The accuracy in the measurement of the 233U capture cross-section depends crucially on an efficient capture-fission discrimination, thus a combined set-up of fission and γ-detectors is needed. A measurement of the 233U capture cross-section and capture-to-fission ratio was performed at the CERN n_TOF facility. The Total Absorption Calorimeter (TAC) of n_TOF was employed as γ-detector coupled with a novel compact ionization chamber as fission detector. A brief description of the experimental set-up will be given, and essential parts of the analysis procedure as well as the preliminary response of the set-up to capture are presented and discussed.
New neutron cross section measurements of minor actinides have been performed recently in order to reduce the uncertainties in the evaluated data, which is important for the design of advanced nuclear reactors and, in particular, for determining their performance in the transmutation of nuclear waste. We have measured the 241Am(n,γ) cross section at the n_TOF facility between 0.2 eV and 10 keV with a BaF2 Total Absorption Calorimeter, and the analysis of the measurement has been recently concluded. Our results are in reasonable agreement below 20 eV with the ones published by C. Lampoudis et al. in 2013, who reported a 22% larger capture cross section up to 110 eV compared to experimental and evaluated data published before. Our results also indicate that the 241Am(n,γ) cross section is underestimated in the present evaluated libraries between 20 eV and 2 keV by 25%, on average, and up to 35% for certain evaluations and energy ranges.