Refine
Year of publication
Has Fulltext
- yes (1046)
Is part of the Bibliography
- no (1046)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron Scattering (11)
- Hadron-Hadron scattering (experiments) (11)
- LHC (9)
- Heavy-ion collision (6)
- ALICE experiment (4)
- Collective Flow (4)
- Jets (4)
- Quark-Gluon Plasma (4)
- ALICE (3)
Institute
- Physik (1029)
- Frankfurt Institute for Advanced Studies (FIAS) (945)
- Informatik (905)
- Medizin (9)
- Informatik und Mathematik (3)
- Hochschulrechenzentrum (2)
- Biochemie und Chemie (1)
- Biochemie, Chemie und Pharmazie (1)
- Biodiversität und Klima Forschungszentrum (BiK-F) (1)
- ELEMENTS (1)
- Geowissenschaften / Geographie (1)
- Institut für Ökologie, Evolution und Diversität (1)
- Neuere Philologien (1)
Copper perchlorophthalocyanine (CuPcCl16, CuC32N8Cl16, Pigment Green 7) is one of the commercially most important green pigments. The compound is a nanocrystalline fully insoluble powder. Its crystal structure was first addressed by electron diffraction in 1972 [Uyeda et al. (1972). J. Appl. Phys. 43, 5181–5189]. Despite the commercial importance of the compound, the crystal structure remained undetermined until now. Using a special vacuum sublimation technique, micron-sized crystals could be obtained. Three-dimensional electron diffraction (3D ED) data were collected in two ways: (i) in static geometry using a combined stage-tilt/beam-tilt collection scheme and (ii) in continuous rotation mode. Both types of data allowed the crystal structure to be solved by direct methods. The structure was refined kinematically with anisotropic displacement parameters for all atoms. Due to the pronounced crystal mosaicity, a dynamic refinement was not feasible. The unit-cell parameters were verified by Rietveld refinement from powder X-ray diffraction data. The crystal structure was validated by many-body dispersion density functional theory (DFT) calculations. CuPcCl16 crystallizes in the space group C2/m (Z = 2), with the molecules arranged in layers. The structure agrees with that proposed in 1972.
Background: School attendance during the COVID-19 pandemic is intensely debated.
Aim: In November 2020, we assessed SARS-CoV-2 infections and seroreactivity in 24 randomly selected school classes and connected households in Berlin, Germany.
Methods: We collected oro-nasopharyngeal swabs and blood samples, examining SARS-CoV-2 infection and IgG antibodies by RT-PCR and ELISA. Household members self-swabbed. We assessed individual and institutional prevention measures. Classes with SARS-CoV-2 infection and connected households were retested after 1 week.
Results: We examined 1,119 participants, including 177 primary and 175 secondary school students, 142 staff and 625 household members. SARS-CoV-2 infection occurred in eight classes, affecting each 1–2 individuals. Infection prevalence was 2.7% (95% confidence interval (CI): 1.2–5.0; 9/338), 1.4% (95% CI: 0.2–5.1; 2/140), and 2.3% (95% CI: 1.3–3.8; 14/611) among students, staff and household members. Six of nine infected students were asymptomatic at testing. We detected IgG antibodies in 2.0% (95%CI: 0.8–4.1; 7/347), 1.4% (95% CI: 0.2–5.0; 2/141) and 1.4% (95% CI: 0.6–2.7; 8/576). Prevalence increased with inconsistent facemask-use in school, walking to school, and case-contacts outside school. For three of nine households with infection(s), origin in school seemed possible. After 1 week, no school-related secondary infections appeared in affected classes; the attack rate in connected households was 1.1%.
Conclusion: School attendance under rigorously implemented preventive measures seems reasonable. Balancing risks and benefits of school closures need to consider possible spill-over infection into households. Deeper insight is required into the infection risks due to being a schoolchild vs attending school.
Background: School attendance during the SARS-CoV-2 pandemic is intensely debated. Modelling studies suggest that school closures contribute to community transmission reduction. However, data among school-attending students and staff are scarce. In November 2020, we examined SARS-CoV-2 infections and seroreactivity in 24 randomly selected school classes and connected households in Berlin, Germany.
Methods: Students and school staff were examined, oro-nasopharyngeal swabs and blood samples collected, and SARS-CoV-2 infection and IgG antibodies detected by RT-PCR and ELISA. Household members performed self-swabs. Individual and institutional infection prevention and control measures were assessed. Classes with SARS-CoV-2 infection and connected household members were re-tested after one week.
Findings: 1119 participants were examined, including 177 primary and 175 secondary school students, 142 staff, and 625 household members. Participants reported mainly cold symptoms (19·4%). SARS-CoV-2 infection occurred in eight of 24 classes affecting each 1-2 individuals. Infection prevalence was 2·7% (95%CI; 1·2-5·0%; 9/338), 1·4% (0·2-5·1%; 2/140), and 2·3% (1·3-3·8%; 14/611) among students, staff and household members, respectively, including quarantined persons. Six of nine infected students were asymptomatic. Prevalence increased with inconsistent facemask use in school, way to school on foot, and case-contacts outside school. IgG antibodies were detected in 2·0% (0·8-4·1%; 7/347), 1·4% (0·2-5·0%; 2/141) and 1·4% (0·6-2·7%; 8/576), respectively. For three of nine households with infection(s) detected at cross-sectional assessment, origin in school seemed possible. After one week, no school-related, secondary infections appeared in affected classes; the attack rate in connected households was 1·1%.
Interpretation: These data suggest that school attendance under preventive measures is feasible, provided their rigorous implementation. In balancing threats and benefits of open versus closed schools during the pandemic, parents and society need to consider possible spill-overs into their households. Deeper insight is needed into the infection risks due to being a schoolchild as compared to attending school.
73Ge(n, γ ) cross sections were measured at the neutron time-of-flight facility n_TOF at CERN up to neutron energies of 300 keV, providing for the first time experimental data above 8 keV. Results indicate that the stellar cross section at kT = 30 keV is 1.5 to 1.7 times higher than most theoretical predictions. The new cross sections result in a substantial decrease of 73Ge produced in stars, which would explain the low isotopic abundance of 73Ge in the solar system.
he study of the resonant structures in neutron-nucleus cross-sections, and therefore of the compound-nucleus reaction mechanism, requires spectroscopic measurements to determine with high accuracy the energy of the neutron interacting with the material under study.
To this purpose, the neutron time-of-flight facility n_TOF has been operating since 2001 at CERN. Its characteristics, such as the high intensity instantaneous neutron flux, the wide energy range from thermal to few GeV, and the very good energy resolution, are perfectly suited to perform high-quality measurements of neutron-induced reaction cross sections. The precise and accurate knowledge of these cross sections plays a fundamental role in nuclear technologies, nuclear astrophysics and nuclear physics.
Two different measuring stations are available at the n_TOF facility, called EAR1 and EAR2, with different characteristics of intensity of the neutron flux and energy resolution. These experimental areas, combined with advanced detection systems lead to a great flexibility in performing challenging measurement of high precision and accuracy, and allow the investigation isotopes with very low cross sections, or available only in small quantities, or with very high specific activity.
The characteristics and performances of the two experimental areas of the n_TOF facility will be presented, together with the most important measurements performed to date and their physics case. In addition, the significant upcoming measurements will be introduced.
Above 1 MeV of incident neutron energy the fission fragment angular distribution (FFAD) has generally a strong anisotropic behavior due to the combination of the incident orbital momentum and the intrinsic spin of the fissioning nucleus. This effect has to be taken into account for the efficiency estimation of devices used for fission cross section measurements. In addition it bears information on the spin deposition mechanism and on the structure of transitional states. We designed and constructed a detection device, based on Parallel Plate Avalanche Counters (PPAC), for measuring the fission fragment angular distributions of several isotopes, in particular 232Th. The measurement has been performed at n_TOF at CERN taking advantage of the very broad energy spectrum of the neutron beam. Fission events were recognized by back to back detection in coincidence in two position-sensitive detectors surrounding the targets. The detection efficiency, depending mostly on the stopping of fission fragments in backings and electrodes, has been computed with a Geant4 simulation and validated by the comparison to the measured case of 235U below 3 keV where the emission is isotropic. In the case of 232Th, the result is in good agreement with previous data below 10 MeV, with a good reproduction of the structures associated to vibrational states and the opening of second chance fission. In the 14 MeV region our data are much more accurate than previous ones which are broadly scattered.
As language rhythm relies partly on general acoustic properties, such as intensity and duration, mastering two languages with distinct rhythmic properties (i.e., stress position) may enhance musical rhythm perception. We investigated whether second language (L2) competence affects musical rhythm aptitude in Turkish early (TELG) and late learners (TLLG) of German in comparison to German monolingual speakers (GMC). To account for inter-individual differences, we measured participants’ short-term and working memory capacity, melodic aptitude, and time they spent listening to music. Both L2 speaker groups perceived rhythmic variations significantly better than monolinguals. No differences were found between early and late learners’ performances. Our findings suggest that mastering two languages with different rhythmic properties enhances musical rhythm perception, providing further evidence of cognitive share between language and music.
The neutron capture cross section of 58Ni was measured at the neutron time of flight facility n_TOF at CERN, from 27 meV to 400 keV neutron energy. Special care has been taken to identify all the possible sources of background, with the so-called neutron background obtained for the first time using high-precision GEANT4 simulations. The energy range up to 122 keV was treated as the resolved resonance region, where 51 resonances were identified and analyzed by a multilevel R-matrix code SAMMY. Above 122 keV the code SESH was used in analyzing the unresolved resonance region of the capture yield. Maxwellian averaged cross sections were calculated in the temperature range of kT = 5 – 100 keV, and their astrophysical implications were investigated.
Aims: Carotid intima media thickness (CIMT) predicts cardiovascular (CVD) events, but the predictive value of CIMT change is debated. We assessed the relation between CIMT change and events in individuals at high cardiovascular risk.
Methods and results: From 31 cohorts with two CIMT scans (total n = 89070) on average 3.6 years apart and clinical follow-up, subcohorts were drawn: (A) individuals with at least 3 cardiovascular risk factors without previous CVD events, (B) individuals with carotid plaques without previous CVD events, and (C) individuals with previous CVD events. Cox regression models were fit to estimate the hazard ratio (HR) of the combined endpoint (myocardial infarction, stroke or vascular death) per standard deviation (SD) of CIMT change, adjusted for CVD risk factors. These HRs were pooled across studies.
In groups A, B and C we observed 3483, 2845 and 1165 endpoint events, respectively. Average common CIMT was 0.79mm (SD 0.16mm), and annual common CIMT change was 0.01mm (SD 0.07mm), both in group A. The pooled HR per SD of annual common CIMT change (0.02 to 0.43mm) was 0.99 (95% confidence interval: 0.95–1.02) in group A, 0.98 (0.93–1.04) in group B, and 0.95 (0.89–1.04) in group C. The HR per SD of common CIMT (average of the first and the second CIMT scan, 0.09 to 0.75mm) was 1.15 (1.07–1.23) in group A, 1.13 (1.05–1.22) in group B, and 1.12 (1.05–1.20) in group C.
Conclusions: We confirm that common CIMT is associated with future CVD events in individuals at high risk. CIMT change does not relate to future event risk in high-risk individuals.