Refine
Year of publication
Document Type
- Preprint (615)
- Article (435)
- Conference Proceeding (1)
- Report (1)
- Working Paper (1)
Has Fulltext
- yes (1053)
Is part of the Bibliography
- no (1053)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron scattering (experiments) (11)
- Hadron-Hadron Scattering (8)
- Heavy-ion collision (5)
- Collective Flow (4)
- Quark-Gluon Plasma (4)
- Jets (3)
- Jets and Jet Substructure (3)
- (surface) partial differential equations (2)
- 3D spatio-temporal resolved mathematical models (2)
Institute
- Physik (959)
- Frankfurt Institute for Advanced Studies (FIAS) (857)
- Informatik (826)
- Medizin (66)
- Geowissenschaften (9)
- Biowissenschaften (5)
- ELEMENTS (3)
- Informatik und Mathematik (3)
- Institut für Ökologie, Evolution und Diversität (3)
- Biochemie und Chemie (2)
- Biochemie, Chemie und Pharmazie (2)
- Georg-Speyer-Haus (2)
- Hochschulrechenzentrum (2)
- Senckenbergische Naturforschende Gesellschaft (2)
- Biodiversität und Klima Forschungszentrum (BiK-F) (1)
- Center for Financial Studies (CFS) (1)
- Extern (1)
- Geographie (1)
- Goethe-Zentrum für Wissenschaftliches Rechnen (G-CSC) (1)
- House of Finance (HoF) (1)
- MPI für Hirnforschung (1)
- Pharmazie (1)
- Psychologie und Sportwissenschaften (1)
- Sonderforschungsbereiche / Forschungskollegs (1)
- Sportwissenschaften (1)
- Sustainable Architecture for Finance in Europe (SAFE) (1)
- Wirtschaftswissenschaften (1)
Simple Summary: Acute myeloid leukemia (AML) is a genetically heterogeneous disease. Clinical phenotypes of frequent mutations and their impact on patient outcome are well established. However, the role of rare mutations often remains elusive. We retrospectively analyzed 1529 newly diagnosed and intensively treated AML patients for mutations of BCOR and BCORL1. We report a distinct co-mutational pattern that suggests a role in disease progression rather than initiation, especially affecting mechanisms of DNA-methylation. Further, we found loss-of-function mutations of BCOR to be independent markers of poor outcomes in multivariable analysis. Therefore, loss-of-function mutations of BCOR need to be considered for AML management, as they may influence risk stratification and subsequent treatment allocation.
Abstract: Acute myeloid leukemia (AML) is characterized by recurrent genetic events. The BCL6 corepressor (BCOR) and its homolog, the BCL6 corepressor-like 1 (BCORL1), have been reported to be rare but recurrent mutations in AML. Previously, smaller studies have reported conflicting results regarding impacts on outcomes. Here, we retrospectively analyzed a large cohort of 1529 patients with newly diagnosed and intensively treated AML. BCOR and BCORL1 mutations were found in 71 (4.6%) and 53 patients (3.5%), respectively. Frequently co-mutated genes were DNTM3A, TET2 and RUNX1. Mutated BCORL1 and loss-of-function mutations of BCOR were significantly more common in the ELN2017 intermediate-risk group. Patients harboring loss-of-function mutations of BCOR had a significantly reduced median event-free survival (HR = 1.464 (95%-Confidence Interval (CI): 1.005–2.134), p = 0.047), relapse-free survival (HR = 1.904 (95%-CI: 1.163–3.117), p = 0.01), and trend for reduced overall survival (HR = 1.495 (95%-CI: 0.990–2.258), p = 0.056) in multivariable analysis. Our study establishes a novel role for loss-of-function mutations of BCOR regarding risk stratification in AML, which may influence treatment allocation.
Simple Summary: Treatment of metastatic renal cell carcinoma (mRCC) remains a challenge due to the lack of biomarkers indicating the optimal drug for each patient. This study analyzed blood samples of patients with predominant clear cell mRCC who were treated with the mTOR inhibitor everolimus after failure of one prior tumor therapy. In an exploratory approach, predictive blood biomarkers were searched. We found lower levels of the protein thrombospondin-2 (TSP-2) at the start of the therapy and higher lactate dehydrogenase (LDH) levels in serum two weeks after therapy initiation to be associated with therapy response. Of note, these blood biomarkers had a higher predictive value than baseline patient parameters or risk classifications. Polymorphisms in the mTOR gene appeared to be associated with therapy response, but were not significant. To conclude, it seems feasible to identify patients showing longtime responses to everolimus and possible to increase tumor therapy response rates based on biomarkers for individual therapy selection.
Abstract: There is an unmet need for predictive biomarkers in metastatic renal cell carcinoma (mRCC) therapy. The phase IV MARC-2 trial searched for predictive blood biomarkers in patients with predominant clear cell mRCC who benefit from second-line treatment with everolimus. In an exploratory approach, potential biomarkers were assessed employing proteomics, ELISA, and polymorphism analyses. Lower levels of angiogenesis-related protein thrombospondin-2 (TSP-2) at baseline (≤665 parts per billion, ppb) identified therapy responders with longer median progression-free survival (PFS; ≤665 ppb at baseline: 6.9 months vs. 1.8, p = 0.005). Responders had higher lactate dehydrogenase (LDH) levels in serum two weeks after therapy initiation (>27.14 nmol/L), associated with a longer median PFS (3.8 months vs. 2.2, p = 0.013) and improved overall survival (OS; 31.0 months vs. 14.0 months, p < 0.001). Baseline TSP-2 levels had a stronger relation to PFS (HR 0.36, p = 0.008) than baseline patient parameters, including IMDC score. Increased serum LDH levels two weeks after therapy initiation were the best predictor for OS (HR 0.21, p < 0.001). mTOR polymorphisms appeared to be associated with therapy response but were not significant. Hence, we identified TSP-2 and LDH as promising predictive biomarkers for therapy response on everolimus after failure of one VEGF-targeted therapy in patients with clear cell mRCC.
An accurate measurement of the 140Ce(n,γ) energy-dependent cross-section was performed at the n_TOF facility at CERN. This cross-section is of great importance because it represents a bottleneck for the s-process nucleosynthesis and determines to a large extent the cerium abundance in stars. The measurement was motivated by the significant difference between the cerium abundance measured in globular clusters and the value predicted by theoretical stellar models. This discrepancy can be ascribed to an overestimation of the 140Ce capture cross-section due to a lack of accurate nuclear data. For this measurement, we used a sample of cerium oxide enriched in 140Ce to 99.4%. The experimental apparatus consisted of four deuterated benzene liquid scintillator detectors, which allowed us to overcome the difficulties present in the previous measurements, thanks to their very low neutron sensitivity. The accurate analysis of the p-wave resonances and the calculation of their average parameters are fundamental to improve the evaluation of the 140Ce Maxwellian-averaged cross-section.
Neutron capture on 241Am plays an important role in the nuclear energy production and also provides valuable information for the improvement of nuclear models and the statistical interpretation of the nuclear properties. A new experiment to measure the 241Am(n, γ) cross section in the thermal region and the first few resonances below 10 eV has been carried out at EAR2 of the n_TOF facility at CERN. Three neutron-insensitive C6D6 detectors have been used to measure the neutron-capture gamma cascade as a function of the neutron time of flight, and then deduce the neutron capture yield. Preliminary results will be presented and compared with previously obtained results at the same facility in EAR1. In EAR1 the gamma-ray background at thermal energies was about 90% of the signal while in EAR2 is up to a 25 factor much more favorable signal to noise ratio. We also extended the low energy limit down to subthermal energies. This measurement will allow a comparison with neutron capture measurements conducted at reactors and using a different experimental technique.
Background: While the incidence and aspects of pneumonia in ICU patients has been extensively discussed in the literature, studies on the occurrence of pneumonia in severely injured patients are rare. The aim of the present study is to elucidate factors associated with the occurrence of pneumonia in severely injured patients with thoracic trauma.
Setting: Level-I University Trauma Centres associated with the TraumaRegister DGU®.
Methods: A total of 1162 severely injured adult patients with thoracic trauma documented in the TraumaRegister DGU® (TR-DGU) were included in this study. Demographic data, injury severity, duration of mechanical ventilation (MV), duration of ICU stay, occurrence of pneumonia, bronchoalveolar lavage, aspiration, pathogen details, and incidences of mortality were evaluated. Statistical evaluation was performed using SPSS (Version 25.0, SPSS, Inc.) software.
Results: The overall incidence of pneumonia was 27.5%. Compared to patients without pneumonia, patients with pneumonia had sustained more severe injuries (mean ISS: 32.6 vs. 25.4), were older (mean age: 51.3 vs. 47.5) and spent longer periods under MV (mean: 368.9 h vs. 114.9 h). Age, sex (male), aspiration, and duration of MV were all independent predictors for pneumonia occurrence in a multivariate analysis. The cut-off point for duration of MV that best discriminated between patients who would and would not develop pneumonia during their hospital stay was 102 h. The extent of thoracic trauma (AISthorax), ISS, and presence of pulmonary comorbidities did not show significant associations to pneumonia incidence in our multivariate analysis. No significant difference in mortality between patients with and without pneumonia was observed.
Conclusions: Likelihood of pneumonia increases with age, aspiration, and duration of MV. These parameters were not found to be associated with differences in outcomes between patients with and without pneumonia. Future studies should focus on independent parameters to more clearly identify severely injured subgroups with a high risk of developing pneumonia.
Level of evidence: Level II - Retrospective medical record review.
Objectives In this early retrospective cohort study, a total of 26 patients with SARS-CoV-2 were treated with bamlanivimab or casirivimab/imdevimab, and the reduction of the viral load associated with the developed clinical symptoms was analyzed.
Methods: Patients in the intervention groups received bamlanivimab or casirivimab/imdevimab. Patients without treatment served as control. Outcomes were assessed by clinical symptoms and change in log viral load from baseline based on the cycle threshold over a period of 18 days.
Results: Median log viral load decline was higher in both intervention groups after 3 and 6 days compared to control. However, at later time points, the decline of the viral load was more distinct in the control group. Mild symptoms of COVID-19 were observed in 6.3% of the intervention groups and in no patient of the control. No patients treated with bamlanivimab, 18.8% treated with casirivimab/imdevimab, and 14.2% in the control group developed moderate symptoms. Severe symptoms were recorded only in the control group (14.2%), including one related death.
Conclusion: Treatment with monoclonal SARS-CoV-2 antibodies seems to accelerate decline of virus loads, especially in the first 6 days after administration, compared to control. This may be associated with a reduced likeliness of a severe course of COVID-19.
Although the 12C(n,p)12B and 12C(n,d)11B reactions are of interest in several fields of basic and applied Nuclear Physics the present knowledge of these two cross-sections is far from being accurate and reliable, with both evaluations and data showing sizable discrepancies. As part of the challenging n_TOF program on (n,cp) nuclear reactions study, the energy differential cross-sections of the 12C(n,p)12B and 12C(n,d)11 B reactions have been measured at CERN from the reaction thresholds up to 30 MeV neutron energy. Both measurements have been recently performed at the long flight-path (185 m) experimental area of the n_TOF facility at CERN using a pure (99.95%) rigid graphite target and two silicon telescopes. In this paper an overview of the experiment is presented together with a few preliminary results.
Background: Critical organ shortage results in the utilization of extended donor criteria (EDC) liver grafts. These marginal liver grafts are prone to increased ischemia reperfusion injury (IRI) which may contribute to deteriorated graft function and survival. Experimental data have shown that the calcineurin inhibitor tacrolimus exerts protective effects on hepatic IRI when applied intravenously or directly as a hepatic rinse. Therefore, the aim of the present study is to examine the effects of an ex vivo tacrolimus perfusion on IRI in transplantation of EDC liver grafts.
Methods/Design: The TOP-Study (tacrolimus organ perfusion) is a randomized multicenter trial comparing the ex vivo tacrolimus perfusion of marginal liver grafts with placebo. We hypothesize that a tacrolimus rinse reduces IRI, potentially improving organ survival following transplantation of EDC livers. The study includes livers with two or more EDC, according to Eurotransplant International Foundation’s definition of EDC livers. Prior to implantation, livers randomized to the treatment group are rinsed with tacrolimus at a concentration of 20 ng/ml in 1000 ml Custodiol solution and in the placebo group with Custodiol alone. The primary endpoint is the maximum serum alanine transamninase (ALT) level within the first 48 hours after surgery; however, the study design also includes a 1-year observation period following transplantation. The TOP-Study is an investigator-initiated trial sponsored by the University of Munich Hospital. Seven other German transplant centers are participating (Berlin, Frankfurt, Heidelberg, Mainz, Münster, Regensburg, Tübingen) and aim to include a total of 86 patients.
Discussion: Tacrolimus organ perfusion represents a promising strategy to reduce hepatic IRI following the transplantation of marginal liver grafts. This treatment may help to improve the function of EDC grafts and therefore safely expand the donor pool in light of critical organ shortage.
Trial register: EudraCT number: 2010-021333-31, ClinicalTrials.gov identifier: NCT01564095
Background In the pandemic, testing for SARS-CoV-2 by RT-PCR in one of the pillars on which countermeasures are based. Factors limiting the output of laboratories interfere with the effectiveness of public health measures. Conserving reagents by pooling samples in low-probability settings is proposed, but may cause dilution and loss of sensitivity.
Methods We tested an alternate approach (FACT) by simultaneously incubating multiple respiratory swabs in a single tube. This protocol was evaluated by serial incubation of a respiratory swab in up to 10 tubes. The analytics validity of this concept was demonstrated in a five-sample mini pool set-up. It was consequently applied in the testing of 50 symptomatic patients (five-sample pools) as well as 100 asymptomatic residents of a nursing home (ten-sample pools).
Results Serial incubation of a respiratory swab in up to 10 tubes did not lead to a significant decline in viral concentration. The novel FACT-protocol did not cause a false negative result in a five-sample mini-pool setup, with non-significantly differing Ct values between single sample and mini-pool NAT. In two routine applications, all mini pools containing positive patient samples were correctly identified.
Conclusions Our proposed FACT-protocol did not cause a significant loss in analytic or diagnostic sensitivity compared to single sample testing in multiple setups. It reduced the amount of reagents needed by up to 40%, and also reduced hands-on time. This method could enhance testing efficiency, especially in groups with a low pretest-probability, such as systemically relevant professional groups.
Background: In the pandemic, testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by real-time polymerase chain reaction is one of the pillars on which countermeasures are based. Factors limiting the output of laboratories interfere with the effectiveness of public health measures. Conserving reagents by pooling samples in low-probability settings is proposed but may cause dilution and loss of sensitivity. Blood transfusion services had experience in performance of high throughput nucleic acid testing (NAT) analysis and can support the national health system by screening of the inhabitants for SARS-COV-2.
Methods: We evaluated a new approach of a multiple-swab method by simultaneously incubating multiple respiratory swabs in a single tube. Analytical sensitivity was constant up to a total number of 50 swabs. It was consequently applied in the testing of 50 symptomatic patients (5-sample pools) as well as 100 asymptomatic residents of a nursing home (10-sample pools).
Results: The novel method did not cause false-negative results with nonsignificantly differing cycle threshold values between single-swab and multiple-swab NAT. In two routine applications, all minipools containing positive patient samples were correctly identified.
Conclusions: The new method enables countries to increase the total number of testing significantly. The multiple-swab method is able to screen system relevant groups of employees frequently. The example in Germany shows that blood transfusion services can support general health systems with their experience in NAT and their high-throughput instruments. Screening of a huge number of inhabitants is currently the only option to prevent a second infection wave and enable exit strategies in many countries.
High precision measurement of the radiative capture cross section of 238U at the n_TOF CERN facility
(2017)
The importance of improving the accuracy on the capture cross-section of 238U has been addressed by the Nuclear Energy Agency, since its uncertainty significantly affects the uncertainties of key design parameters for both fast and thermal nuclear reactors. Within the 7th framework programme ANDES of the European Commission three different measurements have been carried out with the aim of providing the 238U(n,γ) cross-section with an accuracy which varies from 1 to 5%, depending on the energy range. Hereby the final results of the measurement performed at the n_TOF CERN facility in a wide energy range from 1 eV to 700 keV will be presented.
Neutron-induced fission cross sections of 238U and 235U are used as standards in the fast neutron region up to 200 MeV. A high accuracy of the standards is relevant to experimentally determine other neutron reaction cross sections. Therefore, the detection effciency should be corrected by using the angular distribution of the fission fragments (FFAD), which are barely known above 20 MeV. In addition, the angular distribution of the fragments produced in the fission of highly excited and deformed nuclei is an important observable to investigate the nuclear fission process.
In order to measure the FFAD of neutron-induced reactions, a fission detection setup based on parallel-plate avalanche counters (PPACs) has been developed and successfully used at the CERN-n_TOF facility. In this work, we present the preliminary results on the analysis of new 235U(n,f) and 238U(n,f) data in the extended energy range up to 200 MeV compared to the existing experimental data.
The aim of this work is to provide a precise and accurate measurement of the 238U(n,γ) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behavior of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross section of 238U should be further reduced to 1–3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were proposed and carried out within the 7th Framework Project ANDES of the European Commission. The results of one of these 238U(n,γ) measurements performed at the n_TOF CERN facility are presented in this work. The γ-ray cascade following the radiative neutron capture has been detected exploiting a setup of two C6D6 liquid scintillators. Resonance parameters obtained from this work are on average in excellent agreement with the ones reported in evaluated libraries. In the unresolved resonance region, this work yields a cross section in agreement with evaluated libraries up to 80 keV, while for higher energies our results are significantly higher.
New results are presented of the 234U neutron-induced fission cross section, obtained with high accuracy in the resonance region by means of two methods using the 235U(n,f) as reference. The recent evaluation of the 235U(n,f) obtained with SAMMY by L. C. Leal et al. (these Proceedings), based on previous n_TOF data [1], has been used to calculate the 234U(n,f) cross section through the 234U/235U ratio, being here compared with the results obtained by using the n_TOF neutron flux.
The 236U isotope plays an important role in nuclear systems, both for future and currently operating ones. The actual knowledge of the capture reaction of this isotope is satisfactory in the thermal region, but it is considered insufficient for Fast Reactor and ADS applications. For this reason the 236U(n, γ) reaction cross-section has been measured for the first time in the whole energy region from thermal energy up to 1 MeV at the n_TOF facility with two different detection systems: an array of C6D6 detectors, employing the total energy deposited method, and a FX1 total absorption calorimeter (TAC), made of 40 BaF2 crystals. The two n_TOF data sets agree with each other within the statistical uncertainty in the Resolved Resonance Region up to 800 eV, while sizable differences (up to ≃ 20%) are found relative to the current evaluated data libraries. Moreover two new resonances have been found in the n_TOF data. In the Unresolved Resonance Region up to 200 keV, the n_TOF results show a reasonable agreement with previous measurements and evaluated data.
Background: The photon strength functions (PSFs) and nuclear level density (NLD) are key ingredients for calculation of the photon interaction with nuclei, in particular the reaction cross sections. These cross sections are important especially in nuclear astrophysics and in the development of advanced nuclear technologies.
Purpose: The role of the scissors mode in the M1 PSF of (well-deformed) actinides was investigated by several experimental techniques. The analyses of different experiments result in significant differences, especially on the strength of the mode. The shape of the low-energy tail of the giant electric dipole resonance is uncertain as well. In particular, some works proposed a presence of the E1 pygmy resonance just above 7 MeV. Because of these inconsistencies additional information on PSFs in this region is of great interest.
Methods: The γ-ray spectra from neutron-capture reactions on the 234U, 236 U, and 238 U nuclei have been measured with the total absorption calorimeter of the n_TOF facility at CERN. The background-corrected sum-energy and multi-step-cascade spectra were extracted for several isolated s-wave resonances up to about 140 eV.
Results: The experimental spectra were compared to statistical model predictions coming from a large selection of models of photon strength functions and nuclear level density. No combination of PSF and NLD models from literature is able to globally describe our spectra. After extensive search we were able to find model combinations with modified generalized Lorentzian (MGLO) E1 PSF, which match the experimental spectra as well as the total radiative widths.
Conclusions: The constant temperature energy dependence is favored for a NLD. The tail of giant electric dipole resonance is well described by the MGLO model of the E1 PSF with no hint of pygmy resonance. The M1 PSF must contain a very strong, relatively wide, and likely double-resonance scissors mode. The mode is responsible for about a half of the total radiative width of neutron resonances and significantly affects the radiative cross section.
Above 1 MeV of incident neutron energy the fission fragment angular distribution (FFAD) has generally a strong anisotropic behavior due to the combination of the incident orbital momentum and the intrinsic spin of the fissioning nucleus. This effect has to be taken into account for the efficiency estimation of devices used for fission cross section measurements. In addition it bears information on the spin deposition mechanism and on the structure of transitional states. We designed and constructed a detection device, based on Parallel Plate Avalanche Counters (PPAC), for measuring the fission fragment angular distributions of several isotopes, in particular 232Th. The measurement has been performed at n_TOF at CERN taking advantage of the very broad energy spectrum of the neutron beam. Fission events were recognized by back to back detection in coincidence in two position-sensitive detectors surrounding the targets. The detection efficiency, depending mostly on the stopping of fission fragments in backings and electrodes, has been computed with a Geant4 simulation and validated by the comparison to the measured case of 235U below 3 keV where the emission is isotropic. In the case of 232Th, the result is in good agreement with previous data below 10 MeV, with a good reproduction of the structures associated to vibrational states and the opening of second chance fission. In the 14 MeV region our data are much more accurate than previous ones which are broadly scattered.
The 14N(n,p)14C reaction is of interest in neutron capture therapy, where nitrogen-related dose is the main component due to low-energy neutrons, and in astrophysics, where 14N acts as a neutron poison in the s-process. Several discrepancies remain between the existing data obtained in partial energy ranges: thermal energy, keV region and resonance region. Purpose: Measuring the 14N(n,p)14C cross section from thermal to the resonance region in a single measurement for the first time, including characterization of the first resonances, and providing calculations of Maxwellian averaged cross sections (MACS). Method: Time-of-flight technique. Experimental Area 2 (EAR-2) of the neutron time-of-flight (n_TOF) facility at CERN. 10B(n,α)7Li and 235U(n,f) reactions as references. Two detection systems running simultaneously, one on-beam and another off-beam. Description of the resonances with the R-matrix code sammy. Results: The cross section has been measured from sub-thermal energy to 800 keV resolving the two first resonances (at 492.7 and 644 keV). A thermal cross-section (1.809±0.045 b) lower than the two most recent measurements by slightly more than one standard deviation, but in line with the ENDF/B-VIII.0 and JEFF-3.3 evaluations has been obtained. A 1/v energy dependence of the cross section has been confirmed up to tens of keV neutron energy. The low energy tail of the first resonance at 492.7 keV is lower than suggested by evaluated values, while the overall resonance strength agrees with evaluations. Conclusions: Our measurement has allowed to determine the 14N(n,p) cross-section over a wide energy range for the first time. We have obtained cross-sections with high accuracy (2.5 %) from sub-thermal energy to 800 keV and used these data to calculate the MACS for kT = 5 to kT = 100 keV.
The neutron sensitivity of the C6D6 detector setup used at n_TOF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a natC sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured natC yield has been discovered, which prevents the use of natC data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron background for two different samples are demonstrating the important role of accurate simulations of the neutron background in capture cross-section measurements.