Refine
Year of publication
Document Type
- Preprint (561)
- Article (458)
- Conference Proceeding (4)
- Review (3)
- Working Paper (1)
Has Fulltext
- yes (1027)
Is part of the Bibliography
- no (1027)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron scattering (experiments) (11)
- Hadron-Hadron Scattering (8)
- BESIII (5)
- Heavy-ion collision (5)
- Branching fraction (4)
- Collective Flow (4)
- Quark-Gluon Plasma (4)
- Quasi-free scattering (4)
- Artificial intelligence (3)
Institute
- Physik (938)
- Frankfurt Institute for Advanced Studies (FIAS) (752)
- Informatik (716)
- Medizin (52)
- ELEMENTS (16)
- Geowissenschaften (10)
- Informatik und Mathematik (6)
- Senckenbergische Naturforschende Gesellschaft (6)
- Rechtswissenschaft (5)
- Biodiversität und Klima Forschungszentrum (BiK-F) (4)
Large-scale genetic census of an elusive carnivore, the European wildcat (Felis s. silvestris)
(2016)
The European wildcat, Felis silvestris silvestris, serves as a prominent target species for the reconnection of central European forest habitats. Monitoring of this species, however, appears difficult due to its elusive behaviour and the ease of confusion with domestic cats. Recently, evidence for multiple wildcat occurrences outside its known distribution has accumulated in several areas across Central Europe, questioning the validity of available distribution data for this species. Our aim was to assess the fine-scale distribution and genetic status of the wildcat in its central European distribution range. We compiled and analysed genetic samples from roadkills and hundreds of recent hair-trapping surveys and applied phylogenetic and genetic clustering methods to discriminate wild and domestic cats and identify population subdivision. 2220 individuals were confirmed as either wildcat (n = 1792) or domestic cat (n = 342), and the remaining 86 (3.9 %) were identified as hybrids between the two. Remarkably, genetic distinction of domestic cats, wildcats and their hybrids was only possible when taking into account the presence of two highly distinct genetic lineages of wildcats, with a suture zone in central Germany. 44 % of the individual wildcats where sampled outside the previously published distribution. Our analyses confirm a relatively continuous spatial presence of wildcats across large parts of the study area in contrast to previous analyses indicating a highly fragmented distribution. Our results suggest that wildcat conservation and management should take advantage of the higher than previously assumed dispersal potential of wildcats, which may use wildlife corridors very efficiently.
Background: Bone age (BA) assessment performed by artificial intelligence (AI) is of growing interest due to improved accuracy, precision and time efficiency in daily routine. The aim of this study was to investigate the accuracy and efficiency of a novel AI software version for automated BA assessment in comparison to the Greulich-Pyle method.
Methods: Radiographs of 514 patients were analysed in this retrospective study. Total BA was assessed independently by three blinded radiologists applying the GP method and by the AI software. Overall and gender-specific BA assessment results, as well as reading times of both approaches, were compared, while the reference BA was defined by two blinded experienced paediatric radiologists in consensus by application of the Greulich-Pyle method.
Results: Mean absolute deviation (MAD) and root mean square deviation (RSMD) were significantly lower between AI-derived BA and reference BA (MAD 0.34 years, RSMD 0.38 years) than between reader-calculated BA and reference BA (MAD 0.79 years, RSMD 0.89 years; p < 0.001). The correlation between AI-derived BA and reference BA (r = 0.99) was significantly higher than between reader-calculated BA and reference BA (r = 0.90; p < 0.001). No statistical difference was found in reader agreement and correlation analyses regarding gender (p = 0.241). Mean reading times were reduced by 87% using the AI system.
Conclusions: A novel AI software enabled highly accurate automated BA assessment. It may improve efficiency in clinical routine by reducing reading times without compromising the accuracy compared with the Greulich-Pyle method.
Das sog. "Policeyrecht" gilt als Ausgangspunkt bei der Entstehungsgeschichte des modernen Verwaltungsrechts. Es wird daher von Michael Stolleis in der "Geschichte des öffentlichen Rechts" eingehend behandelt. Im Jahre 2000 ist außerdem die von ihm betreute Dissertation von Johann Christian Pauly zur "Entstehung des Polizeirechts als wissenschaftliche Disziplin" erschienen; sie gibt einen Überblick über die ersten Autoren und deren Publikationen, die unter dem im 18. Jahrhundert noch neuen Titel des "Policeyrechts" bzw. "Ius Politiae" veröffentlicht wurden. Erst seit der Mitte des 18. Jahrhunderts lässt sich in der Literatur die Unterscheidung zwischen einem genuin "policeywissenschaftlichen" und einem spezifisch "policeyrechtlichen" Ansatz beobachten; seitdem gibt es überhaupt erst das Wort "Policeyrecht". Damals erschienen die ersten Abhandlungen zu diesem Thema; soweit ersichtlich war die in Latein verfasste Arbeit von Johann Heumann die erste, die das "Ius Politiae" im Titel führte. Zu Beginn des 19. Jahrhunderts hat es sich dann zwar als Rechtsgebiet etabliert, wenn auch damals immer noch die Berechtigung einer Bezeichnung "Policeyrecht" nachdrücklich in Zweifel gezogen wurde. ...
Nina Kühnle wendet sich in ihrer Untersuchung in erster Linie sozialgeschichtlichen Fragestellungen zu. Im Eingangskapitel wirft sie die zentrale Ausgangsfrage ihrer Arbeit auf: Handelt es sich bei der sog. "Ehrbarkeit" in Württemberg tatsächlich um eine "ständegeschichtlich einzigartige Sondergruppe" unter den städtischen Oberschichten in Deutschland (8), die man in dieser Form tatsächlich nur in Württemberg antrifft? Und handelt es sich bei dieser "Ehrbarkeit" um einen halbwegs abgrenzbaren stadtbürgerlichen Stand, der sich von den Patriziaten anderer, zumal süddeutscher Städtelandschaften in signifikanter Weise unterscheidet? Eben dies war die mittlerweile allerdings überholte These des württembergischen Landeshistorikers Hansmartin Decker-Hauff: Ihm zufolge bildete die württembergische Ehrbarkeit einen ganz spezifischen Stand, der sich dadurch ausgezeichnet habe, dass bei ihm allein die ausgeübten Ämter und Funktionen die Standeszugehörigkeit begründet hätten. In der eingehenden Auseinandersetzung mit dieser These zeigt die Verf. sodann deren Schwachstellen auf (12–17), wobei sie an die Kritik von Gabriele Haug-Moritz anknüpft, die in ihrer Monographie über die württembergische Ehrbarkeit von Decker-Hauffs Konzept nicht mehr viel übrig gelassen hat: Die Ehrbarkeit bestand nicht – das dürfte mittlerweile feststehen – aus der Gruppe der Amtsinhaber; letztere kamen vielmehr zu Amt und Würden, weil sie aus der Ehrbarkeit stammten (17). "Ehrbarkeit" ergab sich demzufolge nicht aus einem Amt, sondern umgekehrt aus der Zugehörigkeit zu einer bestimmten Gesellschaftsschicht. Angesichts dessen spricht die Verf. in ihrer Arbeit auch nicht von "der Ehrbarkeit", sondern von "städtischen Führungsgruppen" oder der "Stadtelite" (26f.), hier im Anschluss an die neuere Sozialgeschichte, die bekanntlich seit geraumer Zeit eine besondere Vorliebe für das Wort "Elite" entwickelt hat. ...
Dual-energy CT (DECT) has emerged into clinical routine as an imaging technique with unique postprocessing utilities that improve the evaluation of different body areas. The virtual non-calcium (VNCa) reconstruction algorithm has shown beneficial effects on the depiction of bone marrow pathologies such as bone marrow edema. Its main advantage is the ability to substantially increase the image contrast of structures that are usually covered with calcium mineral, such as calcified vessels or bone marrow, and to depict a large number of traumatic, inflammatory, infiltrative, and degenerative disorders affecting either the spine or the appendicular skeleton. Therefore, VNCa imaging represents another step forward for DECT to image conditions and disorders that usually require the use of more expensive and time-consuming techniques such as magnetic resonance imaging, positron emission tomography/CT, or bone scintigraphy. The aim of this review article is to explain the technical background of VNCa imaging, showcase its applicability in the different body regions, and provide an updated outlook on the clinical impact of this technique, which goes beyond the sole improvement in image quality.
Background: Dual-source dual-energy computed tomography (DECT) offers the potential for opportunistic osteoporosis screening by enabling phantomless bone mineral density (BMD) quantification. This study sought to assess the accuracy and precision of volumetric BMD measurement using dual-source DECT in comparison to quantitative CT (QCT). Methods: A validated spine phantom consisting of three lumbar vertebra equivalents with 50 (L1), 100 (L2), and 200 mg/cm3 (L3) calcium hydroxyapatite (HA) concentrations was scanned employing third-generation dual-source DECT and QCT. While BMD assessment based on QCT required an additional standardised bone density calibration phantom, the DECT technique operated by using a dedicated postprocessing software based on material decomposition without requiring calibration phantoms. Accuracy and precision of both modalities were compared by calculating measurement errors. In addition, correlation and agreement analyses were performed using Pearson correlation, linear regression, and Bland-Altman plots. Results: DECT-derived BMD values differed significantly from those obtained by QCT (p < 0.001) and were found to be closer to true HA concentrations. Relative measurement errors were significantly smaller for DECT in comparison to QCT (L1, 0.94% versus 9.68%; L2, 0.28% versus 5.74%; L3, 0.24% versus 3.67%, respectively). DECT demonstrated better BMD measurement repeatability compared to QCT (coefficient of variance < 4.29% for DECT, < 6.74% for QCT). Both methods correlated well to each other (r = 0.9993; 95% confidence interval 0.9984–0.9997; p < 0.001) and revealed substantial agreement in Bland-Altman plots. Conclusions: Phantomless dual-source DECT-based BMD assessment of lumbar vertebra equivalents using material decomposition showed higher diagnostic accuracy compared to QCT.
Background: Since there is no standardized and effective treatment for advanced uveal melanoma (UM), the prognosis is dismal once metastases develop. Due to the availability of immune checkpoint blockade (ICB) in the real-world setting, the prognosis of metastatic UM has improved. However, it is unclear how the presence of hepatic and extrahepatic metastasis impacts the response and survival after ICB. Methods: A total of 178 patients with metastatic UM treated with ICB were included in this analysis. Patients were recruited from German skin cancer centers and the German national skin cancer registry (ADOReg). To investigate the impact of hepatic metastasis, two cohorts were compared: patients with liver metastasis only (cohort A, n = 55) versus those with both liver and extra-hepatic metastasis (cohort B, n = 123). Data were analyzed in both cohorts for response to treatment, progression-free survival (PFS), and overall survival (OS). The survival and progression probabilities were calculated with the Kaplan–Meier method. Log-rank tests, χ2 tests, and t-tests were performed to detect significant differences between both cohorts. Results: The median OS of the overall population was 16 months (95% CI 13.4–23.7) and the median PFS, 2.8 months (95% CI 2.5–3.0). The median OS was longer in cohort B than in cohort A (18.2 vs. 6.1 months; p = 0.071). The best objective response rate to dual ICB was 13.8% and to anti-PD-1 monotherapy 8.9% in the entire population. Patients with liver metastases only had a lower response to dual ICB, yet without significance (cohort A 8.7% vs. cohort B 16.7%; p = 0.45). Adverse events (AE) occurred in 41.6%. Severe AE were observed in 26.3% and evenly distributed between both cohorts. Conclusion: The survival of this large cohort of patients with advanced UM was more favorable than reported in previous benchmark studies. Patients with both hepatic and extrahepatic metastasis showed more favorable survival and higher response to dual ICB than those with hepatic metastasis only.
Objectives: To analyze the performance of radiological assessment categories and quantitative computational analysis of apparent diffusion coefficient (ADC) maps using variant machine learning algorithms to differentiate clinically significant versus insignificant prostate cancer (PCa). Methods: Retrospectively, 73 patients were included in the study. The patients (mean age, 66.3 ± 7.6 years) were examined with multiparametric MRI (mpMRI) prior to radical prostatectomy (n = 33) or targeted biopsy (n = 40). The index lesion was annotated in MRI ADC and the equivalent histologic slides according to the highest Gleason Grade Group (GrG). Volumes of interest (VOIs) were determined for each lesion and normal-appearing peripheral zone. VOIs were processed by radiomic analysis. For the classification of lesions according to their clinical significance (GrG ≥ 3), principal component (PC) analysis, univariate analysis (UA) with consecutive support vector machines, neural networks, and random forest analysis were performed. Results: PC analysis discriminated between benign and malignant prostate tissue. PC evaluation yielded no stratification of PCa lesions according to their clinical significance, but UA revealed differences in clinical assessment categories and radiomic features. We trained three classification models with fifteen feature subsets. We identified a subset of shape features which improved the diagnostic accuracy of the clinical assessment categories (maximum increase in diagnostic accuracy ΔAUC = + 0.05, p < 0.001) while also identifying combinations of features and models which reduced overall accuracy. Conclusions: The impact of radiomic features to differentiate PCa lesions according to their clinical significance remains controversial. It depends on feature selection and the employed machine learning algorithms. It can result in improvement or reduction of diagnostic performance.
Background: Surgical complications are associated with a significant burden to patients and hospitals and are increasingly discussed in recent literature. This cohort study reviewed surgery-related complications in a Level I trauma center. The effect of a complication avoidance care bundle on the rate of surgical complications was analyzed. Methods: All complications (surgical and nonsurgical) that occur in our trauma department are prospectively captured using a standardized documentation form and are discussed and analyzed in a weekly trauma Morbidity and Mortality (M&M) conference. Surgical complication rates are calculated using the annual surgical procedure numbers. Based on discussions in the M&M conference, a complication avoidance care bundle consisting of five measures was established: (1) Improving team situational awareness; (2) reducing operating room traffic by staff members and limiting door-opening events; (3) preoperative screening for infectious foci; (4) adapted preoperative antibiotic prophylaxis in anatomic regions with a high risk of infectious complications; and (5) use of iodine-impregnated adhesive drape. Results: The number of surgical procedures steadily increased over the study years, from 3587 in 2015 to 3962 in 2019 (an increase of 10.5%). Within this 5-year study period, the overall rate of surgical complications was 0.8%. Surgical site infections were the most frequently found complications (n = 40, 24.8% of all surgical complications), followed by screw malposition (n = 20, 12.4%), postoperative dislocations of arthroplasties (n = 18, 11.2%), and suboptimal fracture reduction (n = 18, 11.2%). Following implementation of the complication avoidance care bundle, the overall rate of surgical complications significantly decreased, from 1.14% in the year 2016 to 0.56% in the study year 2019, which represents a reduction of 51% within a 3-year time period. Conclusions: A multimodal strategy targeted at reducing the surgical complication rate can be successfully established based on a transparent discussion of adverse surgical outcomes. The combination of the different preventive measures was associated with reducing the overall complication rate by half within a 3-year time period.
Primary cilia are microtubule-based organelles that detect mechanical and chemical stimuli. Although cilia house a number of oncogenic molecules (including Smoothened, KRAS, EGFR, and PDGFR), their precise role in cancer remains unclear. We have interrogated the role of cilia in acquired and de novo resistance to a variety of kinase inhibitors, and found that, in several examples, resistant cells are distinctly characterized by an increase in the number and/or length of cilia with altered structural features. Changes in ciliation seem to be linked to differences in the molecular composition of cilia and result in enhanced Hedgehog pathway activation. Notably, manipulating cilia length via Kif7 knockdown is sufficient to confer drug resistance in drug-sensitive cells. Conversely, targeting of cilia length or integrity through genetic and pharmacological approaches overcomes kinase inhibitor resistance. Our work establishes a role for ciliogenesis and cilia length in promoting cancer drug resistance and has significant translational implications.
Non-forest ecosystems, dominated by shrubs, grasses and herbaceous plants, provide ecosystem services including carbon sequestration and forage for grazing, and are highly sensitive to climatic changes. Yet these ecosystems are poorly represented in remotely sensed biomass products and are undersampled by in situ monitoring. Current global change threats emphasize the need for new tools to capture biomass change in non-forest ecosystems at appropriate scales. Here we developed and deployed a new protocol for photogrammetric height using unoccupied aerial vehicle (UAV) images to test its capability for delivering standardized measurements of biomass across a globally distributed field experiment. We assessed whether canopy height inferred from UAV photogrammetry allows the prediction of aboveground biomass (AGB) across low-stature plant species by conducting 38 photogrammetric surveys over 741 harvested plots to sample 50 species. We found mean canopy height was strongly predictive of AGB across species, with a median adjusted R2 of 0.87 (ranging from 0.46 to 0.99) and median prediction error from leave-one-out cross-validation of 3.9%. Biomass per-unit-of-height was similar within but different among, plant functional types. We found that photogrammetric reconstructions of canopy height were sensitive to wind speed but not sun elevation during surveys. We demonstrated that our photogrammetric approach produced generalizable measurements across growth forms and environmental settings and yielded accuracies as good as those obtained from in situ approaches. We demonstrate that using a standardized approach for UAV photogrammetry can deliver accurate AGB estimates across a wide range of dynamic and heterogeneous ecosystems. Many academic and land management institutions have the technical capacity to deploy these approaches over extents of 1–10 ha−1. Photogrammetric approaches could provide much-needed information required to calibrate and validate the vegetation models and satellite-derived biomass products that are essential to understand vulnerable and understudied non-forested ecosystems around the globe.
Many QCD based and phenomenological models predict changes of hadron properties in a strongly interacting environment. The results of these models differ significantly and the experimental determination of hadron properties in nuclear matter is essential. In this paper we present a review of selected physics results obtained at GSI Helmholtzzentrum für Schwerionenforschung GmbH by HADES (High-Acceptance Di-Electron Spectrometer). The e+e− pair emission measured for proton and heavy-ion induced collisions is reported together with results on strangeness production. The future HADES activities at the planned FAIR facility are also discussed.
The knowledge of baryonic resonance properties and production cross sections plays an important role for the extraction and understanding of medium modifications of mesons in hot and/or dense nuclear matter. We present and discuss systematics on dielectron and strangeness production obtained with HADES on p+p, p+A and A+A collisions in the few GeV energy regime with respect to these resonances.
The High Acceptance DiElectron Spectrometer HADES [1] is installed at the Helmholtzzentrum für Schwerionenforschung (GSI) accelerator facility in Darmstadt. It investigates dielectron emission and strangeness production in the 1-3 AGeV regime. A recent experiment series focusses on medium-modifications of light vector mesons in cold nuclear matter. In two runs, p+p and p+Nb reactions were investigated at 3.5 GeV beam energy; about 9·109 events have been registered. In contrast to other experiments the high acceptance of the HADES allows for a detailed analysis of electron pairs with low momenta relative to nuclear matter, where modifications of the spectral functions of vector mesons are predicted to be most prominent. Comparing these low momentum electron pairs to the reference measurement in the elementary p+p reaction, we find in fact a strong modification of the spectral distribution in the whole vector meson region.
Activated SUMOylation restricts MHC class I antigen presentation to confer immune evasion in cancer
(2022)
Activated SUMOylation is a hallmark of cancer. Starting from a targeted screening for SUMO-regulated immune evasion mechanisms, we identified an evolutionarily conserved function of activated SUMOylation, which attenuated the immunogenicity of tumor cells. Activated SUMOylation allowed cancer cells to evade CD8+ T cell–mediated immunosurveillance by suppressing the MHC class I (MHC-I) antigen-processing and presentation machinery (APM). Loss of the MHC-I APM is a frequent cause of resistance to cancer immunotherapies, and the pharmacological inhibition of SUMOylation (SUMOi) resulted in reduced activity of the transcriptional repressor scaffold attachment factor B (SAFB) and induction of the MHC-I APM. Consequently, SUMOi enhanced the presentation of antigens and the susceptibility of tumor cells to CD8+ T cell–mediated killing. Importantly, SUMOi also triggered the activation of CD8+ T cells and thereby drove a feed-forward loop amplifying the specific antitumor immune response. In summary, we showed that activated SUMOylation allowed tumor cells to evade antitumor immunosurveillance, and we have expanded the understanding of SUMOi as a rational therapeutic strategy for enhancing the efficacy of cancer immunotherapies.
Objectives: To compare radiation dose and image quality of single-energy (SECT) and dual-energy (DECT) head and neck CT examinations performed with second- and third-generation dual-source CT (DSCT) in matched patient cohorts. Methods: 200 patients (mean age 55.1 ± 16.9 years) who underwent venous phase head and neck CT with a vendor-preset protocol were retrospectively divided into four equal groups (n = 50) matched by gender and BMI: second (Group A, SECT, 100-kV; Group B, DECT, 80/Sn140-kV), and third-generation DSCT (Group C, SECT, 100-kV; Group D, DECT, 90/Sn150-kV). Assess- ment of radiation dose was performed for an average scan length of 27 cm. Contrast-to-noise ratio measure- ments and dose-independent figure-of-merit calcu- lations of the submandibular gland, thyroid, internal jugular vein, and common carotid artery were analyzed quantitatively. Qualitative image parameters were evalu- ated regarding overall image quality, artifacts and reader confidence using 5-point Likert scales. Results: Effective radiation dose (ED) was not signifi- cantly different between SECT and DECT acquisition for each scanner generation (p = 0.10). Significantly lower effective radiation dose (p < 0.01) values were observed for third-generation DSCT groups C (1.1 ± 0.2 mSv) and D (1.0 ± 0.3 mSv) compared to second-generation DSCT groups A (1.8 ± 0.1 mSv) and B (1.6 ± 0.2 mSv). Figure-of- merit/contrast-to-noise ratio analysis revealed superior results for third-generation DECT Group D compared to all other groups. Qualitative image parameters showed non-significant differences between all groups (p > 0.06). Conclusion: Contrast-enhanced head and neck DECT can be performed with second- and third-generation DSCT systems without radiation penalty or impaired image quality compared with SECT, while third-generation DSCT is the most dose efficient acquisition method. Advances in knowledge: Differences in radiation dose between SECT and DECT of the dose-vulnerable head and neck region using DSCT systems have not been evaluated so far. Therefore, this study directly compares radiation dose and image quality of standard SECT and DECT protocols of second- and third-generation DSCT platforms.
Objectives: To determine the diagnostic accuracy of dual-energy CT (DECT) virtual noncalcium (VNCa) reconstructions for assessing thoracic disk herniation compared to standard grayscale CT. Methods: In this retrospective study, 87 patients (1131 intervertebral disks; mean age, 66 years; 47 women) who underwent third-generation dual-source DECT and 3.0-T MRI within 3 weeks between November 2016 and April 2020 were included. Five blinded radiologists analyzed standard DECT and color-coded VNCa images after a time interval of 8 weeks for the presence and degree of thoracic disk herniation and spinal nerve root impingement. Consensus reading of independently evaluated MRI series served as the reference standard, assessed by two separate experienced readers. Additionally, image ratings were carried out by using 5-point Likert scales. Results: MRI revealed a total of 133 herniated thoracic disks. Color-coded VNCa images yielded higher overall sensitivity (624/665 [94%; 95% CI, 0.89–0.96] vs 485/665 [73%; 95% CI, 0.67–0.80]), specificity (4775/4990 [96%; 95% CI, 0.90–0.98] vs 4066/4990 [82%; 95% CI, 0.79–0.84]), and accuracy (5399/5655 [96%; 95% CI, 0.93–0.98] vs 4551/5655 [81%; 95% CI, 0.74–0.86]) for the assessment of thoracic disk herniation compared to standard CT (all p < .001). Interrater agreement was excellent for VNCa and fair for standard CT (ϰ = 0.82 vs 0.37; p < .001). In addition, VNCa imaging achieved higher scores regarding diagnostic confidence, image quality, and noise compared to standard CT (all p < .001). Conclusions: Color-coded VNCa imaging yielded substantially higher diagnostic accuracy and confidence for assessing thoracic disk herniation compared to standard CT.
In the past two decades, pions created in the high density regions of heavy ion collisions have been predicted to be sensitive at high densities to the symmetry energy term in the nuclear equation of state, a property that is key to our understanding of neutron stars. In a new experiment designed to study the symmetry energy, the multiplicities of negatively and positively charged pions have been measured with high accuracy for central 132Sn+124Sn, 112Sn+124Sn, and 108Sn+112Sn collisions at E/A = 270 MeV with the SπRIT Time Projection Chamber. While individual pion multiplicities are measured to 4% accuracy, those of the charged pion multiplicity ratios are measured to 2% accuracy. We compare these data to predictions from seven major transport models. The calculations reproduce qualitatively the dependence of the multiplicities and their ratios on the total neutron and proton number in the colliding systems. However, the predictions of the transport models from different codes differ too much to allow extraction of reliable constraints on the symmetry energy from the data. This finding may explain previous contradictory conclusions on symmetry energy constraints obtained from pion data in Au+Au system. These new results call for still better understanding of the differences among transport codes, and new observables that are more sensitive to the density dependence of the symmetry energy.
Purpose: To investigate the diagnostic performance of noise-optimized virtual monoenergetic images (VMI+) in dual-energy CT (DECT) of portal vein thrombosis (PVT) compared to standard reconstructions. Method: This retrospective, single-center study included 107 patients (68 men; mean age, 60.1 ± 10.7 years) with malignant or cirrhotic liver disease and suspected PVT who had undergone contrast-enhanced portal-phase DECT of the abdomen. Linearly blended (M_0.6) and virtual monoenergetic images were calculated using both standard VMI and noise-optimized VMI+ algorithms in 20 keV increments from 40 to 100 keV. Quantitative measurements were performed in the portal vein for objective contrast-to-noise ratio (CNR) calculation. The image series showing the greatest CNR were further assessed for subjective image quality and diagnostic accuracy of PVT detection by two blinded radiologists. Results: PVT was present in 38 subjects. VMI+ reconstructions at 40 keV revealed the best objective image quality (CNR, 9.6 ± 4.3) compared to all other image reconstructions (p < 0.01). In the standard VMI series, CNR peaked at 60 keV (CNR, 4.7 ± 2.1). Qualitative image parameters showed the highest image quality rating scores for the 60 keV VMI+ series (median, 4) (p ≤ 0.03). The greatest diagnostic accuracy for the diagnosis of PVT was found for the 40 keV VMI+ series (sensitivity, 96%; specificity, 96%) compared to M_0.6 images (sensitivity, 87%; specificity, 92%), 60 keV VMI (sensitivity, 87%; specificity, 97%), and 60 keV VMI+ reconstructions (sensitivity, 92%; specificity, 97%) (p ≤ 0.01). Conclusions: Low-keV VMI+ reconstructions resulted in significantly improved diagnostic performance for the detection of PVT compared to other DECT reconstruction algorithms.
Background: Autism spectrum disorder (“autism”) is a highly heterogeneous neurodevelopmental condition with few effective treatments for core and associated features. To make progress we need to both identify and validate neural markers that help to parse heterogeneity to tailor therapies to specific neurobiological profiles. Atypical hemispheric lateralization is a stable feature across studies in autism, but its potential as a neural stratification marker has not been widely examined. Methods: In order to dissect heterogeneity in lateralization in autism, we used the large EU-AIMS (European Autism Interventions—A Multicentre Study for Developing New Medications) Longitudinal European Autism Project dataset comprising 352 individuals with autism and 233 neurotypical control subjects as well as a replication dataset from ABIDE (Autism Brain Imaging Data Exchange) (513 individuals with autism, 691 neurotypical subjects) using a promising approach that moves beyond mean group comparisons. We derived gray matter voxelwise laterality values for each subject and modeled individual deviations from the normative pattern of brain laterality across age using normative modeling. Results: Individuals with autism had highly individualized patterns of both extreme right- and leftward deviations, particularly in language, motor, and visuospatial regions, associated with symptom severity. Language delay explained most variance in extreme rightward patterns, whereas core autism symptom severity explained most variance in extreme leftward patterns. Follow-up analyses showed that a stepwise pattern emerged, with individuals with autism with language delay showing more pronounced rightward deviations than individuals with autism without language delay. Conclusions: Our analyses corroborate the need for novel (dimensional) approaches to delineate the heterogeneous neuroanatomy in autism and indicate that atypical lateralization may constitute a neurophenotype for clinically meaningful stratification in autism.