Refine
Document Type
- Article (2)
Language
- English (2)
Has Fulltext
- yes (2) (remove)
Is part of the Bibliography
- no (2)
Keywords
- Cornea (1)
- Eyes (1)
- Mucopolysaccharidoses (1)
- Opacity (1)
- Ophthalmology (1)
- Optical lenses (1)
- Visual acuity (1)
- Visual impairments (1)
- amblyopia (1)
- pediatric eye screening (1)
Institute
- Medizin (2) (remove)
Corneal topometric, aberrometric and biomechanical parameters in mucopolysaccharidosis patients
(2019)
Aims: To report corneal topometric and aberrometric values in mucopolysaccharidosis (MPS) and to investigate their correlation with biomechanical corneal parameters.
Methods: One randomly chosen eye of 20 MPS patients with no to moderate corneal clouding and one eye of 23 healthy controls with comparable age were prospectively included into this study. Corneal surface regularity was assessed by index of surface variance (ISV), -vertical asymmetry (IVA), -height asymmetry (IHA), -height decentration (IHD); keratoconus index (KI), central keratoconus index (CKI) and Zernike indices of anterior and posterior corneal surface using Scheimpflug imaging (Pentacam). Corneal resistance factor (CRF) and corneal hysteresis (CH) were assessed by Ocular Response Analyzer. Statistical analyses were performed using Mann-Whitney-Test and Spearman Correlation Coefficients.
Results: IVA, ISV, IHD, IHA, but not KI and CKI were significantly higher in MPS patients compared to age matched healthy controls. Spherical aberration and asphericity coefficients either at the anterior or at the posterior corneal surface differed significantly between both groups. The grade of the MPS-associated corneal opacity correlated significantly with ISV (rho = 0.52), IVA (rho = 0.54), IHA (rho = 0.57) and IHD (rho = 0.48). Density of the MPS-affected corneas correlated significantly with ISV (rho = 0.52), IVA (rho = 0.72), IHA (rho = 0.57), IHD (rho = 0.69), 3rd order horizontal trefoil aberration at the posterior (rho = 0.62) and anterior surface (rho = 0.48) as well as with CH (rho = 0.55) and CRF (rho = 0.57). Spherical aberration at the back surface correlated with CRF and CH in MPS and in healthy controls.
Conclusions: This is the first study analyzing shape of the corneal surface in MPS patients. Topometric indices of corneal asymmetry are significantly increased and correlate with MPS-related corneal opacity and density. Spherical aberration and asphericity coefficient at the front and at the back corneal surface differ significantly between MPS and healthy controls.
Background: The newly introduced German pediatric screening examination at the end of the third year of life (U7a) incorporates visual function testing in particular; there is no ophthalmic screening during childhood in Germany. The purpose of this study is to investigate the relationship between participation in U7a and visual function at the preschool health examination (PHE) in the sixth year of life. Methods: This study evaluated PHE data from school enrollment years 2009/2010 to 2014/2015 of Rhineland-Palatinate, Germany. Visual acuity (VA) at PHE was assessed with Rodenstock visual acuity test device (tumbling E) wearing glasses if present. The relationship between participation in U7a and VA <0.7 at PHE was calculated for reduced monocular and binocular VA using multiple logistic regression adjusted for potential confounders. Results: Data from 189,704 children (91,041 girls) in 35 out of 36 districts were included. The first children to participate in U7a were enrolled in 2011/2012 school year. In total, 90,339 children (47.6%) had U7a before PHE, while 99,365 (52.4%) had not. VA <0.7 in at least one eye was measured at PHE in 8429 (4.4%) children, and in both eyes in 4345 (2.3%) children. Participation in U7a was not associated with VA <0.7 at PHE (odds ratio 0.99; 95% confidence interval: 0.94–1.04). Conclusions: The proportion of children with VA <0.7 at PHE was high. No beneficial effect of newly introduced German U7a pediatric screening examination was found for reduced VA at PHE.