Refine
Year of publication
Document Type
- Preprint (775)
- Article (501)
- Conference Proceeding (3)
- Review (3)
- Part of a Book (2)
- Report (1)
- Working Paper (1)
Has Fulltext
- yes (1286) (remove)
Is part of the Bibliography
- no (1286)
Keywords
- Heavy Ion Experiments (21)
- Hadron-Hadron Scattering (14)
- Hadron-Hadron scattering (experiments) (12)
- LHC (10)
- Heavy-ion collision (6)
- Jets (6)
- ALICE experiment (4)
- Collective Flow (4)
- Heavy Ions (4)
- Heavy Quark Production (4)
Institute
- Physik (1169)
- Frankfurt Institute for Advanced Studies (FIAS) (1101)
- Informatik (1004)
- Medizin (33)
- Biochemie, Chemie und Pharmazie (5)
- Informatik und Mathematik (4)
- Neuere Philologien (3)
- Biochemie und Chemie (2)
- Hochschulrechenzentrum (2)
- MPI für Biophysik (2)
Zentrale Voraussetzung einer differenzierten Bewertung der germanistischen Online-Lehre wäre, zunächst die Rolle der Germanistik in der digitalen Gesellschaft sowie den Wert digitaler Bildung zu bestimmen. Dazu wiederum wäre es wichtig, das Wissen, die Methoden, die Begriffe und Fragestellungen der Germanistik in ein Verhältnis zu den Potenzialen und Problemen der digitalen Gesellschaft zu setzen. Zwar adressieren Arbeitsgruppen in den Fachverbänden diese Aufgabe, die germanistischen Teildisziplinen gehen damit aber unterschiedlich um. Als Teildisziplin hat somit auch eine medienkulturwissenschaftlich ausgerichtete (Gegenwarts-)Literaturwissenschaft die Pflicht, nach den Folgen des Medienwandels und der vernetzten Kommunikation im World Wide Web für die Literatur, ihren Betrieb und für die literaturwissenschaftliche Forschung und Lehre zu fragen. Auf einer Konferenz zum Thema "Während und nach Corona: Digitale Lehre in der Germanistik" erscheinen vor diesem Hintergrund zwei Fragen besonders relevant: 1. Welche digitalen Standards und Erkenntnisse müsste die Germanistik etablieren, um gelungene Lehre in der digitalen Kultur überhaupt bewerten zu können? 2. Wie wäre ein Teilbereich der germanistischen Literaturwissenschaft als Netzliteraturwissenschaft zu konzipieren, der das notwendige Wissen über die vernetzte Kommunikation in der digitalen Gesellschaft bereithält und zur Etablierung von Standards des digitalen germanistischen Lernens beitragen könnte?
Rezensionen [2020]
(2020)
Verzeichnis
Einzelrezensionen
148 Bäni Rigler, Petra: Bilderbuch – Lesebuch – Künstlerbuch. Elsa Beskows Ästhetik des Materiellen (Heinz-Jürgen Kliewer)
149 Barilaro, Christina/Oetken, Mareile(Hg.): Erzähl mir vom Tier. Tiere in der Kinderliteratur und in der Natur (Kurt Franz)
151 Bieker, Nadine: Erzählanfänge und Erzählschlüsse im Adoleszenzroman (Astrid Henning-Mohr)
153 Blumesberger, Susanne/Seibert, Ernst (Hg.): Kinderliteratur in Wien um 1800 (Michael Stierstorfer)
154 Brons, Patricia/Nickel, Artur /Nicolai, Matthias (Hg.): Kästneriaden zum 120. Geburtstag (Sabine Planka)
156 Dallmann, Christine/Hartung, Anja/Aigner, Alfons /Buchele, Kai-Thorsten (Hg.): Comics. Interdisziplinäre Perspektiven aus Theorie und Praxis auf ein Stiefkind der Medienpädagogik (Carolin Führer)
157 Darr, Yael: The Nation and the Child. Nation Building in Hebrew Children’s Literature, 1930–1970 (Susanne Blumesberger)
159 Dingelmaier, Theresia: Das Märchen vom Märchen. Eine kultur- und literaturwissenschaftliche Untersuchung des deutschsprachigen jüdischen Volks- und Kindermärchens (Kurt Franz)
161 Field, Hannah: Playing with the Book. Victorian Movable Picture Books and the Child Reader (Petra Bäni Rigler)
163 Gittinger, Kerstin/ Loidl, Sonja (Hg.): Unter Wölfen. Käthe Recheis – Literatur und Politik (Lena Hoffmann)
164 Giuriato, Davide/Hubmann, Philipp/Schildmann, Mareike (Hg.): Kindheit und Literatur. Konzepte – Poetik – Wissen (Ernst Seibert)
166 Glasenapp, Gabriele von/Pecher, Claudia Maria/Anker, Martin (Hg.): Martin Luther und die Reformation in der Kinder- und Jugendliteratur. Beiträge zur literarhistorischen und literarästhetischen Praxis (Roland Issler)
169 Gruner, Elizabeth Rose: Constructing the Adolescent Reader in Contemporary Young Adult Fiction (Thomas Kullmann)
171 Harde, Roxanne/Kokkola, Lydia (Hg.): The Embodied Child. Readings in Children’s Literature and Culture (Thomas Kullmann)
172 Holzen, Aleta-Amirée von: Maskierte Helden. Zur Doppelidentität in Pulp-Novels und Superheldencomics (Maike Paiska)
174 Hubli, Kathrin: Kunstprojekt (Mumin-)Buch. Tove Janssons prozessuale Ästhetik und materielle Transmission (Ben Dammers)
175 Jantzen, Christoph/ Josting, Petra/Ritter, Michael (Hg.): Ästhetik – Leserbezug – Wirkung. Ansprüche an Kinder- und Jugendliteratur im Wandel der Zeit (Nadine Bieker)
177 Jung, Britta C.: Komplexe Lebenswelten – multidirektionale Erinnerungsdiskurse. Jugendliteratur zum Nationalsozialismus, Zweiten Weltkrieg und Holocaust im Spiegel des postmemorialen Wandels (Susanne Blumesberger)
179 Meyer, Christina: Producing Mass Entertainment. The Serial Life of the Yellow Kid (Aleta-Amirée von Holzen)
181 Rox-Helmer, Monika: Der historische Jugendroman als geschichtskulturelle Gattung. Fiktionalisierung von Geschichte und ihr didaktisches Potential (Annette Kliewer)
182 Seidel, Nadine Maria: Adoleszenz, Geschlecht, Identität. Queere Konstruktionen in Romanen nach der Jahrtausendwende (Annette Kliewer)
184 Sonyem, Alain Belmond: Kinder- und Jugendliteratur als Gegendiskurs? Zu Afrikavorstellungen in neueren deutschen und deutschafrikanischen Kinder- und Jugendbüchern (Astrid Henning-Mohr)
186 Sprenger, Karoline: Bertolt Brechts Kinderlyrik. Hintergründe, Analysen und fachdidaktische Perspektiven (Kurt Franz)
188 Uhlig, Bettina/ Lieber, Gabriele/Pieper, Irene (Hg.): Erzählen zwischen Bild und Text (Heinz-Jürgen Kliewer) 190 Van Nahl, Ruth: Jugendkrimis im 21. Jahrhundert. Eine Typologie (Sabine Fuchs)
192 Wietersheim, Annegret von: »Später einmal werde ich es dir erzählen«. Leerstellen in der Kinder- und Jugendliteratur der 1950er Jahre (Susanne Blumesberger)
The transverse mass mt distributions for deuterons and protons are measured in Pb+Pb reactions near midrapidity and in the range 0<mt–m<1.0 (1.5) GeV/c2 for minimum bias collisions at 158A GeV and for central collisions at 40 and 80 A GeV beam energies. The rapidity density dn/dy, inverse slope parameter T and mean transverse mass <mt> derived from mt distributions as well as the coalescence parameter B2 are studied as a function of the incident energy and the collision centrality. The deuteron mt spectra are significantly harder than those of protons, especially in central collisions. The coalescence factor B2 shows three systematic trends. First, it decreases strongly with increasing centrality reflecting an enlargement of the deuteron coalescence volume in central Pb+Pb collisions. Second, it increases with mt. Finally, B2 shows an increase with decreasing incident beam energy even within the SPS energy range. The results are discussed and compared to the predictions of models that include the collective expansion of the source created in Pb+Pb collisions.
Background: Bipolar disorder is associated with circadian disruption and a high risk of suicidal behavior. In a previous exploratory study of patients with bipolar I disorder, we found that a history of suicide attempts was associated with differences between winter and summer levels of solar insolation. The purpose of this study was to confirm this finding using international data from 42% more collection sites and 25% more countries. Methods: Data analyzed were from 71 prior and new collection sites in 40 countries at a wide range of latitudes. The analysis included 4876 patients with bipolar I disorder, 45% more data than previously analyzed. Of the patients, 1496 (30.7%) had a history of suicide attempt. Solar insolation data, the amount of the sun’s electromagnetic energy striking the surface of the earth, was obtained for each onset location (479 locations in 64 countries). Results: This analysis confirmed the results of the exploratory study with the same best model and slightly better statistical significance. There was a significant inverse association between a history of suicide attempts and the ratio of mean winter insolation to mean summer insolation (mean winter insolation/mean summer insolation). This ratio is largest near the equator which has little change in solar insolation over the year, and smallest near the poles where the winter insolation is very small compared to the summer insolation. Other variables in the model associated with an increased risk of suicide attempts were a history of alcohol or substance abuse, female gender, and younger birth cohort. The winter/summer insolation ratio was also replaced with the ratio of minimum mean monthly insolation to the maximum mean monthly insolation to accommodate insolation patterns in the tropics, and nearly identical results were found. All estimated coefficients were significant at p < 0.01. Conclusion: A large change in solar insolation, both between winter and summer and between the minimum and maximum monthly values, may increase the risk of suicide attempts in bipolar I disorder. With frequent circadian rhythm dysfunction and suicidal behavior in bipolar disorder, greater understanding of the optimal roles of daylight and electric lighting in circadian entrainment is needed.
Depletion of the enzyme cofactor, tetrahydrobiopterin (BH4), in T-cells was shown to prevent their proliferation upon receptor stimulation in models of allergic inflammation in mice, suggesting that BH4 drives autoimmunity. Hence, the clinically available BH4 drug (sapropterin) might increase the risk of autoimmune diseases. The present study assessed the implications for multiple sclerosis (MS) as an exemplary CNS autoimmune disease. Plasma levels of biopterin were persistently low in MS patients and tended to be lower with high Expanded Disability Status Scale (EDSS). Instead, the bypass product, neopterin, was increased. The deregulation suggested that BH4 replenishment might further drive the immune response or beneficially restore the BH4 balances. To answer this question, mice were treated with sapropterin in immunization-evoked autoimmune encephalomyelitis (EAE), a model of multiple sclerosis. Sapropterin-treated mice had higher EAE disease scores associated with higher numbers of T-cells infiltrating the spinal cord, but normal T-cell subpopulations in spleen and blood. Mechanistically, sapropterin treatment was associated with increased plasma levels of long-chain ceramides and low levels of the poly-unsaturated fatty acid, linolenic acid (FA18:3). These lipid changes are known to contribute to disruptions of the blood–brain barrier in EAE mice. Indeed, RNA data analyses revealed upregulations of genes involved in ceramide synthesis in brain endothelial cells of EAE mice (LASS6/CERS6, LASS3/CERS3, UGCG, ELOVL6, and ELOVL4). The results support the view that BH4 fortifies autoimmune CNS disease, mechanistically involving lipid deregulations that are known to contribute to the EAE pathology.
Rezensionen [2019]
(2019)
Verzeichnis
Einzelrezensionen
163 Babenhauserheide, Melanie: Harry Potter und die Widersprüche der Kulturindustrie. Eine ideologiekritische Analyse (DAVID N. SCHMIDT)
165 Ballis, Anja/Pecher, Claudia Maria/ Schuler, Rebecca (Hrsg.): Mehrsprachige Kinder- und Jugendliteratur. Überlegungen zur Systematik, Didaktik und Verbreitung (SVETLANA VISHEK)
167 Bannasch, Bettina/Matthes, Eva (Hrsg.): Kinder- und Jugendliteratur. Historische, erzähl- und medientheoretische, pädagogische und therapeutische Perspektiven (susanne blumesberger)
169 Batzke, Ina/ Erbacher, Eric C. /Heß, Linda M. / Lenhardt, Corinna (Hrsg.): Exploring the Fantastic. Genre, Ideology, and Popular Culture (THOMAS BITTERLICH)
170 Bertling, Maria: All-Age-Literatur. Die Entdeckung einer neuen Zielgruppe und ihrer Rezeptionsmodalitäten (NICOLA KÖNIG)
172 Blümer, Agnes: Mehrdeutigkeit übersetzen. Englische und französische Kinderliteraturklassiker der Nachkriegszeit in deutscher Übertrag (MARTINA SEIFERT)
174 Blumesberger, Susanne/Thunecke, Jörg (Hrsg.): Deutschsprachige Kinder- und Jugendliteratur während der Zwischenkriegszeit und im Exil. Schwerpunkt Österreich (KURT FRANZ)
176 Busch, Nathanael /Velten, Hans Rudolf (Hrsg.): Die Literatur des Mittelalters im Fantasyroman (SONJA LOIDL)
178 Cave, Roderick/Ayad, Sara (Hrsg.): Die Geschichte des Kinderbuches in 100 Büchern (ERNST SEIBERT)
180 Dettmar, Ute/Pecher, Claudia Maria/Schlesinger, Ron (Hrsg.): Märchen im Medienwechsel. Zur Geschichte und Gegenwart des Märchenfilms (MICHAEL STIERSTORFER)
182 Dommermuth, Clarissa: Wir sind dagegen – denn ihr seid dafür. Zur Tradition literarischer Jugendbewegungen im deutschsprachigen Raum (SUSANNE BLUMESBERGER)
184 Ellerbach, Benoît: L’Arabie contée aux Allemands. Fictions interculturelles chez Rafik Schami (ANNETTE KLIEWER)
185 Enklaar, Jattie/ Ester, Hans /Tax, Evelyne (Hrsg.): Studien über Kinder- und Jugendliteratur im europäischen Austausch von 1800 bis heute (IRIS SCHÄFER)
187 Ewers, Hans-Heino: Michael Ende neu entdecken. Was »Jim Knopf«,»Momo« und »Die unendliche Geschichte« Erwachsenen zu sagen haben (MARKUS JANKA)
189 Flegel, Monica/Parkes, Christopher (Hrsg.): Cruel Children in Popular Texts and Cultures (LENA HOFFMANN)
191 Garbe, Christine/Gürth, Christina et al. (Hrsg.): Attraktive Lesestoffe (nicht nur) für Jungen. Erzählmuster und Beispielanalysen zu populärer Kinder- und Jugendliteratur (THOMAS BITTERLICH)
193 Goga, Nina/Kümmerling-Meibauer, Bettina (Hrsg.): Maps and Mapping in Children’s Literature. Landscapes, Seascapes, and Cityscapes (Wolfgang Biesterfeld)
195 Hamer, Naomi /Nodelman, Perry / Reimer, Mavis (Hrsg.): More Words about Pictures. Current Research on Picturebooks and Visual/Verbal Texts for Young People (FARRIBA SCHULZ)
196 Hoffmann, Lena: Crossover. Mehrfachadressierung in Text, Markt und Diskurs (HEIDI LEXE)
198 Josting, Petra/Reuter, Frank/Roeder, Caroline/Wolters, Ute (Hrsg.): »Denn sie rauben sehr geschwind jedes böse Gassenkind.« ›Zigeuner‹-Bilder in Kinder- und Jugendmedien (KURT FRANZ)
200 Langemeyer, Peter /Knutsen, Karen Patrick (Hrsg.): Narratology Plus. Studies in Recent International Narratives for Children and
Young Adults / Narratologie Plus. Studien zur Erzählweise in aktueller internationaler Kinder- und Jugendliteratur (NADINE BIEKER)
202 Museumsinsel Lüttenheid (Hrsg.): Rudolf Dirks. Zwei Lausbuben und die Erfindung des modernen Comics (LUKAS SARVARI)
204 Oeste, Bettina/Preußer, Ulrike (Hrsg.): Neuvermessung deutschsprachiger Erinnerungsstrategien in der Kinder- und Jugendliteratur nach 1990 (annette kliewer)
206 Planka, Sabine (Hrsg.): Berlin. Bilder einer Metropole in erzählenden Medien für Kinder und Jugendliche (KATHARINA EGERER)
208 Press, Alexander: Die Bilder des Comics. Funktionsweisen aus kunst- und bildwissenschaftlicher Perspektive (RALF VOLLBRECHT)
209 Schenk, Klaus /Zeisberg, Ingold (Hrsg.): Fremde Räume. Interkulturalität und Semiotik des Phantastischen (ANNETTE KLIEWER)
211 Schweizerisches Institut für Kinder- und Jugendmedien SIKJM (Hrsg.): Atlas der Schweizer Kinderliteratur. Expeditionen und
Panoramen (SUSANNE RIEGLER)
Sammelrezensionen
213 Heinemann, Caroline: Produktionsräume im zeitgenössischen Kinder- und Jugendtheater. – Hentschel, Ingrid: Theater zwischen Ich und Welt. Beiträge zur Ästhetik des Kinder- und Jugendtheaters. Theorien – Praxis – Geschichte (PHILIPP SCHMERHEIM)
215 Janka, Marcus /Stierstorfer, Michael (Hrsg.): Verjüngte Antike. Griechisch-römische Mythologie in zeitgenössischen Kinder- und Jugendmedien. – Stierstorfer, Michael: Antike Mythologie in der Kinder- und Jugendliteratur der Gegenwart. Unsterbliche Götter- und Heldengeschichten? (KARINA BECKER)
218 Josting, Petra/Kruse, Iris (Hrsg.): Paul Maar. Bielefelder Poet in Residence 2015 | Paderborner Kinderliteraturtage 2016. – Wicke, Andreas /Roßbach, Nikola (Hrsg.): Paul Maar. Studien zum kinder- und jugendliterarischen Werk (SONJA MÜLLER-CARSTENS)
Background: Various studies have been made about the most effective and safest type of treatment for vertebral compression fractures (VCFs). Long-term results are needed for qualitative evaluation.
Purpose: The purpose of the study is to evaluate the effectiveness of percutaneous vertebroplasty (PVP) and percutaneous kyphoplasty (PKP) procedures for VCFs.
Materials and Methods: Forty-nine patients who received either PVP or PKP between 2002 and 2015 returned a specially developed questionnaire and were included in a cross-sectional outcome analysis. The questionnaire assessed pain development by use of a visual analog scale (VAS). Imaging data (CT scans) were retrospectively analyzed for identification of cement leakage.
Results: Patients’ VAS scores significantly decreased after treatment (7.0 ± 3.4 => 3.7 ± 3.4), (p < 0.001). The average pain reduction in patients treated with PVP was −3.3 ± 3.8 (p < 0.001) (median −3.5) and −4.0 ± 3.9 (p < 0.001) (median −4.5) in patients treated with PKP. Fifteen Patients (41.7%) receiving PVP and four patients (30.7%) receiving PKP experienced recurrence of pain. Cement leakage occurred in 10 patients (22.73%). Patients with cement leakage showed comparable VAS scores after treatment (6.8 ± 3.5 => 1.4 ± 1.6), (p = 0.008). Thirty-nine patients reported an increase in mobility (79.6%) and 41 patients an improvement in quality of life (83.7%).
Conclusion: Pain reduction by means of PVP or PKP in patients with VCFs was discernible over the period of observation. Percutaneous vertebroplasty and PKP contribute to the desired treatment results. However, the level of low pain may not remain constant.
Results are presented on event-by-event fluctuations in transverse momentum of charged particles, produced at forward rapidities in p+p, C+C, Si+Si and Pb+Pb collisions at 158 AGeV. Three different characteristics are discussed: the average transverse momentum of the event, the Phi_pT fluctuation measure and two-particle transverse momentum correlations. In the kinematic region explored, the dynamical fluctuations are found to be small. However, a significant system size dependence of Phi_pT is observed, with the largest value measured in peripheral Pb+Pb interactions. The data are compared with predictions of several models. PACS numbers: 14.20.Jn, 13.75.Cs, 12.39.-x
Evidence for an exotic S=-2, Q=-2 baryon resonance in proton-proton collisions at the CERN SPS
(2004)
Results of resonance searches in the Xi - pi -, Xi - pi +, Xi -bar+ pi -, and Xi -bar+ pi + invariant mass spectra in proton-proton collisions at sqrt[s]=17.2 GeV are presented. Evidence is shown for the existence of a narrow Xi - pi - baryon resonance with mass of 1.862±0.002 GeV/c2 and width below the detector resolution of about 0.018 GeV/c2. The significance is estimated to be above 4.2 sigma . This state is a candidate for the hypothetical exotic Xi --3/2 baryon with S=-2, I=3 / 2, and a quark content of (dsdsu-bar). At the same mass, a peak is observed in the Xi - pi + spectrum which is a candidate for the Xi 03/2 member of this isospin quartet with a quark content of (dsusd-bar). The corresponding antibaryon spectra also show enhancements at the same invariant mass.
Observation of an exotic S = -2, Q = -2 baryon resonance in proton-proton collisions at the CERN SPS
(2003)
Results of resonance searches in the Xi- pi-, Xi- pi+, antiXi+ pi- and antiXi+ pi+ invariant mass spectra in proton-proton collisions at sqrt s=17.2 GeV are presented. Evidence is shown for the existence of a narrow Xi- pi- baryon resonance with mass of 1.862+/-0.002 GeV/c^2 and width below the detector resolution of about 0.018 GeV/c^2. The significance is estimated to be 4.0 sigma. This state is a candidate for the hypothetical exotic Xi_(3/2)^-- baryon with S = -2, I = 3/2 and a quark content of (d s d s ubar). At the same mass a peak is observed in the Xi- pi+ spectrum which is a candidate for the Xi_(3/2)^0 member of this isospin quartet with a quark content of (d s u s dbar). The corresponding antibaryon spectra also show enhancements at the same invariant mass.
Report from NA49
(2004)
The most recent data of NA49 on hadron production in nuclear collisions at CERN SPS energies are presented. Anomalies in the energy dependence of pion and kaon production in central Pb+Pb collisions are observed. They suggest that the onset of deconfinement is located at about 30 AGeV. Large multiplicity and transverse momentum fluctuations are measured for collisions of intermediate mass systems at 158 AGeV. The need for a new experimental programme at the CERN SPS is underlined.
Event-by-event fluctuations of particle ratios in central Pb + Pb collisions at 20 to 158 AGeV
(2004)
In the vicinity of the QCD phase transition, critical fluctuations have been predicted to lead to non-statistical fluctuations of particle ratios, depending on the nature of the phase transition. Recent results of the NA49 energy scan program show a sharp maximum of the ratio of K+ to Pi+ yields in central Pb+Pb collisions at beam energies of 20-30 AGeV. This observation has been interpreted as an indication of a phase transition at low SPS energies. We present first results on event-by-event fluctuations of the kaon to pion and proton to pion ratios at beam energies close to this maximum.
A non-monotonic energy dependence of the K + / pi + ratio with a sharp maximum close to 30 A GeV is observed in central Pb+Pb collisions. Within a statistical model of the early stage, this is interpreted as a sign of the phase transition to a QGP, which causes a sharp change in the energy dependence of the strangeness to entropy ratio. This observation naturally motivates us to study the production of multistrange hyperons (Xi, Omega) as a function of the beam energy. Furthermore it was suggested that the kinematic freeze-out of Omega takes place directly at QGP hadronization. If this is indeed the case, the transverse momentum spectra of the Omega directly reflect the transverse expansion velocity of a hadronizing QGP. In this report we show preliminary NA49 results on Omega - and Omega + production in central Pb+Pb collisions at 40 and 158 A GeV and compare them to measurements of Xi - and Xi + production in central Pb+Pb collisions at 30, 40, 80 and 158 A GeV.
Results are presented on event-by-event electric charge fluctuations in central Pb+Pb collisions at 20, 30, 40, 80 and 158 AGeV. The observed fluctuations are close to those expected for a gas of pions correlated by global charge conservation only. These fluctuations are considerably larger than those calculated for an ideal gas of deconfined quarks and gluons. The present measurements do not necessarily exclude reduced fluctuations from a quark-gluon plasma because these might be masked by contributions from resonance decays.
System-size dependence of strangeness production in nucleus-nucleus collisions at √sNN = 17.3 GeV
(2005)
Emission of pi, K, phi and Lambda was measured in near-central C+C and Si+Si collisions at 158 AGeV beam energy. Together with earlier data for p+p, S+S and Pb+Pb, the system-size dependence of relative strangeness production in nucleus-nucleus collisions is obtained. Its fast rise and the saturation observed at about 60 participating nucleons can be understood as onset of the formation of coherent partonic subsystems of increasing size. PACS numbers: 25.75.-q
Production of Lambda and Antilambda hyperons was measured in central Pb-Pb collisions at 40, 80, and 158 A GeV beam energy on a fixed target. Transverse mass spectra and rapidity distributions are given for all three energies. The Lambda/pi ratio at mid-rapidity and in full phase space shows a pronounced maximum between the highest AGS and 40 A GeV SPS energies, whereas the anti-Lambda}/pi ratio exhibits a monotonic increase. PACS numbers: 25.75.-q
Results are presented on Omega production in central Pb+Pb collisions at 40 and 158 AGeV beam energy. Given are transverse-mass spectra, rapidity distributions, and total yields for the sum Omega+Antiomega at 40 AGeV and for Omega and Antiomega separately at 158 AGeV. The yields are strongly under-predicted by the string-hadronic UrQMD model and are in better agreement with predictions from a hadron gas models. PACS numbers: 25.75.Dw
Particle production in central Pb+Pb collisions was studied with the NA49 large acceptance spectrometer at the CERN SPS at beam energies of 20, 30, 40, 80, and 158 GeV per nucleon. A change of the energy dependence is observed around 30A GeV for the yields of pions and strange particles as well as for the shapes of the transverse mass spectra. At present only a reaction scenario with onset of deconfinement is able to reproduce the measurements.
The hadronic final state of central Pb+Pb collisions at 20, 30, 40, 80, and 158 AGeV has been measured by the CERN NA49 collaboration. The mean transverse mass of pions and kaons at midrapidity stays nearly constant in this energy range, whereas at lower energies, at the AGS, a steep increase with beam energy was measured. Compared to p+p collisions as well as to model calculations, anomalies in the energy dependence of pion and kaon production at lower SPS energies are observed. These findings can be explained, assuming that the energy density reached in central A+A collisions at lower SPS energies is sufficient to transform the hot and dense nuclear matter into a deconfined phase.
The hadronic final state of central Pb+Pb collisions at 20, 30, 40, 80, and 158 AGeV has been measured by the CERN NA49 collaboration. The mean transverse mass of pions and kaons at midrapidity stays nearly constant in this energy range, whereas at lower energies, at the AGS, a steep increase with beam energy was measured. Compared to p+p collisions as well as to model calculations, anomalies in the energy dependence of pion and kaon production at lower SPS energies are observed. These findings can be explained, assuming that the energy density reached in central A+A collisions at lower SPS energies is sufficient to force the hot and dense nuclear matter into a deconfined phase.
Dual-energy CT (DECT) has emerged into clinical routine as an imaging technique with unique postprocessing utilities that improve the evaluation of different body areas. The virtual non-calcium (VNCa) reconstruction algorithm has shown beneficial effects on the depiction of bone marrow pathologies such as bone marrow edema. Its main advantage is the ability to substantially increase the image contrast of structures that are usually covered with calcium mineral, such as calcified vessels or bone marrow, and to depict a large number of traumatic, inflammatory, infiltrative, and degenerative disorders affecting either the spine or the appendicular skeleton. Therefore, VNCa imaging represents another step forward for DECT to image conditions and disorders that usually require the use of more expensive and time-consuming techniques such as magnetic resonance imaging, positron emission tomography/CT, or bone scintigraphy. The aim of this review article is to explain the technical background of VNCa imaging, showcase its applicability in the different body regions, and provide an updated outlook on the clinical impact of this technique, which goes beyond the sole improvement in image quality.
Highlights
• MRI and ultrasound provided significant correlations between findings suggestive of vasculitis and the final diagnosis.
• Careful selection of available imaging techniques is warranted considering the time course, location, and clinical history.
• Considering its moderate diagnostic power to distinguish tracer uptake, a holistic view of PET/CT findings is essential.
Abstract
Purpose: To assess the diagnostic value of different imaging modalities in distinguishing systemic vasculitis from other internal and immunological diseases.
Methods: This retrospective study included 134 patients with suspected vasculitis who underwent ultrasound, magnetic resonance imaging (MRI), or 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) between 01/2010 and 01/2019, finally consisting of 70 individuals with vasculitis. The main study parameter was the confirmation of the diagnosis using one of the three different imaging modalities, with the adjudicated clinical and histopathological diagnosis as the gold standard. A secondary parameter was the morphological appearance of the vessel affected by vasculitis.
Results: Patients with systemic vasculitis had myriad clinical manifestations with joint pain as the most common symptom. We found significant correlations between different imaging findings suggestive of vasculitis and the final adjudicated clinical diagnosis. In this context, on MRI, vessel wall thickening, edema, and diameter differed significantly between vasculitis and non-vasculitis groups (p < 0.05). Ultrasound revealed different findings that may serve as red flags in identifying patients with vasculitis, such as vascular occlusion or halo sign (p = 0.02 vs. non-vasculitis group). Interestingly, comparing maximal standardized uptake values from PET/CT examinations with vessel wall thickening or vessel diameter did not result in significant differences (p > 0.05).
Conclusions: We observed significant correlations between different imaging findings suggestive of vasculitis on ultrasound or MRI and the final adjudicated diagnosis. While ultrasound and MRI were considered suitable imaging methods for detecting and discriminating typical vascular changes, 18F-FDG PET/CT requires careful timing and patient selection given its moderate diagnostic accuracy.
Objectives: To determine the diagnostic accuracy of dual-energy CT (DECT) virtual noncalcium (VNCa) reconstructions for assessing thoracic disk herniation compared to standard grayscale CT. Methods: In this retrospective study, 87 patients (1131 intervertebral disks; mean age, 66 years; 47 women) who underwent third-generation dual-source DECT and 3.0-T MRI within 3 weeks between November 2016 and April 2020 were included. Five blinded radiologists analyzed standard DECT and color-coded VNCa images after a time interval of 8 weeks for the presence and degree of thoracic disk herniation and spinal nerve root impingement. Consensus reading of independently evaluated MRI series served as the reference standard, assessed by two separate experienced readers. Additionally, image ratings were carried out by using 5-point Likert scales. Results: MRI revealed a total of 133 herniated thoracic disks. Color-coded VNCa images yielded higher overall sensitivity (624/665 [94%; 95% CI, 0.89–0.96] vs 485/665 [73%; 95% CI, 0.67–0.80]), specificity (4775/4990 [96%; 95% CI, 0.90–0.98] vs 4066/4990 [82%; 95% CI, 0.79–0.84]), and accuracy (5399/5655 [96%; 95% CI, 0.93–0.98] vs 4551/5655 [81%; 95% CI, 0.74–0.86]) for the assessment of thoracic disk herniation compared to standard CT (all p < .001). Interrater agreement was excellent for VNCa and fair for standard CT (ϰ = 0.82 vs 0.37; p < .001). In addition, VNCa imaging achieved higher scores regarding diagnostic confidence, image quality, and noise compared to standard CT (all p < .001). Conclusions: Color-coded VNCa imaging yielded substantially higher diagnostic accuracy and confidence for assessing thoracic disk herniation compared to standard CT.
This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95–23.01) to 2.36 μSv (IQR, 0.52–12.66) (−36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 μSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 μSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (−30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.
Background: Dual-source dual-energy computed tomography (DECT) offers the potential for opportunistic osteoporosis screening by enabling phantomless bone mineral density (BMD) quantification. This study sought to assess the accuracy and precision of volumetric BMD measurement using dual-source DECT in comparison to quantitative CT (QCT). Methods: A validated spine phantom consisting of three lumbar vertebra equivalents with 50 (L1), 100 (L2), and 200 mg/cm3 (L3) calcium hydroxyapatite (HA) concentrations was scanned employing third-generation dual-source DECT and QCT. While BMD assessment based on QCT required an additional standardised bone density calibration phantom, the DECT technique operated by using a dedicated postprocessing software based on material decomposition without requiring calibration phantoms. Accuracy and precision of both modalities were compared by calculating measurement errors. In addition, correlation and agreement analyses were performed using Pearson correlation, linear regression, and Bland-Altman plots. Results: DECT-derived BMD values differed significantly from those obtained by QCT (p < 0.001) and were found to be closer to true HA concentrations. Relative measurement errors were significantly smaller for DECT in comparison to QCT (L1, 0.94% versus 9.68%; L2, 0.28% versus 5.74%; L3, 0.24% versus 3.67%, respectively). DECT demonstrated better BMD measurement repeatability compared to QCT (coefficient of variance < 4.29% for DECT, < 6.74% for QCT). Both methods correlated well to each other (r = 0.9993; 95% confidence interval 0.9984–0.9997; p < 0.001) and revealed substantial agreement in Bland-Altman plots. Conclusions: Phantomless dual-source DECT-based BMD assessment of lumbar vertebra equivalents using material decomposition showed higher diagnostic accuracy compared to QCT.
Objectives: To compare dual-energy CT (DECT) and MRI for assessing presence and extent of traumatic bone marrow edema (BME) and fracture line depiction in acute vertebral fractures. Methods: Eighty-eight consecutive patients who underwent dual-source DECT and 3-T MRI of the spine were retrospectively analyzed. Five radiologists assessed all vertebrae for presence and extent of BME and for identification of acute fracture lines on MRI and, after 12 weeks, on DECT series. Additionally, image quality, image noise, and diagnostic confidence for overall diagnosis of acute vertebral fracture were assessed. Quantitative analysis of CT numbers was performed by a sixth radiologist. Two radiologists analyzed MRI and grayscale DECT series to define the reference standard. Results: For assessing BME presence and extent, DECT showed high sensitivity (89% and 84%, respectively) and specificity (98% in both), and similarly high diagnostic confidence compared to MRI (2.30 vs. 2.32; range 0–3) for the detection of BME (p = .72). For evaluating acute fracture lines, MRI achieved high specificity (95%), moderate sensitivity (76%), and a significantly lower diagnostic confidence compared to DECT (2.42 vs. 2.62, range 0–3) (p < .001). A cutoff value of − 0.43 HU provided a sensitivity of 89% and a specificity of 90% for diagnosing BME, with an overall AUC of 0.96. Conclusions: DECT and MRI provide high diagnostic confidence and image quality for assessing acute vertebral fractures. While DECT achieved high overall diagnostic accuracy in the analysis of BME presence and extent, MRI provided moderate sensitivity and lower confidence for evaluating fracture lines.
Purpose: To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography scans (CTA) or a specifically designed phantom model.
Methods: This retrospective study included 23 patients with confirmed TAA on routinely performed CTAs. In addition to phantom tube diameters, one experienced blinded radiologist evaluated the dimensions of TAAs on three different workstations in two separate rounds. Precision was assessed by calculating measurement errors. In addition, correlation analysis was performed using Pearson correlation.
Results: Measurements acquired at the Siemens workstation deviated by 3.54% (range, 2.78–4.03%; p = 0.14) from the true size, those at General Electric by 4.05% (range, 1.46–7.09%; p < 0.0001), and at TeraRecon by 4.86% (range, 3.22–6.45%; p < 0.0001). Accordingly, Siemens provided the most precise workstation at simultaneously most fluctuating values (scattering of 4.46%). TeraRecon had the smallest fluctuation (scattering of 2.83%), but the largest deviation from the true size of the phantom. The workstation from General Electric showed a scattering of 2.94%. The highest overall correlation between the 1st and 2nd rounds was observed with measurements from Siemens (r = 0.898), followed by TeraRecon (r = 0.799), and General Electric (r = 0.703). Repetition of measurements reduced processing times by 40% when using General Electric, by 20% with Siemens, and by 18% with TeraRecon.
Conclusions: In conclusion, all three workstations facilitated precise assessment of dimensions in the majority of cases at simultaneously high reproducibility, ensuring accurate pre-interventional planning of thoracic endovascular aortic repair.
Background: To assess the potential of radiomic features to quantify components of blood in intraaortic vessels to non-invasively predict moderate-to-severe anemia in non-contrast enhanced CT scans. Methods: One hundred patients (median age, 69 years; range, 19–94 years) who received CT scans of the thoracolumbar spine and blood-testing for hemoglobin and hematocrit levels ± 24 h between 08/2018 and 11/2019 were retrospectively included. Intraaortic blood was segmented using a spherical volume of interest of 1 cm diameter with consecutive radiomic analysis applying PyRadiomics software. Feature selection was performed applying analysis of correlation and collinearity. The final feature set was obtained to differentiate moderate-to-severe anemia. Random forest machine learning was applied and predictive performance was assessed. A decision-tree was obtained to propose a cut-off value of CT Hounsfield units (HU). Results: High correlation with hemoglobin and hematocrit levels was shown for first-order radiomic features (p < 0.001 to p = 0.032). The top 3 features showed high correlation to hemoglobin values (p) and minimal collinearity (r) to the top ranked feature Median (p < 0.001), Energy (p = 0.002, r = 0.387), Minimum (p = 0.032, r = 0.437). Median (p < 0.001) and Minimum (p = 0.003) differed in moderate-to-severe anemia compared to non-anemic state. Median yielded superiority to the combination of Median and Minimum (p(AUC) = 0.015, p(precision) = 0.017, p(accuracy) = 0.612) in the predictive performance employing random forest analysis. A Median HU value ≤ 36.5 indicated moderate-to-severe anemia (accuracy = 0.90, precision = 0.80). Conclusions: First-order radiomic features correlate with hemoglobin levels and may be feasible for the prediction of moderate-to-severe anemia. High dimensional radiomic features did not aid augmenting the data in our exemplary use case of intraluminal blood component assessment.
Purpose: To identify transjugular intrahepatic portosystemic shunt (TIPS) thrombosis in abdominal CT scans applying quantitative image analysis.
Materials and methods: We retrospectively screened 184 patients to include 20 patients (male, 8; female, 12; mean age, 60.7 ± 8.87 years) with (case, n = 10) and without (control, n = 10) in-TIPS thrombosis who underwent clinically indicated contrast-enhanced and unenhanced abdominal CT followed by conventional TIPS-angiography between 08/2014 and 06/2020. First, images were scored visually. Second, region of interest (ROI) based quantitative measurements of CT attenuation were performed in the inferior vena cava (IVC), portal vein and in four TIPS locations. Minimum, maximum and average Hounsfield unit (HU) values were used as absolute and relative quantitative features. We analyzed the features with univariate testing.
Results: Subjective scores identified in-TIPS thrombosis in contrast-enhanced scans with an accuracy of 0.667 – 0.833. Patients with in-TIPS thrombosis had significantly lower average (p < 0.001), minimum (p < 0.001) and maximum HU (p = 0.043) in contrast-enhanced images. The in-TIPS / IVC ratio in contrast-enhanced images was significantly lower in patients with in-TIPS thrombosis (p < 0.001). No significant differences were found for unenhanced images. Analyzing the visually most suspicious ROI with consecutive calculation of its ratio to the IVC, all patients with a ratio < 1 suffered from in-TIPS thrombosis (p < 0.001, sensitivity and specificity = 100%).
Conclusion: Quantitative analysis of abdominal CT scans facilitates the stratification of in-TIPS thrombosis. In contrast-enhanced scans, an in-TIPS / IVC ratio < 1 could non-invasively stratify all patients with in-TIPS thrombosis.
Introduction: Recommendations for venous thromboembolism and deep venous thrombosis (DVT) prophylaxis using graduated compression stockings (GCS) is historically based and has been critically examined in current publications. Existing guidelines are inconclusive as to recommend the general use of GCS.
Patients/Methods: 24 273 in-patients (general surgery and orthopedic patients) undergoing surgery between 2006 and 2016 were included in a retrospectively analysis from a single center. From January 2006 to January 2011 perioperative GCS was employed additionally to drug prophylaxis and from February 2011 to March 2016 patients received drug prophylaxis alone. According to german guidelines all patients received venous thromboembolism prophylaxis with weight-adapted LMWH. Risk stratification (low risk, moderate risk, high risk) was based on the guideline of the American College of Chest Physicians. Data analysis was performed before and after propensity matching (PM). The defined primary endpoint was the incidence of symptomatic or fatal pulmonary embolism (PE). A secondary endpoint was the incidence of deep venous thromboembolism (DVT).
Results: After risk stratification (low risk n = 16 483; moderate risk n = 4464; high risk n = 3326) a total of 24 273 patient were analyzed. Before to PM the relative risk for the occurrence of a PE or DVT was not increased by abstaining from GCS. After PM two groups of 11 312 patients each, one with and one without GCS application, were formed. When comparing the two groups, the relative risk (RR) for the occurrence of a pulmonary embolism was: Low Risk 0.99 [CI95% 0.998–1.000]; Moderate Risk 0.999 [CI95% 0.95–1.003]; High Risk 0.996 [CI95% 0.992–1.000] (p > 0.05). The incidence of PE in the total group LMWH alone was 0.1% (n = 16). In the total group using LMWH + GCS, the incidence was 0.3% (n = 29). RR after PM was 0.999 [CI95% 0.998–1.00].
Conclusion: In comparison to prior studies with only small numbers of patients our trial shows in a large group of patients with moderate and high risk developing VTE we can support the view that abstaining from GCS-use does not increase the incidence of symptomatic or fatal PE and symptomatic DVT.
Objectives: To analyze the performance of radiological assessment categories and quantitative computational analysis of apparent diffusion coefficient (ADC) maps using variant machine learning algorithms to differentiate clinically significant versus insignificant prostate cancer (PCa). Methods: Retrospectively, 73 patients were included in the study. The patients (mean age, 66.3 ± 7.6 years) were examined with multiparametric MRI (mpMRI) prior to radical prostatectomy (n = 33) or targeted biopsy (n = 40). The index lesion was annotated in MRI ADC and the equivalent histologic slides according to the highest Gleason Grade Group (GrG). Volumes of interest (VOIs) were determined for each lesion and normal-appearing peripheral zone. VOIs were processed by radiomic analysis. For the classification of lesions according to their clinical significance (GrG ≥ 3), principal component (PC) analysis, univariate analysis (UA) with consecutive support vector machines, neural networks, and random forest analysis were performed. Results: PC analysis discriminated between benign and malignant prostate tissue. PC evaluation yielded no stratification of PCa lesions according to their clinical significance, but UA revealed differences in clinical assessment categories and radiomic features. We trained three classification models with fifteen feature subsets. We identified a subset of shape features which improved the diagnostic accuracy of the clinical assessment categories (maximum increase in diagnostic accuracy ΔAUC = + 0.05, p < 0.001) while also identifying combinations of features and models which reduced overall accuracy. Conclusions: The impact of radiomic features to differentiate PCa lesions according to their clinical significance remains controversial. It depends on feature selection and the employed machine learning algorithms. It can result in improvement or reduction of diagnostic performance.
Myocardial fibrosis and inflammation by CMR predict cardiovascular outcome in people living with HIV
(2021)
Objectives_: The goal of this study was to examine prognostic relationships between cardiac imaging measures and cardiovascular outcome in people living with human immunodeficiency virus (HIV) (PLWH) on highly active antiretroviral therapy (HAART).
Background: PLWH have a higher prevalence of cardiovascular disease and heart failure (HF) compared with the noninfected population. The pathophysiological drivers of myocardial dysfunction and worse cardiovascular outcome in HIV remain poorly understood.
Methods: This prospective observational longitudinal study included consecutive PLWH on long-term HAART undergoing cardiac magnetic resonance (CMR) examination for assessment of myocardial volumes and function, T1 and T2 mapping, perfusion, and scar. Time-to-event analysis was performed from the index CMR examination to the first single event per patient. The primary endpoint was an adjudicated adverse cardiovascular event (cardiovascular mortality, nonfatal acute coronary syndrome, an appropriate device discharge, or a documented HF hospitalization).
Results: A total of 156 participants (62% male; age [median, interquartile range]: 50 years [42 to 57 years]) were included. During a median follow-up of 13 months (9 to 19 months), 24 events were observed (4 HF deaths, 1 sudden cardiac death, 2 nonfatal acute myocardial infarction, 1 appropriate device discharge, and 16 HF hospitalizations). Patients with events had higher native T1 (median [interquartile range]: 1,149 ms [1,115 to 1,163 ms] vs. 1,110 ms [1,075 to 1,138 ms]); native T2 (40 ms [38 to 41 ms] vs. 37 ms [36 to 39 ms]); left ventricular (LV) mass index (65 g/m2 [49 to 77 g/m2] vs. 57 g/m2 [49 to 64 g/m2]), and N-terminal pro–B-type natriuretic peptide (109 pg/l [25 to 337 pg/l] vs. 48 pg/l [23 to 82 pg/l]) (all p < 0.05). In multivariable analyses, native T1 was independently predictive of adverse events (chi-square test, 15.9; p < 0.001; native T1 [10 ms] hazard ratio [95% confidence interval]: 1.20 [1.08 to 1.33]; p = 0.001), followed by a model that also included LV mass (chi-square test, 17.1; p < 0.001). Traditional cardiovascular risk scores were not predictive of the adverse events.
Conclusions: Our findings reveal important prognostic associations of diffuse myocardial fibrosis and LV remodeling in PLWH. These results may support development of personalized approaches to screening and early intervention to reduce the burden of HF in PLWH (International T1 Multicenter Outcome Study; NCT03749343).
Highlights
• Assessment of coronary artery plaque burden according to the CAC-DRS Score correlated well with pulmonary involvement of SARS-CoV-2 pneumonia (min. r=0.81, 95% CI 0.76 to 0.86).
• Visual and quantitative CAC-DRS Score of coronary artery plaque burden provided independent prognostic information on all-cause mortality in patients with SARS-CoV-2 pneumonia (p=0.0016 and p<0.0001, respectively).
• Incorporating CAC-DRS Score and pulmonary involvement into clinical decision making revealed great potential to discriminate patients with fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89 to 0.97) and the need for intensive care treatment (AUC 0.801, 95% CI 0.77 to 0.83).
Purpose: To assess and correlate pulmonary involvement and outcome of SARS-CoV-2 pneumonia with the degree of coronary plaque burden based on the CAC-DRS classification (Coronary Artery Calcium Data and Reporting System).
Methods: This retrospective study included 142 patients with confirmed SARS-CoV-2 pneumonia (58 ± 16 years; 57 women) who underwent non-contrast CT between January 2020 and August 2021 and were followed up for 129 ± 72 days. One experienced blinded radiologist analyzed CT series for the presence and extent of calcified plaque burden according to the visual and quantitative HU-based CAC-DRS Score. Pulmonary involvement was automatically evaluated with a dedicated software prototype by another two experienced radiologists and expressed as Opacity Score.
Results: CAC-DRS Scores derived from visual and quantitative image evaluation correlated well with the Opacity Score (r=0.81, 95% CI 0.76-0.86, and r=0.83, 95% CI 0.77-0.89, respectively; p<0.0001) with higher correlation in severe than in mild stage SARS-CoV-2 pneumonia (p<0.0001). Combined, CAC-DRS and Opacity Scores revealed great potential to discriminate fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89-0.97), and the need for intensive care treatment (AUC 0.801, 95% CI 0.77-0.83). Visual and quantitative CAC-DRS Scores provided independent prognostic information on all-cause mortality (p=0.0016 and p<0.0001, respectively), both in univariate and multivariate analysis.
Conclusions: Coronary plaque burden is strongly correlated to pulmonary involvement, adverse outcome, and death due to respiratory failure in patients with SARS-CoV-2 pneumonia, offering great potential to identify individuals at high risk.
Purpose
To assess the diagnostic value of different imaging modalities in distinguishing systemic vasculitis from other internal and immunological diseases.
Methods
This retrospective study included 134 patients with suspected vasculitis who underwent ultrasound, magnetic resonance imaging (MRI), or 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) between 01/2010 and 01/2019, finally consisting of 70 individuals with vasculitis. The main study parameter was the confirmation of the diagnosis using one of the three different imaging modalities, with the adjudicated clinical and histopathological diagnosis as the gold standard. A secondary parameter was the morphological appearance of the vessel affected by vasculitis.
Results
Patients with systemic vasculitis had myriad clinical manifestations with joint pain as the most common symptom. We found significant correlations between different imaging findings suggestive of vasculitis and the final adjudicated clinical diagnosis. In this context, on MRI, vessel wall thickening, edema, and diameter differed significantly between vasculitis and non-vasculitis groups (p < 0.05). Ultrasound revealed different findings that may serve as red flags in identifying patients with vasculitis, such as vascular occlusion or halo sign (p = 0.02 vs. non-vasculitis group). Interestingly, comparing maximal standardized uptake values from PET/CT examinations with vessel wall thickening or vessel diameter did not result in significant differences (p > 0.05).
Conclusions
We observed significant correlations between different imaging findings suggestive of vasculitis on ultrasound or MRI and the final adjudicated diagnosis. While ultrasound and MRI were considered suitable imaging methods for detecting and discriminating typical vascular changes, 18F-FDG PET/CT requires careful timing and patient selection given its moderate diagnostic accuracy.
Objectives: To assess the impact of noise-optimised virtual monoenergetic imaging (VMI+) on image quality and diagnostic evaluation in abdominal dual-energy CT scans with impaired portal-venous contrast.
Methods: We screened 11,746 patients who underwent portal-venous abdominal dual-energy CT for cancer staging between 08/2014 and 11/2019 and identified those with poor portal-venous contrast.
Standard linearly-blended image series and VMI+ image series at 40, 50, and 60 keV were reconstructed. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of abdominal organs and vascular structures were calculated. Image noise, image contrast and overall image quality were rated by three radiologists using 5-point Likert scale.
Results: 452 of 11,746 (4%) exams were poorly opacified. We excluded 190 cases due to incomplete datasets or multiple exams of the same patient with a final study group of 262. Highest CNR values in all abdominal organs (liver, 6.4 ± 3.0; kidney, 17.4 ± 7.5; spleen, 8.0 ± 3.5) and vascular structures (aorta, 16.0 ± 7.3; intrahepatic vein, 11.3 ± 4.7; portal vein, 15.5 ± 6.7) were measured at 40 keV VMI+ with significantly superior values compared to all other series. In subjective analysis, highest image contrast was seen at 40 keV VMI+ (4.8 ± 0.4), whereas overall image quality peaked at 50 keV VMI+ (4.2 ± 0.5) with significantly superior results compared to all other series (p < 0.001).
Conclusions: Image reconstruction using VMI+ algorithm at 50 keV significantly improves image contrast and image quality of originally poorly opacified abdominal CT scans and reduces the number of non-diagnostic scans.
Advances in knowledge: We validated the impact of VMI+ reconstructions in poorly attenuated DECT studies of the abdomen in a big data cohort.
This paper proposes that we can predict which adverbs cannot adjoin to the right in headinitial languages by means of a particular semantic property, that of being a "subjective" adverb, one which maps an event or proposition onto a scale with the high degree of indeterminacy and context-dependence. Such adverbs, such as 'probably' or 'luckily', cannot adjoin to the right with non-manner readings, while other adverbs (like 'politically', 'often', or 'deliberately') may. This supports the view that the distribution of adverbs depends heavily, and subtly, on their lexicosemantic properties.