Refine
Language
- English (9)
Has Fulltext
- yes (9)
Is part of the Bibliography
- no (9)
Keywords
- Advanced treatment technologies (1)
- Bioaccumulation (1)
- Biodiversity (1)
- Conservation biology (1)
- Electron-pion identification (1)
- Emerging contaminants (ECs) (1)
- Endocrine-disrupting compounds (1)
- Environmental fate (1)
- Environmental impact (1)
- Environmental partitioning (1)
- Environmental risk assessment (1)
- Equilibrium partitioning theory (1)
- Fibre/foam sandwich radiator (1)
- Ionisation energy loss (1)
- Multi-wire proportional drift chamber (1)
- Neural network (1)
- Risk metrics (risk quotients, toxic units, hazard units) (1)
- TR (1)
- Tracking (1)
- Transition radiation detector (1)
- Trigger (1)
- Wastewater treatment plant (WWTP) effluents (1)
- Wide-scope chemical target screening (1)
- Xenon-based gas mixture (1)
- dE/dx (1)
- energy-dispersive x-ray spectroscopy (1)
- quantum electrodynamics test (1)
- storage rings (1)
- strong Coulomb field (1)
Institute
Background Ongoing changes in cancer care cause an increase in the complexity of cases which is characterized by modern treatment techniques and a higher demand for patient information about the underlying disease and therapeutic options. At the same time, the restructuring of health services and reduced funding have led to the downsizing of hospital care services. These trends strongly influence the workplace environment and are a potential source of stress and burnout among professionals working in radiotherapy. Methods and patients A postal survey was sent to members of the workgroup "Quality of Life" which is part of DEGRO (German Society for Radiooncology). Thus far, 11 departments have answered the survey. 406 (76.1%) out of 534 cancer care workers (23% physicians, 35% radiographers, 31% nurses, 11% physicists) from 8 university hospitals and 3 general hospitals completed the FBAS form (Stress Questionnaire of Physicians and Nurses; 42 items, 7 scales), and a self-designed questionnaire regarding work situation and one question on global job satisfaction. Furthermore, the participants could make voluntary suggestions about how to improve their situation. Results Nurses and physicians showed the highest level of job stress (total score 2.2 and 2.1). The greatest source of job stress (physicians, nurses and radiographers) stemmed from structural conditions (e.g. underpayment, ringing of the telephone) a "stress by compassion" (e.g. "long suffering of patients", "patients will be kept alive using all available resources against the conviction of staff"). In multivariate analyses professional group (p < 0.001), working night shifts (p = 0.001), age group (p = 0.012) and free time compensation (p = 0.024) gained significance for total FBAS score. Global job satisfaction was 4.1 on a 9-point scale (from 1 – very satisfied to 9 – not satisfied). Comparing the total stress scores of the hospitals and job groups we found significant differences in nurses (p = 0.005) and physicists (p = 0.042) and a borderline significance in physicians (p = 0.052). In multivariate analyses "professional group" (p = 0.006) and "vocational experience" (p = 0.036) were associated with job satisfaction (cancer care workers with < 2 years of vocational experience having a higher global job satisfaction). The total FBAS score correlated with job satisfaction (Spearman-Rho = 0.40; p < 0.001). Conclusion Current workplace environments have a negative impact on stress levels and the satisfaction of radiotherapy staff. Identification and removal of the above-mentioned critical points requires various changes which should lead to the reduction of stress.
Recently, the potent antiandrogen 4-methyl-7-diethylaminocoumarin (C47) and its potential transformation products 4-methyl-7-ethylaminocoumarin (C47T1) and 4-methyl-7-aminocoumarin (C47T2) were identified as novel environmental contaminants. We assessed for the first time the sources, distribution, and fate of these compounds in aquatic systems using the Holtemme River (Saxony-Anhalt, Germany), which is a hotspot for these contaminants. To this end, wastewater-treatment plant (WWTP) influent and effluent samples, surface water samples over 3 years, and the longitudinal profiles in water, sediment, and gammarids were analyzed. From the longitudinal profile of the river stretch, the WWTP of Silstedt was identified as the sole point source for these compounds in the River Holtemme, and exposure concentrations in the low micrograms per liter range could be recorded continuously over 3 years. Analysis of WWTP influent and effluent showed a transformation of approximately half of the C47 into C47T1 and C47T2 but no complete removal. A further attenuation of the three coumarins after discharge into the river could be largely attributed to dilution, while transformation was only approximately 20%, thus suggesting a significant persistence in aquatic systems. Experimentally derived partitioning coefficients between water and sediment organic carbon exceeded those predicted using the OPERA quantitative structure–activity relationship tools and polyparameter linear free-energy relationships by up to 93-fold, suggesting cation binding as a significant factor for their sorption behavior. Near-equilibrium conditions between water and sediment were not observed close to the emitting WWTP but farther downstream in the river. Experimental and predicted bioaccumulation factors for gammarids were closely matching, and the concentrations in field-sampled gammarids were close to steady state with exposure concentrations in the water phase of the river. Environ Toxicol Chem 2021;40:3078–3091. © 2021 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals LLC on behalf of SETAC.
A risk based assessment approach for chemical mixtures from wastewater treatment plant effluents
(2022)
In this study, 56 effluent samples from 52 European wastewater treatment plants (WWTPs) were investigated for the occurrence of 499 emerging chemicals (ECs) and their associated potential risks to the environment. The two main objectives were (i) to extend our knowledge on chemicals occurring in treated wastewater, and (ii) to identify and prioritize compounds of concern based on three different risk assessment approaches for the identification of consensus mixture risk drivers of concern. Approaches include (i) PNEC and EQS-based regulatory risk quotients (RQs), (ii) species sensitivity distribution (SSD)-based hazard units (HUs) and (iii) toxic units (TUs) for three biological quality elements (BQEs) algae, crustacean, and fish.
For this purpose, solid-phase extracts were analysed with wide-scope chemical target screening via liquid chromatography high-resolution mass spectrometry (LC-HRMS), resulting in 366 detected compounds, with concentrations ranging from < 1 ng/L to > 100 µg/L. The detected chemicals were categorized with respect to critical information relevant for risk assessment and management prioritization including: (1) frequency of occurrence, (2) measured concentrations, (3) use groups, (4) persistence & bioaccumulation, and (5) modes of action. A comprehensive assessment using RQ, HU and TU indicated exceedance of risk thresholds for the majority of effluents with RQ being the most sensitive metric. In total, 299 out of the 366 compounds were identified as mixture risk contributors in one of the approaches, while 32 chemicals were established as consensus mixture risk contributors of high concern, including a high percentage (66%) of pesticides and biocides. For samples which have passed an advanced treatment using ozonation or activated carbon (AC), consistently much lower risks were estimated.
Background & aims: Current guidelines recommend immunosuppressive treatment (IT) in patients with primary sclerosing cholangitis (PSC) and elevated aminotransferase levels more than five times the upper limit of normal and elevated serum IgG-levels above twice the upper limit of normal. Since there is no evidence to support this recommendation, we aimed to assess the criteria that guided clinicians in clinical practice to initiate IT in patients with previously diagnosed PSC.
Methods: This is a retrospective analysis of 196 PSC patients from seven German hepatology centers, of whom 36 patients had received IT solely for their liver disease during the course of PSC. Analyses were carried out using methods for competing risks.
Results: A simplified autoimmune hepatitis (AIH) score >5 (HR of 36, p<0.0001) and a modified histological activity index (mHAI) greater than 3/18 points (HR 3.6, p = 0.0274) were associated with the initiation of IT during the course of PSC. Of note, PSC patients who subsequently received IT differed already at the time of PSC diagnosis from those patients, who did not receive IT during follow-up: they presented with increased levels of IgG (p = 0.004) and more frequently had clinical signs of cirrhosis (p = 0.0002).
Conclusions: This is the first study which investigates the parameters associated with IT in patients with PSC in clinical practice. A simplified AIH score >5 and a mHAI score >3, suggesting concomitant features of AIH, influenced the decision to introduce IT during the course of PSC. In German clinical practice, the cutoffs used to guide IT may be lower than recommended by current guidelines.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p–Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
Accurate spectroscopy of highly-charged high-Z ions in a storage ring is demonstrated to be feasible by the use of specially adapted crystal optics. The method has been applied for the measurement of the 1s Lamb shift in hydrogen-like gold (Au+78) in a storage ring through spectroscopy of the Lyman x-rays. This measurement represents the first result obtained for a high-Z element using high-resolution wavelength-dispersive spectroscopy in the hard x-ray regime, paving the way for sensitivity to higher- order QED effects.