Refine
Year of publication
Language
- English (835)
Has Fulltext
- yes (835)
Is part of the Bibliography
- no (835)
Keywords
- Heavy Ion Experiments (12)
- Hadron-Hadron Scattering (11)
- LHC (9)
- ALICE experiment (4)
- Collective Flow (4)
- Jets (4)
- Quark-Gluon Plasma (4)
- ALICE (3)
- Hadron-Hadron scattering (experiments) (3)
- Heavy Ions (3)
Institute
- Physik (819)
- Frankfurt Institute for Advanced Studies (FIAS) (734)
- Informatik (700)
- Geowissenschaften / Geographie (3)
- Informatik und Mathematik (3)
- Geowissenschaften (2)
- Hochschulrechenzentrum (2)
- Medizin (1)
We present the first measurements of femtoscopic correlations between the K0 S and K± particles in pp collisions at √s = 7 TeV measured by the ALICE experiment. The observed femtoscopic correlations are consistent with final-state interactions proceeding solely via the a0(980) resonance. The extracted kaon source radius and correlation strength parameters for K0 SK− are found to be equal within the experimental uncertainties to those for K0 SK+. Results of the present study are compared with those from identical-kaon femtoscopic studies also performed with pp collisions at √s = 7 TeV by ALICE andwith a K0 SK± measurement in Pb–Pb collisions at √sNN = 2.76 TeV. Combined with the Pb–Pb results, our pp analysis is found to be compatible with th e interpretation of the a0(980) having a tetraquark structure instead of that of a diquark.
The procedure for the energy calibration of the high granularity electromagnetic calorimeter PHOS of the ALICE experiment is presented. The methods used to perform the relative gain calibration, to evaluate the geometrical alignment and the corresponding correction of the absolute energy scale, to obtain the nonlinearity correction coefficients and finally, to calculate the time-dependent calibration corrections, are discussed and illustrated by the PHOS performance in proton-proton (pp) collisions at s√=13 TeV. After applying all corrections, the achieved mass resolution of π0 and η mesons for pT>1.7 GeV/c is σπ0m=4.56±0.03 MeV/c2 and σηm=15.3±1.0 MeV/c2.
The procedure for the energy calibration of the high granularity electromagnetic calorimeter PHOS of the ALICE experiment is presented. The methods used to perform the relative gain calibration, to evaluate the geometrical alignment and the corresponding correction of the absolute energy scale, to obtain the nonlinearity correction coefficients and finally, to calculate the time-dependent calibration corrections, are discussed and illustrated by the PHOS performance in proton-proton (pp) collisions at s√ = 13 TeV. After applying all corrections, the achieved mass resolutions for π0 and η mesons for pT>1.7 GeV/c are σπ0m=4.56±0.03 MeV/c2 and σηm=15.3±1.0 MeV/c2, respectively.
Measurement of iodine species and sulfuric acid using bromide chemical ionization mass spectrometers
(2021)
Iodine species are important in the marine atmosphere for oxidation and new-particle formation. Understanding iodine chemistry and iodine new-particle formation requires high time resolution, high sensitivity, and simultaneous measurements of many iodine species. Here, we describe the application of a bromide chemical ionization mass spectrometer (Br-CIMS) to this task. During the iodine oxidation experiments in the Cosmics Leaving OUtdoor Droplets (CLOUD) chamber, we have measured gas-phase iodine species and sulfuric acid using two Br-CIMS, one coupled to a Multi-scheme chemical IONization inlet (Br-MION-CIMS) and the other to a Filter Inlet for Gasses and AEROsols inlet (Br-FIGAERO-CIMS). From offline calibrations and intercomparisons with other instruments, we have quantified the sensitivities of the Br-MION-CIMS to HOI, I2, and H2SO4 and obtained detection limits of 5.8 × 106, 3.8 × 105, and 2.0 × 105 molec. cm−3, respectively, for a 2 min integration time. From binding energy calculations, we estimate the detection limit for HIO3 to be 1.2 × 105 molec. cm−3, based on an assumption of maximum sensitivity. Detection limits in the Br-FIGAERO-CIMS are around 1 order of magnitude higher than those in the Br-MION-CIMS; for example, the detection limits for HOI and HIO3 are 3.3 × 107 and 5.1 × 106 molec. cm−3, respectively. Our comparisons of the performance of the MION inlet and the FIGAERO inlet show that bromide chemical ionization mass spectrometers using either atmospheric pressure or reduced pressure interfaces are well-matched to measuring iodine species and sulfuric acid in marine environments.
"High-aluminous coal" is an important coal kind and widely distributed in North China in age of Permo-Carboniferous period. To explore their occurrence state, a total of 15 harmful elements (Li, Ga, In, Cd, Cr, Pb, Be, Mn, Zn, Ag, Co, Ni, Cu, Ba and U) in the No.9 coal and No.11 coal collected from Pingshuo mining district were determined by inductively coupled plasma mass spectrometry (ICP-MS) and scanning electron microscope with energy spectrum (SEM-EDX). The results showed that the content of Li, Ga, In, Pb, Ag and U were all exceed the world hard coal. In view of the result of clustering analysis within trace elements, it was found that Co, Ni, Zn, Cu, Ag and Cr were mainly associated with sulfide minerals due to their common sulfophilic property. Manganese was mainly occurred in carbonate minerals, while Ba, Cd and U were mainly associated with total minerals. In addition, Pb was related to sulfides and Be is mainly distributed in clay minerals. The enrichment of such harmful elements in Pingshuo coal was caused by the combined effect of transgression and input of terrestrial materials in the peat accumulation stage. Li, Ga, In and Ag have reached the harmful grade.