Using a data sample of e+e− collision data corresponding to an integrated luminosity of 2.93 fb−1 collected with the BESIII detector at a center-of-mass energy of s=3.773GeV, we search for the singly Cabibbo-suppressed decays D0→π0π0π0, π0π0η, π0ηη and ηηη using the double tag method. The absolute branching fractions are measured to be B(D0→π0π0π0)=(2.0±0.4±0.3)×10−4, B(D0→π0π0η)=(3.8±1.1±0.7)×10−4 and B(D0→π0ηη)=(7.3±1.6±1.5)×10−4 with the statistical significances of 4.8σ, 3.8σ and 5.5σ, respectively, where the first uncertainties are statistical and the second ones systematic. No significant signal of D0→ηηη is found, and the upper limit on its decay branching fraction is set to be B(D0→ηηη)<1.3×10−4 at the 90% confidence level.
Background: Transient elastography (TE) has been validated as an effective noninvasive tool for the assessment of liver fibrosis. The XL probe is a new probe that was initially designed for use in patients with obesity. A meta-analysis was performed to assess the feasibility and efficacy of TE using the XL probe.
Methods: In September 2016, we systematically searched the PubMed and Science Direct search engines. The feasibility of TE was evaluated based on the failure rate and the results of the unreliable liver stiffness measurement (LSM). The efficacy of TE was measured using sensitivity, specificity, and summary receiver-operating characteristic as measures/indices assessed in different stages of fibrosis. Heterogeneity was measured using the chi-squared test and the Q-statistic. We used the 95% confidence interval (95% CI) as an effect measure.
Results: We included 8 studies in the meta-analysis. When the XL was compared to the M probe, the former showed a lower risk of failure rate [relative risk (RR) 0.24, 95% CI 0.14–0.38]. In patients with a body mass index ≥30 kg/m2, the XL probe showed a statistically significantly lower risk of failure rate (RR 0.16, 95% CI 0.08–0.32) but no significant improvement (RR 0.76, 95% CI 0.50–1.16) in the unreliable LSM result. In patients showing liver fibrosis stage ≥F2, the XL probe showed a sensitivity of 0.56 (95% CI 0.39–0.72), specificity of 0.71 (95% CI 0.61–0.79), and an area under the curve (AUC) of 0.71. The results observed in patients with liver fibrosis stage F4 were more promising with a sensitivity of 0.84 (95% CI 0.76–0.90), specificity of 0.78 (95% CI 0.70–0.84), and an AUC of 0.88.
Conclusion: TE using the XL probe demonstrates significant diagnostic utility in patients with liver fibrosis and is likely to be more reliable than the M probe in patients with obesity. Large prospective multicenter studies are, however, necessary to establish the new cut-off values to be used for the XL probe in patients with obesity.