530 Physik
Refine
Year of publication
Document Type
- Article (1955)
- Preprint (1300)
- Doctoral Thesis (592)
- Conference Proceeding (242)
- diplomthesis (101)
- Bachelor Thesis (75)
- Master's Thesis (61)
- Contribution to a Periodical (56)
- Part of Periodical (36)
- Diploma Thesis (34)
Keywords
- Kollisionen schwerer Ionen (47)
- heavy ion collisions (44)
- LHC (25)
- Quark-Gluon-Plasma (25)
- Heavy Ion Experiments (21)
- equation of state (19)
- quark-gluon plasma (19)
- QCD (16)
- Relativistic heavy-ion collisions (16)
- QGP (15)
Institute
- Physik (4257)
- Frankfurt Institute for Advanced Studies (FIAS) (1391)
- Informatik (978)
- Präsidium (70)
- MPI für Biophysik (43)
- ELEMENTS (40)
- Biochemie und Chemie (18)
- Helmholtz International Center for FAIR (12)
- Biochemie, Chemie und Pharmazie (11)
- Geowissenschaften (9)
We propose to measure correlations of heavy-flavor hadrons to address the status of thermalization at the partonic stage of light quarks and gluons in high-energy nuclear collisions, shown on the example of azimuthal correlations of D-Dbar pairs. We show that hadronic interactions at the late stage can not disturb these correlations significantly. Thus, a decrease or the complete absence of these initial correlations indicates frequent interactions of heavy-flavor quarks in the partonic stage. Therefore, early thermalization of light quarks is likely to be reached. PACS numbers: 25.75.-q
The cumulant method is applied to study elliptic flow (v_2) in Au+Au collisions at sqrt s=200 AGeV, with the UrQMD model. In this approach, the true event plane is known and both the non-flow effects and event-by-event spatial (epsilon) and v_2 fluctuations exist. Qualitatively, the hierarchy of v_2 's from two, four and six-particle cumulants is consistent with the STAR data, however, the magnitude of v_2 in the UrQMD model is only 60% of the data. We find that the four and six-particle cumulants are good measures of the real elliptic flow over a wide range of centralities except for the most central and very peripheral events. There the cumulant method is affected by the v_2 fluctuations. In mid-central collisions, the four and six-particle cumulants are shown to give a good estimation of the true differential v_2, especially at large transverse momentum, where the two-particle cumulant method is heavily affected by the non-flow effects.
Elliptic flow analysis at RHIC with the Lee-Yang Zeroes method in a relativistic transport approach
(2006)
The Lee-Yang zeroes method is applied to study elliptic flow (v_2) in Au+Au collisions at sqrt s =200 A GeV, with the UrQMD model. In this transport approach, the true event plane is known and both the nonflow effects and event-by-event v_2 fluctuations exist. Although the low resolutions prohibit the application of the method for most central and peripheral collisions, the integral and differential elliptic flow from the Lee-Yang zeroes method agrees with the exact v_2 values very well for semi-central collisions.
We study the transition from fusion-fission phenomena at about 20 MeV/nucleon multifragmentation at 100–200 MeV/nucleon in the reaction 16O+80Br employing the quantum molecular dynamics model. The time evolution of the density and mass distribution, the charged-particle multiplicity, and spectra as well as angular distributions of light particles are investigated. The results exhibit the transition of the disassembly mechanism, but no sharp change is found. The results are in good agreement with recently measured 4-Pi data.
Ziel dieser Arbeit war, mittels einer (n,γ)-Aktivierung, 129Te zu erzeugen und eine Teilchenzahlbestimmung durchzuführen. Aktivierung der Probe am Forschungsreaktor TRIGA und Spektrenaufnahme mittels eines HPGe-Detektors erfolgten im Mai 2014 am Institut für Kernchemie der Johannes Gutenberg Universität in Mainz.
Die Teilchenzahl des Tochternuklids 129I kann anhand der Teilchenzahlen des Isomers und des Grundzustandes von 129Te berechnet werden. In den Aktivierungen #2 bis #6 wurden (14.27 ± 0.53)x10exp12 Iodnuklide erzeugt. Angegeben ist die maximal mögliche Anzahl von Iodteilchen bei unendlich langer Wartezeit und vollständigem Zerfall aller Tellurnuklide.
Beobachtet werden konnte die Abnahme der Grundzustandsaktivität bis zum Erreichen des Gleichgewichts aus Nachbevölkerung durch das Isomer und Zerfall. Die Grundzustandslinien der Energien von 459.60 keV, 487 keV, 1083 KeV und 1111 keV konnten zu dieser Untersuchung herangezogen werden. Diese 4 Linien erfüllen die erforderten Konsistenzkriterien bezüglich der Systematik und können daher zur Teilchenzahlbestimmung des Grundzustandes verwendet werden (Seite 31).
Der Einfluss der Eigenabsorption ist noch zu untersuchen, da die genaue Position der Probe im Polyethylenbehältnis nicht bestimmt werden konnte. Weiterhin ist die Datenanalyse der ersten Aktivierung aufgrund des Detektorwechsels noch nicht erfolgt. Der Austausch war wegen technischer Probleme notwendig. Ziel weiterführender Untersuchungen ist, eine erneute Halbwertszeitbestimmung des radioaktiven 129I vorzunehmen. Sie ist von Interesse, angesichts des Widerspruchs zweier Veröffentlichungen. Die Halbwertszeit des 129I kann Aufschluss über stellare Bedingungen des s-Prozesses geben.
The advent of improved experimental and theoretical techniques has brought a lot of attention to the electric dipole (E1) response of atomic nuclei in the last decade. The extensive studies have led to the observation and interpretation of a concentration of E1 strength energetically below the Giant Dipole Resonance in many nuclei. This phenomenon is commonly denoted as Pygmy Dipole Resonance (PDR). This contribution will summarize the most important results obtained using different experimental probes, define the challenges to gain a deeper understanding of the excitations, and discuss the newest experimental developments.
The article presents the results of numerical and experimental investigations of guided wave propagation in aluminum plates with variable thickness. The shapes of plate surfaces have been specially designed and manufactured using a CNC milling machine. The shapes of the plates were defined by sinusoidal functions varying in phase shift, which forced the changes in thickness variability alongside the propagation path. The main aim of the study is to analyze the wave propagation characteristics caused by non-uniform thickness. In the first step, the influence of thickness variability on the time course of propagating waves has been analyzed theoretically. The study proves that the wave propagation signals can be determined based on knowledge about the statistical description of the specimen geometry. The histograms of thickness distribution together with the a priori knowledge of the dispersion curves were used to develop an iterative procedure assuming that the signal from the previous step becomes the excitation in the next step. Such an approach allowed for taking into account the complex geometry of the plate and rejecting the assumption about the constant average thickness alongside the propagation path. In consequence, it was possible to predict correctly the signal time course, as well as the time of flight and number of propagating wave modes in specimens with variable thickness. It is demonstrated that theoretical signals predicted in this way coincide well with numerical and experimental results. Moreover, the novel procedure allowed for the correct prediction of the occurrence of higher-order modes.
The article investigates the results obtained from numerical simulations and experimental tests concerning the propagation of guided waves in corroded steel plates. Developing innovative methodologies for assessing corrosion-induced degradation is crucial for accurately diagnosing offshore and ship structures exposed to harsh environmental conditions. The main aim of the research is to analyze how surface irregularities affect wave propagation characteristics. An investigation was conducted for antisymmetric fundamental mode A0. Specifically, the study examines the asymmetrical wavefronts generated by nonuniform thickness in damaged specimens. Initially, numerical analysis explores the impact of thickness variation on wave field symmetry. Corroded plates with varying levels of degradation are modeled using the random fields approach, with degradation levels ranging from 0 % to 60 %. Subsequently, the research investigates how the standard deviation of thickness distribution (from 5 % to 20 % of the initial thickness) and excitation frequency (from 50 to 150 kHz) influence recorded signals and the shape of reconstructed wavefronts. Each scenario compares wavefront symmetry levels estimated using rotational and bilateral symmetry degrees as indicative parameters. The numerical simulations are complemented by experimental tests conducted on plates with three different degradation levels. The results demonstrate the efficacy of the proposed wave field analysis approach for assessing structural integrity, as evidenced by the agreement between numerical predictions and experimental observations.
Ziel der vorliegenden Arbeit ist die Entwicklung, Aufbau und Inbetriebnahme eines Funnelsystems zur Zusammenführung zweier Teilchenstrahlen, bestehend aus zwei Injektionssystemen, zwei RFQ-Beschleunigern, Hochfrequenz-Deflektoren und Diagnoseeinheiten. Die Aufgabe des Experiments ist die praktische Umsetzung eines neuartigen Verfahrens zur Strahlstromerhöhung bei im Idealfall gleichbleibender Emittanz und steigender Brillanz. Notwendig wird dies durch die benötigten hohen Strahlströme im niederenergetischen Bereich einiger zukünftiger geplanter Beschleunigeranlagen. Hier kann der Strahlstrom nicht mehr konventionell von einer einzigen Ionenquelle erzeugt werden. Nur durch die Parallelerzeugung mehrerer Teilchenstrahlen sowie mehrfachem Zusammenführen (Funneling) der Teilchenstrahlen ist es möglich, die notwendigen Strahlströme bei der geforderten kleinen Emittanz zur Verfügung zu stellen. Das Frankfurter Funneling-Experiment ist die skalierte erste HIDIF-Funneling-Stufe als Teil eines Fusionstreibers. Hier werden zwei möglichst identische Helium-Teilchenstrahlen von zwei Ionenquellen erzeugt und in zwei RFQ-Beschleunigern beschleunigt. Der Deflektor biegt die Teilchenstrahlen reißverschlussartig auf eine gemeinsame Strahlachse. Am Anfang der Arbeit stand die Optimierung des Betriebs der Beschleunigerkomponeten und die Entwicklung und der Aufbau eines Einzellendeflektors. Erste erfolgreiche Strahlexperimente zur Strahlvereinigung werden im Kapitel 7.5 vorgestellt. Die Phasenraumellipse des zusammengeführten Strahls zeigt starke bananenförmige Deformierungen, die auf eine schlechte Anpassung des RFQ an den Funnel-Deflektor zurückzuführen sind. Das Elektrodendesign des RFQ ist in zwei unabhängige Bereiche unterteilt. Die erste Zone dient der Beschleunigung der Teilchen. In der zweiten Zone soll erstmals ein sogenannter 3D-Fokus der Strahlradien der x- und y-Ebene und einer longitudinaler Fokussierung erreicht werden. Der zweite Abschnitt bestand für erste Strahltests aus zunächst unmodulierten Elektroden. Zur besseren Anpassung des RFQ an den Funneldeflektor wurde dann das letzte Elektrodenteil erneuert. Der Umbau erfolgte zunächst nur bei einem der beiden RFQ-Beschleuniger. Somit war der direkte Vergleich zwischen altem und neuen Elektrodendesign im Strahlbetrieb möglich. Mit diesem neuen Elektrodenendteil wurde eine Reduktion der Strahlradien der x- sowie y-Ebene, eine bessere longitudinalen Fokussierung sowie eine höhere Transmission erreicht (Kapitel 8). Damit ist es erstmals gelungen mit einer speziellen Auslegung der RFQ-Elektroden eine direkte Anpassung an nachfolgende Elemente zu realisieren. Untersuchungen zur Strahlzusammenführungen werden seit einigen Jahren am Institut durchgeführt. Mit der Entwicklung des 3D-matchers wurde ein weiteres der kritischen Probleme gelöst. Der Umbau des zweiten Beschleunigers findet zur Zeit statt. Nach der Inbetriebnahme werden Funneling-Experimente mit dem Einspalt- und einem neuem Vielspaltdeflektor folgen.
Diese Arbeit entstand im Zusammenhang mit dem Funneling-Experiment am Institut für Angewandte Physik. Dieses Experiment soll die praktische Umsetzung des für das HIDIF-Projekt benötigte Funneln zur Ionenstrom-Erhöhung demonstrieren. Dabei stand die Erzeugung zweier identischer Ionenstrahlen mit einer Energie von 4 keV im Vordergrund. Diese Ionenstrahlen werden in zwei aufeinander zulaufenden RFQ-Beschleunigern auf eine Energie von 160 keV beschleunigt. Der noch in Planung stehende Funneling-Deflektor bringt die beiden Ionenstrahlen auf eine gemeinsame Strahlachse. Zu Beginn der Diplomarbeit stand der Umbau der Emittanzmeßanlage auf eine PC-Plattform. Gleichzeitig wurde ein sogenannter Quellenturm zum Betrieb der Ionenquellen aufgebaut (vgl. Kapitel 7.2). Die Multicusp-Ionenquellen wurden von K. N. Leung vom Lawrence Berkeley National Laboratory (LBNL) entwickelt und gebaut. Das elektrostatische Linsensystem wurde von R. Keller (LBNL) entworfen und berechnet. Die beiden Linsensysteme wurden in unserer Werkstatt gefertigt. Der erste Teil des Testbetriebs der Injektionssysteme, bestehend aus der Multicusp- Ionenquelle sowie dem elektrostatischen Linsensystem auch LEBT (Low Energy Beam Transport) genannt, bestand aus der Messung des Strahlstromes sowie der zugehörigen Emittanz. Zum Messen des Strahlstromes stand eine durch Preßluft in den Ionenstrahl fahrbare Faradaytasse zur Verfügung. Von dieser Faradaytasse wurde eine Kennlinie zur Bestimmung der Spannung der Sekundärelektronen- unterdrückung aufgenommen (vgl. Kapitel 8.1). Zur Messung der Strahlemittanz wurde eine Emittanzmessung nach dem Schlitz-Gitter Prinzip vorgenommen (vgl. Kapitel 5, Kapitel 7.7-7.9). Beim Betreiben der Injektionssysteme stand vor allem der Synchronbetrieb im Vordergrund. Dabei wurde festgestellt, daß eine der beiden Ionenquellen auch ohne Linsensystem einen größeren Strahlstrom liefert (vgl. Kapitel 8.9). Der Unterschied zwischen den Ionenquellen beträgt bei einem Bogenstrom von 6 A über 20 %. Dies bedeutet für den späteren Strahlbetrieb am RFQ, daß zum Erzeugen gleicher Strahlströme eine Ionenquelle immer mit einem kleineren Bogenstrom betrieben werden muß. Die dadurch unterschiedlichen Plasmadichten sowie thermischen Belastungen der Plasmakammer und unterschiedlichen Füllgrade der elektrostatischen Linsen tragen zu den festgestellten Emittanzunterschieden bei. Zum späteren Vergleich der Injektionssysteme wurde ein Injektionssystem durch verschiedene Bogenströme, variierte Spannungen an den elektrostatischen Linsen sowie unterschiedlichen Gasdrücken in der Plasmakammer ausgemessen. Diese Messungen wurden nach Wechseln der Glühkathode sowie Demontage und Neumontage von Ionenquelle und Linsensystem wiederholt. Dabei wurde festgestellt, daß sich der Strahlstrom bei der Vergleichsmessung kaum, die Emittanz der Injektionssysteme aber bis ca. 10% ändert (vgl. Kapitel 8.5). Diese Unterschiede müssen bei dem späteren Vergleich mit dem zweiten Injektionssystem einbezogen werden.Beim Betrieb des zweiten Injektionssystems wurden im direkten Vergleich der Injektionssysteme Unterschiede zwischen dem Strahlstrom sowie der Emittanz festgestellt. Auch hier lieferte das zweite Injektionssystem den schon nach der Ionenquelle festgestellten größeren Ionenstrom. Die gemessenen normierten 90 % RMS-Emittanzen bei einem Strahlstrom von 1 mA betragen am Injektionssystem 1 , beim Injektionssystem 2 , bei einer e1 =0,0288 mm mrad e2 =0,0216 mm mrad Strahlenergie von 4 keV. Die Emittanzunterschiede betragen bis zu 30 %. Im Betrieb mit dem RFQ können die Linsensysteme nicht mit den identischen Spannungen betrieben werden. Dies ist zum einen auf die fertigungsbedingten Unterschiede zurückzuführen, zum anderen auf die abweichenden Plasmadichten zum Erreichen gleicher Strahlströme. Im geplanten HIDIF-Projekt sollen 48 Ionenquellen drei unterschiedliche Teilchenströme erzeugen. Bei dieser Anzahl an Ionenquellen für drei unterschiedliche Ionensorten wird das Erzeugen identischer Teilchenströme sicher noch schwerer zu bewältigen sein. Am Funneling-Experiment ist der Vergleich der beiden Injektionssysteme abgeschlossen. Der Doppelstrahl RFQ-Beschleuniger ist aufgebaut, es wurde bereits ein Ionenstrahl in den RFQ eingeschossen (vgl. Kapitel 8.13). Die normierten 90 % RMS-Emittanzen nach dem RFQ betragen 0,057 mm mrad sowie 0,0625 mm mrad für die beiden Strahlachsen. Der Emittanzunterschied ist kleiner 9 %. Die Emittanzen nach dem RFQ können nicht direkt mit den im Testbetrieb gemessenen Emittanzen der Injektionssysteme verglichen werden. Im Strahlbetrieb mit dem RFQ wurde eine Strahlenergie der Injektionssysteme von 4,15 keV benötigt. Außerdem mußten durch geänderte Einschußbedingungen in den RFQ die Linsenspannungen gegenüber dem Testbetrieb variiert werden. Mit dem Aufbau des Funneling-Deflektors wird zur Zeit begonnen. Nach der Erprobung wird der Einbau in die Strahlachse erfolgen.