Refine
Year of publication
Document Type
- Article (23)
- Bachelor Thesis (1)
- Doctoral Thesis (1)
- Master's Thesis (1)
Language
- English (26) (remove)
Has Fulltext
- yes (26)
Is part of the Bibliography
- no (26) (remove)
Keywords
- FRANZ (2)
- (n (1)
- (n, gamma) Reaktionen (1)
- (n, gamma) reactions (1)
- BaF2 Detektor-Array (1)
- BaF2 detector array (1)
- Beryllium-7 (1)
- Detektor-Array (1)
- Energieauflösung (1)
- Gamma-Kaskade (1)
Institute
- Physik (26) (remove)
The experimental area 2 (EAR-2) at CERNs neutron time-of-flight facility (n_TOF), which is operational since 2014, is designed and built as a short-distance complement to the experimental area 1 (EAR-1). The Parallel Plate Avalanche Counter (PPAC) monitor experiment was performed to characterize the beam pro↓le and the shape of the neutron 'ux at EAR-2. The prompt γ-flash which is used for calibrating the time-of-flight at EAR-1 is not seen by PPAC at EAR-2, shedding light on the physical origin of this γ-flash.
Above 1 MeV of incident neutron energy the fission fragment angular distribution (FFAD) has generally a strong anisotropic behavior due to the combination of the incident orbital momentum and the intrinsic spin of the fissioning nucleus. This effect has to be taken into account for the efficiency estimation of devices used for fission cross section measurements. In addition it bears information on the spin deposition mechanism and on the structure of transitional states. We designed and constructed a detection device, based on Parallel Plate Avalanche Counters (PPAC), for measuring the fission fragment angular distributions of several isotopes, in particular 232Th. The measurement has been performed at n_TOF at CERN taking advantage of the very broad energy spectrum of the neutron beam. Fission events were recognized by back to back detection in coincidence in two position-sensitive detectors surrounding the targets. The detection efficiency, depending mostly on the stopping of fission fragments in backings and electrodes, has been computed with a Geant4 simulation and validated by the comparison to the measured case of 235U below 3 keV where the emission is isotropic. In the case of 232Th, the result is in good agreement with previous data below 10 MeV, with a good reproduction of the structures associated to vibrational states and the opening of second chance fission. In the 14 MeV region our data are much more accurate than previous ones which are broadly scattered.
The production of 77,79,85,85mKr and 77Br via the reaction Se(a, x) was investigated between Ea = 11 and 15 MeV using the activation technique. The irradiation of natural selenium targets on aluminum backings was conducted at the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, Germany. The spectroscopic analysis of the reaction products was performed using a high-purity germanium detector located at PTB and a low energy photon spectrometer detector at the Goethe University Frankfurt, Germany. Thicktarget yields were determined. The corresponding energy-dependent production cross sections of 77,79,85,85mKr and 77Br were calculated from the thicktarget yields. Good agreement between experimental data and theoretical predictions using the TALYS-1.6 code was found.
As a part of this thesis, a Monte Carlo-based code has been developed capable of simulating the transition of proton beam properties to neutron beam properties as it occurs in the Li-7(p, n)Be-7 reaction. It is able to reproduce not only the angle-integrated energy distributions but it is also capable of predicting the angle-dependent neutron spectra as measured at Forschungszentrum Karlsruhe (Karlsruhe, Germany) and Physikalisch-Technische Bundesanstalt (Braunschweig, Germany). Since the code retains all three spatial dimensions as well as all three velocity dimensions, it provides very detailed information on the neutron beam. The resulting data can aid in many different aspects, for example it can be used in shielding construction, or for lithium target design. In this work, the code is used to predict the neutron beam properties expected at the Frankfurt Neutron Source at Stern-Gerlach-Zentrum (FRANZ) facility. For different proton beam energies, the neutron distribution in x/p_x, y/p_y, and z/p_z is shown as well as a Mollweide projection, which illustrates the kinematic collimation effect that limits the neutron cone opening angle to less than 180 degree.
The current performance of a 4π barium fluoride gamma detector consisting of 41 modules is evaluated. It will be used to measure neutron capture events in different samples that are exposed to a neutron beam that is expected to contain up to 10^7 neutrons/(cm^2 sec). The capture cross-sections acquired in this experiment will be relevant to a multitude of different areas, for example to s-process studies, or accelerator-driven systems. The detector array was re-mounted after having been moved from Karlsruhe to Frankfurt and in the course of this process, the detector modules have been checked for their current detection properties. Every module consists of a BaF2 crystal, a photomultiplier tube connected to the crystal by sillicon oil and a voltage divider to drive the PMT, so each of them is already an individual gamma detector. Using Cobalt-60 and Caesium-137 test sources the energy resolution and - more importantly - the time resolution of every module has been determined; the results are presented in this work and compared to previous data taken at the time the detector was built initially in the mid-1980s.