Refine
Document Type
- Article (12)
- Conference Proceeding (1)
Has Fulltext
- yes (13)
Is part of the Bibliography
- no (13)
Keywords
- Cochlear implant (2)
- cochlear implant (2)
- speech perception (2)
- Active middle ear implants (1)
- Audio equipment (1)
- Audio signal processing (1)
- Audiology (1)
- Auditory system (1)
- Bone conduction devices (1)
- COVID-19 (1)
Institute
- Medizin (13)
Hearing loss in old age, which often goes untreated, has far-reaching consequences. Furthermore, reduction of cognitive abilities and dementia can also occur, which also affects quality of life. The aim of this study was to investigate the hearing performance of seniors without hearing complaints with respect to speech perception in noise and the ability to localize sounds. Results were tested for correlations with age and cognitive performance. The study included 40 subjects aged between 60 and 90 years (mean age: 69.3 years) with not self-reported hearing problems. The subjects were screened for dementia. Audiological tests included pure-tone audiometry and speech perception in two types of background noise (continuous and amplitude-modulated noise) which was either co-located or spatially separated (multi-source noise field, MSNF) from the target speech. Sound localization ability was assessed and hearing performance was self-evaluated by a questionnaire. Speech in noise and sound localization was compared with young normal hearing adults. Although considering themselves as hearing normal, 17 subjects had at least a mild hearing loss. There was a significant negative correlation between hearing loss and dementia screening (DemTect) score. Speech perception in noise decreased significantly with age. There were significant negative correlations between speech perception in noise and DemTect score for both spatial configurations. Mean SRTs obtained in the co-located noise condition with amplitude-modulated noise were on average 3.1 dB better than with continuous noise. This gap-listening effect was severely diminished compared to a younger normal hearing subject group. In continuous noise, spatial separation of speech and noise led to better SRTs compared to the co-located masker condition. SRTs in MSNF deteriorated in modulated noise compared to continuous noise by 2.6 dB. Highest impact of age was found for speech perception scores using noise stimuli with temporal modulation in binaural test conditions. Mean localization error was in the range of young adults. Mean amount of front/back confusions was 11.5% higher than for young adults. Speech perception tests in the presence of temporally modulated noise can serve as a screening method for early detection of hearing disorders in older adults. This allows for early prescription of hearing aids.
Nowadays, several options are available to treat patients with conductive or mixed hearing loss. Whenever surgical intervention is not possible or contra-indicated, and amplification by a conventional hearing device (e.g., behind-the-ear device) is not feasible, then implantable hearing devices are an indispensable next option. Implantable bone-conduction devices and middle-ear implants have advantages but also limitations concerning complexity/invasiveness of the surgery, medical complications, and effectiveness. To counsel the patient, the clinician should have a good overview of the options with regard to safety and reliability as well as unequivocal technical performance data. The present consensus document is the outcome of an extensive iterative process including ENT specialists, audiologists, health-policy scientists, and representatives/technicians of the main companies in this field. This document should provide a first framework for procedures and technical characterization to enhance effective communication between these stakeholders, improving health care.
Hintergrund und Fragestellung: Die Severe acute respiratory syndrome coronavirus type 2(SARS-CoV-2)-Pandemie hat die Ausbildung von Medizinstudierenden grundlegend verändert. Die Notwendigkeit von Kontaktbeschränkungen und die damit einhergehende Forderung nach Distanzunterricht hat dazu geführt, dass innerhalb kurzer Zeit digitale Lehrformate umgesetzt werden mussten. Ziel dieser Arbeit war die Auswertung der studentischen Evaluationsergebnisse für virtuellen Unterricht im Fach Hals-Nasen-Ohren-Heilkunde während der SARS-CoV-2-Pandemie und ein Vergleich mit den zuvor erhobenen Evaluationsergebnissen unter Präsenzbedingungen.
Material und Methoden: Untersucht wurden die Evaluationsergebnisse für die Blockpraktika im Wintersemester 2020/21 und im Sommersemester 2021, die in einem virtuellen Format mit kurzer Präsenzphase durchgeführt wurden, sowie die der komplett im konventionellen Präsenzformat durchgeführten Praktika von Sommersemester 2018 bis Wintersemester 2019/20. Die anonyme Befragung der Studierenden bezog sich auf verschiedene Aspekte der Lehrveranstaltung, wie z. B. Organisation, Didaktik und Lernatmosphäre.
Ergebnisse: Von 16 abgefragten Kategorien zeigten 14 (87,5%) signifikant bessere Evaluationsergebnisse für die virtuellen Praktika verglichen mit den zuvor im Präsenzformat durchgeführten Praktika. Diese sehr positive Bewertung des digitalen Lehrangebots zeigte im Pandemieverlauf über die Dauer von zwei Semestern keine signifikante Änderung.
Schlussfolgerung: Die vorliegenden Daten belegen die hohe Akzeptanz eines digitalen Lehrangebots im Fach HNO-Heilkunde für Studierende. Auch wenn unerlässliche Bestandteile der ärztlichen Ausbildung, wie der Unterricht am Patienten und das Erlernen klinisch-praktischer Fertigkeiten, weiterhin nur im Präsenzformat realisiert werden können, legen die Ergebnisse nahe, dass digitale Elemente auch nach der SARS-CoV-2-Pandemie eine Rolle im Medizinstudium spielen könnten.
Objectives: Previous studies investigating speech perception in noise have typically been conducted with static masker positions. The aim of this study was to investigate the effect of spatial separation of source and masker (spatial release from masking, SRM) in a moving masker setup and to evaluate the impact of adaptive beamforming in comparison with fixed directional microphones in cochlear implant (CI) users.
Design: Speech reception thresholds (SRT) were measured in S0N0 and in a moving masker setup (S0Nmove) in 12 normal hearing participants and 14 CI users (7 subjects bilateral, 7 bimodal with a hearing aid in the contralateral ear). Speech processor settings were a moderately directional microphone, a fixed beamformer, or an adaptive beamformer. The moving noise source was generated by means of wave field synthesis and was smoothly moved in a shape of a half-circle from one ear to the contralateral ear. Noise was presented in either of two conditions: continuous or modulated.
Results: SRTs in the S0Nmove setup were significantly improved compared to the S0N0 setup for both the normal hearing control group and the bilateral group in continuous noise, and for the control group in modulated noise. There was no effect of subject group. A significant effect of directional sensitivity was found in the S0Nmove setup. In the bilateral group, the adaptive beamformer achieved lower SRTs than the fixed beamformer setting. Adaptive beamforming improved SRT in both CI user groups substantially by about 3 dB (bimodal group) and 8 dB (bilateral group) depending on masker type.
Conclusions: CI users showed SRM that was comparable to normal hearing subjects. In listening situations of everyday life with spatial separation of source and masker, directional microphones significantly improved speech perception with individual improvements of up to 15 dB SNR. Users of bilateral speech processors with both directional microphones obtained the highest benefit.
Clinical speech perception tests with simple presentation conditions often overestimate the impact of signal preprocessing on speech perception in complex listening environments. A new procedure was developed to assess speech perception in interleaved acoustic environments of different complexity that allows investigation of the impact of an automatic scene classification (ASC) algorithm on speech perception. The procedure was applied in cohorts of normal hearing (NH) controls and uni- and bilateral cochlear implant (CI) users. Speech reception thresholds (SRTs) were measured by means of a matrix sentence test in five acoustic environments that included different noise conditions (amplitude modulated and continuous), two spatial configurations, and reverberation. The acoustic environments were encapsulated in a randomized, mixed order single experimental run. Acoustic room simulation was played back with a loudspeaker auralization setup with 128 loudspeakers. 18 NH, 16 unilateral, and 16 bilateral CI users participated. SRTs were evaluated for each individual acoustic environment and as mean-SRT. Mean-SRTs improved by 2.4 dB signal-to-noise ratio for unilateral and 1.3 dB signal-to-noise ratio for bilateral CI users with activated ASC. Without ASC, the mean-SRT of bilateral CI users was 3.7 dB better than the SRT of unilateral CI users. The mean-SRT indicated significant differences, with NH group performing best and unilateral CI users performing worse with a difference of up to 13 dB compared to NH. The proposed speech test procedure successfully demonstrated that speech perception and benefit with ASC depend on the acoustic environment.
Long-term effects on the quality of life following cochlear implant treatment in older patients
(2022)
Purpose: Even in older patients, hearing rehabilitation with a cochlear implant has become an established method for deafened or severely hearing-impaired patients. In addition to the hearing improvement, numerous other effects of CI treatment can be observed in clinical routine. In the literature, there is multiple evidence for a rapid and significant improvement in quality of life with CI treatment. The aim of this study was to evaluate the long-term effects of hearing rehabilitation using CI on the quality of life in older patients (≥ 65 years).
Methods: This prospective cross-sectional study examined 84 patients between the age of 65 and 101 years who received unilateral CI treatment for the first time between one and 10 years ago. The World Health Organization Quality-of-Life Scale-Old (WHOQL-OLD) was used to determine the quality of life. The study cohort was divided into three groups to compare the quality of life over time: group I (1–3 years after CI treatment), group II (4–6 years after CI treatment), and group III (7–10 years after CI treatment). In addition, the data from this study were compared with the results of our previous study (Issing et al. 2020) in which we focused on the first 6 months after CI treatment.
Results: In all three groups, there was a significant improvement in monosyllabic discrimination within 1 year after CI fitting (p > 0.001). No significant differences were found between the three groups. There were no significant differences between the three groups in the WHOQOL-OLD total score (p = 0.487) or any of the other six facets. Moreover, no significant differences were found compared to the study group of our previous study 6 months after CI treatment.
Conclusion: This study demonstrates the long-term stability of the improved quality of life following unilateral CI treatment in patients aged 65 years or older.
Background: Although noise is one of the leading work-related health risk factors for teachers, many nursery schools lack sufficient noise reduction measures. Methods: This intervention study evaluated the noise exposure of nursery school teachers when dropping DUPLO toy bricks into storage cases. Sound analyses of the impact included assessment of the maximum sound pressure level (LAFmax) as well as frequency analyses with 1/3 octave band filter. For the purpose of standardization, a customized gadget was developed. Recordings were performed in 11 cases of different materials and designs to assess the impact on sound level reduction. Thereby, the acoustic effects of three damping materials (foam rubber, carpet, and PU-foam) were investigated. Results: The lowest LAFmax was measured in cases consisting of “metal grid” (90.71 dB) or of a woven willow “basket” (91.61 dB), whereas a case of “aluminium” (103.34 dB) generated the highest impact LAFmax. The frequency analyses determined especially low LAFmax in the frequency bands between 80 and 2500 Hz in cases designs “metal grid” and “basket”. The insertion of PU-foam achieved the most significant attenuation of LAFmax (−13.88 dB) and, in the frequency analyses, the best sound damping. Conclusion: The dropping of DUPLO bricks in cases contributes to the high noise level in nursery schools, but measured LAFmax show no evidence for the danger of acute hearing loss. However, continuous exposure may lead to functional impairment of the hair cells and trigger stress reactions. We recommend noise reduction by utilizing cases of woven “basket” with an insert of PU-foam.
Previous studies in patients with single-sided deafness (SSD) have reported results of pitch comparisons between electric stimulation of their cochlear implant (CI) and acoustic stimulation presented to their near-normal hearing contralateral ear. These comparisons typically used sinusoids, although the percept elicited by electric stimulation may be closer to a wideband stimulus. Furthermore, it has been shown that pitch comparisons between sounds with different timbres is a difficult task and subjected to various types of range biases. The present study aims to introduce a method to minimize non-sensory biases, and to investigate the effect of different acoustic stimulus types on the frequency and variability of the electric-acoustic pitch matches. Pitch matches were collected from 13 CI users with SSD using the binary search procedure. Electric stimulation was presented at either an apical or a middle electrode position, at a rate of 800 pps. Acoustic stimulus types were sinusoids (SINE), 1/3-octave wide narrow bands of Gaussian noises (NBN), or 1/3-octave wide pulse spreading harmonic complexes (PSHC). On the one hand, NBN and PSHC are presumed to better mimic the spread of excitation produced by a single-electrode stimulation than SINE. On the other hand, SINE and PSHC contain less inherent fluctuations than NBN and may therefore provide a temporal pattern closer to that produced by a constant-amplitude electric pulse train. Analysis of mean pitch match variance showed no differences between stimulus types. However, mean pitch matches showed effects of electrode position and stimulus type, with the middle electrode always matched to a higher frequency than the apical one (p < 0.001), and significantly higher across-subject pitch matches for PSHC compared with SINE (p = 0.017). Mean pitch matches for all stimulus types were better predicted by place-dependent characteristic frequencies (CFs) based on an organ of Corti map compared with a spiral ganglion map. CF predictions were closest to pitch matches with SINE for the apical electrode position, and conversely with NBN or PSHC for the middle electrode position. These results provide evidence that the choice of acoustic stimulus type can have a significant effect on electric-acoustic pitch matching.
Purpose: The treatment with a cochlear implant (CI) is the gold standard in therapy of patients with profound hearing loss or deafness. Successful hearing rehabilitation with a CI is a complex, multi-stage process. In medicine, “Clinical Practice Guidelines” (CPG) are widely accepted for the standardization of such processes. These are supplemented by medical registries in which data regarding the treatment can be collected and evaluated. The aim of this paper is to identify currently existing CI-related CPGs and registries in Europe.
Methods: Between 01/2021 and 06/2021, 42 countries on the European continent, including the United Kingdom, Russia and Turkey, were screened using an internet search (search engine: Google) and a key word search in the Pubmed database. Search terms were the respective country name combined with the following terms: “Cochlear Implant”, “CI”, “Cochlear implant clinical practice guideline”, “CI Guideline”, “Cochlear Implant Registry”, “CI Registry”, “Ear nose throat society”. The internet search was conducted in English as well as in the corresponding national language. The objective was to identify a CI-related CPG or registry.
Results: A CPG was found in 16 of 42 (38%) countries. In terms of population, this accounts for 645 million out of 838 million people (77%). A registry existed in 4 of the 42 (10%) countries assessed. This corresponds to 102 million out of 838 million (12%) people. In total, 4 out of 42 countries (10%) had both a CPG and a registry.
Conclusion: Our work shows numerous efforts in Europe to standardize CI care at the national level. While most people in Europe already live in countries with a CPG, this is not the case for CI registries. European-wide consensus on CPGs or registries does not yet exist. The present study thus provides a first assessment of the distribution of CI-related CPGs and registries.
Objectives: In this study, localization accuracy and sensitivity to acoustic interaural time differences (ITDs) in subjects using cochlear implants with combined electric-acoustic stimulation (EAS) were assessed and compared with the results of a normal hearing control group. Methods: Eight CI users with EAS (2 bilaterally implanted, 6 unilaterally implanted) and symmetric binaural acoustic hearing and 24 normal hearing subjects participated in the study. The first experiment determined mean localization error (MLE) for different angles of sound incidence between ± 60° (frontal and dorsal presentation). The stimuli were either low-pass, high-pass or broadband noise bursts. In a second experiment, just noticeable differences (JND) of ITDs were measured for pure tones of 125 Hz, 250 Hz and 500 Hz (headphone presentation). Results: Experiment 1: MLE of EAS subjects was 8.5°, 14.3° and 14.7°, (low-, high-pass and broadband stimuli respectively). In the control group, MLE was 1.8° (broadband stimuli). In the differentiation between sound incidence from front and back, EAS subjects performed on chance level. Experiment 2: The JND-ITDs were 88.7 μs for 125 Hz, 48.8 μs for 250 Hz and 52.9 μs for 500 Hz (EAS subjects). Compared to the control group, JND-ITD for 125 Hz was on the same level of performance. No statistically significant correlation was found between MLE and JND-ITD in the EAS cohort. Conclusions: Near to normal ITD sensitivity in the lower frequency acoustic hearing was demonstrated in a cohort of EAS users. However, in an acoustic localization task, the majority of the subjects did not reached the level of accuracy of normal hearing. Presumably, signal processing time delay differences between devices used on both sides are deteriorating the transfer of precise binaural timing cues.