Refine
Document Type
- Article (18)
Language
- English (18)
Has Fulltext
- yes (18)
Is part of the Bibliography
- no (18)
Keywords
- Magnetic resonance imaging (3)
- Algorithms (2)
- Bone density (2)
- COVID-19 (2)
- Multidetector computed tomography (2)
- Osteoporosis (2)
- Spine (2)
- Tomography (x-ray computed) (2)
- multidetector computed tomography (2)
- Age determination by skeleton (1)
- Anomalous venous atrial connections (1)
- Artificial intelligence (1)
- Bone diseases, Metabolic (1)
- Bone marrow (1)
- CT dual-energy computed tomography (1)
- Calcium (1)
- Cardiovascular diseases (1)
- Computed Tomography (1)
- Computed tomography imaging (1)
- Computed tomography, X-ray (1)
- Congenital (1)
- Contrast agent (1)
- Diagnostic imaging (1)
- Dual-energy computed tomography (1)
- Edema (1)
- Fetal heart (1)
- Heart defects (1)
- Heart transplantation (1)
- Herniated disk (1)
- Image processing (1)
- Image processing (computer-assisted) (1)
- Intervertebral disc displacement (1)
- MRI (1)
- Magnetic resonance (1)
- Myocarditis (1)
- Nonpenetrating (1)
- Osteoporotic fractures (1)
- Phantoms (imaging) (1)
- Positron emission tomography (1)
- Radiology (1)
- Retrospective studies (1)
- Retrospective study (1)
- Spinal fractures (1)
- Spinal injuries (1)
- Thorax (1)
- Tomography (1)
- Truncus arteriosus (1)
- Vaccination (1)
- Vasculitis (1)
- Vertebral body (1)
- Virtual noncalcium reconstructions (1)
- Wounds (1)
- X-ray computed (1)
- amino acids (1)
- aortic stenosis (1)
- breast cancer (1)
- cardiac remodeling (1)
- clear cell sarcoma (1)
- computed tomography (1)
- computer-assisted (1)
- diagnostic imaging (1)
- dual-energy (1)
- heart failure (1)
- heart neoplasms (1)
- liver (1)
- magnetic resonance imaging (1)
- neoplasm metastasis (1)
- portal vein (1)
- radiomics (1)
- rats (1)
- thrombosis (1)
Institute
- Medizin (18)
Low serum concentrations of the amino acid homoarginine (HA) are associated with increased cardiovascular mortality by incompletely understood mechanisms. This study sought to assess the influence of HA on cardiac remodeling in rats undergoing either transaortic banding or inhibition of nitric oxide synthesis by Nω-Nitro-L-arginine methyl ester hydrochloride (L-NAME). Male Wistar rats (n = 136) underwent sham operation (SH) or aortic banding (AB). Both groups were equally divided into 14 subgroups, receiving different doses of HA alone or in combination with lisinopril, spironolactone, or L-NAME for 4 weeks. HA treatment in AB animals resulted in a dose-dependent improvement of cardiac function up to a concentration of 800 mg·kg−1·day−1. Combining 800 mg·kg−1·day−1 HA with spironolactone or lisinopril yielded additional effects, showing a positive correlation with LV ejection fraction (+33%, p = 0.0002) and fractional shortening (+41%, p = 0.0014). An inverse association was observed with collagen area fraction (−41%, p < 0.0001), myocyte cross-sectional area (−22%, p < 0.0001) and the molecular markers atrial natriuretic factor (−74%, p = 0.0091), brain natriuretic peptide (−42%, p = 0.0298), beta-myosin heavy chain (−46%, p = 0.0411), and collagen type V alpha 1 chain (−73%, p = 0.0257) compared to placebo-treated AB animals. Co-administration of HA and L-NAME was found to attenuate cardiac remodeling and prevent NO-deficient hypertension following AB. HA treatment has led to a dose-dependent improvement of myocardial function and marked histological and molecular changes in cardiac remodeling following AB. Combining HA with standard heart failure medication resulted in additional beneficial effects boosting its direct impact on heart failure pathophysiology.
Highlights
• MRI and ultrasound provided significant correlations between findings suggestive of vasculitis and the final diagnosis.
• Careful selection of available imaging techniques is warranted considering the time course, location, and clinical history.
• Considering its moderate diagnostic power to distinguish tracer uptake, a holistic view of PET/CT findings is essential.
Abstract
Purpose: To assess the diagnostic value of different imaging modalities in distinguishing systemic vasculitis from other internal and immunological diseases.
Methods: This retrospective study included 134 patients with suspected vasculitis who underwent ultrasound, magnetic resonance imaging (MRI), or 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) between 01/2010 and 01/2019, finally consisting of 70 individuals with vasculitis. The main study parameter was the confirmation of the diagnosis using one of the three different imaging modalities, with the adjudicated clinical and histopathological diagnosis as the gold standard. A secondary parameter was the morphological appearance of the vessel affected by vasculitis.
Results: Patients with systemic vasculitis had myriad clinical manifestations with joint pain as the most common symptom. We found significant correlations between different imaging findings suggestive of vasculitis and the final adjudicated clinical diagnosis. In this context, on MRI, vessel wall thickening, edema, and diameter differed significantly between vasculitis and non-vasculitis groups (p < 0.05). Ultrasound revealed different findings that may serve as red flags in identifying patients with vasculitis, such as vascular occlusion or halo sign (p = 0.02 vs. non-vasculitis group). Interestingly, comparing maximal standardized uptake values from PET/CT examinations with vessel wall thickening or vessel diameter did not result in significant differences (p > 0.05).
Conclusions: We observed significant correlations between different imaging findings suggestive of vasculitis on ultrasound or MRI and the final adjudicated diagnosis. While ultrasound and MRI were considered suitable imaging methods for detecting and discriminating typical vascular changes, 18F-FDG PET/CT requires careful timing and patient selection given its moderate diagnostic accuracy.
Abnormal venous atrial (VA) connections present a congenital heart disease (CHD) challenge for pediatric cardiologists. Fully anatomical evaluation is very difficult in prenatal and perinatal follow-up, but it has a profound impact on surgical correction and outcome. The echocardiogram is first-line imaging and represents the gold standard tool for simple abnormal VA connection. CT and MRI are mandatory for more complex heart disease and “nightmare cases”. 3D post-processing of volumetric CT and MRI acquisition helps to clarify anatomical relationships and allows for the creation of 3D printing models that can become crucial in customizing surgical strategy.
Objectives: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging.
Methods: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard.
Results: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05).
Conclusions: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations.
Key Points
• Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference.
• Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series.
• Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.
Rationale and objectives: To provide a detailed analysis of injury patterns of the spine following blunt trauma and establish the role of supplementary MRI by evaluating discrepancies in the detection rates of damaged structures in CT and MRI.
Method: 216 patients with blunt trauma to the spine who underwent CT followed by supplementary MRI were included in this study. Two board-certified radiologists blinded to clinical symptoms and injury mechanisms independently interpreted all acquired CT and MRI images. The interpretation was performed using a dedicated catalogue of typical findings associated with spinal trauma and assessed for spinal stability using the AO classification systems.
Results: Lesions to structures associated with spinal instability were present in 31.0% in the cervical spine, 12.3% in the thoracic spine, and 29.9% in the lumbar spine. In all spinal segments, MRI provided additional information regarding potentially unstable injuries. Novel information derived from supplementary MRI changed clinical management in 3.6% of patients with injury to the cervical spine. No change in clinical management resulted from novel information on the thoracolumbar spine. Patients with injuries to the vertebral body, intervertebral disc, or spinous process were significantly more likely to benefit from supplementary MRI.
Conclusion: In patients that sustained blunt spinal trauma, supplementary MRI of the cervical spine should routinely be performed to detect injuries that require surgical treatment, whereas CT is the superior imaging modality for the detection of unstable injuries in the thoracolumbar spine.
Vaccination represents one of the fundamentals in the fight against SARS-CoV-2. Myocarditis has been reported as a rare but possible adverse consequence of different vaccines, and its clinical presentation can range from mild symptoms to acute heart failure. We report a case of a 29-year-old man who presented with fever and retrosternal pain after receiving SARS-CoV-2 vaccine. Cardiac magnetic resonance imaging and laboratory data revealed typical findings of acute myocarditis.
Case report of rare congenital cardiovascular anomalies associated with truncus arteriosus type 2
(2022)
Truncus arteriosus (TA) is a very rare congenital anomaly with complex cardiovascular anatomy and high lethality also due to severe associated anatomical variants and pathologies. As TA has a massive impact on the survival of a newborn and usually has to be surgically treated. Thus, it is of high importance to understand this congenital cardiovascular disease and associated complications, to improve life expectancy and outcome of these patients. We recently came across a newborn female patient with a rare complex case of persistent TA type 2 associated with further complex cardiovascular anomalies, who received a contrast enhanced CT scan on the 3 rd day post-partum, showing complex cardiovascular abnormalities that were ultimately incompatible with life.
In context of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), patients with certain comorbidities and high age, as well as male sex are considered to represent the risk group for severe course of disease. Corona-virus disease 2019 (COVID-19) typical CT-patterns include bilateral, peripheral ground glass opacity (GGO), septal thickening, bronchiectasis, consolidation as well as associated pleural effusion. We report a 77-year-old heart transplanted patient with confirmed COVID-19 infection and coronary heart disease, diabetes type II and other risk factors. Notably, only slight clinical symptoms were reported and repeated computed tomography (CT) scans showed an atypical course of CT findings during his hospitalization.
Purpose: To investigate the diagnostic performance of noise-optimized virtual monoenergetic images (VMI+) in dual-energy CT (DECT) of portal vein thrombosis (PVT) compared to standard reconstructions. Method: This retrospective, single-center study included 107 patients (68 men; mean age, 60.1 ± 10.7 years) with malignant or cirrhotic liver disease and suspected PVT who had undergone contrast-enhanced portal-phase DECT of the abdomen. Linearly blended (M_0.6) and virtual monoenergetic images were calculated using both standard VMI and noise-optimized VMI+ algorithms in 20 keV increments from 40 to 100 keV. Quantitative measurements were performed in the portal vein for objective contrast-to-noise ratio (CNR) calculation. The image series showing the greatest CNR were further assessed for subjective image quality and diagnostic accuracy of PVT detection by two blinded radiologists. Results: PVT was present in 38 subjects. VMI+ reconstructions at 40 keV revealed the best objective image quality (CNR, 9.6 ± 4.3) compared to all other image reconstructions (p < 0.01). In the standard VMI series, CNR peaked at 60 keV (CNR, 4.7 ± 2.1). Qualitative image parameters showed the highest image quality rating scores for the 60 keV VMI+ series (median, 4) (p ≤ 0.03). The greatest diagnostic accuracy for the diagnosis of PVT was found for the 40 keV VMI+ series (sensitivity, 96%; specificity, 96%) compared to M_0.6 images (sensitivity, 87%; specificity, 92%), 60 keV VMI (sensitivity, 87%; specificity, 97%), and 60 keV VMI+ reconstructions (sensitivity, 92%; specificity, 97%) (p ≤ 0.01). Conclusions: Low-keV VMI+ reconstructions resulted in significantly improved diagnostic performance for the detection of PVT compared to other DECT reconstruction algorithms.